Huawei Technologies ODU3601C-1900 CDMA Base Station User Manual Instructions

Huawei Technologies Co.,Ltd CDMA Base Station Instructions

Users Manual 3

Download: Huawei Technologies ODU3601C-1900 CDMA Base Station User Manual Instructions
Mirror Download [FCC.gov]Huawei Technologies ODU3601C-1900 CDMA Base Station User Manual Instructions
Document ID469703
Application IDDfn4/DaisiDGH8dfjdFxsA==
Document DescriptionUsers Manual 3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize5.02kB (62711 bits)
Date Submitted2004-09-17 00:00:00
Date Available2004-09-13 00:00:00
Creation Date2004-06-26 11:54:05
Producing SoftwareAcrobat PDFWriter 4.0 for Windows
Document Lastmod0000-00-00 00:00:00
Document TitleInstructions.PDF
Document CreatorMicrosoft Word
Document Author: c15897

User Manual
iSiteC ODU3601C CDMA Soft Base Station
BTS Maintenance
Chapter 1 Routine Maintenance Instructions
Chapter 1 Routine Maintenance Instructions
1.1 Overview
ODU3601C Routine Maintenance Instructions describes in details the contents and
methods of ODU3601C routine maintenance operations. It serves as a reference in
determining the routine maintenance schedule of a particular site.
1.1.1 Purposes of Routine Maintenance
Normal system operation of ODU3601C in different running environment depends on
effective routine maintenance. ODU3601C routine maintenance is intended to detect
and solve problems in due time to prevent trouble.
1.1.2 Classification of Routine Maintenance Operations
I. Classification by implementing methods
Conventional maintenance
This method is applied on regular basis to observe the operation of the system, test
and analyze equipment performance.
Unconventional maintenance
The unconventional method is to test whether the system performance has degraded
by artificially creating some faults. For example, maintenance engineers may
artificially create some faults and test if the alarm system reports alarm correctly.
II. Classification by period length
Unscheduled maintenance
This includes the maintenance operations performed at equipment fault or network
adjustment. For example, maintenance tasks performed due to by user complaint,
damage of equipment and line fault. Solving of problems left over by daily
maintenance operations is also regarded as unscheduled maintenance operation.
Daily maintenance
It refers to the maintenance tasks conducted each day. ODU3601C daily
maintenance helps maintenance engineers keep track of the operating conditions of
the equipment at any moment so that problems can be solved in time. When a
problem is detected in daily maintenance, record it in detail to help eliminate it in time.
1-1
User Manual
iSiteC ODU3601C CDMA Soft Base Station
BTS Maintenance
Chapter 1 Routine Maintenance Instructions
Periodical maintenance
Periodical maintenance refers to the maintenance tasks conducted regularly.
Periodical maintenance helps maintenance engineers keep track of the long-term
performance of the equipment.
Periodical maintenance includes: monthly maintenance, quarterly maintenance and
yearly maintenance.
1.1.3 Usage of Routine Maintenance Records
As a maintenance engineer, you are required to fill in the following tables when you
conduct the daily, monthly, quarterly and yearly maintenance for your ODU3601C.
And specific instructions have been given after those tables.
I. Daily unexpected fault handling record
Note down in details the unexpected faults occurred in ODU3601C daily maintenance
operations in the table for future reference. The user may modify the record according
to the actual needs, or compile the records into manuals.
II. Monthly maintenance record
Note down in details the actual maintenance operations carried out during
ODU3601C monthly maintenance in the table. For details, see ODU3601C Monthly
Maintenance Operation Instruction.
III. Quarterly maintenance record
Note down in details the actual maintenance operations carried out during
ODU3601C quarterly maintenance in the table. For details, see ODU3601C Quarterly
Maintenance Operation Instruction.
IV. Yearly maintenance record
Note down in details the actual maintenance operations carried out during
ODU3601C yearly maintenance in the table. For details, see ODU3601C Yearly
Maintenance Operation Instruction.
1-2
User Manual
iSiteC ODU3601C CDMA Soft Base Station
BTS Maintenance
Chapter 1 Routine Maintenance Instructions
Table 1-1 Daily Unexpected Fault Handling Record
Site
Belong-to BSC
Time when fault is
solved:
Handled by:
Time when fault
occurred:
Person on duty:
Classification of fault:
Micro-bts Ac-dc Power supply Module (MAPM)
Micro-bts Radio Frequency Front End Module (MFEM)
Antenna and feeder system
Fault detected:
With user complaint
In Daily maintenance
Description of fault:
Micro-bts Transceiver Module (MTRM)
Micro-bts Power Amplifier Module (MPAM)
Others
From the alarm system
From other sources
Alarm handling & result:
1-3
User Manual
iSiteC ODU3601C CDMA Soft Base Station
BTS Maintenance
Chapter 1 Routine Maintenance Instructions
Table 1-2 Monthly Maintenance Record
Site: _______________
Time of
maintenance:____(MM)_____(DD)_____(YY)
____(MM)____(DD)____(YY)
Maintainer:
Items
Status
Environment
Temperature
Humidity
•Normal, •Abnormal
•Normal, •Abnormal
•Normal, •Abnormal
Indoor air-conditioner
•Normal, •Abnormal
Call test
•Normal, •Abnormal
Battery group
•Normal, •Abnormal
Grounding, lightening protection and power
supply system
RF antenna and feeder part
Power supply module
•Normal, •Abnormal
•Normal, •Abnormal
•Normal, •Abnormal
Description of fault and
handling measures taken
Problems remained
Shift leader check
Caution:
Avoid short circuit upon battery check!
1-4
Remarks
Upon indoor
installation for
ODU3601C
When a battery
group is used
Maintenance
engineers
User Manual
iSiteC ODU3601C CDMA Soft Base Station
BTS Maintenance
Chapter 1 Routine Maintenance Instructions
Table 1-3 Quarterly Maintenance Record
Site: _______________
Time of
maintenance:____(MM)_____(DD)____(YY)
____(MM)____(DD)____(YY)
Items
Power supply
Road test
Accessories check
Maintainer:
Status
•Normal, •Abnormal
•Normal, •Abnormal
•Normal, •Abnormal
Description of fault and
handling measures taken
Problems remained
Shift leader check
1-5
Remarks
Maintenance engineers
User Manual
iSiteC ODU3601C CDMA Soft Base Station
BTS Maintenance
Chapter 1 Routine Maintenance Instructions
Table 1-4 Yearly Maintenance Record
Site: _______________
Time of maintenance:____(MM)_____(DD)_____(YY)
____(MM)____(DD)____(YY)
Maintainer:
Items
Call test
Cabinet sanitation
BTS power output
Grounding resistance and grounding wires
Water-proof performance of antenna and feeder
connector and lightening protection grounding clip
Firmness and angle of antenna
Status
•Normal, •Abnormal
•Normal, •Abnormal
•Normal, •Abnormal
•Normal, •Abnormal
•Normal, •Abnormal
•Normal, •Abnormal
Description of fault and handling
measures taken
Problems remained
Shift leader check
1-6
Remarks
Maintenance
engineers
User Manual
iSiteC ODU3601C CDMA Soft Base Station
BTS Maintenance
Chapter 1 Routine Maintenance Instructions
1.2 Monthly Maintenance Instructions
Items
Instructions
Call test
Grounding, lightening protection
systems and power supply
system
Antenna and feeder part
Power supply module
Note
Make calls with a Mobile Station (MS). Collect
information at both the MS and the Base Station
Controller (BSC) to see if all calls are normal for
all sector carriers.
1) Check the connections in the grounding system
and the lightening protection system.
2) Check if the power supply system is normal.
3) Check if any part of the lightening protector is
burnt.
1) Check if the support of the antenna is set to the
correct direction;
2) Check if the water-proof performance of the
feeder is normal.
Check if there is any alarm on the power supply
module.
There should be no noise, no call
dropping, nor cross talking.
Keep the lightening protector in good
status.
Query at the maintenance console.
1.3 Quarterly Maintenance Instructions
Items
Instructions
Note
Check 220V AC supply
Measure whether input voltage and frequency are
in the specified range.
Road test
Test on the handoff and coverage area of the cells
with a test MS.
Accessories check
Check the auxiliary facility box and UPS, etc.
Range of normal input voltage:
Rated frequency:
1.4 Yearly Maintenance Instructions
Items
Instructions
Call test
Make calls with an MS. Collect information at both the
MS and the BSC to see if all calls are normal for all
sector carriers.
Cabinet sanitation
Tools required: Vacuum cleaner, alcohol and towel.
BTS power output
Test the transmit power of the carriers.
Grounding resistance and
grounding wires
1) Measure the grounding resistance with proper test
instruments.
2) Check for lose grounding wire connectors and their
aging status
Water-proof performance of
antenna and feeder connector
and lightening protection
grounding clip
Firmness and angle of
antenna
Note
There should be no noise, no call
dropping, nor cross talking.
Impose strict operation regulations
to prevent mis- operation on the
power supply system.
Check if the output is the same as
designed in the BSC.
1) Check the external parts;
2) Unwrap them and check.
Wrap up the checked parts with
the same material used before the
check.
1) Tighten the bolts with the wrench.
2) Check if the angle are correctly set.
Do not apply too much torque on
the bolts
1-7

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 7
Creator                         : Microsoft Word
Create Date                     : 2004:06:26 11:54:05
Title                           : Instructions.PDF
Author                          : c15897
Producer                        : Acrobat PDFWriter 4.0 for Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QISODU3601C-1900

Navigation menu