  Copyright © Huawei Technologies Co., Ltd. 2016. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior writtenconsent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respectiveholders. NoticeThe purchased products, services and features are stipulated by the contract made between Huawei and thecustomer. All or part of the products, services and features described in this document may not be within thepurchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,and recommendations in this document are provided "AS IS" without warranties, guarantees orrepresentations of any kind, either express or implied.The information in this document is subject to change without notice. Every effort has been made in thepreparation of this document to ensure accuracy of the contents, but all statements, information, andrecommendations in this document do not constitute a warranty of any kind, express or implied.        Huawei Technologies Co., Ltd.Address: Huawei Industrial BaseBantian, LonggangShenzhen 518129People's Republic of ChinaWebsite: http://www.huawei.comEmail: support@huawei.comIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.i
About This DocumentOverviewThis document describes routine maintenance items for a BBU, DCU3900, RHUB3908,pRRU3901, pRRU3902, pRRU3907 and pRRU3911, such as equipment maintenance, andpower-on and power-off operations. It also explains how to replace the components andmodules.NOTElUnless otherwise specified, BBU in this document refers to BBU3900 and BBU3910. For details of theBBU site maintenance guide, see DBS3900 Site Maintenance Guide.lDCU3900 referred to as DCU in this document. For details about the hardware maintenance guide of theDCU, see DCU3900 Hardware Maintenance Guide.lRHUB3908 referred to as RHUB in this document.lUnless otherwise specified, pRRU in this document refers to pRRU3901, pRRU3902, pRRU3907 andpRRU3911.Product VersionThe following table lists the product version related to this document.Product Name Solution Version Product VersionDBS3900 LampSite lSRAN10.1 and later versionslRAN17.1 and later versionsleRAN8.1 and later versionsleRAN TDD 8.1 and laterversionsV100R010C10 and laterversions Intended AudienceThis document is intended for:lSystem engineersDBS3900 LampSiteSite Maintenance Guide About This DocumentIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.ii
lSite maintenance engineersOrganization1 Changes in DBS3900 LampSite Site Maintenance GuideThis chapter provides information about the changes in different document versions ofDBS3900 LampSite Site Maintenance Guide.2 Device Maintenance ItemsThis chapter describes the device maintenance items.3 Powering On and Powering Off the RHUBAfter the RHUB is powered on, check the indicator status. Power off the RHUB in normal oremergency mode as required.4 Powering On and Powering Off the pRRU3901After the pRRU3901 is powered on, check the power supply voltage and indicator status.Power off the pRRU3901 based on the power supply mode.5 Replacing the DevicesThis chapter describes the procedures and cautions when replacing the devices.ConventionsSymbol ConventionsThe symbols that may be found in this document are defined as follows.Symbol DescriptionIndicates an imminently hazardous situation which, if notavoided, will result in death or serious injury.Indicates a potentially hazardous situation which, if notavoided, could result in death or serious injury.Indicates a potentially hazardous situation which, if notavoided, may result in minor or moderate injury.Indicates a potentially hazardous situation which, if notavoided, could result in equipment damage, data loss,performance deterioration, or unanticipated results.NOTICE is used to address practices not related to personalinjury.DBS3900 LampSiteSite Maintenance Guide About This DocumentIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.iii
Symbol DescriptionCalls attention to important information, best practices andtips.NOTE is used to address information not related topersonal injury, equipment damage, and environmentdeterioration. General ConventionsThe general conventions that may be found in this document are defined as follows.Convention DescriptionTimes New Roman Normal paragraphs are in Times New Roman.Boldface Names of files, directories, folders, and users are inboldface. For example, log in as user root.Italic Book titles are in italics.Courier New Examples of information displayed on the screen are inCourier New. Command ConventionsThe command conventions that may be found in this document are defined as follows.Convention DescriptionBoldface The keywords of a command line are in boldface.Italic Command arguments are in italics.[ ] Items (keywords or arguments) in brackets [ ] are optional.{ x | y | ... } Optional items are grouped in braces and separated byvertical bars. One item is selected.[ x | y | ... ] Optional items are grouped in brackets and separated byvertical bars. One item is selected or no item is selected.{ x | y | ... }*Optional items are grouped in braces and separated byvertical bars. A minimum of one item or a maximum of allitems can be selected.[ x | y | ... ]*Optional items are grouped in brackets and separated byvertical bars. Several items or no item can be selected. GUI ConventionsDBS3900 LampSiteSite Maintenance Guide About This DocumentIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.iv
The GUI conventions that may be found in this document are defined as follows.Convention DescriptionBoldface Buttons, menus, parameters, tabs, window, and dialog titlesare in boldface. For example, click OK.> Multi-level menus are in boldface and separated by the ">"signs. For example, choose File > Create > Folder. Keyboard OperationsThe keyboard operations that may be found in this document are defined as follows.Format DescriptionKey Press the key. For example, press Enter and press Tab.Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl+Alt+A means the three keys should be pressedconcurrently.Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A meansthe two keys should be pressed in turn. Mouse OperationsThe mouse operations that may be found in this document are defined as follows.Action DescriptionClick Select and release the primary mouse button withoutmoving the pointer.Double-click Press the primary mouse button twice continuously andquickly without moving the pointer.Drag Press and hold the primary mouse button and move thepointer to a certain position.DBS3900 LampSiteSite Maintenance Guide About This DocumentIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.v
ContentsAbout This Document.....................................................................................................................ii1 Changes in DBS3900 LampSite Site Maintenance Guide..................................................... 12 Device Maintenance Items.......................................................................................................... 42.1 RHUB Maintenance Items..............................................................................................................................................52.2 pRRU Maintenance Items.............................................................................................................................................. 83 Powering On and Powering Off the RHUB........................................................................... 103.1 Powering On the RHUB............................................................................................................................................... 113.2 Powering Off the RHUB.............................................................................................................................................. 124 Powering On and Powering Off the pRRU3901....................................................................134.1 Powering On the pRRU................................................................................................................................................144.2 Powering Off the pRRU............................................................................................................................................... 165 Replacing the Devices................................................................................................................ 175.1 Replacing the RHUB.................................................................................................................................................... 185.2 Replacing an Optical Module....................................................................................................................................... 215.3 Replacing the pRRU.....................................................................................................................................................23DBS3900 LampSiteSite Maintenance Guide ContentsIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.vi
1 Changes in DBS3900 LampSite SiteMaintenance GuideThis chapter provides information about the changes in different document versions ofDBS3900 LampSite Site Maintenance Guide.07 (2016-05-30)This is the seventh commercial release.Compared with 05 (2015-10-30), no information is added.Compared with 05 (2015-10-30), this issue incorporates the following changes:Content Change Description2.2 pRRU Maintenance Items Added the informations of pRRU3902,pRRU3907, pRRU3911.5.3 Replacing the pRRU Compared with 05 (2015-10-30), this issue deletes the following new topics:lpRRU3902 Maintenance ItemslpRRU3907 Maintenance ItemslpRRU3911 Maintenance ItemslReplacing the pRRU3902lReplacing the pRRU3907lReplacing the pRRU391106 (2015-12-30)This is the sixth commercial release.Compared with 05 (2015-10-30), this issue includes the following new topics:lpRRU3911 Maintenance ItemslReplacing the pRRU3911DBS3900 LampSiteSite Maintenance Guide 1 Changes in DBS3900 LampSite Site Maintenance GuideIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.1
Compared with 05 (2015-10-30), no information is changed.Compared with 05 (2015-10-30), no information is deleted.05 (2015-10-30)This is the fifth commercial release.Compared with 04 (2015-07-30), this issue includes the following new topics:lpRRU3907 Maintenance ItemslReplacing the pRRU3907Compared with 04 (2015-07-30), no information is changed.Compared with 04 (2015-07-30), no information is deleted.04 (2015-07-30)This is the fourth commercial release.Compared with 03 (2015-06-30), no information is added.Compared with 03 (2015-06-30), this issue incorporates the following change:Content Change DescriptionEntire document Added the RHUB that has no electricaltransmission port. Compared with 03 (2015-06-30), no information is deleted.03 (2015-06-30)This is the third commercial release.Compared with 02 (2015-05-08), no information is added.Compared with 02 (2015-05-08), this issue incorporates the following change:Content Change DescriptionEntire document Added the descriptions about the DCU. Compared with 02 (2015-05-08), no information is deleted.02 (2015-05-08)This is the second commercial release.Compared with 01 (2015-03-23), no information is added.Compared with 01 (2015-03-23), this issue incorporates the following change:DBS3900 LampSiteSite Maintenance Guide 1 Changes in DBS3900 LampSite Site Maintenance GuideIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.2
Content Change Description2.2 pRRU Maintenance Items Deleted the descriptions about voltagemeasuring of the pRRU. Compared with 01 (2015-03-23), no information is deleted.01 (2015-03-23)This is the first commercial release.Compared with draft A (2015-01-15), no information is added.Compared with draft A (2015-01-15), this issue incorporates the following change:Content Change DescriptionEntire document Added the descriptions about thepRRU3902. Compared with draft A (2015-01-15), no information is deleted.Draft A (2015-01-15)This is a draft release.Compared with Issue 05 (2014-12-30) of V100R009C00, no information is added.Compared with Issue 05 (2014-12-30) of V100R009C00, this issue incorporates the followingchange:Content Change DescriptionEntire document The base station in the LampSite solution isrenamed DBS3900 LampSite. Compared with Issue 05 (2014-12-30) of V100R009C00, no information is deleted.DBS3900 LampSiteSite Maintenance Guide 1 Changes in DBS3900 LampSite Site Maintenance GuideIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.3
2 Device Maintenance ItemsAbout This ChapterThis chapter describes the device maintenance items.2.1 RHUB Maintenance ItemsThis chapter describes the RHUB maintenance items, involving the equipment room,equipment, power system, and grounding system.2.2 pRRU Maintenance ItemsThis chapter describes the pRRU maintenance items, involving equipment and power system.DBS3900 LampSiteSite Maintenance Guide 2 Device Maintenance ItemsIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.4
2.1 RHUB Maintenance ItemsThis chapter describes the RHUB maintenance items, involving the equipment room,equipment, power system, and grounding system.Equipment Room Maintenance ItemsTable 2-1 lists the equipment room maintenance items.Table 2-1 Equipment room maintenance itemsItem Check Frequency Operation ReferenceStandardEnvironment alarmsin the equipmentroomDaily Check whether anypower alarm, firealarm, or smokealarm is reported.No power alarm, firealarm, or smokealarm is reported.Temperature in theequipment roomEach timemaintenance isperformedRecord temperaturesin the equipmentroom measured by athermometer.-5°C to +50°CHumidity in theequipment roomEach timemaintenance isperformedRecord humidity inthe equipment roommeasured by ahygrometer.5%RH to 95%RHLighting system inthe equipment roomEvery other month Check whether theroutine lightingsystem andemergency lightingsystem are runningproperly.-Air conditioner Every other month Check whether theair conditioner isrunning properly.-DBS3900 LampSiteSite Maintenance Guide 2 Device Maintenance ItemsIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.5
Item Check Frequency Operation ReferenceStandardDisaster protectiondevicesEvery one month Check whether thedisaster protection,equipmentprotection, andfirefighting devicesare normal.lThe equipmentroom is equippedwith portablefoam-typeextinguishers,and the pressureand expirationdate must bechecked.lThe equipmentroom has nomice, ants, flyinginsects, or otherrisks.Cleanness Every one month Check whether thecabinet, equipmenthousing, equipmentinterior, desktop,floor, door, andwindow are cleanand tidy.All these items areclean and tidy. Equipment Maintenance ItemsTable 2-2 lists the equipment maintenance items.Table 2-2 Equipment maintenance itemsItem Check Frequency Operation ReferenceStandardFan in the PSU Monthly or quarterly Check whether thefan is workingproperly.The fan worksproperly without anyabnormal smell orsound.Equipment surface Monthly or quarterly Check whether theequipment surface isintact.The equipmentsurface is intact andthe label of thecabinet is legible.EquipmentcleannessMonthly or quarterly Check whether theequipment is clean.The equipmentsurface is clean.DBS3900 LampSiteSite Maintenance Guide 2 Device Maintenance ItemsIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.6
Item Check Frequency Operation ReferenceStandardIndicators Monthly or quarterly Check whether theindicators on theequipment areworking properly.For details about theindicator status, seeRHUB Ports andIndicators inDBS3900 LampSiteHardwareDescription.Electrostaticdischarge (ESD)wrist strapQuarterly Check the ESD wriststrap in either of thefollowing ways:lUse an ESDwrist strap testerto check the ESDwrist strap.lUse a multimeterto test the groundresistance of theESD wrist strap.If you use an ESDwrist strap tester, theGOOD indicator ison. If you use amultimeter, theground resistance ofthe ESD wrist strapranges from 0.75ohms to 10 ohms. Maintenance Items for the Power System and Grounding SystemTable 2-3 lists the maintenance items for the power system and grounding system.Table 2-3 Maintenance items for the power system and grounding systemItem Check Frequency Operation ReferenceStandardPower cables Monthly or quarterly Check the powercable connections.The power cablesare securelyconnected and notdeteriorating. Thejoints are notcorroded.Voltage Monthly or quarterly Use a multimeter tomeasure the voltageof the power supply.The voltage is in thepermissible range.PGND cables Monthly or quarterly Checks whether thePGND cables andground bar aresecurely connected.The joints are secureand not corroded.The PGND cablesand ground bar arenot deteriorated andare protected fromcorrosion.DBS3900 LampSiteSite Maintenance Guide 2 Device Maintenance ItemsIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.7
Item Check Frequency Operation ReferenceStandardGround resistance Monthly or quarterly Use a groundresistance tester tomeasure the groundresistance andrecord themeasurement result.The groundresistance is equal toor less than 10ohms. 2.2 pRRU Maintenance ItemsThis chapter describes the pRRU maintenance items, involving equipment and power system.Equipment Maintenance ItemsTable 2-4 lists the equipment maintenance items for the pRRU.Table 2-4 Equipment maintenance itemsItem Check Frequency Operation ReferenceStandardEquipment surface Monthly or quarterly Check whether theequipment surface isintact.The equipmentsurface is intact andthe label of thecabinet is legible.EquipmentcleannessMonthly or quarterly Check whether theequipment is clean.The equipmentsurface is clean.Indicators Monthly or quarterly Check whether theindicators on theequipment areworking properly.For details about theindicator status, seethe chapter of Portsand Indicators inDBS3900 LampSiteHardwareDescription. NOTEFor details about the ports and indicators of different pRRU models, see:lpRRU: pRRU3901 Ports and IndicatorslpRRU (TDD): pRRU3901 Ports and IndicatorslpRRU3902: pRRU3902 Ports and IndicatorslpRRU3907: pRRU3907 Ports and IndicatorslpRRU3911: pRRU3911 Ports and IndicatorslpRRU3911: pRRU3916 Ports and IndicatorsDBS3900 LampSiteSite Maintenance Guide 2 Device Maintenance ItemsIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.8
Power System Maintenance ItemsTable 2-5 lists the power system maintenance items for the pRRU.Table 2-5 Power system maintenance itemsItem Check Frequency Operation ReferenceStandardPower cables Monthly or quarterly Check the powercable connections.The power cablesare securelyconnected and notdeteriorating. Thejoints are notcorroded.DBS3900 LampSiteSite Maintenance Guide 2 Device Maintenance ItemsIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.9
3 Powering On and Powering Off the RHUBAbout This ChapterAfter the RHUB is powered on, check the indicator status. Power off the RHUB in normal oremergency mode as required.3.1 Powering On the RHUBThe RHUB is powered by AC input.3.2 Powering Off the RHUBAn RHUB can be powered off in two ways: normal power-off and emergency power-off. Youneed to perform a normal power-off in scenarios such as an equipment swap or foreseeableregional blackout, and you need to perform an emergency power-off in emergencies such as afire, smoke, or water damage in indoor scenarios.DBS3900 LampSiteSite Maintenance Guide 3 Powering On and Powering Off the RHUBIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.10
3.1 Powering On the RHUBThe RHUB is powered by AC input.PrerequisitesThe power cable of the RHUB is not connected to power, that is, the power plug is removed.ContextNOTICEThe RHUB must be powered on within 7 days after it is unpacked, and the period of itspower-off state cannot exceed 7 days during maintenance.ProcedureStep 1 Insert the power plug to power on the RHUB.Step 2 Wait 3 to 5 minutes. Then check the status of the RUN indicator.If the RUN Indicator Is... It Indicates that... Then...Steady on There is power input, but theboard is faulty.Disable the power supply,rectify the board fault, andthen power on the RHUBagain.Steady off There is no power input, oran alarm about the board isreported.Disable the power supplyand check the power inputagain. If the power input isnormal, rectify the boardfault, and then power on theRHUB again.1s on and 1s off The RHUB is runningproperly.End the power-on checktask.0.125s on and 0.125s off The board software is beingloaded.If the loading is notcomplete after 5 minutes,disable the power supplyand check whether the datain the configuration file iscorrect. Rectify the fault andthen power on the RHUBagain. ----EndDBS3900 LampSiteSite Maintenance Guide 3 Powering On and Powering Off the RHUBIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.11
3.2 Powering Off the RHUBAn RHUB can be powered off in two ways: normal power-off and emergency power-off. Youneed to perform a normal power-off in scenarios such as an equipment swap or foreseeableregional blackout, and you need to perform an emergency power-off in emergencies such as afire, smoke, or water damage in indoor scenarios.ProcedurelNormal power-offNOTICEPowering off the RHUB interrupts services, and therefore perform associated operationsbefore a power-off.a. Remove the power plug to disconnect the RHUB with the external power input.b. If the RHUB is equipped with an external power device, turn off the switch of theexternal power device.lEmergency power-offa. Turn off the switch of the external power device.----EndDBS3900 LampSiteSite Maintenance Guide 3 Powering On and Powering Off the RHUBIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.12
4 Powering On and Powering Off thepRRU3901About This ChapterAfter the pRRU3901 is powered on, check the power supply voltage and indicator status.Power off the pRRU3901 based on the power supply mode.4.1 Powering On the pRRUAfter the pRRU is powered on, check its running status by observing the indicator status.4.2 Powering Off the pRRUA pRRU can be powered off in two ways: normal power-off and emergency power-off. Youneed to perform a normal power-off in scenarios such as an equipment swap or foreseeableregional blackout, and you need to perform an emergency power-off in emergencies such as afire, smoke, or water damage in indoor scenarios.DBS3900 LampSiteSite Maintenance Guide 4 Powering On and Powering Off the pRRU3901Issue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.13
4.1 Powering On the pRRUAfter the pRRU is powered on, check its running status by observing the indicator status.PrerequisitesThe pRRU and the cables are correctly installed.ContextNOTEThe pRRU must be powered on within 7 days after it is unpacked, and the period of its power-off state cannotexceed 7 days during maintenance.ProcedureStep 1 Power on the pRRU.The pRRU can be powered in PoE mode. The RHUB adopts the PoE power supply to providepower for the pRRU over the CPRI_E0 port.Step 2 Wait 3 to 5 minutes. Then Check the status of the RUN indicator on the pRRU3901 or 3GPPindicator on the pRRU3902, pRRU3907 and pRRU3911.Module If the RUNIndicator Is...It Indicates that... Then...pRRU3901 Steady on There is powerinput, but the boardis faulty.Disable the powersupply, rectify theboard fault, and thenpower on thepRRU3901 again.Steady off There is no powerinput.Disable the powersupply and check thepower input again.On for 1s and off for1sThe pRRU3901 isrunning properly.End the power-oncheck task.On for 0.125s andoff for 0.125sThe board softwareis being loaded.If the loading is notcomplete after 5minutes, disable thepower supply. Checkwhether the data inthe configurationfile is correct.Rectify the fault andthen power on thepRRU3901 again.DBS3900 LampSiteSite Maintenance Guide 4 Powering On and Powering Off the pRRU3901Issue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.14
Module If the RUNIndicator Is...It Indicates that... Then...pRRU3902/pRRU3907/pRRU3911/pRRU3916Blinks white at 4 Hz The pRRU isloading software,configuring data, orit is not running.Wait until thesoftware is loaded.If the loading is notcompleted in fiveminutes, power offthe pRRU and checkwhether the dataconfiguration file iscorrect. After thefault is rectified,power on the pRRUagain.Blinks white at 0.5Hz (on for 1s and offfor 1s)The pRRU isworking properlyand does nottransmit power.Check whether theservices have beenconfigured andpower amplificationhave been enabledon the pRRU.Is steady white The cell is set upand transmits powerproperly.No further action isrequired.Is steady orange. There is powerinput, but thehardware is faulty.Power off thepRRU, rectify thehardware fault, andthen power it onagain.Blinks orange at 0.5Hz (on for 1s and offfor 1s)A minor alarm(indicating anHDLC linkdisconnection, forexample) isgenerated.Troubleshoot basedon the alarminformation.Is off The board is notpowered on.Turn off the powersupply switch andcheck whether thepower input isnormal. If the powerinput is normal,check for and rectifyboard faults, andturn on the powersupply switch again. ----EndDBS3900 LampSiteSite Maintenance Guide 4 Powering On and Powering Off the pRRU3901Issue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.15
4.2 Powering Off the pRRUA pRRU can be powered off in two ways: normal power-off and emergency power-off. Youneed to perform a normal power-off in scenarios such as an equipment swap or foreseeableregional blackout, and you need to perform an emergency power-off in emergencies such as afire, smoke, or water damage in indoor scenarios.ProcedurelNormal power-offNOTICEPowering off the pRRU interrupts services, and therefore perform associated operationsbefore a power-off.a. Remove the Ethernet cable.lEmergency power-offa. Turn off the switch of the external power device.----EndDBS3900 LampSiteSite Maintenance Guide 4 Powering On and Powering Off the pRRU3901Issue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.16
5 Replacing the DevicesAbout This ChapterThis chapter describes the procedures and cautions when replacing the devices.5.1 Replacing the RHUBThe RHUB is an indoor convergence unit. It converges multiple pRRUs to the BBU.Replacing the RHUB interrupts services carried on the serving cell. RHUBs are classified intothose with electrical transmission ports and those with no electrical transmission ports. Unlessotherwise specified, this document uses the RHUBs with no electrical transmission ports as anexample.5.2 Replacing an Optical ModuleAn optical module provides a port for opto-electronic conversion. This enables thetransmission between the RHUB and BBU3900 through the optical fiber. Replacing theoptical module requires removing the optical fibers. This interrupts all the services.5.3 Replacing the pRRUpRRU is an indoor remote radio unit. It processes RF signals. Replacing the pRRU interruptsall the services carried on it.DBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.17
5.1 Replacing the RHUBThe RHUB is an indoor convergence unit. It converges multiple pRRUs to the BBU.Replacing the RHUB interrupts services carried on the serving cell. RHUBs are classified intothose with electrical transmission ports and those with no electrical transmission ports. Unlessotherwise specified, this document uses the RHUBs with no electrical transmission ports as anexample.PrerequisiteslA new RHUB is available.lThe labels and connections of the cables connected to the RHUB are recorded.lThe following tools are available: a Phillips screwdriver, an ESD wrist strap, and arubber mallet.ContextIt takes about 10 minutes to replace the RHUB.ProcedurelReplace the RHUB installed on a 19-inch rack, in a 19-inch cabinet or in a 19-Inch Shelf.NOTEThe procedures for replacing the RHUB installed on a 19-inch rack are the same for replacing theRHUB installed in a 19-inch cabinet or in a 19-Inch Shelf. The following uses the RHUB installedon a 19-inch rack as an example.a. Power off the RHUB by referring to 3.2 Powering Off the RHUB.b. Record the cable connections.c. Take insulation measures, and then remove all cables from the RHUB.d. Use a torque screwdriver or Phillips screwdriver to remove the four screws on themounting ear of the RHUB, as shown in Figure 5-1.Figure 5-1 Removing the mounting earDBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.18
e. Remove the RHUB from the rack.f. Install the new RHUB. For details, see DBS3900 LampSite Installation Guide.NOTICETake proper ESD protection measures, such as wearing an ESD wrist strap or ESDgloves to prevent electrostatic damage to the boards, modules, or electroniccomponents.g. Connect all the cables to the new RHUB according to the recorded installations.h. Power on the RHUB by referring to 3.1 Powering On the RHUB.i. Determine whether the new RHUB is working properly according to the indicatorstatus on the RHUB. For details about the indicator status, see RHUB Ports andIndicators in DBS3900 LampSite Hardware Description.lReplace the RHUB installed on a wall.a. Power off the RHUB by referring to 3.2 Powering Off the RHUB.b. Record the cable connections.c. Take insulation measures, and then remove all cables from the RHUB.d. Use a torque wrench or socket wrench to remove the four expansion bolts on themounting ear, and then remove the RHUB, as shown in Figure 5-2.DBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.19
Figure 5-2 Removing the mounting eare. Install the new RHUB on a wall. For details, see DBS3900 LampSite InstallationGuide.NOTICETake proper ESD protection measures, such as wearing an ESD wrist strap or ESDgloves to prevent electrostatic damage to the boards, modules, or electroniccomponents.f. Connect all the cables to the new RHUB according to the recorded installations.g. Power on the RHUB by referring to 3.1 Powering On the RHUB.h. Determine whether the new RHUB is working properly according to the indicatorstatus on the RHUB. For details about the indicator status, see RHUB Ports andIndicators in DBS3900 LampSite Hardware Description.----EndDBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.20
Follow-up ProcedurelPlace the replaced RHUB into an ESD box or bag. Then, place the ESD box or bag into afoam-padded carton or the packing box of the new optical module.lRecord the information about the faulty component in the fault card.lContact the local Huawei office to deal with the faulty component.5.2 Replacing an Optical ModuleAn optical module provides a port for opto-electronic conversion. This enables thetransmission between the RHUB and BBU3900 through the optical fiber. Replacing theoptical module requires removing the optical fibers. This interrupts all the services.PrerequisiteslThe number and type of faulty optical modules are confirmed, and new optical modulesare available. The new optical modules to be installed must match CPRI rates.lThe position for installing an optical module and the cable connection are recorded.lThe following tools and materials are available: an ESD wrist strap or ESD gloves, andan ESD box or bag.ContextlThe optical modules are connected to the CPRI0 and CPRI1 ports on the RHUB panel.lAn optical module or CPRI fiber optic cable cannot be inserted into or removed fromthis CPRI port when the power supply is connected.lReplacing an optical module involves removing an optical fiber and the faulty opticalmodule, installing a new optical module, connecting the optical fiber to the opticalmodule, and recovering the links. The operation takes about 10 minutes.NOTETake proper ESD protection measures, such as wearing an ESD wrist strap or ESD gloves to preventelectrostatic damage to the boards, modules, or electronic components.ProcedureStep 1 Wear ESD gloves.Step 2 Record the optical module and fiber connections.Step 3 Power off the RHUB according to the instructions in 3.2 Powering Off the RHUB.NOTEAfter removing the optical fiber from the optical module, do not look directly at the optical modules withouteye protection.Step 4 Press the latch on the connector of the optical fiber connector, and remove the connector fromthe faulty optical module, use the dust-proof cap to protect the optical fiber, as shown inFigure 5-3.DBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.21
Figure 5-3 Removing the optical fiberStep 5 Turn the ring-pull on the faulty optical module outwards. Hold the ring-pull and take thefaulty optical module out of the slot to remove it from the CPRI0 or CPRI1 port, as shown inFigure 5-4.Figure 5-4 Removing the optical moduleStep 6 Install the new optical module onto the corresponding CPRI port, as shown in Figure 5-5.Figure 5-5 Installing the new optical moduleStep 7 Remove the dust-proof caps from the optical module and optical fiber, and connect the opticalfiber connector to the new optical module, as shown in Figure 5-6.DBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.22
Figure 5-6 Installing the optical fiberStep 8 Power on the RRU according to the instructions in 3.1 Powering On the RHUB.Step 9 Check whether CPRI signal transmission recovers by observing the CPRI indicator on theRHUB panel.If... Then...The CPRI indicator is green CPRI signal transmission recovers and theoptical fiber replacement is successful.The CPRI indicator is red or in anothercolorCPRI signal transmission is abnormal.Check whether the optical fiber and opticalmodule are securely installed. Step 10 Take off the ESD gloves and pack up all the tools.----EndFollow-up ProcedurelPlace the replaced optical module into an ESD box or bag. Then, place the ESD box orbag into a foam-padded carton or the packing box of the new optical module.lRecord the information about the faulty component in the fault card.lContact the local Huawei office to deal with the faulty component.5.3 Replacing the pRRUpRRU is an indoor remote radio unit. It processes RF signals. Replacing the pRRU interruptsall the services carried on it.PrerequisiteslReplacing the pRRU when:DBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.23
–The functional modules inside a pRRU or the housing of pRRU is damaged.–Adding the RF daughter board or Wi-Fi daughter board.lThe hardware type is confirmed and a new pRRU is available.lThe labels and connections of the cables connected to the pRRU are recorded.lThe following tools are available: an electrostatic discharge (ESD) wrist strap and ESDgloves.ContextIt takes about 5 minutes to replace the pRRU.NOTEThe pRRU can be installed on a metal pole, wall, or ceiling, and the procedures for replacing the pRRUare almost the same. The following uses a ceiling-mounted pRRU as an example.ProcedureStep 1 Instruct the network operator to block the pRRU.NOTEThe DBS3900 LampSite solution supports immediate block, idle block, and delayed block. Application ofidle block and delayed block produces the same effect as application of immediate block.lpRRU3901:–On the UMTS side, log in to the LMT and run the BLK BRD command to blockthe RF daughter board of the pRRU.–On the LTE side, log in to the LMT and run the BLK BRD command to block theRF daughter board of the pRRU.lpRRU3902/pRRU3907/pRRU3911/pRRU3916:–On the UMTS side, log in to the LMT and run the BLK BRD command to block thepRRU.–On the LTE side, log in to the LMT and run the BLK BRD command to block thepRRU.Step 2 Wear ESD gloves.NOTElTake proper ESD protection measures, such as wearing ESD gloves to prevent electrostatic damage to theboards, modules, or electronic components.lA pRRU that has just been powered off has afterheat. Take scald-proof measures when removing thepRRU.Step 3 Power off the pRRU. For details, see 4.2 Powering Off the pRRU.Step 4 Removing the pRRU to be replaced.1. Record the cable connections.2. Take insulation measures, and then remove all cables from the pRRU.3. Removing the pRRU.–Removing the pRRU3901. Hold the pRRU3901 case in one hand and pull the hoistclamp on the mounting bracket with the other hand, as shown in step a in Figure5-7. Then, remove the mounting bracket from the pRRU3901, as shown in step b inFigure 5-7.DBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.24
Figure 5-7 Removing the pRRU3901–Removing the pRRU3902or pRRU3911. Hold the pRRU case in one hand andapply force to the hoist clamp on the mounting bracket with the other hand, asshown in step a in Figure 5-7. Then, remove the mounting bracket from the pRRU,as shown in step b in Figure 5-8.Figure 5-8 Removing the pRRU–Removing the pRRU3907or pRRU3916. Remove the two dowels on the top of theattachment plate from the mounting kit, and push the pRRU upwards, as shown byillustrations b and c in Figure 5-9.DBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.25
NOTICEWhen removing the pRRU, hold the pRRU handle with one hand and support thebottom of the pRRU with the other hand. This prevents personnel injury caused byany falling pRRU.Figure 5-9 Removing the pRRUStep 5 Install the new pRRU.1. Install the new pRRU. The installation must be based on different scenarios. For details,see DBS3900 LampSite Installation Guide.2. Connect the cables to the pRRU according to the recorded positions.NOTICETake proper ESD protection measures, such as wearing an ESD wrist strap or ESDgloves to prevent electrostatic damage to the boards, modules, or electronic components.Step 6 Optional: Instruct the network operator to run MOD AP, change the faulty pRRU WIFIMAC to the new pRRU WIFI MAC in AC Window, when pRRU with three transmissionports is configured with Wi-Fi daughter board.DBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.26
Step 7 Power on the pRRU by referring to 4.1 Powering On the pRRU.Step 8 Check whether the new pRRU is working properly according to the indicator status on thepRRU. For details about the indicator status, see the chapter of Ports and Indicators inDBS3900 LampSite Hardware Description.NOTEFor details about the ports and indicators of different pRRU models, see:lpRRU: pRRU3901 Ports and IndicatorslpRRU (TDD): pRRU3901 Ports and IndicatorslpRRU3902: pRRU3902 Ports and IndicatorslpRRU3907: pRRU3907 Ports and IndicatorslpRRU3911: pRRU3911 Ports and IndicatorslpRRU3911: pRRU3916 Ports and IndicatorsStep 9 Instruct the network operator to unblock the pRRU.lpRRU3901:–On the UMTS side, log in to the NodeB LMT and run the UBL BRD command tounblock the RF daughter board of the pRRU.–On the LTE side, log in to the eNodeB LMT and run the UBL BRD command tounblock the RF daughter board of the pRRU.lpRRU3902/pRRU3907/pRRU3911/pRRU3916:–On the UMTS side, log in to the NodeB LMT and run the UBL BRD command tounblock the pRRU.–On the LTE side, log in to the eNodeB LMT and run the UBL BRD command tounblock the pRRU.Step 10 Take off the ESD gloves and pack up all the tools.----EndDBS3900 LampSiteSite Maintenance Guide 5 Replacing the DevicesIssue 07 (2016-05-30) Huawei Proprietary and ConfidentialCopyright © Huawei Technologies Co., Ltd.27