Honeywell He360 Installation Information 69 1572 Humidifier Kit
2015-08-26
: Honeywell Honeywell-He360-Installation-Information-803054 honeywell-he360-installation-information-803054 honeywell pdf
Open the PDF directly: View PDF
.
Page Count: 8
| Download | |
| Open PDF In Browser | View PDF |
HE360 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME INSTALLATION To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat and irritated nasal passages that aggravate allergies and asthma are steadily improving. Preparing for the Installation You have also taken the first step in reducing the zapping you create when you walk on your carpet and then touch your TV, computer, metal door knob or your pet. Your furniture and woodwork are also benefitting from the difference that humidified air makes. Required Accessories (Included) Be sure to identify all the required (Table 1) accessories (included) and make sure the appropriate tools are available before beginning the installation. Table 1. Required Accessories. Quantity Congratulations! You have just made a great investment in improving the comfort of your home. APPLICATION This installation kit contains all the parts necessary to install your new Honeywell HE360 Humidifier. Accessory 20 ft (6.2m) 18 gauge, two-strand thermostat wire 20 ft (6.2m) 1/4 in. (6.35 mm) OD feed water tubing 10 ft (3.1m) 1/2 in (12.7 mm) ID drain tubing 1 bag Connecting and mounting hardware: Wire nuts (4) No. 8 sheet metal screws (18) Drain tube clamp Feed tube mounting clamps (6) Brass inserts (2) Plastic compression rings (2) 1 Sail switch 1 roll Duct tape Required Tools Tools required for installation include: • • • • • Tin snip. Screwdriver. Adjustable or open-end wrench. Drill, punch or awl. Level. Determining Best Location for Humidifier • Select a location for the humidifier on the supply (warm air stream) plenum. See Fig. 1. • Select a location that cannot damage the air conditioner A-coil during installation. • Do not locate the humidifier on the furnace body. ® U.S. Registered Trademark Copyright © 2001 Honeywell • •All Rights Reserved 69- 1572 HE360 HUMIDIFIER INSTALLATION KIT • Allow adequate clearance in front of and above the humidifier so you can easily remove the cover to perform routine maintenance. — Mount the humidifier at least 3 in. (78 mm) above the furnace body to allow adequate space for the solenoid valve and drain line. — Mount the humidifier in a conditioned space to prevent freezing. • Mount the switch at least 6 in. (152 mm) upstream from an elbow or junction, and at least 15 in. (381 mm) downstream from an elbow or junction. • Locate the switch on the opposite side of the duct from the air entrance. (See Fig. 1-3 in S688 Installation Instructions.) Selecting Location for Humidistat • Select a location for the humidistat on the return plenum or on the wall in the living space. — Mounting on the return plenum is the easiest installation for the control wiring circuit. For return duct mounting, the humidistat should be mounted upstream from the humidifier or bypass so that it is properly sensing the relative humidity of the living space. Locate the control at least 8 in. (203 mm) upstream from the humidifier in the return air duct. (See Fig 2.) RN TU RE TAL ON RIZ HO RN TU RE RN TU RE OY HB HIG RN TU RE WN DO O FL ALTERNATE LOCATION RETURN AIR RETURN AIR OY WB LO 6 in. (152 mm) MINIMUM M12808A BEST LOCATION RETURN AIR DUCT Fig. 1. Typical humidifier installation locations. Selecting Water Supply Location M12831 Fig. 2. Selecting duct location for humidistat. • Use either hard or soft water in the humidifier and either hot or cold water. The water flow rate, with the humidifier running, is 3.5 gal/hr (13 liters/hr) to flush the pad and provide moisture for evaporation. • Make sure that the 20 ft (6.2m) of feed water tubing provided is adequate to connect the water supply (saddle valve) with the humidifier solenoid valve. Locating Closest 120V Electrical Outlet • Select location with access to an outlet. If not available, contact an electrician to have one installed. • Make sure that the humidifier cord is adequate to reach from the humidifier to the outlet. • Make sure that the 20 ft (6.2m) of thermostat wire is adequate to reach from the humidifier solenoid, to the sail switch, to the humidistat. Locating Closest Floor Drain • Select location with access to a floor drain to provide drainage for air conditioner condensation and humidifier drainage. • If you do not have a drain available, we recommend that you install the Honeywell Whole House Drum or Disk Humidifier. Make sure that the 10 ft (3.1m) of drain tubing is adequate to reach from the humidifier drain connection to the floor drain. INSTALLING HUMIDIFIER WARNING Hazardous Voltage Can cause personal injury or equipment damage. Do not cut or drill into any air conditioning or electrical accessory. Selecting Location for Sail Switch • Select a location for the sail switch in the cold air return duct where the sail is in the direct path of an unrestricted air stream. — Sail switch detects when furnace fan is operating. • Select a location where the air duct is at least 12 in. (305 mm) deep and 8 in. (203 mm) wide to allow operation of the sail without affecting the smooth flow of air in the duct. — Airflow at the location can be vertical (up or down) or horizontal. CAUTION Sharp Edges Installation Hazard. Can cause personal injury. Wear gloves and safety glasses. 1. 2. IMPORTANT Mounting the S688 in warm air supply duct can reduce the sail life. 69-1572 15 in. (381 mm) MINIMUM 3. 2 Turn off power to the air handing system at the circuit breaker. Draw a level line on the plenum in the location chosen for the humidifier. (Leveling assures optimal humidifier performance.) Locate the template in the Humidifier Installation Instructions. HE360 HUMIDIFIER INSTALLATION KIT 4. 5. 6. Tape the template in position and trace around the template. Remove the template and carefully cut the rectangular opening. Disassemble the humidifier; remove the cover and take out the humidifier pad assembly. See Fig. 3. 10. Hinge the cover in place and secure with the thumbscrew located at the bottom of the cover. CONNECTING PLUMBING Use hot or cold water and either hard or softened water in the humidifier. FEED TUBE NOZZLE WATER DISTRIBUTION TRAY 1. Shut off the water. HUMIDIFIER PAD ASSEMBLY CAUTION Chemical Hazard. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. Do not use gas line. 2. HUMIDIFIER HOUSING COVER ASSEMBLY THUMB SCREW Use the self-piercing saddle valve (included) to tap into the water supply line at the location selected. See Fig. 5. If tapping into galvanized pipe, drain line and pre-drill 3/17 in. tap for saddle valve. M12809 NOTE: The saddle valve is not designed to regulate water flow. The valve is either open or closed. Fig. 3. Disassembling humidifier. 7. 8. Make sure the humidifier housing is level, then position it in the opening so the plastic tabs are in place on the lower sheet metal edge of the opening. Use pliers, as necessary, to flatten cut edges. See Fig. 4. Secure the humidifier housing to the opening at the top and bottom using sheet metal screws. IMPORTANT To prevent debris from clogging the solenoid inline filter, be sure to install the saddle valve handle pointing toward the ceiling. SCREW DRIVER SHEET METAL SCREWS (4) LEVEL DUCT WATER LINE OPENING TO AIR DUCT M20175 Fig. 5. Installing saddle valve. 3. PLASTIC TABS (2) DRAIN TUBING M20204 Fig. 4. Installing humidifier on duct. 9. Reinstall the humidifier pad assembly in the humidifier housing. Use 1/4 in. (6 mm) OD tubing and connect the saddle valve to the inlet side of the solenoid valve (see Fig. 6). a. Place the brass compression nut over the tubing. b. Install brass insert into end of tubing. c. Slide the plastic compression ring over the tubing. (Discard copper compression ring provided with valve.) NOTE: To prevent leaking, use plastic (Delrin) sleeve rings with plastic tubing. Use copper sleeve rings only with copper tubing. IMPORTANT Be sure to reconnect the water feed tube and ensure that the tube is not pinched or kinked. 3 69-1572 HE360 HUMIDIFIER INSTALLATION KIT Installing Sail Switch d. Insert the tubing into the solenoid valve fitting and support the valve while tightening the compression nut. Adapting Switch to Air Flow Direction NOTE: Do not over-tighten the compression nut. Moderate tightness prevents leaking. The S688A Sail Switch is provided with two counterbalancing springs in place as shown in Fig 8. These springs offset the effect of gravity for air flow direction. e. Repeat steps a. through d. for solenoid valve fitting. f. Secure tubing with clamps provided. IMPORTANT: Do not use the sail switch with both springs attached. Be sure to select air flow direction and remove spring(s) not required for installation. BRASS COMPRESSION NUT PLASTIC COMPRESSION RING BRASS INSERT M20176 UP Fig. 6. Installing feed tubing. 4. Connect a 1/2 in. (13 mm) drain tube to the humidifier drain fitting and run to the floor drain (see Fig. 7). a. Slide the drain clamp over the tubing. b. Push the tubing over the drain nipple on the humidifier. c. Hand-tighten the clamp around the tubing to secure the humidifier drain. d. Fasten the drain tubing (can use duct tape) along the route to prevent movement and ensure downward slope for correct drainage. M3014 Fig. 8. Adapting sail switch to air flow direction or mounting position. NOTE: Cut tubing to correct length so the tubing terminates at the drain. • Vertical downward air flow: Leave the spring in place that is attached to the bracket marked Down. Remove the spring that is attached to the bracket marked Up. • Vertical upward air flow: Leave the spring in place that is attached to the bracket marked Up. Remove the spring that is attached to the bracket marked Down. • Horizontal air flow: Remove both springs. 1. Mount the template (provided with the sail switch) at the desired location. NOTE: Be sure the arrow (indicating air flow) points in the correct direction. 2. M20177 3. Fig. 7. Installing drain tubing. 4. 69-1572 4 a. For horizontal mounting, level the long dimension shown on the template. b. For vertical mounting, plumb the long dimension. Cut the hole (indicated on the template) in the ductwork. Center punch the screw holes indicated and drill out with a 1/8 in. (13 mm) drill. Attach the sail to the switch as shown in Fig 9. HE360 HUMIDIFIER INSTALLATION KIT 4. 5. 6. 7. Position the foam gasket on the H8908 base. Position the base on the duct with the arrow up. Secure the base to the duct using the four 1 in. (25 mm) mounting screws provided with humidistat. Connect the low-voltage wires to the leads and replace the H8908 case. See Fig. 11. NOTE: For wall mounting instructions, see the H8908 Installation Instructions. – LOOSEN SETSCREW – INSERT SAIL – TIGHTEN SETSCREW HUMIDISTAT BASE REAR OF HUMIDISTAT SAIL M20181 Fig. 9. Attaching sail to switch. 5. Press together the sides of the wire loop. Insert the sail into the duct. (When in the Off position, the sail should point into the direction of airflow as shown in Fig.10.) WIRE SLOT HUMIDISTAT WIRES M20179 Fig. 11. Humidistat base and rear view. AIRFLOW WIRING CAUTION Hazardous Voltage. Can cause personal injury or equipment damage. Disconnect power supply before installing or servicing equipment. IMPORTANT All wiring must comply with applicable local code, ordinances and regulations. M20178 Wire the humidifier solenoid valve, sail switch, humidistat and transformer.See Fig. 12. Fig. 10. Inserting sail switch in direction of airflow. 6. 7. Secure the switch by using the sheet metal screws provided. After wiring, snap on the cover. HUMIDISTAT INSTALLING HUMIDISTAT OUTDOOR Humidity Control Régulateur d'humidité TEMPERATURE -30 ¡C -20 ¡F -25 ¡C -10 ¡F -20 ¡C 0 ¡F -10 ¡C +10 ¡F -5 ¡C +20 ¡F Over 0 ¡C Over 20 ¡F HUMIDITY SETTING 15% 20% 25% 30% 35% 40% SAIL SWITCH Mounting Duct 1. 2. 3. Apply the template to the duct location chosen for the humidistat. Make sure the template is level before drilling the holes. Refer to the template (provided with the H8908 Humidistat Installation Instructions) to drill the control assembly opening and mounting holes for the H8908. Remove the H8908 case from the base. HUMIDIFIER SOLENOID VALVE BLACK WHITE WHITE M20205 Fig. 12. Wiring the controls. 5 69-1572 HE360 HUMIDIFIER INSTALLATION KIT 1. 2. TESTING HUMIDIFIER OPERATION Run the two-strand thermostat wire from the humidifier to the humidistat, and from the humidistat to the sail switch. Cut lengths of thermostat wire to reach between components, leaving adequate wire at both ends for connections. Checklist ❑ ❑ ❑ ❑ ❑ Humidifier is level. Control wiring was reviewed using circuit diagram. Humidifier is plugged in. Feed line has no kinks. Drain line slopes continuously down and ends at floor drain. ❑ Water hose inside humidifier is connected to PerfectFlow™ water distribution tray. NOTE: Humidistat and sail switch can be wired in any order. 3. 4. 5. At the humidifier, connect the black and white conductors to the two yellow humidifer wires. (The red wires from the humidifier are not used.) At the humidistat, connect both black conductors to the two humidistat terminals. Use a wire nut to connect together the two white conductors. At the sail switch, connect the black and white conductors to the Com and NO sail switch terminals (NC terminal is not used). After installation use the following steps to check the humidifier operation: 1. Turn on the power and the water supply 2. Turn the H8908 Humidity Control to On and turn on the heat by setting the thermostat to 10ºF (6ºC) above room temperature. IMPORTANT The furnace blower must be on to activate the humidifier. 3. 4. 5. 69-1572 6 Make sure that water is flowing out of the drain hose. If water does not flow, see Troubleshooting Your Humidifier section. Check for leaks. Reset the thermostat and H8908 Humidity Control to a comfortable setting for automatic operation. HE360 HUMIDIFIER INSTALLATION KIT TROUBLESHOOTING YOUR HUMIDIFIER (TABLE 2) Table 2. Troubleshooting Humidifier. Problem Water leakage No water to drain. What to look for What to do Leaking joints. Shut off water. Tighten connections. Brass tubing inserts Verify that brass tubing inserts are used. Saddle valve leaking. Verify rubber pad is installed on saddle valve. Electrical Verify control circuit wiring. Check all connections. Humidistat Turn humidistat up and down and listen for contact to click. Humidifier power Verify that outlet has power. Sail switch Remove sail cover; turn on furnace fan and listen for faint click. Verify that sail can move freely in duct; check sail switch instructions to trim sail, if necessary. Solenoid After verifying other wiring components, turn on furnace fan, turn humidistat up and down, and listen for solenoid to click. Verify plumbing connections. Check for kinks. Plumbing Saddle valve Verify that needle pierces water line and then backs out needle to open valve. Humidifier Remove cover and verify that water flows into distribution tray. Drain tubing Verify no obstructions. 7 69-1572 HE360 HUMIDIFIER INSTALLATION KIT Home and Building Control Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 69-1572 G.H. 09-01 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. www.honeywell.com/yourhome
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 5.0 (Windows) Create Date : 2001:08:10 11:38:51Z Modify Date : 2009:01:03 18:42:24-06:00 Metadata Date : 2009:01:03 18:42:24-06:00 Creator Tool : FrameMaker 6.0 Format : application/pdf Creator : Home and Building Control Title : 69-1572 - HE360 Humidifier Installation Kit Description : Installaltion Instructions Document ID : uuid:c3379d6b-ae7d-4b0e-8e33-bc4266d40903 Instance ID : uuid:29342cb4-70bc-4098-a62a-3cbdd16e3e0c Page Count : 8 Subject : Installaltion Instructions Author : Home and Building ControlEXIF Metadata provided by EXIF.tools