Huawei Technologies ODU3601C-1900 CDMA Base Station User Manual Instructions
Huawei Technologies Co.,Ltd CDMA Base Station Instructions
Contents
Users Manual 3
User Manual iSiteC ODU3601C CDMA Soft Base Station BTS Maintenance Chapter 1 Routine Maintenance Instructions Chapter 1 Routine Maintenance Instructions 1.1 Overview ODU3601C Routine Maintenance Instructions describes in details the contents and methods of ODU3601C routine maintenance operations. It serves as a reference in determining the routine maintenance schedule of a particular site. 1.1.1 Purposes of Routine Maintenance Normal system operation of ODU3601C in different running environment depends on effective routine maintenance. ODU3601C routine maintenance is intended to detect and solve problems in due time to prevent trouble. 1.1.2 Classification of Routine Maintenance Operations I. Classification by implementing methods Conventional maintenance This method is applied on regular basis to observe the operation of the system, test and analyze equipment performance. Unconventional maintenance The unconventional method is to test whether the system performance has degraded by artificially creating some faults. For example, maintenance engineers may artificially create some faults and test if the alarm system reports alarm correctly. II. Classification by period length Unscheduled maintenance This includes the maintenance operations performed at equipment fault or network adjustment. For example, maintenance tasks performed due to by user complaint, damage of equipment and line fault. Solving of problems left over by daily maintenance operations is also regarded as unscheduled maintenance operation. Daily maintenance It refers to the maintenance tasks conducted each day. ODU3601C daily maintenance helps maintenance engineers keep track of the operating conditions of the equipment at any moment so that problems can be solved in time. When a problem is detected in daily maintenance, record it in detail to help eliminate it in time. 1-1 User Manual iSiteC ODU3601C CDMA Soft Base Station BTS Maintenance Chapter 1 Routine Maintenance Instructions Periodical maintenance Periodical maintenance refers to the maintenance tasks conducted regularly. Periodical maintenance helps maintenance engineers keep track of the long-term performance of the equipment. Periodical maintenance includes: monthly maintenance, quarterly maintenance and yearly maintenance. 1.1.3 Usage of Routine Maintenance Records As a maintenance engineer, you are required to fill in the following tables when you conduct the daily, monthly, quarterly and yearly maintenance for your ODU3601C. And specific instructions have been given after those tables. I. Daily unexpected fault handling record Note down in details the unexpected faults occurred in ODU3601C daily maintenance operations in the table for future reference. The user may modify the record according to the actual needs, or compile the records into manuals. II. Monthly maintenance record Note down in details the actual maintenance operations carried out during ODU3601C monthly maintenance in the table. For details, see ODU3601C Monthly Maintenance Operation Instruction. III. Quarterly maintenance record Note down in details the actual maintenance operations carried out during ODU3601C quarterly maintenance in the table. For details, see ODU3601C Quarterly Maintenance Operation Instruction. IV. Yearly maintenance record Note down in details the actual maintenance operations carried out during ODU3601C yearly maintenance in the table. For details, see ODU3601C Yearly Maintenance Operation Instruction. 1-2 User Manual iSiteC ODU3601C CDMA Soft Base Station BTS Maintenance Chapter 1 Routine Maintenance Instructions Table 1-1 Daily Unexpected Fault Handling Record Site Belong-to BSC Time when fault is solved: Handled by: Time when fault occurred: Person on duty: Classification of fault: Micro-bts Ac-dc Power supply Module (MAPM) Micro-bts Radio Frequency Front End Module (MFEM) Antenna and feeder system Fault detected: With user complaint In Daily maintenance Description of fault: Micro-bts Transceiver Module (MTRM) Micro-bts Power Amplifier Module (MPAM) Others From the alarm system From other sources Alarm handling & result: 1-3 User Manual iSiteC ODU3601C CDMA Soft Base Station BTS Maintenance Chapter 1 Routine Maintenance Instructions Table 1-2 Monthly Maintenance Record Site: _______________ Time of maintenance:____(MM)_____(DD)_____(YY) ____(MM)____(DD)____(YY) Maintainer: Items Status Environment Temperature Humidity •Normal, •Abnormal •Normal, •Abnormal •Normal, •Abnormal Indoor air-conditioner •Normal, •Abnormal Call test •Normal, •Abnormal Battery group •Normal, •Abnormal Grounding, lightening protection and power supply system RF antenna and feeder part Power supply module •Normal, •Abnormal •Normal, •Abnormal •Normal, •Abnormal Description of fault and handling measures taken Problems remained Shift leader check Caution: Avoid short circuit upon battery check! 1-4 Remarks Upon indoor installation for ODU3601C When a battery group is used Maintenance engineers User Manual iSiteC ODU3601C CDMA Soft Base Station BTS Maintenance Chapter 1 Routine Maintenance Instructions Table 1-3 Quarterly Maintenance Record Site: _______________ Time of maintenance:____(MM)_____(DD)____(YY) ____(MM)____(DD)____(YY) Items Power supply Road test Accessories check Maintainer: Status •Normal, •Abnormal •Normal, •Abnormal •Normal, •Abnormal Description of fault and handling measures taken Problems remained Shift leader check 1-5 Remarks Maintenance engineers User Manual iSiteC ODU3601C CDMA Soft Base Station BTS Maintenance Chapter 1 Routine Maintenance Instructions Table 1-4 Yearly Maintenance Record Site: _______________ Time of maintenance:____(MM)_____(DD)_____(YY) ____(MM)____(DD)____(YY) Maintainer: Items Call test Cabinet sanitation BTS power output Grounding resistance and grounding wires Water-proof performance of antenna and feeder connector and lightening protection grounding clip Firmness and angle of antenna Status •Normal, •Abnormal •Normal, •Abnormal •Normal, •Abnormal •Normal, •Abnormal •Normal, •Abnormal •Normal, •Abnormal Description of fault and handling measures taken Problems remained Shift leader check 1-6 Remarks Maintenance engineers User Manual iSiteC ODU3601C CDMA Soft Base Station BTS Maintenance Chapter 1 Routine Maintenance Instructions 1.2 Monthly Maintenance Instructions Items Instructions Call test Grounding, lightening protection systems and power supply system Antenna and feeder part Power supply module Note Make calls with a Mobile Station (MS). Collect information at both the MS and the Base Station Controller (BSC) to see if all calls are normal for all sector carriers. 1) Check the connections in the grounding system and the lightening protection system. 2) Check if the power supply system is normal. 3) Check if any part of the lightening protector is burnt. 1) Check if the support of the antenna is set to the correct direction; 2) Check if the water-proof performance of the feeder is normal. Check if there is any alarm on the power supply module. There should be no noise, no call dropping, nor cross talking. Keep the lightening protector in good status. Query at the maintenance console. 1.3 Quarterly Maintenance Instructions Items Instructions Note Check 220V AC supply Measure whether input voltage and frequency are in the specified range. Road test Test on the handoff and coverage area of the cells with a test MS. Accessories check Check the auxiliary facility box and UPS, etc. Range of normal input voltage: Rated frequency: 1.4 Yearly Maintenance Instructions Items Instructions Call test Make calls with an MS. Collect information at both the MS and the BSC to see if all calls are normal for all sector carriers. Cabinet sanitation Tools required: Vacuum cleaner, alcohol and towel. BTS power output Test the transmit power of the carriers. Grounding resistance and grounding wires 1) Measure the grounding resistance with proper test instruments. 2) Check for lose grounding wire connectors and their aging status Water-proof performance of antenna and feeder connector and lightening protection grounding clip Firmness and angle of antenna Note There should be no noise, no call dropping, nor cross talking. Impose strict operation regulations to prevent mis- operation on the power supply system. Check if the output is the same as designed in the BSC. 1) Check the external parts; 2) Unwrap them and check. Wrap up the checked parts with the same material used before the check. 1) Tighten the bolts with the wrench. 2) Check if the angle are correctly set. Do not apply too much torque on the bolts 1-7
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 7 Creator : Microsoft Word Create Date : 2004:06:26 11:54:05 Title : Instructions.PDF Author : c15897 Producer : Acrobat PDFWriter 4.0 for WindowsEXIF Metadata provided by EXIF.tools