Honeywell 50025034 50025034 User Manual OneWireless XYR 6000 Transmitter
Honeywell International Inc. 50025034 OneWireless XYR 6000 Transmitter
Contents
Pro Install Guide
OneWireless XYR 6000 Transmitter Professional Installation Guide Document ID: 50021956 Document File: OneWireless XYR 6000 Pro-Install Guide Rev B.doc Last Revision Date: 27 August 2008 Version: Rev B Preliminary This document and the information contained herein are confidential to and the property of Honeywell, Inc. and are made available only to Honeywell employees for the sole purpose of conducting Honeywell's business. This document, and any copy thereof, and the information contained herein shall be maintained in strictest confidence; shall not be copied in whole or in part except as authorized by the employee's manager; and shall not be disclosed or distributed (a) to persons who are not Honeywell employees, or (b) to Honeywell employees for whom such information is not necessary in connection with their assigned responsibilities. Upon request, or when the employee in possession of this document no longer has need for this document for the authorized Honeywell purpose, this document and any copies thereof shall be returned to the employee's manager. There shall be no exceptions to the terms and conditions set forth herein except as authorized in writing by the responsible Honeywell Vice President. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 1 of 28 Date 15 October 2007 18 August 2008 Revision OneWireless XYR 6000 Transmitter Professional Installation Guide Reason Document Release a) Added FCC and IC Compliance Statement information in Section 3 b) Added IC Compliance Statement and regulations in Section 17 c) Added label information in Section 15 d) Moved Abbreviations and Definitions to Section 1 e) Added Intended Country usage in Section 6 f) Add grounding wire information in Section 10 g) Removed IC ICES-001 statements h) Added 4 dBi Integral Antenna i) Added MSG information for FHSS/DSSS radios to Section 5 j) Split Table 10 into two parts (Table 11 and Table 12) so as to better show differences between FHSS and DSSS EIRP levels k) Split Table 11 into two parts (Table 13 and Table 14) so as to better show differences between FHSS and DSSS power levels l) Added cable lengths and cable losses to Table 11 and Table 12 m) Added restrictions for units installed in France to Table 11 and Table 12 n) Added and changed notes for Table 11 and Table 12 o) Added Multiple DI and Temperature DI to Table 1 p) Added note in French to Section 3.1 q) Added Table 7 for XYR 6000 with N connectors r) Added information for installation in Thailand Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 2 of 28 TABLE OF CONTENTS TABLE OF CONTENTS............................................................................................................................................................. 3 LIST OF FIGURES ..................................................................................................................................................................... 5 LIST OF TABLES ....................................................................................................................................................................... 5 DESIGNATION, SCOPE AND PREFACE....................................................................................................................... 6 1.1 1.2 1.3 1.4 1.5 DESIGNATION.................................................................................................................................................................. 6 SCOPE ............................................................................................................................................................................. 6 PREFACE ......................................................................................................................................................................... 6 SITE SURVEY................................................................................................................................................................... 6 ABBREVIATIONS & DEFINITIONS..................................................................................................................................... 8 FEDERAL COMMUNICATION COMMISSION (FCC) ............................................................................................... 9 2.1 FCC COMPLIANCE STATEMENTS .................................................................................................................................... 9 INDUSTRY CANADA (IC) ................................................................................................................................................ 9 3.1 IC COMPLIANCE STATEMENTS ........................................................................................................................................ 9 RF SAFETY STATEMENT: .............................................................................................................................................. 9 FCC AND INDUSTRY CANADA (IC) IDENTIFICATION NUMBERS: .................................................................. 10 5.1 5.2 FHSS RADIOS ............................................................................................................................................................... 10 DSSS RADIOS ............................................................................................................................................................... 10 INTENDED COUNTRY USAGE..................................................................................................................................... 11 6.1 6.2 6.3 NORTH AMERICA..................................................................................................................................................... 11 ASIA PACIFIC ............................................................................................................................................................ 11 EUROPEAN UNION................................................................................................................................................... 11 XYR 6000 TRANSMITTER GENERAL DESCRIPTION ............................................................................................ 12 7.1 7.2 INTENDED USE .............................................................................................................................................................. 12 XYR 6000 TRANSMITTER DIAGRAMS ........................................................................................................................... 12 PRODUCT SPECIFICATIONS ....................................................................................................................................... 13 8.1 8.2 8.3 8.4 8.5 8.6 FREQUENCY HOPPING SPREAD SPECTRUM (FHSS) RADIO, 2.4 GHZ ............................................................................ 13 DIRECT SEQUENCE SPREAD SPECTRUM (DSSS) RADIO, 2.4 GHZ ................................................................................. 13 XYR 6000 TRANSMITTER USER ENVIRONMENT ........................................................................................................... 14 XYR 6000 INSTRUMENT POWER SPECIFICATIONS ........................................................................................................ 14 WEIGHT ........................................................................................................................................................................ 14 DIMENSIONS.................................................................................................................................................................. 15 CABLES.............................................................................................................................................................................. 16 9.1 9.2 9.3 XYR 6000 TRANSMITTER WITH RP-TNC CONNECTORS ANTENNA OR LIGHTNING ARRESTOR CABLES ....................... 16 XYR 6000 TRANSMITTER WITH N CONNECTORS ANTENNA OR LIGHTNING ARRESTOR CABLES .................................. 16 LIGHTNING ARRESTOR TO ANTENNA CABLES ............................................................................................................... 16 10 ANTENNA LIGHTNING ARRESTORS .................................................................................................................... 17 11 APPROVED ANTENNA TYPES/GAINS ................................................................................................................... 17 12 EQUIVALENT ISOTROPICALLY RADIATED POWER (EIRP) ......................................................................... 18 OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 3 of 28 13 EIRP LIMITS................................................................................................................................................................. 18 14 SETTING TX POWER ................................................................................................................................................. 23 15 AGENCY LABEL INFORMATION ........................................................................................................................... 24 15.1 EXTERNAL FCC/IC LABELS .......................................................................................................................................... 24 15.1.1 50016195-001 – Transmitters with FHSS Radios................................................................................................ 24 15.1.2 50016195-002 – Transmitters with DSSS Radios ................................................................................................ 24 15.2 INTERNAL FCC/IC LABELS ........................................................................................................................................... 24 16 RF SAFETY, MAXIMUM PERMISSIBLE EXPOSURE (MPE) STATEMENT................................................... 25 17 AGENCY COMPLIANCE............................................................................................................................................ 26 17.1 RADIO AND EMC CERTIFICATIONS ............................................................................................................................... 26 17.1.1 Federal Communication Commission (FCC)....................................................................................................... 26 17.1.2 Industry Canada (IC) ........................................................................................................................................... 26 17.1.3 European Telecommunications Standards Institute (ETSI) ................................................................................. 26 17.1.4 Australian communications and media authority (ACMA) .................................................................................. 26 17.1.5 Thailand National Telecommunications Commission (TNTC) ............................................................................ 26 17.2 PRODUCT SAFETY AGENCY CERTIFICATIONS ................................................................................................................ 27 17.2.1 Canadian Standards Association (CSA)............................................................................................................... 27 17.2.2 Factory Mutual (FM) ........................................................................................................................................... 27 17.2.3 European ATEX Certification (ATEX) ................................................................................................................. 28 17.3 EUROPEAN UNION CERTIFICATION (CE-MARK) ............................................................................................................ 28 18 REFERENCE DOCUMENTS ...................................................................................................................................... 28 OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 4 of 28 LIST OF FIGURES Figure 1 – XYR 6000 Transmitters showing Right-angle Integral Antenna (left), Straight Integral Antenna (center) and Remote Antenna connector (right) options__________________________________________ 12 Figure 2 – Dimensions of the XYR 6000 Transmitter with Right-angle -2 dBi Integral Antenna __________ 15 LIST OF TABLES Table 1 – Model Key Numbers .....................................................................................................................................6 Table 2 –Table of Abbreviations and Definitions ..........................................................................................................8 Table 3 – Specifications of FHSS Radio Module in XYR 6000 Transmitter ...............................................................13 Table 4 – Specifications of DSSS Radio Module in XYR 6000 Transmitter...............................................................13 Table 5 – User Environment Specifications for XYR 6000 Transmitter......................................................................14 Table 6 – Transmitter to Antenna or Lightning Arrestor Cable Specifications for XYR 6000 with RP-TNC connectors ....................................................................................................................................................................................16 Table 7 – Transmitter to Antenna or Lightning Arrestor Cable Specifications for XYR 6000 with N connectors.......16 Table 8 – Lightning Arrestor to Antenna Cable Specifications ...................................................................................16 Table 9 – Lightning Arrestor Specifications for Remote Antenna(s) ..........................................................................17 Table 10 – Approved Antenna Types/Gains...............................................................................................................17 Table 11 – Maximum EIRP Limits for FHSS Radios ..................................................................................................18 Table 12 – Maximum EIRP Limits for DSSS Radios ..................................................................................................19 Table 13 – FHSS Transmit Power Settings for the antennas and cable lengths specified above for FCC, IC, ETSI, ACMA and TNTC approvals .......................................................................................................................................21 Table 14 – DSSS Transmit Power Settings for the antennas and cable lengths specified above for FCC, IC, ETSI, ACMA and TNTC approvals .......................................................................................................................................22 Table 15 – Reference documents..............................................................................................................................28 OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 5 of 28 1 1.1 DESIGNATION, SCOPE AND PREFACE Designation This document is valid for the following XYR 6000 Model Key numbers: Table 1 – Model Key Numbers Model Key Number STTW400 STTW8 Description Temperature Transmitter (remote sensors) Temperature Transmitter with integral probe STTW401 Temperature/Digital Inputs STTW500 Multiple Digital Inputs STIW600 High Level Analog Input Transmitter STGW9 Gauge and Absolute Pressure Transmitters STDW9 Differential Pressure Transmitters CETW6000M Corrosion Transmitter Model Selection Guide Table IV selections XF, EF or JF mean that the XYR 6000 has a FHSS radio. Model Selection Guide Table IV selections XD, ED or JD mean that the XYR 6000 has a DSSS radio. For the complete model number information, please see the appropriate XYR 6000 Transmitter Model Selection Guides. 1.2 Scope This document outlines professional installation requirements for the Honeywell XYR 6000 Transmitter for the Honeywell OneWireless Network. Professional installation is required to comply with certification agency and legal requirements. This document must be adhered to for all installations of the Honeywell OneWireless XYR 6000 Transmitters. 1.3 Preface This manual covers professional installation of the Honeywell OneWireless XYR 6000 Transmitters. See the Getting Started with Honeywell OneWireless, Honeywell OneWireless Planning Guide and Honeywell OneWireless XYR 6000 User’s Guides for general information on overall system implementation, configuration, and management of these devices. Since these devices may require that the Transmit (TX) power limit settings for the higher gain antennas be manually adjusted, then the XYR 6000 is classified by the FCC as a device that must be professionally installed. To be in compliance with FCC requirements, the radio must be installed with one of approved antennas listed in this document. 1.4 Site Survey It is assumed for the purposes of this document that a site survey has been performed and that the antenna types, cable lengths and lightning surge arrestors were appropriately selected per the results of that survey. Any changes to these items as a result of the actual installation of the XYR 6000 transmitters into the site may require that the TX power setting of the radio board OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 6 of 28 needs to be adjusted from the factory setting in order to maintain agency approvals. See Sections 13 and 14 for more information. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 7 of 28 1.5 Abbreviations & Definitions The term Honeywell XYR 6000 Transmitter will be used to describe the composite unit which includes the Honeywell FHSS or DSSS RF Module and all subassemblies housed within the XYR 6000 Transmitter enclosure. Table 2 –Table of Abbreviations and Definitions ACMA AD ATEX AWG Co-located COTS CSA DCS DSSS EMC ETSI EU FCC FHSS FM FSK GFSK HLAI IC IEEE IR IrDA LUI MPE MSG MTBF NA NEMA PCB PCI OQPSK RAM RJ-45 RPN SQA TNTC TX Wi-Fi WNSIA Australian Communications and Media Authority Authentication Device Potentially Explosive Atmospheres Directive American Wire Gauge Two or more radios transmitting simultaneously and with less than 20cm of separation distance. Commercial Off-The-Shelf Canadian Standards Association Distributed Control System Direct Sequence Spread Spectrum Electromagnetic Compatibility European Telecommunications Standards Institute European Union Federal Communications Committee Frequency-Hopping Spread Spectrum Factory Mutual Frequency Shift Keying Gaussian Frequency Shift Keying High Level Analog Input Industry Canada Institute of Electrical and Electronics Engineers Infrared Infrared Data Association Local User Interface Maximum Permissible Exposure Honeywell Model Selection Guide Mean Time Between Failures North America – United States of America and Canada National Electrical Manufacturers Association Printed Circuit Board Peripheral Components Interconnect Offset Quadrature Phase-Shift Keying Random Access Memory Registered Jack-45 Reverse Polarity N-type Supplier Quality Assurance Thailand National Telecommunications Commission Transmit Wireless Local Area Network based on IEEE 802.11 Specifications Wireless Network for Secure Industrial Application OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 8 of 28 2 2.1 3.1 FEDERAL COMMUNICATION COMMISSION (FCC) FCC Compliance Statements ¾ This device complies with Part 15 of FCC Rules and Regulations. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. ¾ This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. ¾ Intentional or unintentional changes or modifications must not be made to the XYR 6000 unless under the express consent of the party responsible for compliance. Any such modifications could void the user’s authority to operate the equipment and will void the manufacturer’s warranty. INDUSTRY CANADA (IC) IC Compliance Statements ¾ To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropic radiated power (EIRP) is not more than that permitted for successful communication. ¾ Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. ¾ This Class A digital apparatus complies with Canadian ICES-003. ¾ French: Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. RF Safety Statement: To comply with FCC’s and Industry Canada’s RF exposure requirements, the following antenna installation and device operating configurations must be satisfied. ¾ Remote Point-to-Multi-Point antenna(s) for this unit must be fixed and mounted on outdoor permanent structures with a separation distance between the antenna(s) of greater than 20cm and a separation distance of at least 20cm from all persons. ¾ Furthermore, when using integral antenna(s) the XYR 6000 unit must not be co-located with any other antenna or transmitter device and have a separation distance of at least 20cm from all persons. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 9 of 28 5 5.1 FCC and Industry Canada (IC) Identification Numbers: FHSS Radios • Honeywell XYR 6000 Transmitter FHSS Radio Module Identification Honeywell Identification for Class 1 Div 2 RF Modules: 50016517-001 Honeywell Identification for Intrinsically Safe RF Modules: 50025132-001 Honeywell XYR 6000 Transmitter FHSS Radio Limited Modular Approval Federal Communication Commission Identification for Class 1 Div 2 RF Modules: S5750016517 Federal Communication Commission Identification for Intrinsically Safe RF Modules: S5750016517 Honeywell XYR 6000 Transmitter FHSS Radio Limited Modular Approval Industry Canada Identification for Class 1 Div 2 RF Modules: 573I-50016517 Industry Canada Identification for Intrinsically Safe RF Modules: 573I-50016517 • • 5.2 DSSS Radios • Honeywell XYR 6000 Transmitter DSSS Radio Module Identification Honeywell Identification for Intrinsically Safe RF Modules: 50025034-001 Honeywell XYR 6000 Transmitter DSSS Radio Limited Modular Approval Federal Communication Commission Identification for Intrinsically Safe RF Modules: S5750025034 Industry Canada Identification for Intrinsically Safe RF Modules: 573I-50025034 • This information is shown on the label attached to each RF Module. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 10 of 28 6 INTENDED COUNTRY USAGE 6.1 NORTH AMERICA Country UNITED STATES CANADA 6.2 ISO 3166 2 letter code US CA ASIA PACIFIC Country AUSTRALIA THAILAND NEW ZEALAND 6.3 ISO 3166 2 letter code AU TH NZ EUROPEAN UNION Country Austria Belgium Bulgaria Cyprus Czech Republic Denmark Estonia Finland France Germany Greece Hungary Iceland Ireland Italy ISO 3166 2 letter code AT BE BG CY CZ DK EE FI FR DE GR HU IS IE IT OneWireless XYR 6000 Transmitter Professional Installation Guide Country Latvia Liechtenstein Lithuania Malta Netherlands Norway Poland Portugal Romania Slovakia Slovenia Spain Sweden Switzerland United Kingdom Honeywell Proprietary 50021956 ISO 3166 2 letter code LV LI LT MT NL NO PL PT RO SK SI ES SE CH BG Rev B 27 August 2008 Page 11 of 28 7 XYR 6000 TRANSMITTER GENERAL DESCRIPTION 7.1 Intended Use The XYR 6000 Transmitter is a key component of the Honeywell Wireless Network for Secure Industrial Application (WNSIA). These transmitters are available for various sensor types including Digital Inputs, Temperature, High Level Analog Inputs, Pressure and Corrosion. The XYR 6000 Transmitter uses a low-powered FHSS or DSSS 2.4 GHz radio to communicate with Multinode and Gateway devices that are connected to a wired DCS network. 7.2 XYR 6000 Transmitter Diagrams Figure 1 shows unit-level drawings of the XYR 6000 Transmitter antenna options. Figure 1 – XYR 6000 Transmitters showing Right-angle Integral Antenna (left), Straight Integral Antenna (center) and Remote Antenna connector (right) options The XYR 6000 Transmitter is available with either an integral antenna or with a remote antenna. Remote antennas are attached via cables to a connector on the XYR 6000. The integral antennas and/or the remote antenna connectors are not replaceable or changeable in the field. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 12 of 28 8 8.1 PRODUCT SPECIFICATIONS Frequency Hopping Spread Spectrum (FHSS) Radio, 2.4 GHz Warning! The XYR 6000 Transmitter must be Professionally Installed in accordance with the requirements specified in this document. See Section 10, for professional installation maximum TX power setting requirements. Only the specified TX power settings, antenna types and gains and cable lengths (attenuation) as outlined in this document are valid for XYR 6000 Transmitter installations. Table 3 – Specifications of FHSS Radio Module in XYR 6000 Transmitter Item Specification Wireless Standard Frequency Hopping Spread Spectrum (FHSS), 2.4 GHz Data Rates and Modulation Data Rate: 250 kbps Modulation: Gaussian Frequency Shift Keying (GFSK) Frequency Band 2,402 – 2,482 MHz Module Transmit Power Maximum: 20 dBm (Maximum transmit power will vary by channel) Receive Sensitivity (typical) 8.2 -97 dBm Direct Sequence Spread Spectrum (DSSS) Radio, 2.4 GHz Warning! The XYR 6000 Transmitter must be Professionally Installed in accordance with the requirements specified in this document. See Section 10, for professional installation maximum TX power setting requirements. Only the specified TX power settings, antenna types and gains and cable lengths (attenuation) as outlined in this document are valid for XYR 6000 Transmitter installations. Table 4 – Specifications of DSSS Radio Module in XYR 6000 Transmitter Item Specification Wireless Standard FCC 15.247 / IEEE 802.15.4 Direct Sequence Spread Spectrum (DSSS), 2.4 GHz Data Rates and Modulation Data Rate: 250 kbps Modulation: Offset Quadrature Phase-Shift Keying (OQPSK – DSSS) Frequency Band 2,405 – 2,475 MHz Module Transmit Power Maximum: 20 dBm (Maximum transmit power will vary by channel) Receive Sensitivity (typical) OneWireless XYR 6000 Transmitter Professional Installation Guide -100 dBm Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 13 of 28 8.3 XYR 6000 Transmitter User Environment Table 5 – User Environment Specifications for XYR 6000 Transmitter Item Specification Operating Temperature: –40ºC to +85ºC (–40°F to +185°F) Storage Temperature: –40ºC to +85ºC (–40°F to +185°F) Operating Humidity: 0 to 100% RH 8.4 XYR 6000 Instrument Power Specifications The XYR 6000 Transmitters operate from two (2) D-size 3.6V Lithium batteries. These are joined in series to produce a maximum voltage of +7.6 Vdc. An optional external +24 Volt power supply option will be available at a future date. 8.5 Weight The weight of the complete XYR 6000 Transmitter units shall be 14.0 lb. (6.4 kg) maximum. This weight does not include remote cables and antennas. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 14 of 28 8.6 Dimensions Figure 2 – Dimensions of the XYR 6000 Transmitter with Right-angle -2 dBi Integral Antenna Option OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 15 of 28 9 9.1 Cables XYR 6000 Transmitter with RP-TNC Connectors Antenna or Lightning Arrestor Cables Table 6 – Transmitter to Antenna or Lightning Arrestor Cable Specifications for XYR 6000 with RP-TNC connectors Honeywell Part Number 50018110-001 50018110-003 50018110-010 9.2 Cable Type 400 Series 400 Series 400 Series Connector Type RP-TNC to N male RP-TNC to N male RP-TNC to N male Frequency (GHz) 2.4 2.4 2.4 Length (m) 10 Loss (dB) XYR 6000 Transmitter with N Connectors Antenna or Lightning Arrestor Cables Table 7 – Transmitter to Antenna or Lightning Arrestor Cable Specifications for XYR 6000 with N connectors Honeywell Part Number 50018278-001 50018278-003 50018278-010 9.3 Cable Type 400 Series 400 Series 400 Series Connector Type N male to N male N male to N male N male to N male Frequency (GHz) 2.4 2.4 2.4 Length (m) 10 Loss (dB) Lightning Arrestor to Antenna Cables Table 8 – Lightning Arrestor to Antenna Cable Specifications Honeywell Part Number 50018278-001 50018278-003 50018278-010 OneWireless XYR 6000 Transmitter Professional Installation Guide Cable Type 400 Series 400 Series 400 Series Connector Type N male to N male N male to N male N male to N male Honeywell Proprietary 50021956 Frequency (GHz) 2.4 2.4 2.4 Rev B Length (m) 10 Loss (dB) 27 August 2008 Page 16 of 28 10 Antenna Lightning Arrestors Table 9 – Lightning Arrestor Specifications for Remote Antenna(s) Honeywell Part Number Manufacturer Manufacturer Part Number 50018279-090 ALTELECON AL-NFNFB-9 Specification Connector Type 50 ohm N Female to N Female Frequenc (GHz) 0–3 Attenuatio (dB) 0.4 (max) The lightning surge arrestor must be properly grounded in order to perform per specification. Connecting to local ground using a No. 12 (4 mm2) copper conductor is recommended. See the installation manual for other details. 11 Approved Antenna Types/Gains Table 10 – Approved Antenna Types/Gains Antenna Type Antenna Application Manufacturer Manufacturer Part Number Honeywell Part Number Beam Width Peak Gain (dBi) Freq. (GHz) Agency Compliance Omni (integral) Point to Multi-Point CENTURIO MAF94152 50016185-001 Omni -2 1 2.4 FCC, IC, ETSI, ACMA Omni (integral) Point to Multi-Point HYPERLINK WHON511 – 0001 50029933-001 Omni 2.4 FCC, IC, ETSI, ACMA Omni (remote) Point to Multi-Point HYPERLINK HGV-2409U 50018414-001 Omni 2.4 FCC, IC, ETSI, ACMA Directional (remote) Point to Multi-Point HYPERLINK HG2414D 50018415-001 25° 14 2.4 FCC, IC, ETSI, ACMA Note: 1. The Centurion antenna listed in Table 10 has a specified gain of 2.2 dBi. Through EIRP measurements performed during antenna qualification testing, this antenna when installed in the Honeywell Radome and attached to the XYR 6000 Transmitter body in either the right-angle or straight integral antenna options has an actual gain of -2 dBi. This value is used in determining the maximum EIRP for Agency Compliance. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 17 of 28 12 Equivalent Isotropically Radiated Power (EIRP) In radio communication systems, Equivalent Isotropically Radiated Power (EIRP) or, alternatively, Effective Isotropic Radiated Power, is the amount of power that would have to be emitted by an isotropic antenna (that evenly distributes power in all directions and is a theoretical construct) to produce the peak power density observed in the direction of maximum antenna gain. EIRP can take into account the losses in transmission line and connectors and includes the gain of the antenna. The EIRP is often stated in terms of decibels over a reference power level that would be the power emitted by an isotropic radiator with an equivalent signal strength. The EIRP allows making comparisons between different emitters regardless of type, size or form. From the EIRP, and with knowledge of a real antenna's gain, it is possible to calculate real power and field strength values. EIRP(dBm) = Radio TX Power (dBm) – Cable Loss (dB) + Antenna Gain(dBi) Antenna gain is expressed relative to a (theoretical) isotropic reference antenna (dBi). 13 EIRP LIMITS Table 11 – Maximum EIRP Limits for FHSS Radios Antenna Type -2 dBi Omni 4 dBi Omni 8 dBi Omni 14 dBi Directiona Radio Usage / Application Point to MultiPoint Point to MultiPoint Point to MultiPoint Point to MultiPoint Integral Integral Remote Remote OneWireless XYR 6000 Transmitter Professional Installation Guide Freq. (GHz) 2.4 2.4 2.4 2.4 Max. Ant. Gain (dBi) -2 14 Min. Cable Length (m) Honeywell Proprietary 50021956 Min. Cable Loss (dB) Agency/Country Max. Radio Output Power (dBm) Max. EIRP (dBm) FCC, IC 20 18 ETSI, ACMA, TNTC 20 18 France 2400-2454 MHz 20 18 France 2454-2482.5 MHz Do not use 3 --- FCC, IC 20 24 ETSI, ACMA, TNTC 16 20 France 2400-2454 MHz 16 20 France 2454-2482.5 MHz Do not use 3 --- FCC, IC 18 25 ETSI, ACMA, TNTC 13 20 France 2400-2454 MHz 13 20 France 2454-2482.5 MHz Do not use 3 --- FCC, IC 12 25 ETSI, ACMA, TNTC 20 France 2400-2454 MHz 20 France Do not use 3 --- Rev B 27 August 2008 Page 18 of 28 2454-2482.5 MHz Table 12 – Maximum EIRP Limits for DSSS Radios Antenna Type -2 dBi Omni 4 dBi Omni 8 dBi Omni 14 dBi Directiona Radio Usage / Application Point to MultiPoint Point to MultiPoint Point to MultiPoint Point to MultiPoint Integral Integral Remote Remote Freq. (GHz) 2.4 2.4 2.4 2.4 Max. Ant. Gain (dBi) -2 14 Min. Cable Length (m) Min. Cable Loss (dB) Agency/Country Max. Radio Output Power (dBm) Max. EIRP (dBm) FCC, IC 20 18 ETSI, ACMA, TNTC 14 12 France 2400-2454 MHz 14 12 France 2454-2482.5 MHz Do not use 3 --- FCC, IC 20 24 ETSI, ACMA, TNTC 12 France 2400-2454 MHz 12 France 2454-2482.5 MHz Do not use 3 --- FCC, IC 18 25 ETSI, ACMA, TNTC 12 France 2400-2454 MHz 12 France 2454-2482.5 MHz Do not use 3 --- FCC, IC 14 25 ETSI, ACMA, TNTC -2 11 France 2400-2454 MHz -2 11 France 2454-2482.5 MHz Do not use 3 --- Notes for Table 11 and Table 12: 1. The values in the above tables have been determined through agency certification testing. 2. The following shall apply for antenna type, frequency range, application/usage and agency/country compliance: • Antenna gains above the maximum values shown shall not be used. • Cable length/loss below the minimum values shown shall not be used. • Maximum overall radio output power shown shall not be exceeded. • Maximum EIRP values shown above shall not be exceeded. 3. France restricts outdoor use to 10mW (10 dBm) EIRP in the frequency range of 2,454-2,483.5 MHz. Installations in France must limit EIRP to 10 dBm for operating modes utilizing frequencies in the range of 2,454 – 2,483.5MHz. For this reason, Honeywell does not recommend configuring frequency hopping modes that use this frequency range. For installations in France, use only the following OneWireless Frequency Hopping (FH) Mode Selections: EU Channel #1, EU Channel #7, NA/EU Guard Bands and NA/EU Channel 3 (FH Mode selections #4, 5, 8 and 10). OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 19 of 28 4. Industry Canada Compliance Statement: This device has been designed to operate with the antenna types listed in this document, and having a maximum gain of 14 dBi. Antenna types not included in this list or having a gain greater than 14 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 20 of 28 Table 13 – FHSS Transmit Power Settings for the antennas and cable lengths specified above for FCC, IC, ETSI, ACMA and TNTC approvals Description Model Selection Guide Table III Cable(s) Length (m) TX Power Setting for ETSI/ACMA/TNTC (dBm) TX Power Setting for FCC/IC (dBm) -2 dBi Integral Antenna V 0 0 0 0 or S 0 0 0 0 N/A 16 16 4 dBi Integral Antenna R 0 0 0 0 or H 0 0 0 0 N/A 16 16 8 dBi Omni w/o suppressor M 0 1 0 0 or M 0 3 0 0 1, 3 13 16 8 dBi Omni w/o suppressor M1000 10 15 16 8 dBi Omni with suppressor M0101 1+1 15 16 8 dBi Omni with suppressor M 0 1 0 3 or M 0 3 0 3 or M 0 3 10 or M 0 3 0 1 or M 1 0 0 3 or M 1 0 1 0 1+3, 3+3, 3+10, 3+1, 10+3, 10+10 16 16 14 dBi directional w/o suppressor D 0 1 0 0 or D 0 3 0 0 1,3 12 14 dBi directional w/o suppressor D1000 10 14 14 dBi directional with suppressor D0101 1+1 14 14 dBi directional with suppressor D 0 1 0 3 or D 0 3 0 1 or D 0 3 0 3 1+3, 3+1, 3+3 10 15 14 dBi directional with suppressor D 0 3 1 0 or D 1 0 0 3 3+10, 10+3 11 16 14 dBi directional with suppressor D1010 10+10 13 16 OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 21 of 28 Table 14 – DSSS Transmit Power Settings for the antennas and cable lengths specified above for FCC, IC, ETSI, ACMA and TNTC approvals Description Model Selection Guide Table III Cable(s) Length (m) TX Power Setting for ETSI/ACMA/TNTC (dBm) TX Power Setting for FCC/IC (dBm) -2 dBi Integral Antenna V 0 0 0 0 or S 0 0 0 0 N/A 14 16 4 dBi Integral Antenna R 0 0 0 0 or H 0 0 0 0 N/A 16 8 dBi Omni w/o suppressor M 0 1 0 0 or M 0 3 0 0 1, 3 16 8 dBi Omni w/o suppressor M1000 10 16 8 dBi Omni with suppressor M0101 1+1 16 8 dBi Omni with suppressor M 0 1 0 3 or M 0 3 0 3 or M 0 3 10 or M 0 3 0 1 or M 1 0 0 3 or M 1 0 1 0 1+3, 3+3, 3+10, 3+1, 10+3, 10+10 16 14 dBi directional w/o suppressor D 0 1 0 0 or D 0 3 0 0 1,3 -2 12 14 dBi directional w/o suppressor D1000 10 14 14 dBi directional with suppressor D0101 1+1 -1 14 14 dBi directional with suppressor D 0 1 0 3 or D 0 3 0 1 or D 0 3 0 3 1+3, 3+1, 3+3 -2 15 14 dBi directional with suppressor D 0 3 1 0 or D 1 0 0 3 3+10, 10+3 16 14 dBi directional with suppressor D1010 10+10 16 Notes for Table 13 and Table 14: 1. The Model Number of any instrument may be found on the identification name plate located on the outside of the XYR 6000 transmitter. The values in the Cable(s) Length column represent those customer selections from Table III of the XYR 6000 Model Selection Guides. 2. In the Cable(s) Length column, entries of the form “X+X” indicate that there are two cables between the XYR 6000 and the remote antenna, with a lightning surge arrestor used to connect the two cables together. Entries of the form “X” mean that there is a single cable and that no lightning surge arrestor is used. For entries of the form “X+X”; the first value is the length of the cable between the instrument and the arrestor while the second value is the length of the cable between the arrestor and the remote antenna. All cables are 400 series types as specified in Table 6 and Table 7. 3. TX Power is set by the Honeywell factory producing the XYR 6000 to the values shown in the above tables. These factory values are determined by the customer’s model number selections in Table III for antenna type, cables and the lightning suppressor. If the cable lengths, antenna type or the use of a lightning surge arrestor are changed in the field away from the Model Number listed on the instrument, then the TX power setting should likewise be changed per the tables above to match the new antenna/cable/arrestor selections. 4. The TX Power Setting values given in Table 12 and Table 13 represent the power produced by the Radio circuit within the RF Module. These TX Power Setting values do not include antenna gains nor do they include losses caused by cables, connectors and lightning arrestors. When these external gains and losses are included, using the TX power values in Table 13 and Table 14 ensures that the EIRP will not exceed the maximum limits as given in Table 11 and Table 12. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 22 of 28 14 Setting TX Power Warning! The XYR 6000 Transmitter must be Professionally Installed in accordance with the requirements specified in this document. Only the specified power settings, antenna types and gains and cable lengths (attenuation) as outlined in this document are valid for XYR 6000 Transmitter installations. TX Power setting is accomplished with the Authentication Device when a special application (app) is installed. This app is considered to be Honeywell sensitive material and is made available only to the qualified Professional Installer. When this app is installed in the AD, the XYR 6000 TX power setting, normally a read-only parameter, becomes a read/write parameter. Using the virtual keyboard in the Device Local Configuration AD routine to manipulate the local user interface (LUI), navigate to the TX_POWER display in the RADIO setup group. The XYR 6000 as shipped from the factory should show a TX Power value consistent with those given in Table 13 and Table 14. The TX Power adjustment feature is provided for Professional Installers to adjust the XYR 6000 TX power to match the specific selection of antenna and cables at the installation site and keep the total TX power under the regulatory thresholds. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 23 of 28 15 Agency Label Information The following information shall be clearly and permanently labeled on the XYR 6000 Transmitter unit: 15.1 External FCC/IC Labels 15.1.1 50016195-001 – Transmitters with FHSS Radios THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. FCC ID: S5750016517 / IC: 573I-50016517 15.1.2 50016195-002 – Transmitters with DSSS Radios THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. FCC ID: S5750025034 / IC: 573I-50025034 15.2 Internal FCC/IC Labels 50021957-001 RF MOD 50016517-001 FCC ID: S5750016517 IC: 573I-50016517 OneWireless XYR 6000 Transmitter Professional Installation Guide 50021957-002 50021957-003 RF MOD 50025132-001 FCC ID: S5750016517 IC: 573I-50016517 Honeywell Proprietary 50021956 RF MOD 50025034-001 FCC ID: S5750025034 IC: 573I-50025034 Rev B 27 August 2008 Page 24 of 28 16 RF Safety, Maximum Permissible Exposure (MPE) statement To comply with FCC’s and Industry Canada’s RF exposure requirements, the following antenna installation and device operating configurations must be satisfied: Remote antenna(s) for this unit must be fixed and mounted on outdoor permanent structures with a separation distance between the antenna(s) of at least 20 cm and a separation distance of at least 20 cm from all persons. When using integral antenna(s) the XYR 6000 Transmitter unit must not be co-located with any other antenna or transmitter device and have a separation distance of at least 20 cm from all persons. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 25 of 28 17 Agency Compliance 17.1 Radio and EMC Certifications 17.1.1 Federal Communication Commission (FCC) ¾ Specification: FCC Part 15.247 Subpart B for unintentional radiators ¾ Specification: FCC Part 15.247 Subpart C for intentional radiators 17.1.2 Industry Canada (IC) ¾ Method: RSS-210, Issue 7 ¾ RSS-Gen, Issue 2 ¾ ICES-003, Issue 4 17.1.3 European Telecommunications Standards Institute (ETSI) ¾ Emissions Specification and Method: EN 300 328 V1.7.1 ¾ Emissions Spec and Method: EN 301 893 V1.3.1 ¾ Immunity Specification: EN 301 489-17 V1.2.1 ¾ Immunity Method: EN 301 489-1 V1.6.1 ¾ Product Standard: IEC61326-1 (1st Edition, 2002-02, Industrial Locations) 17.1.4 Australian communications and media authority (ACMA) ¾ Specification: AS NZS 4771-2000 17.1.5 Thailand National Telecommunications Commission (TNTC) ¾ Specification: เรื่อง เครื่องวิทยุคมนาคมและสถานีวิทยุคมนาคมที่ไดรับยกเวนไมตองไดรับใบอนุญาต (Specification for non-licensed Radio and Radio Station Telecommunications) OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 26 of 28 17.2 Product Safety Agency Certifications 17.2.1 Canadian Standards Association (CSA) ANSI/ISA S82.02.01 (61010-1) CSA C22.2 No. 1010-1, ANSI/UL 61010-1, Safety Standard for Electrical Equipment for Measurement, Control and Laboratory Use – Part 1: General Requirements C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II C22.2 No. 25, Enclosures for Use in Class II, Group E, F & G Hazardous Locations C22.2 No. 94, Special Purpose Enclosures, Industrial Products C22.2 No. 14, Industrial Control Equipment, Industrial Products C22.2 No. 30, Explosion Proof Enclosures for Use in Hazardous Locations, Industrial Products C22.2 No. 157, Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations C22.2 No. 213, Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations E60079-0, Electrical Apparatus for Explosive Gas Atmospheres, Part 0: General Requirements E60079-1, Electrical Apparatus for Explosive Gas Atmospheres, Part 1: Flameproof “d” E60079-11, Electrical Apparatus for Explosive Gas Atmospheres, Part 11: Intrinsic Safety "i" E60079-15, Electrical Apparatus for Explosive Gas Atmospheres, Part 15: Electrical Apparatus With Type of Protection "n" • Temperature code: T4 (135°C) based on the maximum specified ambient of 85°C. 17.2.2 Factory Mutual (FM) ANSI/ISA S82.02.01 (61010-1) CSA C22.2 No. 1010-1, ANSI/UL 61010-1, Safety Standard for Electrical Equipment for Measurement, Control and Laboratory Use – Part 1: General Requirements FM electrical equipment requirements for use within Class I, Division 2, Groups A, B, C and D/Zone 2, Group IIC Hazardous Locations. Factory Mutual Approval Standard Class No. 3600, “Electrical Equipment for Use in Hazardous (Classified) Locations – General Requirements Factory Mutual Approval Standard Class No. 3810, “Electrical and Electronic Test, Measuring, and Process Control Equipment Factory Mutual Approval Standard Class No. 3611, “Electrical Equipment for Use in Class I, Division 2, Class II, Division 2 and Class III, Division 1 and 2 Hazardous (Classified) Locations • Temperature code: T4 (135°C) based on the maximum specified ambient of 85°C. OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 27 of 28 17.2.3 European ATEX Certification (ATEX) EN 60079-0, Electrical Apparatus for Explosive Gas Atmospheres, Part 0: General Requirements EN 60079-1, Electrical Apparatus for Explosive Gas Atmospheres, Part 1: Flameproof Enclosures “d” EN 60079-11, Electrical Apparatus for Explosive Gas Atmospheres, Part 11: Intrinsic Safety "i" EN 60079-15, Electrical Apparatus for Explosive Gas Atmospheres, Part 15: Electrical Apparatus with Type of Protection “n” EN 50281, Electrical Apparatus for Use in the Presence of Combustible Dust EN 50284, Special Requirements for Construction, Test and Marking of Electrical Apparatus of Equipment Group II, Category 1G The temperature code for the XYR 6000 Transmitter shall not exceed T4 (135°C) based on the maximum specified ambient of 85°C. 17.3 European Union Certification (CE-mark) • Compliance with: R&TTE Directive 1999/5/EC EMC Directive 2004/108/EC LVD Directive 73/23/EEC ATEX Directive 94/9/EC 18 Reference Documents Table 15 – Reference documents Getting Started with Honeywell OneWireless Honeywell OneWireless Planning Guide Honeywell XYR 6000 User’s Manuals Radio Antenna: A Primer White Paper Honeywell OneWireless System Administration Guide Honeywell OneWireless Field Network Dictionary OneWireless Builder Parameter Reference OneWireless Builder User’s Guide OneWireless XYR 6000 Model Selection Guides OneWireless XYR 6000 Transmitter Professional Installation Guide Honeywell Proprietary 50021956 Rev B 27 August 2008 Page 28 of 28
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Company : Honeywell Intl. Category : Installer Guide Source Modified : D:20080827122330 Create Date : 2008:08:27 08:25-04:00 Creator Tool : Acrobat PDFMaker 8.1 for Word Modify Date : 2008:08:27 08:25:49-04:00 Metadata Date : 2008:08:27 08:25:49-04:00 Document ID : uuid:d30b6984-b4f6-472c-8916-19039054ccac Instance ID : uuid:9776e59f-7cb0-4d61-9242-27cbca56b9bd Subject : 37 Format : application/pdf Creator : 50021956 Title : OneWireless XYR 6000 Transmitter Description : Professional Installation Guide Headline : Professional Installation Guide Page Count : 28 Page Layout : OneColumn Author : 50021956 Keywords : Rev, BEXIF Metadata provided by EXIF.tools