BTS3701B V300R003
Installation Guide
Issue: 01
Date: 2010-03-20
HUAWEI TECHNOLOGIES CO., LTD.
Safety Precautions
■
Abide by All Safety Requirements
To ensure personal and equipment safety, abide by safety precautions described in the label on equipment or
in the manual when you install, operate, or maintain the equipment. The "Safety Warning", "Caution", and
"Note" in the manual are not the contents of safety requirements. They are provided as the supplement to the
safety precautions.
When operating Huawei products or equipment, strictly follow all precautions and special safety instructions
required by Huawei. The "Safety Warning" in the manual is only based on the knowledge of Huawei. Huawei
will not assume any responsibility for the loss incurred by operations violating the universal safety rules or
standards for designing, producing, or using the equipment.
■
Abide by Local Laws and Regulations
When operating the equipment, abide by local laws and regulations.
■
Requirements for Personnel
The installation and maintenance personnel of Huawei equipment must be strictly trained. They are not allowed
to install, operate, or maintain the equipment until they have mastered the correct operation method and got
familiar with the safety requirements.
■
Symbol Description
Indicates a hazard with a high level of risk, which if not avoided, will result in death or
serious injury.
Indicates a hazard with a medium or low level of risk, which if not avoided, could result
in minor or moderate injury.
Indicates a potentially hazardous situation, which if not avoided, could result in
equipment damage, data loss, performance degradation,
or unexpected results.
Indicates a tip that may help you solve a problem or save time.
Provides additional information to emphasize or supplement important points of the
main text.
■
Personal Safety
• Directly contacting or indirectly contacting high voltage power supply through wet objects is lethally dangerous.
• Incorrect high voltage operations will cause incidents such as fire or a shock hazard.
• Never perform any high voltage AC operations or perform operations on a tower or a mast during a
thunderstorm. It can be lethally dangerous.
• Any equipment must be grounded before it is connected to the power supply. Ungrounded equipment can be
lethally dangerous.
• Never perform any hot-line operation.
• Strong RF signals are harmful to human health. Ensure that the transmit antennas are shut down before an
antenna installation or maintenance operation on a tower or mast installed with multiple transmit antennas.
• During an operation involving optical cables, keep your eyes far away from optical output ports and do not
directly look at the optical output ports with bare eyes.
• Take measures to prevent dusts from entering your respiratory tract or eyes when drilling holes.
• Before connecting cables to storage batteries, disconnect the storage batteries from the power supply.
Otherwise, injuries may be incurred.
• When working aloft, take measures to prevent objects from falling.
■
Equipment Safety
• Before operating the equipment, check the electric continuity of the equipment that requires grounding to
ensure that it is reliably grounded.
• The static electricity produced by human body may damage the static-sensitive components, such as LSI on
boards. Take proper ESD prevention measures, for example, wear ESD wrist straps or gloves to prevent
boards, modules, and electronic components from being destroyed by static of the human body.
• When operating storage batteries, prevent the battery short-circuiting and electrolyte overflow or leakage. The
electrolyte corrodes metal objects and the boards, producing rust and causing board short-circuiting.
Copyright © Huawei Technologies Co., Ltd. 2010.
© All rights reserved.
Installation Process
Tools
Measuring tape
Vacuum cleaner
Diagonal pliers
Marker
Hammer drill
Adjustable wrench
Phillips screwdriver
Level
Ladder
Rubber mallet
Wire stripper
z When an external antenna is used,
connect the antenna to the BTS3701B
before installing the BTS3701B.
z When the BTS3701B is installed on a
wall, the integrated mode is
recommended.
z The BTS3701B must be installed at least
0.5 m (1'-7 11/16'') away from the
interference sources such as power
supply and at least 2 m (6'-6 3/4'') away
from the high frequency radiation
sources.
The BTS3701B cannot be placed horizontally
on a flat object, such as a table.
Space Requirements
a Dimensions of the BTS3701B
65 mm
(2 9/16'')
230 mm
(9 1/16'')
165 mm
(6 1/2'')
b Minimum Space Requirements
≥ 300 mm
(11 13/16'')
≥ 250 mm
(9 13/16'')
≥ 100 mm
(3 15/16'')
≥ 250 mm
(9 13/16'')
≥ 170 mm (6 11/16'')
A minimum of 500 mm (1'-7 11/16'') should
be reserved at the back of the BTS3701B
only in the ceiling installation mode.
Installation Modes
Adapter
BTS3701B
Transitional
piece
Mounting bracket
for the module
Ceiling mounting
bracket
Mounting bracket
for the adapter
a Installing the BTS3701B on a Wall (Separated Mode)
Regular installation
Reverse installation
b Installing the BTS3701B on a Wall (Integrated Mode)
Regular installation
Reverse installation
Installation Modes
20 mm (13/16'') to
65 mm (2 9/16'')
The requirements for the installation carrier are as follows:
20 mm
(13/16'') to 75
mm (2 15/16'')
20 mm (13/16'') to
85 mm (3 3/8'')
Pole
20 mm (13/16'') to
75 mm (2 15/16'')
Angle steel
20 mm (13/16'') to
65 mm (2 9/16'')
U-steel
c Installing the BTS3701B on a Pole (Separated Mode)
Regular installation
Reverse installation
d Installing the BTS3701B on a Pole (Integrated Mode)
Regular installation
Reverse installation
Installation Modes
e Installing the BTS3701B on a Ceiling
Regular installation
Reverse installation
If the BTS3701B is installed on a ceiling, the ceiling must be made of
concrete and can bear a weight of 323.6 N.m (2864.10 lbf.in.).
Installing the BTS3701B on a Wall
Determining Installation Positions of the
Mounting Brackets
88 mm (3 7/16'')
≥ 200 mm (7 7/8'')
Drilling Holes and Installing Expansion Bolts
88 mm
(3 7/16'')
24 mm (15/16'')
to 25 mm (1'')
For the integrated installation mode, determine
only the installation position of the adapter.
Installing the BTS3701B on a Wall
c Separated Mode
M4
M3.5×20
3 ± 0.5 N.m
(26.55 ± 4.43 lbf.in.)
Installation procedure
The procedures of regular installation and reverse
installation are identical.
Installing the BTS3701B on a Wall
d Integrated Mode
M4
3 ± 0.5 N.m
(26.55 ± 4.43 lbf.in.)
10 N.m
(88.51 lbf.in.)
The procedures of regular installation and
reverse installation are identical.
Installing the BTS3701B on a Pole
a Separated Mode
3 ± 0.5 N.m
(26.55 ± 4.43 lbf.in.)
≥ 300 mm
(11 13/16'')
M4
b Integrated Mode
M4
3 ± 0.5 N.m
(26.55 ± 4.43 lbf.in.)
10 N.m
(88.51 lbf.in.)
The procedures of regular installation
and reverse installation are identical.
Installing the BTS3701B on a Ceiling
Determining Installation Positions of
Bolts
Drilling Holes and Installing
Expansion Bolts
24 mm
(15/16'') to
25 mm (1'')
Marking
template
Installing the BTS3701B on a Ceiling
M3.5×20
Installation procedure
10 N.m
(88.51 lbf.in.)
The procedures of regular
installation and reverse installation
are identical.
10
Connecting Cables
4-pin
connector of
the DC input
power cable
Cable
Connector
Connected to...
Straightthrough
cable
RJ45 connector
FE/GE port on the
BTS3701B
RJ45 connector
Operator's transmission
equipment
Power
cable
PA male connector
AC power wiring bar
C7 female connector
Power adapter
DC input
power
cable
4-pin connector
PWR port on the
BTS3701B
The other end is connected to the power adapter.
If the delivered Ethernet cable [3 m (9'-10 1/8'')]
does not meet the requirement, prepare one
on site based on actual requirements.
Powering On the BTS3701B
Connect the PA male connector to
the AC power wiring bar to power on
the BTS3701B.
Indicator
Color
Status
Description
Power
Green
On
The power supply is normal.
Off
There is no power supply, or the
BTS3701B is faulty.
Blinking at 0.5 Hz (green) (on for 1s, off for 1s)
The BTS3701B is running normally.
Blinking at 4 Hz (green) (on for 0.125s, off for
0.125s)
The BTS3701B is being loaded, or
the BTS3701B is not started.
On (red)
An alarm is generated, and the
BTS3701B needs to be replaced.
Blinking at 0.5 Hz (red) (on for 1s, off for 1s)
An alarm is generated. Rectify the
fault based on the reported alarm.
On
The FE port is securely connected.
Blinking at 4 Hz (green) (on for 0.125s, off for
0.125s)
Data is being transmitted and
received over the FE port.
Off
The FE port is insecurely connected.
RUN/ALM
LINK
Red and
green
Green
11
Appendix: Cabling Routes for Different Installation Modes
a Installing the BTS3701B on a Wall
Separated Mode
Integrated Mode
b Installing the BTS3701B on a Pole
Separated Mode
Installing the BTS3701B
on a Ceiling
Integrated Mode
Straight-through cable
DC input power cable
Power cable
z When the BTS3701B is installed on a pole, fix the input power
cable of the power adapter on the pole using a tie wrap.
z Before powering on the equipment, ensure that the antenna of the
BTS3701B is vertical.
12
e Installing the External Equipment
FE/GE
POWER
Powered device (PD)
IN
OUT
Network
equipment
OUT
The distance between the PSE and the PD
should be more than 1 m (3'-3 3/8''). The
PSE cannot be installed on a ceiling.
IN
Power sourcing equipment (PSE)
Appendix: Removing the Equipment
Spring
pad
Press the spring pad and rotate the
BTS3701B clockwise to remove it.
13
Huawei Technologies Co., Ltd.
Administration Building, Huawei Technologies
Co., Ltd., Bantian, Longgang District, Shenzhen,
P. R
Zip code: 518129
www.huawei.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 15
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:6a170b15-672b-42ec-8550-e91e08e9a881
Producer                        : Acrobat Distiller 6.0 (Windows)
Create Date                     : 2010:05:14 11:40:43+08:00
Modify Date                     : 2010:05:14 11:40:43+08:00
Document ID                     : uuid:4af82e4e-6253-42c1-9552-8552b284b6c0
Format                          : application/pdf
Title                           : untitled
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QISBTS3701B-2500M

Navigation menu