Huawei Technologies AP8130DN Outdoor Wireless LAN Access Point User Manual Hardware Installation and Maintenance Guide
Huawei Technologies Co.,Ltd Outdoor Wireless LAN Access Point Hardware Installation and Maintenance Guide
Contents
Users Manual
Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide Issue 03 Date 2015-05-18 HUAWEI TECHNOLOGIES CO., LTD. Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://enterprise.huawei.com Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide About This Document About This Document Intended Audience This document describes hardware features of the AP8030DN and AP8130DN and provides basic installation methods. This document is intended for: Network planning engineers Hardware installation engineers Commissioning engineers Onsite maintenance engineers System maintenance engineers Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results. NOTICE is used to address practices not related to personal injury. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. ii Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide Symbol About This Document Description Calls attention to important information, best practices and tips. NOTE NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration. Change History Changes between document issues are cumulative. The latest document issue contains all changes made in previous issues. Issue 03 (2015-05-18) This version has the following updates: The following information is modified: Updated the mounting bracket. Optimized the cabling diagram. Added the command to check AP running status in V200R006C00. Added descriptions about PoE fault troubleshooting. Issue 02 (2014-12-05) This version has the following updates: The following information is modified: Installation of the angle adjusting component with AP8030DN is added. The following information is added: 1.4 Ordering Information. Issue 01 (2014-08-20) Initial commercial release Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. iii Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide Contents Contents About This Document.....................................................................................................................ii 1 AP8130DN & AP8030DN Overview..........................................................................................1 1.1 Device Structure.............................................................................................................................................................2 1.2 Indicator Description......................................................................................................................................................4 1.3 Basic Specifications........................................................................................................................................................7 1.4 Ordering Information......................................................................................................................................................8 2 AP Installation.............................................................................................................................10 2.1 Preparing for Installation..............................................................................................................................................11 2.2 Installation Flowchart...................................................................................................................................................12 2.3 Unpacking the Equipment............................................................................................................................................13 2.4 Determining the Installation Position...........................................................................................................................14 2.5 Installing the AP...........................................................................................................................................................16 2.5.1 Wall Mounting...........................................................................................................................................................16 2.5.2 Pole Mounting...........................................................................................................................................................23 2.6 Connecting Cables........................................................................................................................................................28 2.6.1 Connecting RF Cables...............................................................................................................................................28 2.6.2 Connecting Optical Fibers and Network Cables.......................................................................................................30 2.6.3 Connecting Ground Cables........................................................................................................................................33 2.6.4 Installing Outdoor Antennas......................................................................................................................................36 2.7 Installing the Security Lock..........................................................................................................................................39 2.8 Checking the AP After Installation..............................................................................................................................40 2.9 Powering on the AP......................................................................................................................................................40 3 Logging In to the AP...................................................................................................................41 3.1 Logging In to the AP Through the Console Port..........................................................................................................42 3.2 Logging In to the AP Using STelnet............................................................................................................................42 3.3 Logging In to the AP Using Telnet..............................................................................................................................43 3.4 Logging In to the AP Using a Web Client....................................................................................................................44 4 Hardware Failures.......................................................................................................................46 4.1 An device Fails to Be Powered On...............................................................................................................................47 4.2 An Optical Interface Cannot Turn Up..........................................................................................................................47 5 Appendix.......................................................................................................................................49 Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. iv Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide Contents 5.1 On-site Cable Assembly and Installation.....................................................................................................................50 5.1.1 Cable Assembly Precautions.....................................................................................................................................50 5.1.2 Assembling Power Cables.........................................................................................................................................51 5.1.3 Assembling Ethernet Cables......................................................................................................................................59 5.1.4 Installing Cable Accessories......................................................................................................................................73 5.1.5 Replacing the Mold of the Crimping Pliers...............................................................................................................89 5.2 Environmental Requirements for Device Operation....................................................................................................92 5.2.1 Environmental Requirements for an Equipment Room............................................................................................92 5.2.2 Requirements for Power Supply..............................................................................................................................100 5.3 Equipment Grounding Specifications.........................................................................................................................103 5.3.1 General Grounding Specifications...........................................................................................................................103 5.3.2 Grounding Specifications for an Equipment Room................................................................................................103 5.3.3 Grounding Specifications for Devices.....................................................................................................................103 5.3.4 Grounding Specifications for Communications Power Supply...............................................................................104 5.3.5 Grounding Specifications for Signal Cables...........................................................................................................105 5.3.6 Specifications for Laying Out Grounding Cables...................................................................................................105 5.4 Engineering Labels for Cables...................................................................................................................................106 5.4.1 Introduction to Labels..............................................................................................................................................106 5.4.2 Engineering Labels for Optical Fibers.....................................................................................................................114 5.4.3 Engineering Labels for Network Cables.................................................................................................................117 5.4.4 Engineering Labels for User Cables........................................................................................................................118 5.4.5 Engineering Labels for Power Cables.....................................................................................................................119 5.5 Guide to Using Optical Modules................................................................................................................................122 5.6 Fault Tag.....................................................................................................................................................................125 Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 1 AP8130DN & AP8030DN Overview AP8130DN & AP8030DN Overview About This Chapter Huawei AP8030DN and AP8130DN is the latest-generation 802.11ac outdoor access point (AP) that supports 3x3 MIMO. The AP is physically hardened and features enhanced outdoor coverage performance. It supports 2.4 GHz and 5 GHz frequency bands, complies with IEEE 802.11a/b/g/n/ac, and can work as wireless bridges. The AP can provide services simultaneously on the 2.4 GHz and 5 GHz frequency bands to support more access users. It provides comprehensive service support capabilities and features high reliability, high security, simple network deployment, automatic AC discovery and configuration, and real-time management and maintenance, which meets requirements of outdoor deployment. Huawei AP8030DNs and AP8130DNs comply with IP67 dustproof and waterproof protection standards, applicable to coverage scenarios (for example, squares, pedestrian streets, and amusement parks) and bridging scenarios (for example, wireless harbors, data backhaul, video surveillance, and train-to-ground backhaul). 1.1 Device Structure 1.2 Indicator Description 1.3 Basic Specifications 1.4 Ordering Information To place an order, contact the Huawei local office. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 1 AP8130DN & AP8030DN Overview 1.1 Device Structure Figure 1-1 and Figure 1-2 shows the appearance of the AP8030DN and AP8130DN. SYS Wireless0 Wireless1 Link/ACT1 Link/ACT2 GE1 GE0/PoE Link/ACT0 Figure 1-1 AP8030DN appearance SFP D efault Console SYS Wireless0 Wireless1 Link/ACT1 5G SFP 2.4G/5G 2.4G/5G 2.4G/5G Issue 03 (2015-05-18) Link/ACT2 GE1 GE0/PoE 4 10 1 Link/ACT0 Figure 1-2 AP8130DN appearance 10 5 5G 5G 10 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 1 AP8130DN & AP8030DN Overview Default Console Table 1-1 describes interfaces on the AP8030DN and AP8130DN. Table 1-1 Descriptions of interfaces No. Name Description GE0/PoE 10/100/1000M bit/s interface: connects to the wired Ethernet. The interface can connect to a PoE power supply to provide power for the AP. GE1 10/100/1000M bit/s interface: connects to the wired Ethernet. The interface can't connect to a PoE power supply to provide power for the AP. SFP Connects an optical fiber to the AP. An optical module must be installed first. 5G antenna interface Connects a 2.4GHz antenna to the AP to send and receive service signals. 2.4G or 5G antenna interface Connects a 2.4GHz or 5GHz antenna to the AP to send and receive service signals. Console Console: Console interface Default Reset button: restores factory settings and restarts the AP if you hold down the Reset button for more than 3 seconds. NOTE The Reset button is protected by a waterproof screw. Before pressing the Reset button, remove the waterproof screw. Keep the screw properly and install it again after pressing the Reset button. Issue 03 (2015-05-18) Security slot Connects to a security lock. Device ground screw Connects a ground cable to the AP. 10 Ground screw for the surge protective device Connects the AP to the ground point of an external surge protective device. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 1 AP8130DN & AP8030DN Overview NOTE The AP8130DN offers two internal DB9 ports, which have similar functions as external GE ports. In device usage, you are advised to connect the device through the GE ports but not the DB9 ports. CAUTION There is a scald warning label attached on the device, warning you not to touch the device after the device has been operating for a long time. 1.2 Indicator Description The AP8030DN and AP8130DN provides multiple indicators: SYS indicator, Link/ACT indicator, and Wireless indicator. The following tables describe indicators on the AP8030DN and AP8130DN. NOTE l Indicator colors may vary slightly at different temperature. W ireless0 W ireless1 Link/ACT2 Link/ACT0 SYS GE1 Link/ACT1 l After a Fit AP is powered on, you can run the led off command on the AC to turn off all AP indicators. To restore the indicators to normal working status, run the led on command. Indicators on a Fat AP cannot be turned off using the led off command. SYS indicator Table 1-2 Descriptions about the SYS indicator Issue 03 (2015-05-18) Type Color Status Description Default status after power-on Green Steady on The AP is just powered on and the software is not started yet. Software startup status Green Steady on after blinking once After the system is reset and starts uploading the software, the indicator blinks green once. Until the software is uploaded and started, the indicator remains steady green. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 1 AP8130DN & AP8030DN Overview Type Color Status Description Running status Green Blinking once every 2s (0.5 Hz) l The system is running properly, the Ethernet connection is normal, and STAs are associated with the AP. l The system enters the Uboot CLI. Alarm Green Blinking once every 5s (0.2 Hz) The system is running properly, the Ethernet connection is normal, and no STA is associated with the AP. The system is in low power consumption state. Blinking once every 0.25s (4 Hz) l The software is being upgraded. l After the software is uploaded and started, the AP working in Fit AP mode requests to go online on the AC and maintains this state until it goes online successfully on the AC (before the CAPWAP link is established). l The AP working in Fit AP mode fails to go online on the AC (the CAPWAP link disconnects). Fault Red Steady on A fault that affects services has occurred, such as a DRAM detection failure or system software loading failure. The fault cannot be automatically rectified and must be rectified manually. Link/ACT indicators Link/ACT indicators consist of Link/ACT0, Link/ACT1, and Link/ACT2, showing link status of interfaces GE0/PoE, GE1, SFP respectively. Table 1-3 Descriptions about the Link/ACT indicators Type Color Status Description LINK Green Steady on The system is running properly, the Ethernet connection is normal, and no data is being transmitted. ACT Green Blinking The system is running properly, the Ethernet connection is normal, and the AP is transmitting data. The indicator blinks more quickly when more data is being transmitted. Wireless indicators Wireless indicators consist of Wireless0 and Wireless1, showing wireless link status of the 5 GHz and 2.4/5 GHz radio interfaces respectively. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 1 AP8130DN & AP8030DN Overview Table 1-4 Traffic volume indicator Color Status Description Yellow/green Off Radios are disabled, and no STA is connected to the AP. Yellow/green Steady on The AP has STAs connected to the 2.4 GHz radio or 5 GHz radio, but no data is being transmitted. Green Blinking The AP has STAs connected to the 2.4 GHz radio and is transmitting data. The indicator blinks more quickly when more data is being transmitted. Yellow Blinking The AP has STAs connected to the 5 GHz radio and is transmitting data. The indicator blinks more quickly when more data is being transmitted. Yellow/green Blinking alternatively The AP has STAs connected to both the 2.4 GHz radio and 5 GHz radio. The indicator blinks more quickly when more data is being transmitted. Table 1-5 Wireless bridge indicator Issue 03 (2015-05-18) Color Status Description Yellow/green Off The AP is not transmitting or receiving data or the signal strength is extremely low. Blinking once every 2s (0.5 Hz) The AP is transmitting or receiving data normally, and the signal strength is low. Blinking green once every 0.25 seconds (4 Hz) The AP is transmitting or receiving data normally, and the signal strength is medium. Steady on The AP is transmitting or receiving data normally, and the signal strength is high. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 1 AP8130DN & AP8030DN Overview NOTE When the WDS/mesh function is enabled on an AP, the blinking frequency of its Wireless LED indicates the receive signal strength on the WDS/mesh connection by default. After you connect an AP to a WDS/ mesh network, you can run the wifi-light { signal-strength | traffic } command on the AC to make the Wireless LED blinking frequency indicate receive signal strength or service traffic rate. wifi-light signal-strength: l If the mesh function is enabled on the AP, the blinking frequency of the Wireless LED reflects the weakest signal strength of all neighboring APs. l If WDS is enabled on an AP, the blinking frequency of the Wireless LED reflects the strength of signals received from a WDS AP. l If the AP works in leaf mode, the blinking frequency of the Wireless LED reflects the strength of signals received from a middle AP. l If the AP works in middle mode, the blinking frequency of the Wireless LED reflects the strength of signals received from a root AP. l If the AP works in root mode, the blinking frequency of the Wireless LED reflects the weakest signal strength of middle APs. wifi-light traffic: allows the Wireless LED to reflect the service traffic volume on the radio. The Fat AP does not support WDS/Mesh functions; therefore, the Wireless indicator of the Fat AP does not indicate the signal strength. 1.3 Basic Specifications Table 1-6 and Table 1-7 provides basic specifications of the AP8030DN and AP8130DN. Table 1-6 Basic Specifications of the AP8030DN Item Description Technical specifications Dimensions (H x W x D) 100 mm x 290 mm x 260 mm Weight 3.6 kg System memory l 256 MB DDR3 l 64 MB Flash Power specifications Environment specifications Issue 03 (2015-05-18) Power input PoE power supply: -48 V DC (in compliance with IEEE 802.3at) Maximum power consumption 20.1 W Operating temperature -60 m to +1800 m: -40°C to +60°C Storage temperature -40°C to +70°C Operating humidity 0% to 100% (non-condensing) NOTE The actual maximum power consumption depends on local laws and regulations. 1800 m to 5000 m: Temperature decreases by 1°C every time the altitude increases 220 m. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 1 AP8130DN & AP8030DN Overview Item Description IP rating IP67 Atmospheric pressure 53 kPa to 106 kPa Table 1-7 Basic Specifications of the AP8130DN Item Description Technical specifications Dimensions (H x W x D) 100 mm x 290 mm x 260 mm Weight 4.0 kg System memory l 256 MB DDR3 l 64 MB Flash Power specifications Environment specifications Power input PoE power supply: -48 V DC (in compliance with IEEE 802.3at) Maximum power consumption 22.4 W Operating temperature -60 m to +1800 m: -40°C to +60°C Storage temperature -40°C to +70°C Operating humidity 0% to 100% (non-condensing) IP rating IP67 Atmospheric pressure 53 kPa to 106 kPa NOTE The actual maximum power consumption depends on local laws and regulations. 1800 m to 5000 m: Temperature decreases by 1°C every time the altitude increases 220 m. 1.4 Ordering Information To place an order, contact the Huawei local office. Issue 03 (2015-05-18) Part Number Description 02350ALD Assembling Components,AP8030DN,AP8030DN,AP8030DN Mainframe(11ac,General AP Outdoor,3x3 Double Frequency,Built-in Antenna) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide Issue 03 (2015-05-18) 1 AP8130DN & AP8030DN Overview Part Number Description 02359462 Assembling Components,AP8130DN,AP8130DN,AP8130DN Mainframe(11ac,General AP Outdoor,3x3 Double Frequency,External Antenna) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation AP Installation About This Chapter 2.1 Preparing for Installation 2.2 Installation Flowchart 2.3 Unpacking the Equipment 2.4 Determining the Installation Position 2.5 Installing the AP 2.6 Connecting Cables 2.7 Installing the Security Lock 2.8 Checking the AP After Installation 2.9 Powering on the AP Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 10 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation 2.1 Preparing for Installation This section describes safety precautions and tool preparations for AP installation. Safety Precautions Take proper measures to prevent injuries and device damage. Place the device in a dry and flat position away from any liquid and prevent the device from slipping. Keep the device clean. Do not put the device and tools in the aisles. CAUTION Only the qualified personnel are permitted to install and remove the device and its accessories. Before installation and operation, read the safety precautions carefully. Tool Preparation To install the APs, prepare tools listed in Table 2-1. Table 2-1 Tools Phillips screwdriver (M4) Torque screwdriver Torque socket (M6) 3mm/5mm (M3-M6) Issue 03 (2015-05-18) Hammer drill (φ8) Utility knife Cable cutter Diagonal pliers RJ45 crimping tool Wire stripper Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 11 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation Network cable tester Multimeter Inner hexagon wrench (M6) Ladder Adjustable wrench Rubber mallet ESD gloves Level Marker Torque wrench (Use an N-type open-end torque wrench.) 2.2 Installation Flowchart Figure 2-1 shows the flowchart for installing an AP8130DN. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 12 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation Figure 2-1 Installation flowchart Start Check before installation Against the wall Against the pole Determine the installation location Fix the wall-mounting Bracket against the pole Fix the wall-mounting Bracket against the wall Install the AP Connect the cable Connect the security lock to the lock hole Check after installation Power on the AP End 2.3 Unpacking the Equipment Before unpacking the carton, ensure that the packing carton is intact and not damaged or soaked. Stop unpacking if the equipment is rusted or soggy. Then, investigate causes and contact the supplier. After unpacking, check items in the carton against the packing list. If any item is missing, contact the supplier or agent. Usually, the packing carton contains all items listed in the packing list shown in Table 2-2. Table 2-2 Packing list Issue 03 (2015-05-18) No. Item Quantity AP device Mounting bracket Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 13 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation No. Item Quantity PG connector M4x12 hexagon socket head cap screw Expansion bolt Hose clamp OT terminal l M4: 2 l M6: 1 l M8: 1 Casting Adjustable-degree solid1 Quick Start Guide Pay attention to the following: Only the AP8030DN carton contains the casting adjustable-degree solid. Figures in the document are for reference only and may be different from actual devices. Remove the protective film on the AP surface before installation to prevent electrostatic discharge. 2.4 Determining the Installation Position When determining the AP installation position, comply with the following rules: Do not install the AP in the place with high temperature, dust, noxious gas, or unstable voltage, or in the place near flammable or explosive materials and interference sources such as a large radar station, radio station, and transformer station. Install the AP in a site that is free from leaking or dripping water, heavy dew, and humidity, and take protective measures to prevent water from flowing into the equipment along the cable. Install the AP in a hidden position that does not affect daily lives and work of residents. Make the engineering design by fully considering such factors as hydrology, geology, earthquake, electric power, and traffic. The selected site should comply with the environment design specifications of communications equipment. The AP8030DN and AP8130DN can be installed against a pole or a wall. The AP must be installed by professional installation personnel, and the installation position is determined according to the site survey. Figure 2-2 and Figure 2-3 shows dimensions of the AP8030DN and AP8130DN. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 14 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation Figure 2-2 Dimensions of an AP8030DN (unit: mm) 100 290 * *(3R( *( 260 /LQN$&7 6<6 /LQN$&7 :LUHOHVV /LQN$&7 :LUHOHVV 6)3 ** Figure 2-3 Dimensions of an AP8130DN (unit: mm) 290 100 * *(3R( *( 260 /LQN$&7 6<6 /LQN$&7 :LUHOHVV /LQN$&7 :LUHOHVV 6)3 ** The AP8030DN and AP8130DN have the same space requirements. Figure 2-4 shows space requirements for installing an AP8130DN. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 15 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation Figure 2-4 Space requirements for installing an AP8130DN (unit: mm) ≥500 ≥200 00 ≥200 'HIDXOW ≥1 ≥500 2.5 Installing the AP NOTE If the AP surface is covered with protective film, remove it before installation. 2.5.1 Wall Mounting Wall mounting requires use of the mounting bracket and matching expansion bolts. The AP8030DN installation requires use of the angle adjusting component but the AP8130DN does not. Installing an AP8030DN Installing an AP8130DN Installing an AP8030DN 1. Issue 03 (2015-05-18) Fix the mounting bracket to the wall, adjust the installation position, and use the marker to mark the drilling positions where expansion bolts are installed, as shown in the following figure. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 16 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation 37mm 64mm NOTE Usually, the device can be fixed by installing two expansion bolts at diagonal positions. 2. Use an 8 mm drill bit to drill 35 mm to 40 mm deep holes in the drilling positions and hammer the expansion bolts into the installation holes until the flat washers are completely attached to the wall. Then, remove the nut, spring washer, and flat washer in order. Ø8 35mm~40mm 90DŽ 3. Issue 03 (2015-05-18) Use four M4x12 hexagon socket head cap screws to fasten the AP-side module of the mounting bracket to the AP. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 17 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation * * * * ** ** ** 'HIDXOW 'HIDXOW ** Hexagon socket head cap screw M4 1N•m 4. Hang the wall-side module of the mounting bracket on the expansion bolts and use a wrench to fasten the flat washers, spring washers, and nuts in order. M6 5N•m 5. Issue 03 (2015-05-18) Hang the angle adjusting component on the mounting bracket and use a Phillips screwdriver to tighten the screw at position 3, with a tightening torque of 1.4N*m. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 18 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 6. 2 AP Installation Loosen the screws at position 1 and position 2 using an M6 hex key. NOTE The screw at position 4 does not need to be loosened. l To adjust the horizontal angle of the AP, use the M6 hex key to remove the screw at position 2, lift the angle adjusting component vertically, and adjust the angle adjusting component horizontally. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 19 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation l To adjust the vertical angle of the AP, use the M6 hex key to loosen the screw at position 1, install the AP, and adjust the vertical angle with the weight of the AP. 7. Hang the AP with the AP-side mounting bracket module to the wall-side mounting bracket module and tighten the screws to secure the AP. Installing an AP8130DN 1. Issue 03 (2015-05-18) Fix the mounting bracket to the wall, adjust the installation position, and use the marker to mark the drilling positions where expansion bolts are installed, as shown in the following figure. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 20 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation NOTE Usually, the device can be fixed by installing two expansion bolts at diagonal positions. 2. Use an 8 mm drill bit to drill 35 mm to 40 mm deep holes in the drilling positions and hammer the expansion bolts into the installation holes until the flat washers are completely attached to the wall. Then, remove the nut, spring washer, and flat washer in order. Ø8 35mm~40mm 90DŽ 3. Issue 03 (2015-05-18) Use four M4x12 hexagon socket head cap screws to fasten the AP-side module of the mounting bracket to the AP. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 21 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation 4. Hang the wall-side module of the mounting bracket on the expansion bolts and use a wrench to fasten the flat washers, spring washers, and nuts in order. 5. Hang the AP with the AP-side mounting bracket module to the wall-side mounting bracket module and tighten the screws to secure the AP. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 22 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation 2.5.2 Pole Mounting An outdoor AP must be installed on a pole with a diameter of 48 mm to 114 mm and the thickness must be at least 2.5 mm. The AP8030DN installation requires use of the angle adjusting component but the AP8130DN does not. Installing an AP8030DN Installing an AP8130DN Installing an AP8030DN 1. Issue 03 (2015-05-18) Determine the AP installation position and attach the mounting bracket on the pole using the hose clamp. a. Use the M6 hex torque screwdriver to loosen screws on the hose clamp and lift the lid. b. Slide the hose clamp through the hole of the mounting bracket, attach it to the pole, and close the hose clamp. c. Close the lid. d. Use the hex torque screwdriver to tighten the screws with a torque of 5 N•m. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 23 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation M6 5N•m 2. Hang the angle adjusting component on the mounting bracket and use a Phillips screwdriver to tighten the screw at position 3, with a tightening torque of 1.4N•m. 3. Loosen the screws at position 1 and position 2 using an M6 hex key. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 24 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation NOTE The screw at position 4 does not need to be loosened. l To adjust the horizontal angle of the AP, use the M6 hex key to remove the screw at position 2, lift the angle adjusting component vertically, and adjust the angle adjusting component horizontally. l To adjust the vertical angle of the AP, use the M6 hex key to loosen the screw at position 1, install the AP, and adjust the vertical angle with the weight of the AP. 4. Issue 03 (2015-05-18) Hang the AP with the AP-side mounting bracket module to the wall-side mounting bracket module and tighten the screws to secure the AP. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 25 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation Installing an AP8130DN Mounting an AP on a vertical pole 1. Issue 03 (2015-05-18) Determine the AP installation position and attach the mounting bracket on the pole using the hose clamp. a. Use the M6 hex torque screwdriver to loosen screws on the hose clamp and lift the lid. b. Slide the hose clamp through the hole of the mounting bracket, attach it to the pole, and close the hose clamp. c. Close the lid. d. Use the hex torque screwdriver to tighten the screws with a torque of 5 N•m. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 26 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2. 2 AP Installation Hang the AP with the AP-side mounting bracket module to the wall-side mounting bracket module and tighten the screws to secure the AP. Mounting an AP on a horizontal pole The procedure for installing the AP against a horizontal pole is similar to the procedure for installing the AP against a vertical pole. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 27 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation 2.6 Connecting Cables Figure 2-5 AP8130DN external cable arrangement Feed line Feed line Optical fiber Feed line Feed line Feed line Network cable Feed line 2.6.1 Connecting RF Cables Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 28 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation RF cable deployment requirements It is recommended that you connect a 50 ohm RF load to an idle antenna interface and wrap the RF load with insulation tape and waterproof tape. Huawei offers 50 ohm RF loads for you to purchase. Wrap the RF cable using one-layer PVC insulation tape, three-layer waterproof adhesive tape, and then three-layer PVC insulation tape. Before wrapping the waterproof tape, stretch the tape evenly until the tape turns 1/2 as wide as before. Wrap each layer of tape tightly and ensure that each layer covers more than 50% of the layer below it. Wrap the three-layer tape from bottom to top, from top to bottom, and then from bottom to top. Bend radius requirements: RG-8U RF cable: > 150 mm; 1/2" RF cable: > 50 mm; 7/8" RF cable: > 250 mm. One inch equals to 25.4 mm. NOTICE Tighten the nut of the AP's RF connector with a maximum torque of 1.2 N•m. RF cable connections 1. Antenna interfaces of the AP provides a 5 KA surge protection capability. Generally, no additional surge protective device needs to be installed, and the RF cables are directly connected to the antenna interfaces. 2. If a higher surge protection capability is required, the customer can purchase a surge protective device. When installing the surge protective device, ensure that it is connected to a ground cable. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 29 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation 2.6.2 Connecting Optical Fibers and Network Cables Connecting optical fibers NOTE The device can transmit upstream data over optical fibers. The optical fiber is connected to the device using fiber connectors (purchased independently). The following figure shows components of an optical fiber connector. Figure 2-6 Components of an optical fiber connector (1) Optical fiber (2) Support (3) Rubber ring (4) External connector shell 1. Select an optical cable of a proper length based on onsite cabling. 2. Remove the waterproof block from the rubber ring of the connector, as shown in the following figure. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 30 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation Figure 2-7 Removing the waterproof block 3. Assemble the connector on the optical fiber. a. Assemble the external connector shell and support, as shown in the following figure. Figure 2-8 Assembling the connector (1) b. Put the rubber ring on the optical fiber and insert it into the support in compliance with the direction indicated on the ring, as shown in the following figure. Figure 2-9 Assembling the connector (2) NOTE Ensure that the arrow on the rubber ring points to the support. 4. Issue 03 (2015-05-18) Remove the sealing cover of the optical fiber port on the device and insert the optical fiber into the port. Turn the support to find the correct optical fiber installation slot and push the support forward (together with the rubber ring) until the optical fiber is installed to the Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 31 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation correct position. Rotate the external connector shell clockwise until the red ring is not visible, as shown in the following figure. Figure 2-10 Connecting optical fibers NOTICE l Connect the optical fiber correctly; otherwise, the optical fiber may be damaged. l Bundle the optical fibers with binding tapes every 1 m. Connecting network cables 1. Use a shielded straight-through cable. Cut the cable into a proper length based on the distance between the AP and the PSE device, strip the cables on both ends, and crimp the wires into RJ45 connectors. 2. Make a network cable onsite according to pin assignment in Table 2-3. Otherwise, the communication quality is affected even if devices can be connected. Table 2-3 Pin assignment Issue 03 (2015-05-18) X1 Pin Wire Color X2 Pin White and orange Orange White and green Blue White and blue Green Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 32 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation X1 Pin Wire Color X2 Pin White and brown Brown NOTE Actually, APs use shielded straight-through network cables, which are connected in the same way as unshielded network cables. 3. Put the network cable through waterproof PG connectors. Connect the RJ45 connector to the ETH/PoE interface on the AP and secure the waterproof PG connector. See figures b, c, and d. Figure 2-11 Connecting network cables NOTE l The network cables used are shielded straight-through cables. l Ensure that the RJ45 connector is correctly connected to the AP. Otherwise, the network cable may be damaged. Before removing the network cable from the AP, remove the waterproof PG connector first and then remove the RJ45 connector. l The cable cannot exceed 100 meters. 2.6.3 Connecting Ground Cables Grounding is a key step in device installation. The ground cable of a device must be correctly connected to protect the device from lightning, electromagnetic interference, and electrostatic charges. Outdoor APs support built-in surge protection on all interfaces, but the surge protection works only when the outdoor APs are grounded. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 33 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation Requirements for laying out ground cables The ground cables must be connected to a group of ground bars. The bend radius of the ground cables must be larger than or equal to five times the cable diameter. The ground cables must be buried underground or routed indoors and cannot be led into the equipment room aerially. Both ends of the external conductor of the coaxial cable and those of the shield layer of the shielded cable should have good electric contact with the metal shell of the equipment they connect to. Ground cables must be separated from signal cables to reduce interference between them. Do not add any switch or fuse on the ground cable. Do not use another device for an electrical connection with the ground cable. All metal components in the shell must be securely connected to the ground terminal. Ground cable connections 1. Cut the ground cable into a proper length and use the M4 OT terminal to connect to the AP. The OT terminal used to connect to the ground terminal depends on site requirements. NOTE To tighten the screws with a torque on the ground bar, l M4: 1.4N•m. l M6: 4.8N•m. l M8: 12N•m. 2. The equipment functions properly when the ground resistance is less than 10 ohms. Grounding shielded network cables Using shielded network cables can improve surge protection performance of the AP. To connect the cable, cut the shield layer open, connect the cable to the ground clip, and wrap the cable with waterproof and ESD tapes. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 34 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation 1. Determine the position for installing the ground clip on the cable based on the actual cable route. 2. Use a utility knife to strip the sheath off the network cable for about 32 mm (1.26in.) to expose the shield layer. NOTICE Do not damage the shield layer when stripping the sheath off the cable. 3. Install the ground clip on the shield layer of the cable, and then use a screwdriver to tighten the screws on the ground clip. (1) Ground cable 4. Issue 03 (2015-05-18) (2) Ground clip (3) Network cable Wrap three layers of waterproof tape and three layers of polyvinyl chloride (PVC) insulation tape at the ground clip. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 35 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation NOTICE l Wrap the tape around the clip from bottom up, then from top down, and finally from bottom up. Do not cut the tape until all the three layers of the tape are already wrapped. When wrapping tape, be sure that each layer of tape overlaps more than 50% of the preceding layer. l The degree between the ground cable and the network cable cable is not greater than 15°. When the network cable is routed vertically, the ground cable must be routed downwards. (1) Waterproof tape 5. (2) PVC insulation tape (3) Network cable (4) Ground cable Connect the ground cable to an external ground bar. 2.6.4 Installing Outdoor Antennas Two types of outdoor antennas are available: directional outdoor antenna and omnidirectional outdoor antenna. Omnidirectional antennas can be directly installed on APs. Installing a directional outdoor antenna against a pole Pay attention to the following points when installing a directional antenna: 1. An outdoor antenna must be installed on a pole with a diameter of 30 mm to 50 mm and the thickness must be at least 2.5 mm. A 50 mm diameter pole made of round steel is usually used. 2. Weld the lightning rod on the top of the antenna pole. 3. Install the antenna pole on a parapet or concrete bed on the roof of the building. 4. Use a 40 mm x 4 mm flat steel to connect the antenna pole to an earth mat. 5. Secure the directional outdoor antenna on the pole with an antenna support. 6. Keep the pole vertical to the ground during the installation. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 36 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation See Figure 2-12 below for how a directional outdoor antenna is installed on a pole. If the roof of the building is surrounded by parapets of no less than 1.2 m high, fix the pole on a parapet with expansion screws, and then fix the directional outdoor antenna on the pole with an antenna support. If the roof of the building is surrounded by parapets of less than 1.2 m high, fix the pole on a parapet and on the ground with expansion screws, and then fix the directional outdoor antenna on the pole with an antenna support. If there is no parapet around the roof, fix the pole on the ground or a concrete bed with expansion screws and steel wires, and then fix the directional outdoor antenna on the pole with an antenna support. Figure 2-12 Installing a directional outdoor antenna against a pole Lightning rod Antenna support Outdoor directional antenna Parapet Pole Steel w Flat steel Connected to the earth mat Parapet height > 1.2 m Parapet height < 1.2 m Concr bed No parapet Figure 2-13 shows outdoor AP installation scenarios. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 37 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation Figure 2-13 Outdoor AP installation scenarios Installing an omnidirectional outdoor antenna against a pole Pay attention to the following points when installing an omnidirectional antenna: 1. An outdoor antenna must be installed on a pole with a diameter of 30 mm to 50 mm and the thickness must be at least 2.5 mm. A 50 mm diameter pole made of round steel is usually used. 2. The top of pole must be aligned with the hose clamp at the bottom of the antenna. 3. The antenna must be installed at a proper height to provide sufficient signal coverage, and the top of the antenna must be within the 45 degrees protection angle of the lighting rod. 4. Do no weld a lightning rod directly on the antenna pole (there should not be metal subjects within 1 m around an omnidirectional antenna). Instead, install an independent lightning rod between two omnidirectional antenna poles. Adjust the height of the lightning rod to ensure that the omnidirectional antennas are covered in the protection angle. Figure 2-14 shows installation of an omnidirectional outdoor antenna. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 38 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation Figure 2-14 Installing an omnidirectional outdoor antenna Lightning rod Protection angle Omnidirectional antenna >1.0m Hose clamp Antenna pole NOTE If antennas are installed on a metal pole such as a steel pole, you do not need to install a lightening rod, as shown on the right in Figure 2-14. 2.7 Installing the Security Lock There is a security slot on the AP. You can lock the AP to an immovable object to prevent the AP against theft. The detailed procedures are as follows: 1. Fasten the cable of the security lock to an immovable object around. 2. Insert the security lock into the security slot and lock it. Console/RSS I Default Security lock Lock hole Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 39 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 2 AP Installation NOTE You need to purchase the security lock separately. 2.8 Checking the AP After Installation Table 2-4 shows the items to be checked after AP installation is complete. Table 2-4 AP installation checklist No. Check Item The AP is installed by strictly following the design draft. The installation position meets space requirements, with maintenance space reserved. The AP is securely installed. Waterproof caps are installed on idle interfaces and securely fastened. The power cables and PGND cables are intact and not spliced. Terminals of the power cables and PGND cables are welded or cramped firmly. All power cables or PGND cables are not short-circuited or reversely connected and must be intact with no damage. The power cables and ground cables are separated from other cables and bundled separately. The working ground, protection ground, and surge protection ground share the same group of ground bars. Connectors of signal cables are complete, intact, and tightly connected. The signal cables are not damaged or broken. 10 Labels on cables, feeders, or jumpers are clear and correct. 2.9 Powering on the AP After the AP installation is complete, observe indicators on the AP to determine the system running status. For details, see 1.2 Indicator Description. NOTE Do not frequently power on and off an AP. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 40 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 3 Logging In to the AP Logging In to the AP About This Chapter After an AP is powered on, you can log in to the AP using the following method: Version Telnet server STelnet server V200R003C00 and earlier versions Enable Enable V200R005C00 and later versions Disable Enable 3.1 Logging In to the AP Through the Console Port 3.2 Logging In to the AP Using STelnet 3.3 Logging In to the AP Using Telnet 3.4 Logging In to the AP Using a Web Client Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 41 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 3 Logging In to the AP 3.1 Logging In to the AP Through the Console Port This section describes how to log in to the AP through the console port. After logging in to the AP, you can configure the AP using commands. 1. Connect a PC to the AP using a console cable. Connect the RJ45 connector to the console port of the AP and the DB9 connector to the serial port of a PC. NOTE If your PC's operating system provides terminal simulation software (like HyperTerminal in Windows 2000/XP), you do not need to install additional terminal simulation software. If the PC runs on an operating system without terminal simulation software (like Windows 7), install thirdparty terminal simulation software on the PC by referring to user manual or online help. 2. Start the terminal simulation software, create a connection, select a serial port, and set communication parameters as follows. l Bits per second (B): 9600 l Data bits (B): 8 l Parity (P): None l Stop bits (S): 1 l Flow control (F): None 3. Press Enter until the command line prompt of the user view, such as, is displayed. Then, you enter the user configuration interface. You can run commands to configure the AP. Enter a question mark (?) whenever you need help. 3.2 Logging In to the AP Using STelnet This section describes how to log in to the AP using STelnet. After logging in to the AP, you can configure the AP using commands. Before logging in to the device through STelnet, complete the following tasks: Starting the device properly Preparing network cables used to connect device interfaces. Configuring the PC's IP address and subnet mask. The IP address must be on the network segment 169.254.0.0/16 but cannot be 169.254.1.1. 169.254.1.100 is recommended. The subnet mask is 255.255.0.0. NOTE l Ensuring that the IP address 169.254.1.1 and subnet mask 255.255.0.0 have been configured on VLANIF 1 of the device before the delivery, and GE0/0/0 has been added to VLAN 1 by default. l Before the device is delivered, the STelnet service has been configured on the device. The STelnet interface number is 22, and the default user name and password are respectively admin and admin@huawei.com. Use the SSH client software to log in to the device through STelnet from a terminal. The third-party software PuTTY is used as an example here. 1. Issue 03 (2015-05-18) After the device is powered on, connect the PC's network interface to GE0/0/0 of the device using network cables. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 42 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 3 Logging In to the AP NOTE Ping 169.254.1.1 from the PC to check whether the device can be pinged successfully. If the ping operation fails, check whether the PC's IP address is correct or replace the network cable. 2. Use the PuTTY software to log in to the device, enter the device IP address, and select the SSH protocol type. Figure 3-1 PuTTY Configuration page 3. Click Open. Enter the user name and password at the prompt, and press Enter. You have logged in to the device. (The following information is only for reference.) login as: admin Sent username "admin" admin@169.254.1.1's password: NOTE It is recommended that you change the initial user name and password after login. 3.3 Logging In to the AP Using Telnet Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 43 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 3 Logging In to the AP This section describes how to log in to the AP using Telnet. After logging in to the AP, you can configure the AP using commands. NOTE The Telnet protocol poses a security risk, and therefore the STelnet V2 protocol is recommended. 1. Connect a PC to the ETH/PoE interface of the AP using a network cable. 2. Configure a static IP address for the PC. The IP address must be in the same network segment as the AP's IP address. After completing the configuration, ping the AP's IP address from the PC. If the ping operation succeeds, the connection is set up successfully. If the ping operation fails, check whether the network cable is faulty. NOTE l The IP address 169.254.1.1 and subnet mask 255.255.0.0 have been configured on VLANIF 1 of the AP before the delivery, and GE0/0/1 has been added to VLAN 1 by default. l If the AP working in Fit AP mode is online on the AC, the DHCP server automatically assigns an IP address to the AP. You can remotely log in to the AC on a local terminal and run the following command to check the AP's IP address: l For V200R005C30 and earlier versions: display ap-run-info id ap-id l For V200R006C00: display ap run-info ap-name ap-name 3. Enter the command line interface on the PC. For example, in Windows XP, choose Start > Run and enter cmd in the displayed dialog box. 4. Use Telnet to log in to the AP. 5. Enter the default user name and password. The default user name is admin, and the default password is admin@huawei.com. If the user view is displayed, you have logged in successfully. You are advised to change the user name and password on your first login. NOTE You can run the quit command to exit from the Telnet window. When the system fails to exit from the Telnet window: l If you logged in to the AP from an AC or a switch, press Ctrl+T to return to the AC or switch view. This operation does not affect AP services. l If you logged in to the AP from a PC, directly close the Telnet window. This operation does not affect AP services. 3.4 Logging In to the AP Using a Web Client Pre-configuration Tasks Before configuring users to log in to the AP using HTTP, complete the following task: Configure reachable routes between the terminal and the AP. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 44 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 3 Logging In to the AP NOTE l The web management system is enabled on the AP before delivery. The default IP address of the web management system is 169.254.1.1 and the mask is 255.255.0.0. The web management system provides a default user account, with the user name admin and password admin@huawei.com. You are advised to change the user name and password on your first login. Assign your PC an IP address on the same network segment as the default IP address of the web management system, and connect the PC to the GE interface. Start the web browser on the PC and visit http://169.254.1.1 to log in to the web management system. l You can only log in to the FAT AP using the web platform. Procedure Step 1 Open a web browser on a PC, and enter the management address in the format of http:// 169.254.1.1 in the address bar. Ensure that the PC and AC can communicate with each other. Then press Enter. Set the language, user name, and password. The HTTPS login URL is displayed in the address box indicating that the system has gone to the HTTPS login page. NOTE You can also enter https://IP address in the address box to log in to the AP using HTTPS. HTTPS ensures security of login information during login and security of data exchanged during subsequent operations. Step 2 Click Login or press Enter. The web system home page is displayed. You can manage and maintain the equipment. For details, see the Huawei Wireless Access Points Web-based Configuration. ----End Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 45 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 4 Hardware Failures Hardware Failures About This Chapter This section describes common methods for troubleshooting typical hardware faults. 4.1 An device Fails to Be Powered On 4.2 An Optical Interface Cannot Turn Up Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 46 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 4 Hardware Failures 4.1 An device Fails to Be Powered On Fault Description The SYS indicator of a device is off. Possible Causes The power sourcing equipment does not support the PoE function or is faulty. The power sourcing equipment is incorrectly configured (the PoE function is disabled or the power-off time range is improperly set). The line is faulty (the network cable or distribution frame is damaged). The AP is faulty. Troubleshooting Procedure 1. Check whether the power sourcing equipment supports PoE or is faulty. 2. Check whether the configuration on the power sourcing equipment causes PoE power supply errors, such as the PoE function is disabled or the power-off time range is incorrectly set. 3. Check whether the network cable or distribution frame is faulty. 4. If the device still cannot be powered on, the device itself is faulty. Contact Huawei technical support engineers or Huawei agent and ask them to replace the device. 4.2 An Optical Interface Cannot Turn Up Fault Description After an optical interface is connected to a remote device through an optical fiber, its LINK indicator is off. Possible Causes The optical fiber is faulty. The optical module on the optical interface cannot meet the requirements. Troubleshooting Procedure 1. Replace the optical fiber and optical module and check whether the optical interface can turn Up. Ensure that the optical module meets the following requirements. 2. Determine optical module attributes. l The optical module has passed Huawei certification. l The transmission speed of the optical module is the same as the interface speed. l The wavelength of the optical module is the same as that of the remote optical module. l The transmission distance of the optical module is suitable for the actual distance between the two devices. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 47 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 4 Hardware Failures NOTE l The transmission distance of an optical module is 10 km, 15 km, 20 km, 40 km, or 80 km. The optical modules with a longer transmission distance have a higher transmit power. If an optical module with a long transmission distance is used for short-distance transmission, the optical interface cannot turn Up because the transmit power is too high. The high transmit power may even burn the receiver of the remote optical module. To reduce the transmit power in this situation, use an optical attenuator between the optical module and optical fiber. l Optical modules with different speeds are available, for example, 155 Mbit/s, 622 Mbit/s, and 1.25 Gbit/s. It is recommended that you use an optical module with the same speed as the optical interface to ensure efficient optical transmission. 3. Issue 03 (2015-05-18) If the interface remains Down, contact Huawei technical support. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 48 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Appendix About This Chapter 5.1 On-site Cable Assembly and Installation 5.2 Environmental Requirements for Device Operation 5.3 Equipment Grounding Specifications 5.4 Engineering Labels for Cables 5.5 Guide to Using Optical Modules 5.6 Fault Tag Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 49 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix 5.1 On-site Cable Assembly and Installation 5.1.1 Cable Assembly Precautions Checking the Appearance of Cables If the cable jacket or insulation is visibly dirty, clean it before assembly. If the jacket or insulation of a cable has visible damage, irreparable scuffing, or other defects, do not use the cable. If the shield layer of a cable is damaged, do not use the cable. If the cable jacket or insulation cracks after the cable is bent or twisted, discard this cable and check whether other cables have the same problem. If other cables have the same problem, replace these cables. Checking the Appearance of Connectors Do not use connectors with visible defects, damage, rust or scuffing. Do not use connectors if their shells or pins have exposed part or uneven plating, or their pins are lost, broken, or bent. Do not use connectors that have dirt on their pins or in their jacks or if there are conductors between pins or between pins and the shell. Precautions for Assembly Use dedicated tools or tools delivered by Huawei and follow the methods given here during assembly. Hold terminals of cables instead of pulling the cables when installing or removing cable components. Take the following precautions when cutting or stripping cables: – Make cables slightly longer than necessary. – Coil cables longer than 2 m (6.56 ft) after cutting. Bind and fasten the coils using bundling ropes. The inner diameters of the coils should be larger than 20 times the outer diameters of the cables. – When stripping the jackets of cables, avoid damaging the shield layers (braid or aluminum foil), insulation, core conductors, and other jackets that do not need to be stripped. – After assembling cables, cut all visible cross sections of jackets to ensure that the cross sections are arranged neatly. – Do not touch the core conductors of cables with your hands. Terminate exposed conductors in a timely way after stripping off insulation so that the surface of the conductors does not become oxidized. Issue 03 (2015-05-18) Take the following precautions when crimping and connecting cables or connectors: Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 50 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix – The terminals and conductors should be connected tightly after they are crimped. They should not be moved or turned. – Cut all the exposed copper wires. – Try to avoid a second crimping of sleeves. – Keep all the conductors clean and aligned. NOTE The connectors, cables, and tools provided by different vendors may be different. The figures in this document are only for your reference. 5.1.2 Assembling Power Cables Assembling the OT Terminal and Power Cable Context Figure 5-1 shows the components of an OT terminal and a power cable. Figure 5-1 Components of an OT terminal and a power cable A Heat-shrinkable tubing B. Bare crimping terminal C. Insulation D. Conductor Procedure Step 1 Based on the cross-sectional area of the cable conductor, strip a length of insulation coating C to expose the conductor D of length L1, as shown in Figure 5-2. The recommended values of L1 are listed in Table 5-1. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 51 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-2 Stripping a power cable (OT terminal) NOTICE l When you strip a power cable, do not damage the conductor of the cable. l If the bare crimping terminal is not provided by Huawei, the value of L1 is 1 mm (0.04 in.) to 2 mm (0.08 in.) greater than the value of L. Table 5-1 Mapping between the cross-sectional area of the conductor and the value of L1 CrossSectional Area of Conductor (mm2(in.2)) Value of L1 (mm (in.)) Cross-Sectional Area of Conductor (mm2(in.2)) Value of L1 (mm (in.)) 1 (0.002) 7 (0.28) 10 (0.015) 11 (0.43) 1.5 (0.002) 7 (0.28) 16 (0.025) 13 (0.51) 2.5 (0.004) 7 (0.28) 25 (0.039) 14 (0.55) 4 (0.006) 8 (0.31) 35 (0.054) 16 (0.63) 6 (0.009) 9 (0.35) 50 (0.077) 16 (0.63) NOTE If you are proficient in assembling OT terminals and power cables, you can obtain the value of L1 by comparing the part to be crimped with the power cable. Step 2 Put the heat-shrinkable (A) tubing onto the bare crimping terminal, as shown in Figure 5-3. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 52 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-3 Putting the heat shrink tubing onto the bare crimping terminal Step 3 Put the OT terminal B onto the exposed conductor, and ensure that the OT terminal is in good contact with the insulation coating C, as shown in Figure 5-3. NOTICE After the conductor is fed into the OT terminal, the protruding part of the conductor, or L2 in Figure 5-3, must not be longer than 2 mm (0.08 in.). Step 4 Crimp the joint parts of the bare crimping terminal and the conductor, as shown in Figure 5-4. NOTE The shapes of crimped parts may vary with the crimping dies. Figure 5-4 Crimping the joint parts of the bare crimping terminal and the conductor (OT terminal) Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 53 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Step 5 Push the heat shrink tubing (A) towards the connector until the tube covers the crimped part, and then heat the tube by using a heat gun, as shown in Figure 5-5. Figure 5-5 Heating the heat shrink tubing (OT terminal) NOTICE Stop heating the shrink tubing when the connector is securely locked in the shrink tubing. Do not heat the shrink tubing too long to damage the insulation coating. ----End Assembling the JG Terminal and Power Cable Context Figure 5-6 shows the components of a JG terminal and a power cable. Figure 5-6 Components of a JG terminal and a power cable A. JG terminal B. Heat-shrinkable tube C. Insulation layer of a power cable D. Conductor of a power cable Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 54 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Procedure Step 1 Based on the cross-sectional area of the cable conductor, strip a part of the cable. The L-long conductor is exposed, as shown in Figure 5-7. The recommended values of L are listed in Table 5-2. NOTICE l When you strip a power cable, do not damage the conductor of the cable. l If the bare crimping terminal is not provided by Huawei, you can adjust the value of L as required. Figure 5-7 Stripping a power cable (JG terminal) Table 5-2 Mapping between the cross-sectional area of the conductor and the value of L Cross-Sectional Area of Conductor (mm2(in.2)) Value of L (mm(in.)) 16 (0.025) 13 (0.51) 25 (0.039) 14 (0.55) 35 (0.054) 16 (0.63) 50 (0.077) 16 (0.63) Step 2 Put the heat shrink tubing onto the bare crimping terminal, as shown in Figure 5-8. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 55 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-8 Putting the heat shrink tubing onto the bare crimping terminal Step 3 Put the bare crimping terminal onto the exposed conductor, and ensure that the bare crimping terminal is in good contact with the insulation of the power cable, as shown in Figure 5-8. Step 4 Crimp the joint parts of the bare crimping terminal and the conductor, as shown in Figure 5-9. Figure 5-9 Crimping the joint parts of the bare crimping terminal and the conductor (JG terminal) Step 5 Push the heat shrink tubing towards the connector until the tube covers the crimped part, and then heat the tube by using a heat gun, as shown in Figure 5-10. Figure 5-10 Heating the heat shrink tubing (JG terminal) Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 56 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix ----End Assembling the Cord End Terminal and the Power Cable Context Figure 5-11 shows the components of a cord end terminal and a power cable. Figure 5-11 Components of a cord end terminal and a power cable A. Cord end terminal B. Insulation layer of a power cable C. Conductor of a power cable Procedure Step 1 Based on the cross-sectional area of the cable conductor, strip a part of the insulation. The L1long conductor is exposed, as shown in Figure 5-12. The recommended values of L1 are listed in Table 5-3. NOTICE When you strip a power cable, do not damage the conductor of the cable. Figure 5-12 Stripping a power cable (cord end terminal) Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 57 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Table 5-3 Mapping between the cross-sectional area of the conductor and the value of L1 CrossSectional Area of Conductor (mm2(in.2)) Value of L1 (mm (in.)) Cross-Sectional Area of Conductor (mm2(in.2)) Value of L1 (mm (in.)) 1 (0.002) 8 (0.31) 10 (0.015) 15 (0.59) 1.5 (0.002) 10 (0.39) 16 (0.025) 15 (0.59) 2.5 (0.004) 10 (0.39) 25 (0.039) 18 (0.71) 4 (0.006) 12 (0.47) 35 (0.054) 19 (0.75) 6 (0.009) 14 (0.55) 50 (0.077) 26 (1.02) Step 2 Putting the cord end terminal onto the conductor, and ensure that the conductor is aligned with the edge of the cord end terminal, as shown in Figure 5-13. NOTICE After the conductor is fed into the cord end terminal, the protruding part of the conductor must not be longer than 1 mm (0.04 in.). Figure 5-13 Put the cord end terminal onto the conductor Step 3 Crimp the joint parts of the cord end terminal and the conductor, as shown in Figure 5-14. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 58 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-14 Crimping the cord end terminal and the conductor Step 4 Check the maximum width of the tubular crimped terminal. The maximum width of a tubular crimped terminal is listed in Table 5-4. Table 5-4 Maximum width of a tubular crimped terminal Cross-Sectional Area of Tubular Terminal (mm2(in.2)) Maximum Width of Crimped Terminal W1 (mm(in.)) 0.25 (0.0004) 1 (0.04) 0.5 (0.0008) 1 (0.04) 1.0 (0.0015) 1.5 (0.06) 1.5 (0.0023) 1.5 (0.06) 2.5 (0.0039) 2.4 (0.09) 4 (0.006) 3.1 (0.12) 6 (0.009) 4 (0.16) 10 (0.015) 5.3 (0.21) 16 (0.025) 6 (0.24) 25 (0.039) 8.7 (0.34) 35 (0.054) 10 (0.39) ----End 5.1.3 Assembling Ethernet Cables Assembling the Shielded RJ45 Connector and Ethernet Cable Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 59 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Context Figure 5-15 shows the components of an RJ45 connector and a shielded Ethernet cable. Figure 5-15 Shielded RJ45 connector and cable A. Jacket of connector B. Metal shell of connector C. Wire holder of connector D. Plug of connector E. Jacket of Ethernet cable F. Shield layer of Ethernet cable G. Twisted-pair wires Procedure Step 1 Fit the jacket of the connector onto the Ethernet cable, as shown in Figure 5-16. Figure 5-16 Fit the jacket of the connector onto the Ethernet cable Step 2 Remove a 30 mm (1.18 in.) long section of the jacket, cut off the nylon twine inside the jacket, and cut a no more than 5 mm (0.20 in.) cleft in the jacket, as shown in Figure 5-17. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 60 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix NOTICE l When you remove a section of the jacket, do not damage the shield layer of the twisted-pair cable. l When you remove the shield layer, do not damage the insulation of the twisted-pair cable. Figure 5-17 Removing the jacket of a twisted-pair cable (unit: mm (in.)) Step 3 Fit the metal shell onto the twisted-pair cable. The shield layer is covered by the metal shell, as shown in Figure 5-18. Figure 5-18 Fitting the metal shell onto the twisted-pair cable Step 4 Fit the metal shell onto the twisted-pair cable until the shield layer is covered completely. Along the edge of the metal shell, cut off the aluminum foil shield layer and ensure that there is no surplus copper wire. The exposed twisted-pair cable is about 20 mm (0.79 in.) long, as shown in Figure 5-19. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 61 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-19 Removing the shield layer of a twisted-pair cable (unit: mm (in.)) Step 5 Based on the colors, lead the four pairs of twisted-pair wires through the wire holder, as shown in Figure 5-20 and Figure 5-21. Figure 5-20 Leading wires through the wire holder G C Figure 5-21 Cable locations in a wire holder White-Orange Orange White-Green Green Blue White-Blue White-Brown Brown Step 6 Align the four pairs of cables in the holder, as shown in Figure 5-22. The connections between the wires and the pins are shown in Figure 5-23 and listed in Table 5-5. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 62 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-22 Four pairs of cables on a wire holder Figure 5-23 Connections between wires and pins White-Orange Orange White-Green Blue White-Blue Green White-Brown Brown Pin 8 Pin 1 Table 5-5 Connections between wires and pins (using a straight-through cable as an example) Issue 03 (2015-05-18) Matching Pins of Wires Wire Color White-Orange Orange White-Green Blue White-Blue Green White-Brown Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 63 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Matching Pins of Wires Wire Color Brown Step 7 Cut off the surplus cables along the lower edge of the wire holder, as shown in Figure 5-24. Figure 5-24 Cutting off surplus cables Step 8 Put the connector body onto the wire holder and turn the metal shell by 90°, as shown in Figure 5-25. NOTE Ensure that the wire holder is in good contact with the connector body. Figure 5-25 Put the connector body onto the wire holder Step 9 Push the metal shell towards the connector body until the wire holder and the connector body are engaged completely. Crimp the connector, as shown in Figure 5-26. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 64 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-26 Crimping the connector Step 10 Push the jacket towards the metal shell until the metal shell is covered. This completes the assembly of one end of the cable, as shown in Figure 5-27. Figure 5-27 Pushing the metal shell Step 11 To complete the assembly of the other end, repeat Step 1 through Step 10. ----End Assembling an Unshielded RJ45 Connector and Ethernet Cable Context Figure 5-28 shows the components of an unshielded RJ45 connector and cable. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 65 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-28 Components of an unshielded RJ45 connector and cable A. Plug of connector B. Jacket C. Twisted-pair wires Procedure Step 1 Remove a 16-mm (0.63 in.) long section of the jacket, as shown in Figure 5-29. NOTICE When you remove the shield layer, do not damage the insulation of the twisted-pair cable. Figure 5-29 Removing the jacket of a twisted-pair cable (unit: mm (in.)) Step 2 Align the four pairs of wires and cut the ends neatly, as shown in Figure 5-30. The connections between the wires and the pins are listed in Table 5-6. Figure 5-30 Connections between wires and pins (unit: mm (in.)) Pin 8 Pin 1 Issue 03 (2015-05-18) White-Orange Orange White-Green Blue White-Blue Green White-Brown Brown 16 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 66 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Table 5-6 Connections between wires and pins (using a straight-through cable as an example) Matching Pins of Wires Wire Color White-Orange Orange White-Green Blue White-Blue Green White-Brown Brown Step 3 Feed the cable into the plug, and crimp the connector, as shown in Figure 5-31. NOTE When inserting the cable, check from the side or bore of the plug to ensure that the cable is completely seated in the plug. Figure 5-31 Crimping the connector Step 4 To complete the assembly of the other end, repeat Step 1 through Step 3. ----End Checking the Appearance of Contact Strips Context Issue 03 (2015-05-18) To ensure proper contact between the crimped wires and the wire conductors, the heights and sizes of the contact strips must be standard and the same. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 67 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix The contact strips must be parallel to each other, with an offset less than ± 5°. The top margin of a strip must be parallel to the axis of the connector, with an offset less than ± 10°. To ensure conduction, the surface of the contact strips must be clean. The contact strips must be in good contact with the RJ45 socket. The plastic separators must remain intact and be aligned. The contact strip blade must extend beyond the ends of the wires. The ends of the wires must be in contact with the edge of the RJ45. The distance between them must be less than 0.5 mm (0.02 in.). Procedure Step 1 Hold the crimped connector, with the front side facing you, and check whether the contact strips are of the same height. The height should be 6.02 ± 0.13 mm (0.237 ± 0.005). If a measuring tool is not available, you can compare the connector with a standard connector. Figure 5-32 shows an unqualified piece, and Figure 5-33 shows a qualified piece. NOTE All unqualified pieces must be crimped again. Figure 5-32 Contact strips of different heights Figure 5-33 Contact strips of the same height Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 68 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Step 2 Hold an RJ45 connector and turn it 45°. Observe the top edges of the metal contact strips. Figure 5-34 shows an unqualified piece. Figure 5-34 Unparallel contact strips of different heights Step 3 Check whether the contact strips are clean. If they are not clean and the dirt cannot be removed, replace it with a new RJ45 connector. Figure 5-35 shows an unqualified piece. Figure 5-35 Dirt on a contract strip Step 4 Check whether the contact strips and the plastic separators are well aligned and intact. If a separator is skew and cannot be fixed, replace it with a new RJ45 connector. Figure 5-36 shows an unqualified piece. Figure 5-36 Skew plastic separators Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 69 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Step 5 Hold the connector with the side facing towards you, and check whether you can see the crosssections of the wires. Ensure that the ends of the wires are in good contact with the edge of the RJ45, and that the contact strip blade extends beyond the ends of the wires and is crimped with the wires. If not, replace the connector. Figure 5-37 shows an unqualified piece. Figure 5-37 Wires not in good contact with the edge of the RJ45 ----End Testing the Connection of Assembled Cables Context Huawei provides two types of Ethernet cables: straight-through cables and crossover cables. Straight-through cables are connected in a one-to-one manner. They are used to connect terminals such as a computer or switch to network devices. Table 5-7 lists the connections of core wires in a straight-through cable. Table 5-7 Connections of core wires in a straight-through cable Issue 03 (2015-05-18) RJ45 Connector 1 RJ45 Connector 2 Core Wire Color Twisted or Not Orange Twisted Orange-White Green Green-White Blue Blue-White Brown Brown-White Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. Twisted Twisted Twisted 70 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Crossover cables are connected in a crossover manner. They are used to connect terminals such as two computers or switches. Table 5-8 lists the connections of core wires in a crossover cable. Table 5-8 Connections of core wires in a straight crossover cable RJ45 Connector 1 RJ45 Connector 2 Core Wire Color Twisted or Not Orange Twisted Orange-White Green Green-White Blue Blue-White Brown Brown-White Twisted Twisted Twisted Figure 5-38 shows the pins of an RJ45 connector. Figure 5-38 Pins of an RJ45 connector Pin8 Pin1 Procedure Step 1 Feed both connectors of the cable into the ports of the cable tester. Step 2 After the connectors are properly inserted, turn on the tester. If the indicators from 1 to G turn on simultaneously, you can infer that the pins work normally and the wires are correctly connected. NOTE Turn the switch to the S position to slow down lighting of the indicators so that you can see the indicators more clearly, as shown in Figure 5-39. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 71 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-39 Testing the conduction and connections of wires Step 3 Gently shake the connector and repeat Step 2 to check whether the metal contact strips are in good contact with the core wires and Ethernet ports, as shown in Figure 5-40. Figure 5-40 Checking the reliability The procedure for testing a crossover cable is the same as that for testing a straight-through cable except for the sequence in which the indicators turn on. You need to refer to the wire connections of a crossover cable. The Ethernet cable is qualified if the indicators turn on in the following sequence: At the master (left) section of the tester, the indicators turn on in the sequence of 1-8-G. At the slave (right) section of the tester, the indicators turn on in the sequence of 3-6-1-4-5-2-7-8-G. Otherwise, the Ethernet cable is unqualified. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 72 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix NOTE If a tester is not available, you can use a multimeter to perform a simple test, as shown in Figure 5-41. Figure 5-41 Testing the connection of an Ethernet cable ----End 5.1.4 Installing Cable Accessories Precautions for Installing Cable Accessories Tools NOTE The illustrations in this document may differ from actual situations, but the installation methods remain the same. For example, in this document, the adapters of cable connectors have separate interfaces. In the actual situation, the adapters may have interfaces fixed on equipment. Use dedicated tools provided or specified by Huawei and follow the installation procedure described here. Bending Radius Unless otherwise specified, bending radiuses (R) of cables or fibers must meet the requirements listed in Table 5-9. Table 5-9 Bending radiuses of cables or fibers Issue 03 (2015-05-18) Cable or Fiber Bending Radius (R) Ordinary cable In normal cases, R ≥ 2d. When the cable is connected with a connector, R ≥ 5d. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 73 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Cable or Fiber Bending Radius (R) Fiber R ≥ 40 mm (1.57 in.); Bending angle > 90° NOTE The letter d indicates the diameter of a cable or fiber. Precautions for Installation Hold the terminals of cables instead of pulling the cables when installing or removing the cable components. Do not insert a connector forcibly when the connector is blocked. Pull out the connector by using a dedicated tool. Install the connector again after you check that the pins are inserted properly. Before tightening screws on cable connectors, ensure that the connectors are properly connected to their adapters. Tighten the screw with appropriate force using a flat-head or Phillips screwdriver instead of bare hands or an electric screwdriver. If the screw cannot be screwed into the tapped hole, find out the reason and try again. Do not screw it with too much force, or the screw or adapter may be damaged. When removing densely aligned cables or fiber connectors, use dedicated pliers such as cable-pulling pliers and fiber-pulling pliers. Do not twist, bend, stretch, or extrude fibers during installation. Cover the fiber connectors that are not in use by using dustproof caps. Remove the dustproof caps before using the fiber connectors. Requirements for Cable Routing To protect cables, remove the burrs in the cable through-holes or install protective rings in the holes. To ease the connection and to avoid stress, keep slack at cable joints. After connecting multiple cables to a connector that has multiple interfaces, keep the cables slack to avoid stress generation. Bind or clean cables gently because cable distortion affects signal quality. Keep cables away from moveable components such as doors. Sharp objects must not be touched in cable wiring to ensure that cables are not damaged. To protect power cables, power cables of the active and standby power modules are laid separately. Installing Power Adapters Installing the OT Terminal Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 74 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Procedure Install an OT terminal. 1. Align the hole of the OT terminal (conductor upward) with a connecting hole, as shown in Figure 5-42. Figure 5-42 Aligning the OT terminal with a connecting hole NOTE When you install an OT terminal, the crimping sleeve is installed as shown in Figure 5-43, where A is correct and B is wrong. Figure 5-43 Installing an OT terminal, showing the orientation of crimping sleeve 2. Issue 03 (2015-05-18) Place the spring washer and flat washer in turn, mount a matching screw, and fasten it clockwise, as shown in Figure 5-44. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 75 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-44 Installing two terminals back to back NOTICE Ensure that the OT terminal is not in contact with other terminals or metal components. 3. Move the cable slightly and ensure that it is securely connected, as shown in Figure 5-45. Figure 5-45 Installed OT terminal Install two OT terminals on a post. Before you install two OT terminals on a post, ensure that the two terminals can be installed on the post and that the electrical connecting pieces have a large contact area. Two OT terminals can be installed using any of these methods: – Bend the upper OT terminal at a 45- or 90-degree angle, as shown in Figure 5-46. – Cross the two terminals, as shown in Figure 5-47. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 76 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-46 Bending the upper OT terminal at a 45- or 90-degree angle Figure 5-47 Crossing two terminals NOTICE If the two terminals are different in size, place the smaller one above the bigger one. A maximum of two terminals can be installed on a post. To remove an OT terminal, loosen the screw in the counterclockwise direction. ----End Installing the Cord End Terminal Procedure Step 1 Hold a cord end terminal upright and place it on a terminal jack, as shown in Figure 5-48. To ensure bump contact and dense connection, place the plain side of the terminal outwards. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 77 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-48 Placing a terminal on a terminal jack vertically Step 2 Insert the terminal into the jack vertically, and fasten the terminal by turning the matching screw in the clockwise direction, as shown in Figure 5-49. Figure 5-49 Feeding the terminal into the jack NOTICE l Ensure that the exposed section of the terminal should be less than 2 mm (0.079 in.) in length. l Do not press the insulation of the terminal. l Insert only one terminal into one jack. Step 3 Move the cable slightly and ensure that it is securely connected. Step 4 Before you remove a cord end terminal, loosen the screw in the counterclockwise direction. ----End Installing Ethernet Adapters Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 78 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Installing a Shielded Ethernet Connector Procedure Step 1 Hold the male and female connectors, with the male connector facing the female connector, as shown in Figure 5-50. Figure 5-50 Holding the male and female shielded connectors Step 2 Insert the male connector into the female connector, as shown in Figure 5-51. Figure 5-51 Feeding the male shielded connector into the female shielded connector Step 3 When you hear a click, the cable connector is completely inserted in the port. (The clip on the cable connector pops up to fix the connector in the port.) Pull the connector slightly and ensure that it is securely connected, as shown in Figure 5-52. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 79 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-52 Installed shielded Ethernet connector Step 4 To remove an Ethernet connector, press the locking key and pull out the connector, as shown in Figure 5-53. Figure 5-53 Removing an shielded Ethernet connector ----End Installing an Unshielded Ethernet Connector Procedure Step 1 Hold the male and female connectors, with the male connector facing the female connector, as shown in Figure 5-54. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 80 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-54 Holding the male and female unshielded connectors Step 2 Feed the male connector into the female connector, as shown in Figure 5-55. Figure 5-55 Feeding the male connector into the female unshielded connector Step 3 A crisp click indicates that the connector is locked by the locking key. Pull the connector slightly and ensure that it is securely connected. Figure 5-56 shows an installed Ethernet connector. Figure 5-56 Installed unshielded Ethernet connector Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 81 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Step 4 To remove an Ethernet connector, press the locking key and pull out the connector, as shown in Figure 5-57. Figure 5-57 Removing an unshielded Ethernet connector ----End Installing Fiber Connectors Context NOTICE l After you remove the dustproof cap, ensure that the fiber pins are clean and install them as soon as possible. l When you disassemble fiber connectors, you must use a dedicated tool if the connectors are densely installed. Cleaning Fiber Connectors Procedure Step 1 Clean the pins of a fiber connector by using lint-free cotton and alcohol. Step 2 Clean the pins again by using dust-free cotton. If necessary, clean the pins by using an air gun. Ensure that the pins are free from any fiber or debris. ----End Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 82 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Installing an FC Fiber Connector Procedure Step 1 Remove the dustproof cap of the FC connector and store it for future use. Step 2 Align the core pin of the male connector with that of the female connector, as shown in Figure 5-58. Figure 5-58 Aligning the male connector with the female connector Step 3 Align the male connector with the female connector and gently push the male connector until it is completely seated in the female connector, as shown in Figure 5-59. Figure 5-59 Feeding the male connector into the female connector Step 4 Fasten the locking nut in the clockwise direction and ensure that the connector is securely installed, as shown in Figure 5-60. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 83 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-60 Fastening the locking nut Step 5 To disassemble an FC fiber connector, loosen the locking nut counterclockwise, and gently pull the male connector, as shown in Figure 5-61. Figure 5-61 Disassembling an FC fiber connector ----End Installing an LC Fiber Connector Procedure Step 1 Remove the dustproof cap of the LC fiber connector and store it for future use. Step 2 Align the core pin of the male connector with that of the female connector, as shown in Figure 5-62. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 84 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-62 Aligning the male connector with the female connector Step 3 Align the male connector with the fiber adapter and gently push the male connector until it is completely seated in the fiber connector, as shown in Figure 5-63. Figure 5-63 Feeding the male connector into the female connector Step 4 A clicking sound indicates that the male connector is locked, as shown in Figure 5-64. Figure 5-64 Installed LC connector Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 85 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Step 5 To disassemble an LC fiber connector, press the locking nut to release the locking clips from the bore, and gently pull the male connector, as shown in Figure 5-65. Figure 5-65 Disassembling an LC fiber connector ----End Installing the SC Fiber Connector Procedure Step 1 Remove the dustproof cap of the SC fiber connector and store it for future use. Step 2 Align the core pin of the male connector with that of the female connector, as shown in Figure 5-66. Figure 5-66 Aligning the male connector with the female connector Step 3 Feed the fiber connector into the female connector, with your fingers holding the shell of the fiber connector (not the pigtail). When you hear a click, the fiber connector is secured by the Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 86 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix clips (internal parts, not illustrated in the figure). Pull the fiber connector gently. If the connector does not loosen, the installation is complete. See Figure 5-67. Figure 5-67 Installed SC fiber connector Step 4 To disassemble an SC fiber connector, hold the shell of the connector (do not hold the fiber) and gently pull the connector in the direction vertical to the adapter. Unlock the male connector, and then separate it from the shell, as shown in Figure 5-68. Figure 5-68 Disassembling an SC fiber connector ----End Installing an MPO Connector Procedure Step 1 Remove the dustproof cap of the MPO fiber connector and store it for future use. Step 2 Align the core pin of the male connector with that of the female connector, as shown in Figure 5-69. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 87 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-69 Aligning the male connector with the female connector Step 3 Hold the shell labeled "PUSH" and feed the male connector into the female connector until you hear a clicking sound. The male and female connectors are securely installed, as shown in Figure 5-70. Figure 5-70 Installed MPO fiber connector Step 4 To disassemble an MPO fiber connector, hold the shell labeled "PULL" and remove the male connector, as shown in Figure 5-71. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 88 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-71 Disassembling an MPO fiber connector ----End 5.1.5 Replacing the Mold of the Crimping Pliers Procedure Step 1 Hold the handles of a pair of COAX crimping tools. Loosen the two fastening screws in the counterclockwise direction, as shown in Figure 5-72. Figure 5-72 Loosening two fastening screws Step 2 Hold the handles of the COAX crimping tools to open the self-locking mechanism. The jaw of the COAX crimping tools opens automatically, as shown in Figure 5-73. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 89 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-73 Pliers jaw opening automatically Step 3 Remove the mould from the COAX crimping tools, as shown in Figure 5-74. Figure 5-74 Removing the mould from the COAX crimping tools Step 4 Place the mould to be installed into the jaw of the COAX crimping tools and align the screw holes, as shown in Figure 5-75. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 90 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-75 Installing a new mould in the COAX crimping tools NOTICE Keep the short side of the mould inwards and the long side outwards, with the teeth of the mould aligning from the larger size to the smaller size. Step 5 Hold the handles of the COAX crimping tools tightly to match the mould and the jaw completely. Align the screw holes, as shown in Figure 5-76. Figure 5-76 Aligning the screw holes Step 6 Hold the handles of the COAX crimping tools with one hand. Tighten the two fastening screws in the clockwise direction. Figure 5-77 and Figure 5-78shows the mould installed in the COAX crimping tools. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 91 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-77 Mold installed in the COAX crimping tools Figure 5-78 An installed mold ----End 5.2 Environmental Requirements for Device Operation 5.2.1 Environmental Requirements for an Equipment Room Requirements for Selecting a Site for an Equipment Room When designing a project, consider the communication network planning and technical requirements of the equipment. Also consider hydrographic, geological, seismic, power supply, and transportation factors. Construction, structure, heating and ventilation, power supply, lighting and fire fighting of the equipment room should be designed by specialized construction designers to suit the environmental requirements of devices. The equipment room should also follow local regulations concerning the industrial construction, environmental protection, fire fighting, and civil air defense. Construction must conform to government standards, regulations, and other requirements. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 92 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix The equipment room should be located at a place free from high temperature, dust, toxic gases, explosive materials, or unstable voltage. Keep the equipment room away from significant vibrations or strong noises, as well as power transformer stations. The specific requirements for selecting a site for equipment room are as follows: The room should be located at a distance of at least 5 km (3.11 mi.) from heavy pollution sources such as smelting and coal mines. It should be located at a distance of at least 3.7 km (2.30 mi.) from moderate pollution sources such as chemical, rubber, and galvanization factories. It should be located at a distance of at least 2 km (1.24 mi.) from light pollution sources such as packinghouses and tanyards. If these pollution sources cannot be avoided, ensure that the equipment room is upwind of the pollution sources. In addition, adopt a high-quality equipment room or protection products. The room should be located away from livestock farms, or in the upwind of the livestock farms. Do not use an old livestock room or fertilizer warehouse as the equipment room. The equipment room must be far away from the residential areas. The equipment room that is not far away from the residential areas must comply with equipment room construction standards to avoid noise pollution. The doors and windows of the equipment room must be closed to keep an airtight room. Using steel doors to ensure sound insulation is recommended. No cracks or openings are allowed on the walls or floors. The outlet holes on the walls or windows must be sealed. Walls must be constructed in the smooth, wear-resistant, dustproof principles and produce the effect of flame retardant, sound insulation, heat absorption, dust decrease, and electromagnetic shielding. The air vent of the room should be far from the exhaust of city waste pipes, big cesspools and sewage treatment tanks. The room should be in the positive pressure state to prevent corrosive gases from entering the equipment room and corroding components and circuit boards. The room should be located far away from industrial and heating boilers. It is recommended that the room be on or above the second floor. If this requirement cannot be met, the ground for equipment installation in the room should be at least 600 mm (23.62 in,) above the maximum flood level. The room should be at least 3.7 km (2.30 mi.) away from the seaside or salt lake. Otherwise, the equipment room should be airtight with cooling facilities. In addition, alkalized soil cannot be used as the construction material. Otherwise, equipment suitable for wet conditions must be used. The equipment room should be strong enough to resist winds and downpours. The room should be located away from dusty roads or sand. If this is unavoidable, the doors and windows of the equipment room must not face pollution sources. Do not place air conditioning vents near the equipment so that they blow directly on the equipment because condensation may be blown into the equipment. Do not use decorative materials that contain sulfur in the equipment room. Equipment Room Layout The equipment room is usually used to install mobile switching equipment, telecom transmission equipment and power supply equipment as well as other auxiliary equipment. To ensure easy maintenance and management, place the telecom equipment in different rooms. Figure 5-79 shows the layout of the equipment room. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 93 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-79 Layout of the equipment room Transmission room Control room Generator room Main communication equipment room Power distribution room Battery room Substation room Communication cable and optical cable Power cable The general layout principles of the equipment room are as follows: It should meet requirements for laying out and maintaining communication cables and power cables. It should reduce the cabling distance, which eases cable maintenance, reduces potential communication faults, and maximizes efficiency. Construction Requirements for the Equipment Room Table 5-10 shows the construction requirements for the equipment room. Table 5-10 Construction requirements for the equipment room Issue 03 (2015-05-18) Item Requirements Area The smallest area of the equipment room can accommodate the equipment with the largest capacity. Net height The minimum height of the equipment room should not be less than 3 m (9.84 ft). The minimum height of the equipment room is the net height below overhead beams or ventilation pipes. Floor The floor in the equipment room should be semi-conductive and dustproof. A raised floor with an ESD covering is recommended. Cover the raised floor tightly and solidly. The horizontal tolerance of each square meter should be less than 2 mm (0.08 in.). If raised floors are unavailable, use a static-electricity-conductive floor material, with a volume resistivity of 1.0 x 107 ohms to 1.0 x 1010 ohms. Ground this floor material or raised floor. You can connect them to ground using a one megohm current-limiting resistor and connection line. Load-bearing capacity The floor must bear loads larger than 150 kg/m2 (0.21 bf/in.2). Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 94 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Item Requirements Door and windows The door of the equipment room should be 2 m (6.56 ft) high and 1 m (3.28 ft) wide. One door is enough. Seal the doors and windows with dustproof plastic tape. Use double-pane glass in the windows and seal them tightly. Wall surface treatment Paste wallpaper on the wall or apply flat paint. Do not use pulverized paint. Cable trays Use cable trays to arrange cables. The inner faces of the cable trays must be smooth. The reserved length and width of the cable trays, and the number, position and dimensions of the holes must comply with the requirements of device arrangement. Water pipe Do not pass service pipes, drainpipes, and storm sewers through the equipment room. Do not place a fire hydrant in the equipment room, but place it in the corridor or near the staircase. Internal partition wall Separate the area where the equipment is installed from the equipment room door. The partition wall can block some outside dust. Installation position of the air conditioner Install air conditioner vents so that the air does not blow directly on equipment. Other requirements Avoid the proliferation of mildew, and keep out rodents (like mice). Figure 5-80 Internal partition wall inside the equipment room Equipment Room Environment Dust on devices may cause electrostatic discharge and result in poor contact for connectors or metal connection points. This problem can shorten the life span of devices and cause faults. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 95 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix The equipment room must be free from explosive, conductive, magnetically-permeable, and corrosive dust. Table 5-11 shows the requirement for dust concentration in the equipment room. Table 5-11 Requirements for dust particles in the equipment room Mechanical active material Unit Concentration Dust particle Particle /m3 ≤ 3x 104 (no visible dust accumulated on a workbench in three days) Suspending dust mg/m3 ≤0.2 Precipitable dust mg/m2·h ≤1.5 Description l Dust particle diameter ≥ 5 µm l Suspending dust diameter ≤ 75 µm l 75 µm ≤ precipitable dust diameter ≤ 150 µm Take the following measures to meet the requirements: Use dustproof materials for ground, wall, and ceiling construction. Use screens on the door and windows facing outside. The outer windows should be dustproof. Clean the equipment room regularly and clean the air filter monthly. Wear shoe covers and ESD clothes before entering the equipment room. Requirements for Corrosive Gases The room should be free from dusts and corrosive gases, such as SO2, H2S, and NH3. Table 5-12 shows the requirements for the corrosive gas concentration. Table 5-12 Requirements for corrosive gas concentration Issue 03 (2015-05-18) Chemical active material Unit Concentration SO2 mg/m3 ≤0.20 H2S mg/m3 ≤0.006 NH3 mg/m3 ≤0.05 Cl2 mg/m3 ≤0.01 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 96 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Take the following measures to meet the requirements: Avoid constructing the room near a place where the corrosive gas concentration is high, such as a chemical plant. Ensure the air intake vent of the room is in the prevailing upwind direction from the pollution source. Place batteries in different rooms. A professional service should monitor the corrosive gas conditions regularly. Requirements for ESD Prevention The absolute value of electrostatic voltage is less than 1000 V. Take the following measures to meet the requirements: Train operators about ESD prevention. Keep the correct humidity level in the equipment room to reduce the impact of static electricity. Lay out an ESD floor in equipment rooms. Wear ESD shoes and clothing before entering equipment room. Use ESD tools, such as wrist straps, tweezers, and pullers. Ground all conductive materials in the room, including computer terminals. Use ESD worktables. Keep non-ESD materials (such as common bags, foams, and rubbers) at least 30 cm (11.81 in.) away from boards and ESD-sensitive components. Electromagnetism Requirements for the Equipment Room All interference sources, inside or outside the equipment room, can cause equipment problems with capacitive coupling, inductive coupling, electromagnetic wave radiation, and common impedance (including grounding system) coupling. Prevent the interference using these approaches: Take effective measures against electrical interference from the power supply system. Do not use the working ground of the equipment as the same ground for surge protection. Separate them as far as possible. Keep the equipment far away from strong power radio transmitters, radar units, and highfrequency and high-current equipment. Use electromagnetic shielding if necessary. Requirements for Lightning Proof Grounding Table 5-13 shows the requirements for lightning proof grounding. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 97 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Table 5-13 Requirements for lightning proof grounding Item Requirements Capital construction l Use the reinforced concrete structure for the construction of the equipment room. l Install the lightning proof device like a lighting rod in the room. l The lightning proof ground shares the same grounding body with the protection ground of the room. Power cables leading in the equipment room need to be equipped with a surge arrester l After the low-voltage power cables are led into the room, install the surge arrester for the power cables in the AC voltage stabilizer and the AC power distribution panel (box). Ground the arrester nearby and correctly. l For the equipment room in the city, install the power supply arrester with the nominal discharging current no less than 20 kA. For the equipment room built in the suburbs subject to lightning strike, install the power supply arrester with the nominal discharging current larger than 60 kA. For the equipment room in the mountain areas easily subject to lightning strike, or in the separate high-rise buildings in the city, install the power supply arrester with the nominal discharging current larger than 100 kA. l The ground cable of the surge arrester should be a maximum of 1 m (3.28 ft) long. Grounding of DC power distribution l Connect the DC working ground (positive pole of the -48 V DC power supply or the negative pole of the 24 V DC power supply) with the indoor collective ground cable nearby. The total ground cable should meet the maximum load of the equipment. l The power equipment must have the DC working ground cable, which can connect the power equipment to the collective ground cable of the telecommunication site (or the protection ground bar of the equipment room). l Ground the devices and auxiliary devices in the room such as mobile base station, transmission, switching equipment, power supply equipment, and cable distribution frame properly. Connect all PGND cables to the collective protection ground bar. Connect all PGND cables in one equipment room to one protection ground bar. Equipotential connection l Apply joint grounding to the working ground and protection ground of devices, which means the two share one grounding network. l The cable tray, rack or shell, metal ventilation pipe, metal door or window of the equipment should be grounded for protection. General requirements for grounding l Do not connect the neutral line of the AC power cable with the protection ground of any telecom equipment in the equipment room. l Do not install the fuse or switch on the ground cable. l All ground cables should be as short as possible, and arranged directly. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 98 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide Item Requirements Grounding resistance l The grounding resistance must be lower than 1 ohm. 5 Appendix l The upper end of the grounding body should be at least 0.7 m (2.30 ft) over the ground. In cold areas, bury the grounding body below the frozen ground. l Measure the grounding resistance periodically to ensure effective grounding. Routing of signal l Do not arrange the signal cables overhead in the equipment room. All cable signal cables must be led into the site underground. l Use the cables with metal jacket or place them into the metal pipe if they come out/in the equipment room. l Ground the idle lines inside the cable in the equipment room. l Signal cables should be deployed on internal walls. Do not deploy outdoor aerial cables. l Keep signal cables away from power cables and surge protection devices. l Use the grounding ring or ground bar for the collective ground cable. Collective ground cable l Do not use aluminum cables as ground cables. Adopt measures to prevent electrification corrosion when connecting different metal parts together. l Use the copper busbar as the collective ground cable with the crosssectional area not less than 120 mm2 (0.19 in.2), or use the galvanized flat steel of the same resistance. Insulate the collective ground cable from the reinforcing steel bars of the building. Grounding leadin Issue 03 (2015-05-18) The grounding lead-in should be a maximum of 30 m (98.42 ft) long. Use the galvanized flat steel with cross-sectional area of 40 mm x 4 mm (1.58 in. x 0.158 in.) or 50 mm x 5 mm (1.97 in. x 0.197 in.). Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 99 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Item Requirements Grounding of the cabinet l All the devices including the surge protection device in the cabinet must be connected in an equipotential manner. The ground cables can be aggregated to the ground bar or surge protector socket first, and then the ground bar or surge protector socket is connected to the ground. l The resistance tested using a multimeter between the device ground terminals and ground bar cannot exceed 0.1 ohm. l The cabinet can be grounded using the protecting earthing (PE) wire of the electrical network in the building, zinc-coated angle steel, or main steel bar of the building. l If the cabinet is grounded using the PE wire of the electrical network, the grounding status can be checked using a multimeter. If the voltage between the PE wire and neutral wire is lower than 5 V and the voltage between the PE wire and live wire is about 220 V, the PE wire is grounded well. If the tested AC voltages are not within the ranges, the cabinet must be grounded in other ways. l The yellow-green ground cable contains multiple copper wires. The diameter is no smaller than 6 mm2 (0.0093 in.2) and the length cannot exceed 3 m (9.84 ft.). l Ground cables cannot be twisted with signal cables. l Antirust and anticorrosion measures must be taken on the ground terminals. l The fiber reinforcing rib can be directly connected to the ground bar of the cabinet. Before wrapping the reinforcing rib with insulation tape, cut a 0.5 m (1.64 ft.) segment from the reinforcing rib. Wrap the reinforcing rib with at least five layers of insulation tape. Keep the reinforcing rib at least 5 cm (1.969 in.) from the cabinet surface. 5.2.2 Requirements for Power Supply Requirements for AC Power Supply The AC power supply consists of power mains, uninterruptable power supply (UPS), and selfsupplied electric generator. In addition to meeting the requirements of the server load, the AC power supply must have a simple connection line, safe operation, flexible scheduling, and easy maintenance. The low-voltage power supply should have 3-phase, 5-wire mode or monophase 3-wire mode. This AC power supply should be 110 V/220 V, and the frequency is 50 Hz. The UPS should supply the same power and operate at the same phase as the power mains. The switching time between the UPS and mains should be less than 10 ms; otherwise, the networking devices will reboot or reset. For power distribution capacity in the equipment room, both the working current and fault current of the devices should be considered. Ensure that independent AC power supplies protect Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 100 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix independent devices. Configure the current-carrying capacity of the protection switch of the equipment room for more than that of the devices. Table 5-14 shows the voltage range of the AC power supply for the devices. Table 5-14 Voltage range of AC power supply Item Requirements AC power capacity to support the devices -10% to +5% of the rated voltage AC power capacity to support the power modules and important buildings -15% to +10% of the rated voltage Frequency of alternating current -4% to +4% of the rated value Voltage wave shape sine distortion Within 5% of the rated voltage The automated electric generator must have a standard interface that supports telecommunication protocol, remote telecommunication, monitoring, and control. AC power cables should meet the following specifications: AC neutral should have a conductor with the same cross section as the phase line. AC cables should have non-flammable insulation. The layout of AC cables should comply with local regulations. Low-voltage power distribution rooms should comply with local regulations. Recommendations for AC Power Supply The following shows recommendations for the AC power supply. If the voltage of the power mains that supply power directly to devices exceeds the rated voltage by -10% to 5%, or exceeds the voltage range that devices can support, a voltage regulating device or voltage stabilizing device is required. If the mains do not supply power for the device directly, or if the mains voltage exceeds the rated voltage by -15% to 10% or exceeds the input voltage range of the DC power supply, a voltage regulating device or voltage stabilizing device is required. An UPS or inverter power supply system is required to provide uninterrupted AC power to support the telecommunication load. If abnormalities occur on the mains, telecommunication servers should be equipped with a self-supplied electric generator to support the key telecommunication load. The capacity should be not less than 150% to 200% of the total uninterruptable power supply. Storage batteries are usually installed in a parallel connection of two groups. UPS storage batteries are generally installed in one group. The redundancy required for the UPS can rely on concatenation or parallel connection. When an inverter or a UPS is used, the active inverter is determined by the maximum power and a backup inverter is required. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 101 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Requirements for DC Power Supply The equipment room should receive stable and reliable DC power. Deploy the power equipment near the telecommunications equipment to make the DC feeder as short as possible. To reduce power consumption and installation cost, the loop voltage drop from the battery port to the equipment port should be less than 3.2 V. A large-scale enterprise can deploy an independent power supply system on each floor to supply power to the telecommunications equipment room on the respective floor. A medium-scale enterprise can use a power room and a battery room for centralized power supply or use distributed power supply systems. A small-scale enterprise can deploy an integrated power supply system in its equipment room but must take measures to prevent corrosive gases released from batteries from eroding circuit boards of telecommunications equipment. Table 5-15 shows the specifications for the DC power supply. Table 5-15 Specifications for the DC power supply Item Requirements DC power capacity to support the surge current Greater than 1.5 times the rated current Regulated voltage precision If the AC input voltage is in the range of 85% to 110% of the rated value, and the load current is in the range of 5% to 100% of the rated value, the output voltage of the rectifier ranges from -46.0 V to -56.4 V, with the regulated voltage precision less than or equal to 1%. Overshoot amplitude of switch on/off Integral value of the DC output voltage ±5% Peak noise voltage ≤200 mV Dynamic response The recovery time is less than 200 ms. The overshoot is in the range of the integral value of the DC output voltage ±5%. Recommendations for DC Power Supply The following shows recommendations for the DC power supply. Use distributed power supply mode. Use multiple DC power supply systems and put power equipment in multiple locations. Adopt a standard DC power supply system, and set the output voltage to the communications equipment within the required range. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 102 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Improving the reliability of the AC power supply system reduces the necessary capacity of storage batteries. For small offices, increase the capacity of storage batteries if it is difficult to enhance the reliability of the AC power supply system. The total capacity of the high-frequency switching rectifier must satisfy the power of the communication loading and battery charging. If there are 10 or fewer active rectifier modules, configure one backup module. If there are more than 10 active modules, configure one backup module for every 10 active modules. Install storage batteries in two or more groups. The capacity is determined by the duration for which the storage batteries must supply power. For most offices, the batteries should be able to supply power for at least one hour. 5.3 Equipment Grounding Specifications 5.3.1 General Grounding Specifications Table 5-16 shows the general grounding specifications. Table 5-16 General grounding specifications No. Description The working grounding and protection grounding, including the shielded grounding and the lightning-proof grounding of the cable distribution frame should share the same grounding conductor. The cable trays, shells, metal ventilation pipes, metal doors and windows in the equipment room should be grounded for protection. The metal parts of the equipment which are electrically floating in normal conditions should be grounded for protection. The ground cable must be connected securely to the protection ground bar of the equipment room. Do not use other equipment as part of the ground cable or electrical connection. 5.3.2 Grounding Specifications for an Equipment Room The grounding resistance of a comprehensive communication building should be less than or equal to one ohm. The grounding resistance of an ordinary communication office should be less than five ohms. The grounding resistance in an area where the earth resistance rate is high should be less than 10 ohms. 5.3.3 Grounding Specifications for Devices Table 5-17 shows the equipment grounding specifications. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 103 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Table 5-17 Equipment Grounding Specifications No. Description All communication devices and auxiliary devices (such as mobile base stations, transmission and switching devices, power supply devices) in the equipment room should be grounded for protection. Connect all protection grounding for various devices jointly to a general ground bar, and then to the same protection ground bar in the room together with the protection ground (PGND) of the device. The PGND of the equipment is shorted to the copper protection ground bar provided by the user. The short-circuiting cable used should be an alternating yellow and green plastic insulating one with copper core, with cross-sectional area greater than 25 sq. mm (0.039 sq. in.). There are grounding terminals and grounding lugs at the lower part of the front door, rear door and side panel of the cabinet, connected to the grounding terminals of the cabinet framework through connection cables with cross-sectional area no less than 1.6 sq. mm (0.002 sq. in.). Ensure that all metal components of the cabinet conduct well. No insulating coating should be sprayed on the connection part of the metal components. Connect the cabinets in the same row by fastening captive screws and gaskets on the top of the cabinets. Do not spray any coating into a rectangular area measuring 30 mm x 50 mm (1.18 in. x 1.97 in.) around the connection hole for a captive bolt. Measures to prevent rust and corrosion must be taken for this area. Zinc electroplating with iridescent yellow chromate conversion coating should be applied to the gasket and nut to ensure good electrical contact. When combining cabinets of the same type, short-circuiting cables are required to connect the ground busbars (if any) of the cabinets. The cross-sectional area of the short-circuiting cable is 6 sq. mm (0.009 sq. in.) and is no more than 300 mm (11.8 in.) long. Connect the two ends of the short-circuiting cable to the ground busbar terminals of neighboring cabinets and fix them firmly. 5.3.4 Grounding Specifications for Communications Power Supply Table 5-18 shows the grounding specifications for communication power supplies. Table 5-18 Grounding specifications for communication power supplies Issue 03 (2015-05-18) No. Description The inlet for the AC power cable at the equipment room should be equipped with a surge protection device (C-level) with a nominal discharge current no less than 20 kA. The protection ground for the power supply and that for communication equipment share the same grounding conductor. If the power supply and the equipment are in the same equipment room, use the same protection ground bar for them if possible. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 104 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix No. Description Use a surge protection circuit on the AC power interface. The positive of the -48 V DC power supply or negative pole of the 24 V DC power supply should be grounded at the output of the DC power supply. The working ground and protection ground of the DC power supply equipment should use the same grounding conductor with the protection ground of the switching equipment. If the power supply and equipment are in the same equipment room, use the same protection ground bar for them if possible. Add surge protection on the DC power interface. 5.3.5 Grounding Specifications for Signal Cables Grounding specifications for signal cables are shown in Table 5-19. Table 5-19 Grounding specifications for signal cables No. Description Equip the cable outdoors with a metal jacket, well grounded at both ends, or connect the ends of the metal jacket to the protection ground bar of the equipment room. For cables inside the equipment room, install surge protection devices at the interface to the equipment. The PGND cable for the surge protection devices should be as short as possible. The incoming and outgoing signal cables to and from the office and unused wires inside the cable should be grounded for protection. The Tone & Data Access (TDA) cable must pass through the Main Distribution Frame (MDF) with surge protective device (SPD) when going out of the office. The cable's shield layer should be connected to the protection ground of the MDF. The MDF should use the same grounding conductor with the cabinet. The signal cables should not be routed overhead. 5.3.6 Specifications for Laying Out Grounding Cables Table 5-20 shows the specifications for the ground cable. Table 5-20 Specifications for laying out ground cables Issue 03 (2015-05-18) No. Description The grounding wire should not run parallel to or twist around the signal cable. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 105 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix No. Description The ground cable cannot be routed overhead, but should be buried in the earth or arranged indoors. Do not connect two cables together to extend the PGND cable, or add any switch or fuse. The PGND cable should be an alternating yellow and green plastic insulating one with copper core. The neutral line of the AC power cable cannot be connected to the protection ground of transmission and communication equipment in the equipment room. The length of the PGND cable should not exceed 45 m (147.64 ft). The PGND cable should be as short as possible. 5.4 Engineering Labels for Cables An engineering label serves as an identifier for on-site installation and maintenance after the installation. Labels on the cables facilitate correct and orderly connection of cables, and easy maintenance after installation. Specialized for power cables and signal cables, the types of engineering labels are as follows: The signal cables include network cables, optical fibers, and user cables. The power cables include the AC power cables and DC power cables. NOTE Fill in the label according to the user's requirements if the user needs an integrated description of the label. Make a relevant statement in the self-check report. 5.4.1 Introduction to Labels Label Materials Features: Thickness: 0.09 mm (0.004 in.) Color: chalk white Material: polyester (PET) Ambient temperature: -29°C (-20.2°F) to +149°C (300.2°F) Compatible with laser printing and handwriting with markers Pass UL and CSA authentication Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 106 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Type and Structure Label for Signal Cables The label for signal cables is L-shaped with fixed dimensions, as shown in Figure 5-81. Figure 5-81 Label for signal cables To specify more clearly the position of a cable, use the dividing lines on the label. For example, there is a dividing line between the cabinet number and the chassis number, and another one between the chassis number and the slot number. The dividing line is 1.5 mm x 0.6 mm (0.06 in. x 0.02 in.) with the color of Pantone 656c (light blue). The cut dotted line helps to fold the label when affixed to the cable, and its size is 1 mm x 2 mm (0.04 in. x 0.08 in.). There is a mark "TO:" (upside down in the figure) at the lower right corner of the label. The mark is used to identify the opposite end of the cable on which the label is affixed. Power Cable Label The label for power cables should be attached to the identification plate on the cable ties that are attached to the cable. The identification plate has an embossed area 0.2 mm x 0.6 mm (0.008 in. x 0.02 in.) around (symmetric on both sides), and the area in the middle is for affixing the label, as shown in Figure 5-82. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 107 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-82 Power cable label Label Printing The contents can be printed or written on the labels. Printing is recommended for the sake of high efficiency and eye-pleasant layout. Template for Printing Use a template to print labels. You can obtain the template from the Huawei local office. The templates are made in Microsoft Word and the following requirements should be met: Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 108 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix When using the template, you can directly modify the contents of the template. The settings of centered characters, direction, and fonts should not be changed. When there are too many characters to be filled in, zoom out the characters, but make sure that the printouts are clear and legible. Merging Cells in the Template To merge two or more cells, do as follows: 1. Select Edit/Select All. 2. Select Format/Borders and Shading/Borders. Select Box tab and click OK. 3. Drag the mouse to select cells to be merged and select the Table/Merge Cells. Requirements on the Printer To print the labels, a laser jet printer must be used, although there is no restriction on the model of the printer. Before printing the label, set up the page and try printing. 1. Try printing on ordinary paper with both sides blank. Place the blank paper over the whole page of label paper, and check whether the page setup conforms to the label layout. 2. Make sure the printer properties, such as "paper size" and "direction", have been set correctly. l If the printout conforms to the sheet of labels, print the labels on the label paper. l If the printout does not conform, adjust the page setup and try printing again until the correct printout is produced. The method of adjusting the page setup is as follows. 1. Select File/Page Setup. 2. Select Layout and set Header and Footer as 0. 3. Select the Margins tab page. Select Left for Gutter Position and adjust the values of Top, Bottom, Left, and Right. NOTE If the warning prompt as shown in Figure 5-83 appears before printing, click Ignore to continue the printing. Figure 5-83 Warning prompt before printing After the page setup has been made correctly, save it for future use. This page setup is only necessary the first time you use the template to print the labels. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 109 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Requirements for Feeding the Printer The label paper consists of two layers and has undergone multiple processing procedures such as printing and cutting. No matter what model of printer you use, feed in the labels one page at a time. To avoid jamming the labels, never use the auto-feed mode. Feed in the label paper in the correct direction to ensure that the text is printed in a correct position. Requirements for the Printed Label Make sure that the printed labels satisfy the following requirements: All the printouts must be on the label, and nothing should be printed on the backing layer of the label page. Contents in the cells should be aligned in the center. In a single-line printout, the dividing lines and the mark "TO:" should not be covered by the printed characters. When the cells are merged and the printouts are made in multiple lines, avoid covering the mark "TO:" when printing the texts. Use the space bar to move the text to the next line. Writing Labels Writing Tools To make sure the printouts are clear and legible, use the black markers instead of ball-point pens to write the labels. In special cases, black ball-pens are allowed, although not recommended. Compared with ballpoint pens, water-proof markers are better. When writing with a ball-point pen, do not leave the oil on the label, which may contaminate the label and blur the words. NOTE The delivered marker has two nibs. Make sure to use the smaller nib to write the labels. Font For the sake of easy recognition and good appearance, the font in handwriting should be as close to a standard typeface (such as Times New Roman) as possible. Table 5-21 shows the standard typeface. Table 5-21 Standard typeface for handwriting Determine the size of characters based on the number of letters or digits and ensure that the characters are clear, distinct, and tidy. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 110 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Writing direction: The direction is shown in Figure 5-84: Figure 5-84 Writing direction of the characters on the label Attaching Labels After printing or writing the label, remove the label from the page and attach it to the signal cable, or the identification plate of the power cable. The methods for attaching labels are described in the following sections. Label for Signal Cables Choose the place to attach labels. The label is attached 2 cm (0.79 in.) from the connector on a signal cable. In special cases (for example, to avoid cable bending or affecting other cables), other positions are allowed to attach the labels. The rectangle part with characters is attached facing right or downward, as shown in Figure 5-85. The details are as follows: – The identification card is to the right of the cable in vertical cabling. – The identification card should be downward when you lay out the cable horizontally. Figure 5-85 Text area of the label Procedure for attaching labels Figure 5-86 shows the methods and procedures for attaching labels. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 111 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-86 Label for signal cables Power Cable Label Remove the label from the backing page, and attach it to the identification plate on the cable tie. The label should be attached to the rectangular flute on the identification plate, and attached to only one side of the identification plate. The cable ties are bundled at 2 cm (0.79 in.) from the connectors, and other positions are allowed in special circumstances. Cable ties should be bound on both ends of a cable. After the bundling, the finished identification plate should be on top of the cable in horizontal cabling, or on the right side of the cable in vertical cabling, as shown in Figure 5-87. The details are as follows: The identification card is to the right of the cable in vertical cabling. The identification card is on the top of the cable in horizontal cabling. Make sure that the label is facing out. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 112 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-87 Binding the label for the power cable Cable TO: B03 TO: B03 -48V2 -48V2 Cable The identification card is on the top of the cable in horizontal cabling. The identification card is to the right of the cable in vertical cabling. Contents of Engineering Labels Contents of Labels for Power Cables Labels for power cables are only affixed on one side of the identification plates. On the labels, there is information (the part after the mark "TO:") about the location of the device on the other end of the cable, like the location of control cabinet, distribution box or power socket. Contents of Labels for Signal Cables The two sides of the label affixed on the signal cable carry information about the location of the ports connected to both ends of the cable. Figure 5-88 shows the information on both sides of the labels affixed to the signal cables. Area 1 contains the location information of the local end of the cable. Area 2 (with the mark "TO:") contains the location information of the opposite end of the cable. Area 3 has been folded up inside the label. Figure 5-88 Printed parts on the label for signal cables Seen from the cabling end of the equipment, the text part of the label is on the right side of the cable. The side with "TO:" that is facing outside carries the location information of the opposite end; and the other side carries the location information of the local end. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 113 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Therefore, the information in Area 1 at one end is the same as the information in Area 2 at the other end of the cable. In other words, the local information at one end is called the opposite information at the other end. Precautions for Using Engineering Labels When using labels, pay attention to the following points: When printing, writing, or attaching labels, keep the labels clean. Since the label paper is made of moistureproof and waterproof material, ink-jet printers and ink pens are forbidden for printing and writing labels. Labels should be attached tidily. New-type labels are L-shaped. If they are pasted at incorrect locations or in wrong directions, the appearance of the device is affected. Power cable ties should be attached in the same positions on power cables, with identification plates on the same side. The positions of "up", "down", "left" or "right" are all based on the viewpoint of the engineering person who works on the label. 5.4.2 Engineering Labels for Optical Fibers These labels are affixed to the optical fibers that connect the optical interfaces on the boards in a chassis, or on the device boxes. There are two types of labels for optical cables: One is for the fiber that connects the optical interfaces on two devices. The other is for the fiber that connects the device and the ODF. Labels for the Optical Fibers Connecting Devices Meaning of the Label Table 5-22 lists information on both sides of the labels affixed to the optical fibers that connect two devices. Table 5-22 Information on labels affixed to the fiber between two devices Content Meaning Example MN-B-C-DR/T MN: cabinet number M: The cabinet rows from front to back are numbered from A to Z. N: The cabinet columns from left to right are numbered from 01 to 99. For example, A01 is the cabinet in Row A and Column 01. Issue 03 (2015-05-18) B: chassis number Numbered in bottom-up order with two digits, for example, 01. C: physical slot number Numbered in the top-down and left-right order starting from 01. For example, 01 is the slot with number 1. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 114 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide Content 5 Appendix Meaning Example D: optical interface number. Numbered in a top-bottom and left-right order, consistent with the port sequence number on the device. R: Receiving interface T: optical transmitting interface Example of the Label Figure 5-89 shows the label on the cable. Figure 5-89 Example of the label on the optical fiber between two devices 05 01 01 01 TO: G01 01 01 A01 The meaning of the labels is listed in Figure 5-89. "A01-01-05-01-R" indicates that the local end of the optical fiber is connected with the optical receiving interface 01 on slot 5, chassis 01 in the cabinet on row A, column 01 in the machine room. "G01-01-01-01-T" indicates that the opposite end of the optical fiber is connected with Optical Transmitting Interface 01 on Slot 01, Chassis 01 in the cabinet on Row G, Column 01 in the machine room. Labels for the Optical Fibers Connecting the Device and an ODF Meaning of the Labels Table 5-23 shows the information on both sides of the labels attached to the optical fiber that connects the device and the ODF. Table 5-23 Information on labels affixed to the fiber between the device and the ODF Issue 03 (2015-05-18) Content Meaning Example MN-B-C-DR/T MN: cabinet number For example, A01. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 115 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide Content 5 Appendix Meaning Example B: chassis number Numbered in bottom-up order with two digits, for example, 01. C: physical slot number Numbered in the top-down and left-right order starting from 01. For example, 01 is the slot with number 1. D: optical interface number. Numbered in a top-down and left-right order, consistent with the port sequence number on the device. R: Optical receiving interface T: optical transmitting interface ODF-MN-BC-R/T MN: row number and column number of an ODF M: The cabinet rows from front to back are numbered from A to Z. N: The cabinet columns from left to right are numbered from 01 to 99. For example, G01 is the ODF of Row G and Column 01. B: row number of the terminal device Range from 01 to 99, for example, 01-01. C: column number of the terminal device R: Optical receiving interface T: optical transmitting interface Example of the Label Figure 5-90 shows the label on the cable. Figure 5-90 Example of the label on the optical fiber between the device and the ODF 01 01 05 01 Issue 03 (2015-05-18) 01 TO: A01 ODF G01 Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 116 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Meaning of the label in Figure 5-90 "ODF-G01-01-01-R" indicates that the local end of the optical fiber is connected to the optical receiving terminal on row 01, column 01 of the ODF in row G, column 01 in the machine room. "A01-01-05-01-R" indicates that the opposite end of the optical fiber is connected to Optical Receiving Interface 1 on Slot 05, chassis 01 in the cabinet on Row A, Column 01 in the machine room. 5.4.3 Engineering Labels for Network Cables Applicable Ranges The labels can be applied to Ethernet cables. Label Content Table 5-24 shows the information on both sides of the labels affixed to Ethernet cables. You can also decide the label content according to the actual environment. If the device is not installed in the cabinet, for example, you can remove the cabinet number. Table 5-24 Information on the Ethernet cables Content Meaning Example MN-B-C-D MN: cabinet number For example, A01 is the first cabinet in row A. B: chassis number Numbered in the bottom-up order with two digits, for example, 01. C: physical slot number Numbered with two digits in top-down and left-right order. For example, 01. D: network port number Numbered in the top-down and left-right orders. For example, 01. MN: cabinet number For example, B02 is the second cabinet in Row B. Z: Location number Fill in the location number of the terminal device on site. If the cable is connected to a device in a cabinet, the serial numbers of the cabinet, the chassis, and the Ethernet interface of the device should be specified. For example, B02-03-12. If the cable is connected to the Network Management Station (NMS), the specific location of the NMS should be given. MN-Z Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 117 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix The contents of the labels for network cables connecting hubs and devices or agents and the network cables for other purposes should be specified according to actual connections. The details are as follows: For a network cable connecting a hub and device, the label on the hub end should indicate the numbers of the chassis and cabinet where the hub resides, and the serial number on the hub. The label on the device end should indicate the number of the chassis and cabinet where the device is located. If the device is a stand-alone device, the specific position of the device should be provided. For a network cable connecting a hub and an agent or terminal, the label on the agent or terminal end should contain the serial number of the network interface. The definitions of the cabinet number and chassis number are the same as those described in Table 5-24. If the hub is a stand-alone device without cabinet or chassis, the label should contain specific location information that identifies the hub. The serial number on the hub, the network interface number of the agent or terminal, and the location of the stand-alone device should be specified according to actual connections. Label Example Figure 5-91 shows the label on the cable. Figure 5-91 Example of the label on network cables 01 01 03 03 TO: B02 A01 01 Meaning of the label in Figure 5-91. "A01-03-01-01" indicates that one end of the network cable is connected to network interface 01 of slot 01, chassis 03 of the cabinet on row A, column 01 in the equipment room. "B02-03-01" indicates that another end of the network cable is connected to network interface 01, chassis 03 of the cabinet on row B, column 02 in the equipment room. No slot number is given. 5.4.4 Engineering Labels for User Cables Attach labels to both ends of the cable to indicate the locations of the cable on the device and MDF. Meaning of the Engineering Labels for User Cables Table 5-25 shows the contents of the labels. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 118 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Table 5-25 Contents of the engineering labels for user cables Content Meaning Example MN-B-C-D MN: cabinet number For example, A01 is the first cabinet in row A. B: frame number Numbered in the bottom-up order with two digits, for example, 03. C: physical slot number Numbered with two digits in the top-down and leftright order. For example, 01. D: cable number Numbered with two digits in the top-down and leftright order. For example, 01. MN: row number and column number of the MDF M: The rows of cabinets from front to back are numbered from A to Z. N: The columns of cabinets from left to right are numbered from 01 to 99. For example, G01 is the MDF of row G and column 01. B: row number of the terminal device Ranges from 01 to 99, for example, 01-01. MDF-MN-B-C C: column number of the terminal device Example of the Label Figure 5-92 shows an example. Figure 5-92 Example of labels for user cables 03 01 01 TO: MDF G01 01 A01 01 The meaning of the label in Figure 5-92 is as follows: "A01-03-01-01" indicates that the local end of the user cable is connected to port 1 of on slot 1, chassis 03 of the cabinet on row A, column 01 in the equipment room. "MDF-G01-01-01" indicates that the opposite end of the user cable is connected to the terminal on row 01, column 01 of the MDF in row G, column 01 in the equipment room. 5.4.5 Engineering Labels for Power Cables Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 119 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Engineering Labels for DC Power Cables The labels are affixed to the DC power cables that provide power supply for cabinets, including the -48 V, PGND, and BGND cables. Here, the DC power cables also include power cables and PGND cables. The labels for DC power cables are affixed to one side of the identification plates on cable ties. For details of the labels, see Table 5-26. Table 5-26 Contents of the label Content Meaning MN(BC)B--48Vn MN(BC): BC is written right under MN. MN(BC)-BBGND MN(BC)-BPGND B: chassis number, numbered in the bottom-up order with two digits, for example, 01. N: power socket number, numbered as 1 to 3 in the bottom-up and leftto-right orders. On the loaded cabinet side, only MN is used to identify the cabinet. On the power cabinet side, MN identifies the row and column number of the power distribution equipment like a control cabinet and distribution box, and BC identifies the row and column number of the -48 V connector. If there is no row number or column number, or the connector can be identified without them, BC can be omitted. It is unnecessary for BGND and PGND to identify the row and column number. The label only carries location information about the destination direction of the power cable while information of the local end is not necessary. That is, the label only carries location information about the opposite equipment, the control cabinet, or the distribution box. Table 5-26 lists the information on two -48 V power supplies on the label. The information on other DC voltages, such as 24 V and 60 V should be given in similar methods. Make sure that labels are affixed in the correction direction. That is, after the cable ties are bundled onto the cable, the identification plates with the labels should face up, and the text on the labels in the same cabinet should be in the same direction. For details, see Figure 5-93. Figure 5-93 Example of the labels for DC power cables Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 120 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix The meaning of the label in Figure 5-93 is as follows: On the loaded cabinet side, the label "A01/B08--48V2" on the cable indicates that the cable is -48 V DC supply, which is from the eighth connector on row B of -48 V bus bar in the cabinet on row A, and column 1 in the equipment room. On the distribution box side, the label "B03--48V2" indicates that the cable is -48 V DC supply, connected to DC power socket 2 on row B, column 03 in the equipment room. NOTE In the power distribution box or the first power cabinet of a row in a transmission equipment room, every terminal block on the -48 V connector bar has a numeric identification. For example, in the above label of "A01/B08--48V2", "08" (or sometimes "8") is the numeric identification of the terminal block. PGND and BGND are two copper bars, on which the terminal blocks are short-circuited, therefore which terminal is connected makes no difference. It is only necessary to give the row and column of the power distribution box, instead of giving the specific serial number of the terminal block on the copper bar. For example, if the label on the loaded cabinet side is "A01BGND", it means that the power cable is a BGND that connects BGND copper bar in the power distribution box on Row A, Column 01 in the machine room. Information on the labels for PGND cables should be given in a similar way. Engineering Labels for AC Power Cables The labels are affixed to both ends of an AC power cable that provides AC power supply to cabinets, including 110/220 V, PGND, and BGND cables. The 110/220 V AC cables and related PGND and BGND cables are covered with an insulating sheath, so the labels need to contain only the word "AC" and the cabinet numbers. The labels for AC power cables are affixed to one side of the identification plates on cable ties. For details, see Table 5-27. Table 5-27 Label content Content Meaning MN-(B)-ACn MN: serial number of the cabinet or the socket where the power is led in B: chassis number, numbered in the bottom-up order with two digits, for example, 01. n: power port number, numbered as 1 to 3 in bottom-up and left-to-right order. Serial number of the socket where the power is led in: the location of the socket is marked according to the actual situation. If the sockets can be identified by row numbers and column numbers, they can be numbered following the same rule for the cabinets. If the sockets cannot be identified by rows and columns, specify the detailed locations to avoid confusion with other sockets. The label only carries location information about the opposite equipment and the power socket; information about the local end is not necessary. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 121 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Make sure that labels are affixed in correct direction. That is, after the cable ties are bundled onto the cable, the identification plates with the labels should face up, and the text on the labels in the same cabinet should be in the same direction, as shown in Figure 5-94. Figure 5-94 Labels for AC power cables Label on the loaded cabinet side (indicating the position of the cable on the power distribution box) Label on the distribution box side (indicating the position of the cable on the loaded cabinet side) Meaning of the label in Figure 5-94. On the equipment cabinet side, the label marked with "A01-AC1" indicates that the power cable is connected to the first AC power socket of Row A and Column 01 in the equipment room. On the power socket side, the label marked with "B01-AC1" indicates that the power cable is connected to the first AC power socket in the cabinet of Row B and Column 01 in the equipment room. 5.5 Guide to Using Optical Modules Common Faults of an Optical Module 1. An optical module is not completely installed in position. If the optical module is not completely installed in position and the latch boss is not secured, the device cannot identify the optical module. After the optical module works for a long time, it will be ejected under external stress. 2. The optical receptacle on an optical module is contaminated. If an optical module is not cleaned or protected properly, contaminants may accumulate on the fiber pin in the optical module. As a result, the coupling efficiency is reduced, optical signals are cut off, or even worse, the surface of the fiber pin is damaged permanently. 3. An optical module is burnt. If large-power optical signals (caused by the OTDR or self-loop test) are transmitted through an optical module that is used for long-distance transmission but no optical attenuator is used, the optical power will exceed the overload power of the APD pipe. Then the optical module is burnt. The preceding faults lead to temporary or long-term cut-off of optical signals; or even cause permanent damages to the optical module, affecting communication services. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 122 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Measures to Prevent Loosened Optical Module 1. When installing an optical module, insert it into position. If you hear a click or feel a slight shake, it indicates that the latch boss is secured. If the latch boss is not secured, the gold finger of the optical module is not in good contact with the connector on the board. In this case, the link may be connected but optical signals will be cut off or the optical module will be loosened when the optical module is shook or crashed. 2. Figure 5-95 shows the release handle on an optical module when it is open and closed. When inserting the optical module, make sure that the release handle is closed. At this time, the latch boss locks the optical module. After the optical module is inserted, try pulling it out to see if it is installed in position. If the optical module cannot be pulled out, it is secured. Figure 5-95 State of the release handle Close the release handle Open the release handle Measures to Prevent Receptacle Contamination 1. Cleaning tissues must be prepared on site. You need to clean the optical connector before inserting it in the receptacle. This protects the receptacle against the contamination on the surface of the optical connector. Figure 5-96 Cleaning optical fibers with special cleaning tissues NOTE Place at least three cleaning tissues on the work bench. As shown in Figure 5-96, wipe the end of an optical connector from left to right or from right to left on a cleaning tissue, and then move the connector end to the unused part of the cleaning tissue to continue. 2. Issue 03 (2015-05-18) Cover an unused optical module with a protective cap to prevent dust, as shown in Figure 5-97. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 123 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-97 Installing a protective cap If no protective cap is available, use fibers to protect the optical module, as shown in Figure 5-98. Figure 5-98 Using fibers to protect an optical module 3. Cover unused optical connectors with protective caps, as shown in Figure 5-99, and then lay out fibers on the fiber rack or coil them in a fiber management tray to prevent fibers from being squeezed. Figure 5-99 Installing a protective cap on a fiber 4. Issue 03 (2015-05-18) If a receptacle or an optical connector has not been used for a long time and is not covered with a protective cap, you need to clean it before using it. Clean a receptacle with a cotton swab, as shown in Figure 5-100. Clean an optical connector with cleaning tissues. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 124 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide 5 Appendix Figure 5-100 Cleaning a receptacle with a cotton swab NOTICE When cleaning a receptacle, insert the cotton swab and turn it slowly in the receptacle. Do not use too much strength because the receptacle may be damaged. 5. If optical signals are lost during the operation of a device, use the preceding method to clean the receptacle or the optical connector. In this manner, the possibility of contamination can be excluded. Measures to Prevent an Optical Module from Being Burnt 1. Before using an optical time-domain reflectometer (OTDR) to test the connectivity or the attenuation of optical signals, disconnect the optical fibers from the optical module. Otherwise, the optical module will be burnt. 2. When performing a self-loop test, use an optical attenuator. Do not loosen the optical connector instead of the optical attenuator. 1. The optical connector should be vertically inserted in the receptacle to avoid damages to the receptacle. 2. Fibers must be inserted into optical modules of the corresponding type. That is, multimode fibers must be inserted into multimode optical modules, and single mode fibers must be inserted into single mode optical modules. If a fiber is inserted into an optical module of a different mode, faults may occur. For example, optical signals will be lost. Precautions 5.6 Fault Tag *Customer name: Address: Contact person: Tel.: Fax: Category*: □ RMA □ Return □ Analysis Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 125 Huawei AP8030DN & AP8130DN Hardware Installation and Maintenance Guide BOM Code Product Description 5 Appendix Bar Code* Fault Occurring Date* Description of the Fault Phenomena* Category No.* Software Version* Reasons for Repairing (Category No.): Category No. includes the following eight types: F001 - Wear out damaged (◊ In warranty Period ◊ Out of warranty period) F002 - Deployment damaged F003 - Intransit damaged F004 - Version upgrade F005 - Batch replace F007 - Overdue spare parts inspecting F008 - Others F011 - Running circumstance change Note: l For optical interface cards returned, the optical interfaces should be covered with protection caps. l In general, the analysis card will not be returned to you. If you have any special requirements, please contact Huawei. l One Fault Tag should be adapted in one return category, such as RMA/Return/Analysis. l The items marked with "*" are the mandatory fields that you must fill in. Issue 03 (2015-05-18) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 126
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Author : Huawei Technologies Co., Ltd. Create Date : 2015:05:21 01:28:07+08:00 Modify Date : 2015:05:21 01:28:07+08:00 Creator : AH Formatter V6.0 R1 (6,0,2012,1211) for Windows Producer : Antenna House PDF Output Library 2.4.0 (Windows) Title : Hardware Installation and Maintenance Guide Subject : Hardware Installation and Maintenance Guide Trapped : False Page Count : 132 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools