User Manual iSiteC ODU3601C CDMA Soft Base Station BTS MaintenanceChapter 1  Routine Maintenance Instructions 1-1 Chapter 1  Routine Maintenance Instructions 1.1  Overview ODU3601C Routine Maintenance Instructions describes in details the contents and methods of ODU3601C routine maintenance operations. It serves as a reference in determining the routine maintenance schedule of a particular site. 1.1.1  Purposes of Routine Maintenance Normal system operation of ODU3601C in different running environment depends on effective routine maintenance. ODU3601C routine maintenance is intended to detect and solve problems in due time to prevent trouble. 1.1.2  Classification of Routine Maintenance Operations I. Classification by implementing methods l Conventional maintenance This method is applied on regular basis to observe the operation of the system, test and analyze equipment performance. l Unconventional maintenance The unconventional method is to test whether the system performance has degraded by artificially creating some faults. For example, maintenance engineers may artificially create some faults and test if the alarm system reports alarm correctly. II. Classification by period length l Unscheduled maintenance This includes the maintenance operations  performed at equipment fault or network adjustment. For example, maintenance tasks  performed due to by user complaint, damage of equipment and line fault. Solving of problems left over by daily maintenance operations is also regarded as unscheduled maintenance operation. l Daily maintenance It refers to the maintenance tasks conducted each day. ODU3601C daily maintenance helps  maintenance engineers keep track of the operating conditions of the equipment at any moment so that problems can be solved in time. When a problem is detected in daily maintenance, record it in detail to help eliminate it in time. 
User Manual iSiteC ODU3601C CDMA Soft Base Station BTS MaintenanceChapter 1  Routine Maintenance Instructions 1-2 l Periodical maintenance Periodical  maintenance refers to the maintenance tasks conducted regularly. Periodical maintenance helps maintenance engineers keep track of the long-term performance of the equipment. Periodical maintenance includes: monthly maintenance, quarterly maintenance and yearly maintenance. 1.1.3  Usage of Routine Maintenance Records As a maintenance engineer, you are required to fill in the following tables when you conduct the daily, monthly, quarterly and yearly maintenance for your ODU3601C. And specific instructions have been given after those tables. I. Daily unexpected fault handling record Note down in details the unexpected faults occurred in ODU3601C daily maintenance operations in the table for future reference. The user may modify the record according to the actual needs, or compile the records into manuals. II. Monthly maintenance record Note down in details the actual maintenance operations carried out during ODU3601C monthly maintenance in the table. For details, see ODU3601C Monthly Maintenance Operation Instruction. III. Quarterly maintenance record Note down in details the actual maintenance operations carried out during ODU3601C quarterly maintenance in the table. For details, see ODU3601C Quarterly Maintenance Operation Instruction. IV. Yearly maintenance record Note down in details the actual maintenance operations carried out during ODU3601C yearly maintenance in the table. For details, see ODU3601C Yearly Maintenance Operation Instruction. 
User Manual iSiteC ODU3601C CDMA Soft Base Station BTS MaintenanceChapter 1  Routine Maintenance Instructions 1-3 Table 1-1 Daily Unexpected Fault Handling Record Site    Belong-to BSC  Time when fault occurred:  Time when fault is solved:  Person on duty:  Handled by:  Classification of fault:    Micro-bts Ac-dc Power supply Module (MAPM)      Micro-bts Radio Frequency Front End Module (MFEM)    Antenna and feeder system    Micro-bts Transceiver Module (MTRM)    Micro-bts Power Amplifier Module (MPAM)    Others Fault detected:    With user complaint                               From the alarm system    In Daily maintenance                              From other sources Description of fault:                       Alarm handling & result: 
User Manual iSiteC ODU3601C CDMA Soft Base Station BTS MaintenanceChapter 1  Routine Maintenance Instructions 1-4 Table 1-2 Monthly Maintenance Record Site: _______________ Time of maintenance:____(MM)_____(DD)_____(YY)    ____(MM)____(DD)____(YY) Maintainer: Items Status Remarks Maintenance engineers Environment •Normal, •Abnormal     Temperature •Normal, •Abnormal     Humidity •Normal, •Abnormal     Indoor air-conditioner •Normal, •Abnormal Upon indoor installation for ODU3601C  Call test •Normal, •Abnormal     Battery group •Normal, •Abnormal When a battery group is used  Grounding, lightening protection and power supply system •Normal, •Abnormal     RF antenna and feeder part •Normal, •Abnormal     Power supply module •Normal, •Abnormal     Description of fault and handling measures taken          Problems remained         Shift leader check              Caution: Avoid short circuit upon battery check!
User Manual iSiteC ODU3601C CDMA Soft Base Station BTS MaintenanceChapter 1  Routine Maintenance Instructions 1-5 Table 1-3 Quarterly Maintenance Record Site: _______________ Time of maintenance:____(MM)_____(DD)____(YY)             ____(MM)____(DD)____(YY) Maintainer: Items Status Remarks Maintenance engineers Power supply •Normal, •Abnormal     Road test •Normal, •Abnormal     Accessories check •Normal, •Abnormal       Description of fault and handling measures taken              Problems remained                   Shift leader check
User Manual iSiteC ODU3601C CDMA Soft Base Station BTS MaintenanceChapter 1  Routine Maintenance Instructions 1-6 Table 1-4 Yearly Maintenance Record Site: _______________ Time of maintenance:____(MM)_____(DD)_____(YY)             ____(MM)____(DD)____(YY) Maintainer: Items Status Remarks Maintenance engineers Call test •Normal, •Abnormal    Cabinet sanitation •Normal, •Abnormal    BTS power output •Normal, •Abnormal    Grounding resistance and grounding wires •Normal, •Abnormal    Water-proof performance of antenna and feeder connector and lightening protection grounding clip •Normal, •Abnormal    Firmness and angle of antenna •Normal, •Abnormal    Description of fault and handling measures taken          Problems remained             Shift leader check
User Manual iSiteC ODU3601C CDMA Soft Base Station BTS MaintenanceChapter 1  Routine Maintenance Instructions 1-7 1.2  Monthly Maintenance Instructions Items Instructions Note Call test Make calls with a Mobile Station (MS). Collect information at both the MS and the Base Station Controller (BSC) to see if all calls are normal for all sector carriers. There should be no noise, no call dropping, nor cross talking. Grounding, lightening protection systems and power supply system 1) Check the connections in the grounding system and the lightening protection system.   2) Check if the power supply system is normal.   3) Check if any part of the lightening protector is burnt. Keep the lightening protector in good status. Antenna and feeder part 1) Check if the support of the antenna is set to the correct direction;   2) Check if the water-proof performance of the feeder is normal. Query at the maintenance console.   Power supply module Check if there is any alarm on the power supply module.   1.3  Quarterly Maintenance Instructions Items Instructions Note Check 220V AC supply Measure whether input voltage and frequency are in the specified range. Range of normal input voltage: Rated frequency: Road test Test on the handoff and coverage area of the cells with a test MS.  Accessories check Check the auxiliary facility box and UPS, etc.   1.4  Yearly Maintenance Instructions Items Instructions Note Call test Make calls with an MS. Collect information at both the MS and the BSC to see if all calls are normal for all sector carriers. There should be no noise, no call dropping, nor cross talking. Cabinet sanitation Tools required: Vacuum cleaner, alcohol and towel. Impose strict operation regulations to prevent mis- operation on the power supply system. BTS power output Test the transmit power of the carriers. Check if the output is the same as designed in the BSC. Grounding resistance and grounding wires 1) Measure the grounding resistance with proper test instruments. 2) Check for lose grounding wire connectors and their aging status  Water-proof performance of antenna and feeder connector and lightening protection grounding clip 1) Check the external parts;   2) Unwrap them and check. Wrap up the checked parts with the same material used before the check. Firmness and angle of antenna 1) Tighten the bolts with the wrench. 2) Check if the angle are correctly set.   Do not apply too much torque on the bolts