Huawei Technologies PRRU3916 pico Remote Radio Unit User Manual Site Maintenance Guide
Huawei Technologies Co.,Ltd pico Remote Radio Unit Site Maintenance Guide
Contents
User manual I
DBS3900 LampSite Site Maintenance Guide Issue 07 Date 2016-05-30 HUAWEI TECHNOLOGIES CO., LTD. Copyright © Huawei Technologies Co., Ltd. 2016. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide About This Document About This Document Overview This document describes routine maintenance items for a BBU, DCU3900, RHUB3908, pRRU3901, pRRU3902, pRRU3907 and pRRU3911, such as equipment maintenance, and power-on and power-off operations. It also explains how to replace the components and modules. NOTE l Unless otherwise specified, BBU in this document refers to BBU3900 and BBU3910. For details of the BBU site maintenance guide, see DBS3900 Site Maintenance Guide. l DCU3900 referred to as DCU in this document. For details about the hardware maintenance guide of the DCU, see DCU3900 Hardware Maintenance Guide. l RHUB3908 referred to as RHUB in this document. l Unless otherwise specified, pRRU in this document refers to pRRU3901, pRRU3902, pRRU3907 and pRRU3911. Product Version The following table lists the product version related to this document. Product Name Solution Version Product Version DBS3900 LampSite l SRAN10.1 and later versions V100R010C10 and later versions l RAN17.1 and later versions l eRAN8.1 and later versions l eRAN TDD 8.1 and later versions Intended Audience This document is intended for: Issue 07 (2016-05-30) System engineers Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. ii DBS3900 LampSite Site Maintenance Guide About This Document Site maintenance engineers Organization 1 Changes in DBS3900 LampSite Site Maintenance Guide This chapter provides information about the changes in different document versions of DBS3900 LampSite Site Maintenance Guide. 2 Device Maintenance Items This chapter describes the device maintenance items. 3 Powering On and Powering Off the RHUB After the RHUB is powered on, check the indicator status. Power off the RHUB in normal or emergency mode as required. 4 Powering On and Powering Off the pRRU3901 After the pRRU3901 is powered on, check the power supply voltage and indicator status. Power off the pRRU3901 based on the power supply mode. 5 Replacing the Devices This chapter describes the procedures and cautions when replacing the devices. Conventions Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results. NOTICE is used to address practices not related to personal injury. Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. iii DBS3900 LampSite Site Maintenance Guide About This Document Symbol Description Calls attention to important information, best practices and tips. NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration. General Conventions The general conventions that may be found in this document are defined as follows. Convention Description Times New Roman Normal paragraphs are in Times New Roman. Boldface Names of files, directories, folders, and users are in boldface. For example, log in as user root. Italic Book titles are in italics. Courier New Examples of information displayed on the screen are in Courier New. Command Conventions The command conventions that may be found in this document are defined as follows. Convention Description Boldface The keywords of a command line are in boldface. Italic Command arguments are in italics. [] Items (keywords or arguments) in brackets [ ] are optional. { x | y | ... } Optional items are grouped in braces and separated by vertical bars. One item is selected. [ x | y | ... ] Optional items are grouped in brackets and separated by vertical bars. One item is selected or no item is selected. { x | y | ... }* Optional items are grouped in braces and separated by vertical bars. A minimum of one item or a maximum of all items can be selected. [ x | y | ... ]* Optional items are grouped in brackets and separated by vertical bars. Several items or no item can be selected. GUI Conventions Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. iv DBS3900 LampSite Site Maintenance Guide About This Document The GUI conventions that may be found in this document are defined as follows. Convention Description Boldface Buttons, menus, parameters, tabs, window, and dialog titles are in boldface. For example, click OK. Multi-level menus are in boldface and separated by the ">" signs. For example, choose File > Create > Folder. Keyboard Operations The keyboard operations that may be found in this document are defined as follows. Format Description Key Press the key. For example, press Enter and press Tab. Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl +Alt+A means the three keys should be pressed concurrently. Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A means the two keys should be pressed in turn. Mouse Operations The mouse operations that may be found in this document are defined as follows. Issue 07 (2016-05-30) Action Description Click Select and release the primary mouse button without moving the pointer. Double-click Press the primary mouse button twice continuously and quickly without moving the pointer. Drag Press and hold the primary mouse button and move the pointer to a certain position. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide Contents Contents About This Document.....................................................................................................................ii 1 Changes in DBS3900 LampSite Site Maintenance Guide..................................................... 1 2 Device Maintenance Items.......................................................................................................... 4 2.1 RHUB Maintenance Items..............................................................................................................................................5 2.2 pRRU Maintenance Items.............................................................................................................................................. 8 3 Powering On and Powering Off the RHUB........................................................................... 10 3.1 Powering On the RHUB............................................................................................................................................... 11 3.2 Powering Off the RHUB.............................................................................................................................................. 12 4 Powering On and Powering Off the pRRU3901....................................................................13 4.1 Powering On the pRRU................................................................................................................................................ 14 4.2 Powering Off the pRRU............................................................................................................................................... 16 5 Replacing the Devices................................................................................................................ 17 5.1 Replacing the RHUB.................................................................................................................................................... 18 5.2 Replacing an Optical Module....................................................................................................................................... 21 5.3 Replacing the pRRU..................................................................................................................................................... 23 Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. vi DBS3900 LampSite Site Maintenance Guide 1 Changes in DBS3900 LampSite Site Maintenance Guide Changes in DBS3900 LampSite Site Maintenance Guide This chapter provides information about the changes in different document versions of DBS3900 LampSite Site Maintenance Guide. 07 (2016-05-30) This is the seventh commercial release. Compared with 05 (2015-10-30), no information is added. Compared with 05 (2015-10-30), this issue incorporates the following changes: Content Change Description 2.2 pRRU Maintenance Items Added the informations of pRRU3902, pRRU3907, pRRU3911. 5.3 Replacing the pRRU Compared with 05 (2015-10-30), this issue deletes the following new topics: pRRU3902 Maintenance Items pRRU3907 Maintenance Items pRRU3911 Maintenance Items Replacing the pRRU3902 Replacing the pRRU3907 Replacing the pRRU3911 06 (2015-12-30) This is the sixth commercial release. Compared with 05 (2015-10-30), this issue includes the following new topics: pRRU3911 Maintenance Items Replacing the pRRU3911 Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide 1 Changes in DBS3900 LampSite Site Maintenance Guide Compared with 05 (2015-10-30), no information is changed. Compared with 05 (2015-10-30), no information is deleted. 05 (2015-10-30) This is the fifth commercial release. Compared with 04 (2015-07-30), this issue includes the following new topics: pRRU3907 Maintenance Items Replacing the pRRU3907 Compared with 04 (2015-07-30), no information is changed. Compared with 04 (2015-07-30), no information is deleted. 04 (2015-07-30) This is the fourth commercial release. Compared with 03 (2015-06-30), no information is added. Compared with 03 (2015-06-30), this issue incorporates the following change: Content Change Description Entire document Added the RHUB that has no electrical transmission port. Compared with 03 (2015-06-30), no information is deleted. 03 (2015-06-30) This is the third commercial release. Compared with 02 (2015-05-08), no information is added. Compared with 02 (2015-05-08), this issue incorporates the following change: Content Change Description Entire document Added the descriptions about the DCU. Compared with 02 (2015-05-08), no information is deleted. 02 (2015-05-08) This is the second commercial release. Compared with 01 (2015-03-23), no information is added. Compared with 01 (2015-03-23), this issue incorporates the following change: Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide 1 Changes in DBS3900 LampSite Site Maintenance Guide Content Change Description 2.2 pRRU Maintenance Items Deleted the descriptions about voltage measuring of the pRRU. Compared with 01 (2015-03-23), no information is deleted. 01 (2015-03-23) This is the first commercial release. Compared with draft A (2015-01-15), no information is added. Compared with draft A (2015-01-15), this issue incorporates the following change: Content Change Description Entire document Added the descriptions about the pRRU3902. Compared with draft A (2015-01-15), no information is deleted. Draft A (2015-01-15) This is a draft release. Compared with Issue 05 (2014-12-30) of V100R009C00, no information is added. Compared with Issue 05 (2014-12-30) of V100R009C00, this issue incorporates the following change: Content Change Description Entire document The base station in the LampSite solution is renamed DBS3900 LampSite. Compared with Issue 05 (2014-12-30) of V100R009C00, no information is deleted. Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide 2 Device Maintenance Items Device Maintenance Items About This Chapter This chapter describes the device maintenance items. 2.1 RHUB Maintenance Items This chapter describes the RHUB maintenance items, involving the equipment room, equipment, power system, and grounding system. 2.2 pRRU Maintenance Items This chapter describes the pRRU maintenance items, involving equipment and power system. Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide 2 Device Maintenance Items 2.1 RHUB Maintenance Items This chapter describes the RHUB maintenance items, involving the equipment room, equipment, power system, and grounding system. Equipment Room Maintenance Items Table 2-1 lists the equipment room maintenance items. Table 2-1 Equipment room maintenance items Issue 07 (2016-05-30) Item Check Frequency Operation Reference Standard Environment alarms in the equipment room Daily Check whether any power alarm, fire alarm, or smoke alarm is reported. No power alarm, fire alarm, or smoke alarm is reported. Temperature in the equipment room Each time maintenance is performed Record temperatures in the equipment room measured by a thermometer. -5°C to +50°C Humidity in the equipment room Each time maintenance is performed Record humidity in the equipment room measured by a hygrometer. 5%RH to 95%RH Lighting system in the equipment room Every other month Check whether the routine lighting system and emergency lighting system are running properly. Air conditioner Every other month Check whether the air conditioner is running properly. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide 2 Device Maintenance Items Item Check Frequency Operation Reference Standard Disaster protection devices Every one month Check whether the disaster protection, equipment protection, and firefighting devices are normal. l The equipment room is equipped with portable foam-type extinguishers, and the pressure and expiration date must be checked. l The equipment room has no mice, ants, flying insects, or other risks. Cleanness Every one month Check whether the cabinet, equipment housing, equipment interior, desktop, floor, door, and window are clean and tidy. All these items are clean and tidy. Equipment Maintenance Items Table 2-2 lists the equipment maintenance items. Table 2-2 Equipment maintenance items Issue 07 (2016-05-30) Item Check Frequency Operation Reference Standard Fan in the PSU Monthly or quarterly Check whether the fan is working properly. The fan works properly without any abnormal smell or sound. Equipment surface Monthly or quarterly Check whether the equipment surface is intact. The equipment surface is intact and the label of the cabinet is legible. Equipment cleanness Monthly or quarterly Check whether the equipment is clean. The equipment surface is clean. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide 2 Device Maintenance Items Item Check Frequency Operation Reference Standard Indicators Monthly or quarterly Check whether the indicators on the equipment are working properly. For details about the indicator status, see RHUB Ports and Indicators in DBS3900 LampSite Hardware Description. Electrostatic discharge (ESD) wrist strap Quarterly Check the ESD wrist strap in either of the following ways: If you use an ESD wrist strap tester, the GOOD indicator is on. If you use a multimeter, the ground resistance of the ESD wrist strap ranges from 0.75 ohms to 10 ohms. l Use an ESD wrist strap tester to check the ESD wrist strap. l Use a multimeter to test the ground resistance of the ESD wrist strap. Maintenance Items for the Power System and Grounding System Table 2-3 lists the maintenance items for the power system and grounding system. Table 2-3 Maintenance items for the power system and grounding system Issue 07 (2016-05-30) Item Check Frequency Operation Reference Standard Power cables Monthly or quarterly Check the power cable connections. The power cables are securely connected and not deteriorating. The joints are not corroded. Voltage Monthly or quarterly Use a multimeter to measure the voltage of the power supply. The voltage is in the permissible range. PGND cables Monthly or quarterly Checks whether the PGND cables and ground bar are securely connected. The joints are secure and not corroded. The PGND cables and ground bar are not deteriorated and are protected from corrosion. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide 2 Device Maintenance Items Item Check Frequency Operation Reference Standard Ground resistance Monthly or quarterly Use a ground resistance tester to measure the ground resistance and record the measurement result. The ground resistance is equal to or less than 10 ohms. 2.2 pRRU Maintenance Items This chapter describes the pRRU maintenance items, involving equipment and power system. Equipment Maintenance Items Table 2-4 lists the equipment maintenance items for the pRRU. Table 2-4 Equipment maintenance items Item Check Frequency Operation Reference Standard Equipment surface Monthly or quarterly Check whether the equipment surface is intact. The equipment surface is intact and the label of the cabinet is legible. Equipment cleanness Monthly or quarterly Check whether the equipment is clean. The equipment surface is clean. Indicators Monthly or quarterly Check whether the indicators on the equipment are working properly. For details about the indicator status, see the chapter of Ports and Indicators in DBS3900 LampSite Hardware Description. NOTE For details about the ports and indicators of different pRRU models, see: l pRRU: pRRU3901 Ports and Indicators l pRRU (TDD): pRRU3901 Ports and Indicators l pRRU3902: pRRU3902 Ports and Indicators l pRRU3907: pRRU3907 Ports and Indicators l pRRU3911: pRRU3911 Ports and Indicators l pRRU3911: pRRU3916 Ports and Indicators Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide 2 Device Maintenance Items Power System Maintenance Items Table 2-5 lists the power system maintenance items for the pRRU. Table 2-5 Power system maintenance items Issue 07 (2016-05-30) Item Check Frequency Operation Reference Standard Power cables Monthly or quarterly Check the power cable connections. The power cables are securely connected and not deteriorating. The joints are not corroded. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. DBS3900 LampSite Site Maintenance Guide 3 Powering On and Powering Off the RHUB Powering On and Powering Off the RHUB About This Chapter After the RHUB is powered on, check the indicator status. Power off the RHUB in normal or emergency mode as required. 3.1 Powering On the RHUB The RHUB is powered by AC input. 3.2 Powering Off the RHUB An RHUB can be powered off in two ways: normal power-off and emergency power-off. You need to perform a normal power-off in scenarios such as an equipment swap or foreseeable regional blackout, and you need to perform an emergency power-off in emergencies such as a fire, smoke, or water damage in indoor scenarios. Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 10 DBS3900 LampSite Site Maintenance Guide 3 Powering On and Powering Off the RHUB 3.1 Powering On the RHUB The RHUB is powered by AC input. Prerequisites The power cable of the RHUB is not connected to power, that is, the power plug is removed. Context NOTICE The RHUB must be powered on within 7 days after it is unpacked, and the period of its power-off state cannot exceed 7 days during maintenance. Procedure Step 1 Insert the power plug to power on the RHUB. Step 2 Wait 3 to 5 minutes. Then check the status of the RUN indicator. If the RUN Indicator Is... It Indicates that... Then... Steady on There is power input, but the board is faulty. Disable the power supply, rectify the board fault, and then power on the RHUB again. Steady off There is no power input, or an alarm about the board is reported. Disable the power supply and check the power input again. If the power input is normal, rectify the board fault, and then power on the RHUB again. 1s on and 1s off The RHUB is running properly. End the power-on check task. 0.125s on and 0.125s off The board software is being loaded. If the loading is not complete after 5 minutes, disable the power supply and check whether the data in the configuration file is correct. Rectify the fault and then power on the RHUB again. ----End Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 11 DBS3900 LampSite Site Maintenance Guide 3 Powering On and Powering Off the RHUB 3.2 Powering Off the RHUB An RHUB can be powered off in two ways: normal power-off and emergency power-off. You need to perform a normal power-off in scenarios such as an equipment swap or foreseeable regional blackout, and you need to perform an emergency power-off in emergencies such as a fire, smoke, or water damage in indoor scenarios. Procedure Normal power-off NOTICE Powering off the RHUB interrupts services, and therefore perform associated operations before a power-off. a. Remove the power plug to disconnect the RHUB with the external power input. b. If the RHUB is equipped with an external power device, turn off the switch of the external power device. Emergency power-off a. Turn off the switch of the external power device. ----End Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 12 DBS3900 LampSite Site Maintenance Guide 4 Powering On and Powering Off the pRRU3901 Powering On and Powering Off the pRRU3901 About This Chapter After the pRRU3901 is powered on, check the power supply voltage and indicator status. Power off the pRRU3901 based on the power supply mode. 4.1 Powering On the pRRU After the pRRU is powered on, check its running status by observing the indicator status. 4.2 Powering Off the pRRU A pRRU can be powered off in two ways: normal power-off and emergency power-off. You need to perform a normal power-off in scenarios such as an equipment swap or foreseeable regional blackout, and you need to perform an emergency power-off in emergencies such as a fire, smoke, or water damage in indoor scenarios. Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 13 DBS3900 LampSite Site Maintenance Guide 4 Powering On and Powering Off the pRRU3901 4.1 Powering On the pRRU After the pRRU is powered on, check its running status by observing the indicator status. Prerequisites The pRRU and the cables are correctly installed. Context NOTE The pRRU must be powered on within 7 days after it is unpacked, and the period of its power-off state cannot exceed 7 days during maintenance. Procedure Step 1 Power on the pRRU. The pRRU can be powered in PoE mode. The RHUB adopts the PoE power supply to provide power for the pRRU over the CPRI_E0 port. Step 2 Wait 3 to 5 minutes. Then Check the status of the RUN indicator on the pRRU3901 or 3GPP indicator on the pRRU3902, pRRU3907 and pRRU3911. Issue 07 (2016-05-30) Module If the RUN Indicator Is... It Indicates that... Then... pRRU3901 Steady on There is power input, but the board is faulty. Disable the power supply, rectify the board fault, and then power on the pRRU3901 again. Steady off There is no power input. Disable the power supply and check the power input again. On for 1s and off for 1s The pRRU3901 is running properly. End the power-on check task. On for 0.125s and off for 0.125s The board software is being loaded. If the loading is not complete after 5 minutes, disable the power supply. Check whether the data in the configuration file is correct. Rectify the fault and then power on the pRRU3901 again. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 14 DBS3900 LampSite Site Maintenance Guide 4 Powering On and Powering Off the pRRU3901 Module If the RUN Indicator Is... It Indicates that... Then... pRRU3902/ pRRU3907/ pRRU3911/ pRRU3916 Blinks white at 4 Hz The pRRU is loading software, configuring data, or it is not running. Wait until the software is loaded. If the loading is not completed in five minutes, power off the pRRU and check whether the data configuration file is correct. After the fault is rectified, power on the pRRU again. Blinks white at 0.5 Hz (on for 1s and off for 1s) The pRRU is working properly and does not transmit power. Check whether the services have been configured and power amplification have been enabled on the pRRU. Is steady white The cell is set up and transmits power properly. No further action is required. Is steady orange. There is power input, but the hardware is faulty. Power off the pRRU, rectify the hardware fault, and then power it on again. Blinks orange at 0.5 Hz (on for 1s and off for 1s) A minor alarm (indicating an HDLC link disconnection, for example) is generated. Troubleshoot based on the alarm information. Is off The board is not powered on. Turn off the power supply switch and check whether the power input is normal. If the power input is normal, check for and rectify board faults, and turn on the power supply switch again. ----End Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 15 DBS3900 LampSite Site Maintenance Guide 4 Powering On and Powering Off the pRRU3901 4.2 Powering Off the pRRU A pRRU can be powered off in two ways: normal power-off and emergency power-off. You need to perform a normal power-off in scenarios such as an equipment swap or foreseeable regional blackout, and you need to perform an emergency power-off in emergencies such as a fire, smoke, or water damage in indoor scenarios. Procedure Normal power-off NOTICE Powering off the pRRU interrupts services, and therefore perform associated operations before a power-off. a. Remove the Ethernet cable. Emergency power-off a. Turn off the switch of the external power device. ----End Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 16 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices Replacing the Devices About This Chapter This chapter describes the procedures and cautions when replacing the devices. 5.1 Replacing the RHUB The RHUB is an indoor convergence unit. It converges multiple pRRUs to the BBU. Replacing the RHUB interrupts services carried on the serving cell. RHUBs are classified into those with electrical transmission ports and those with no electrical transmission ports. Unless otherwise specified, this document uses the RHUBs with no electrical transmission ports as an example. 5.2 Replacing an Optical Module An optical module provides a port for opto-electronic conversion. This enables the transmission between the RHUB and BBU3900 through the optical fiber. Replacing the optical module requires removing the optical fibers. This interrupts all the services. 5.3 Replacing the pRRU pRRU is an indoor remote radio unit. It processes RF signals. Replacing the pRRU interrupts all the services carried on it. Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 17 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices 5.1 Replacing the RHUB The RHUB is an indoor convergence unit. It converges multiple pRRUs to the BBU. Replacing the RHUB interrupts services carried on the serving cell. RHUBs are classified into those with electrical transmission ports and those with no electrical transmission ports. Unless otherwise specified, this document uses the RHUBs with no electrical transmission ports as an example. Prerequisites A new RHUB is available. The labels and connections of the cables connected to the RHUB are recorded. The following tools are available: a Phillips screwdriver, an ESD wrist strap, and a rubber mallet. Context It takes about 10 minutes to replace the RHUB. Procedure Replace the RHUB installed on a 19-inch rack, in a 19-inch cabinet or in a 19-Inch Shelf. NOTE The procedures for replacing the RHUB installed on a 19-inch rack are the same for replacing the RHUB installed in a 19-inch cabinet or in a 19-Inch Shelf. The following uses the RHUB installed on a 19-inch rack as an example. a. Power off the RHUB by referring to 3.2 Powering Off the RHUB. b. Record the cable connections. c. Take insulation measures, and then remove all cables from the RHUB. d. Use a torque screwdriver or Phillips screwdriver to remove the four screws on the mounting ear of the RHUB, as shown in Figure 5-1. Figure 5-1 Removing the mounting ear Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 18 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices e. Remove the RHUB from the rack. f. Install the new RHUB. For details, see DBS3900 LampSite Installation Guide. NOTICE Take proper ESD protection measures, such as wearing an ESD wrist strap or ESD gloves to prevent electrostatic damage to the boards, modules, or electronic components. Issue 07 (2016-05-30) g. Connect all the cables to the new RHUB according to the recorded installations. h. Power on the RHUB by referring to 3.1 Powering On the RHUB. i. Determine whether the new RHUB is working properly according to the indicator status on the RHUB. For details about the indicator status, see RHUB Ports and Indicators in DBS3900 LampSite Hardware Description. Replace the RHUB installed on a wall. a. Power off the RHUB by referring to 3.2 Powering Off the RHUB. b. Record the cable connections. c. Take insulation measures, and then remove all cables from the RHUB. d. Use a torque wrench or socket wrench to remove the four expansion bolts on the mounting ear, and then remove the RHUB, as shown in Figure 5-2. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 19 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices Figure 5-2 Removing the mounting ear e. Install the new RHUB on a wall. For details, see DBS3900 LampSite Installation Guide. NOTICE Take proper ESD protection measures, such as wearing an ESD wrist strap or ESD gloves to prevent electrostatic damage to the boards, modules, or electronic components. f. Connect all the cables to the new RHUB according to the recorded installations. g. Power on the RHUB by referring to 3.1 Powering On the RHUB. h. Determine whether the new RHUB is working properly according to the indicator status on the RHUB. For details about the indicator status, see RHUB Ports and Indicators in DBS3900 LampSite Hardware Description. ----End Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 20 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices Follow-up Procedure Place the replaced RHUB into an ESD box or bag. Then, place the ESD box or bag into a foam-padded carton or the packing box of the new optical module. Record the information about the faulty component in the fault card. Contact the local Huawei office to deal with the faulty component. 5.2 Replacing an Optical Module An optical module provides a port for opto-electronic conversion. This enables the transmission between the RHUB and BBU3900 through the optical fiber. Replacing the optical module requires removing the optical fibers. This interrupts all the services. Prerequisites The number and type of faulty optical modules are confirmed, and new optical modules are available. The new optical modules to be installed must match CPRI rates. The position for installing an optical module and the cable connection are recorded. The following tools and materials are available: an ESD wrist strap or ESD gloves, and an ESD box or bag. The optical modules are connected to the CPRI0 and CPRI1 ports on the RHUB panel. An optical module or CPRI fiber optic cable cannot be inserted into or removed from this CPRI port when the power supply is connected. Replacing an optical module involves removing an optical fiber and the faulty optical module, installing a new optical module, connecting the optical fiber to the optical module, and recovering the links. The operation takes about 10 minutes. Context NOTE Take proper ESD protection measures, such as wearing an ESD wrist strap or ESD gloves to prevent electrostatic damage to the boards, modules, or electronic components. Procedure Step 1 Wear ESD gloves. Step 2 Record the optical module and fiber connections. Step 3 Power off the RHUB according to the instructions in 3.2 Powering Off the RHUB. NOTE After removing the optical fiber from the optical module, do not look directly at the optical modules without eye protection. Step 4 Press the latch on the connector of the optical fiber connector, and remove the connector from the faulty optical module, use the dust-proof cap to protect the optical fiber, as shown in Figure 5-3. Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 21 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices Figure 5-3 Removing the optical fiber Step 5 Turn the ring-pull on the faulty optical module outwards. Hold the ring-pull and take the faulty optical module out of the slot to remove it from the CPRI0 or CPRI1 port, as shown in Figure 5-4. Figure 5-4 Removing the optical module Step 6 Install the new optical module onto the corresponding CPRI port, as shown in Figure 5-5. Figure 5-5 Installing the new optical module Step 7 Remove the dust-proof caps from the optical module and optical fiber, and connect the optical fiber connector to the new optical module, as shown in Figure 5-6. Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 22 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices Figure 5-6 Installing the optical fiber Step 8 Power on the RRU according to the instructions in 3.1 Powering On the RHUB. Step 9 Check whether CPRI signal transmission recovers by observing the CPRI indicator on the RHUB panel. If... Then... The CPRI indicator is green CPRI signal transmission recovers and the optical fiber replacement is successful. The CPRI indicator is red or in another color CPRI signal transmission is abnormal. Check whether the optical fiber and optical module are securely installed. Step 10 Take off the ESD gloves and pack up all the tools. ----End Follow-up Procedure Place the replaced optical module into an ESD box or bag. Then, place the ESD box or bag into a foam-padded carton or the packing box of the new optical module. Record the information about the faulty component in the fault card. Contact the local Huawei office to deal with the faulty component. 5.3 Replacing the pRRU pRRU is an indoor remote radio unit. It processes RF signals. Replacing the pRRU interrupts all the services carried on it. Prerequisites Issue 07 (2016-05-30) Replacing the pRRU when: Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 23 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices – The functional modules inside a pRRU or the housing of pRRU is damaged. – Adding the RF daughter board or Wi-Fi daughter board. The hardware type is confirmed and a new pRRU is available. The labels and connections of the cables connected to the pRRU are recorded. The following tools are available: an electrostatic discharge (ESD) wrist strap and ESD gloves. Context It takes about 5 minutes to replace the pRRU. NOTE The pRRU can be installed on a metal pole, wall, or ceiling, and the procedures for replacing the pRRU are almost the same. The following uses a ceiling-mounted pRRU as an example. Procedure Step 1 Instruct the network operator to block the pRRU. NOTE The DBS3900 LampSite solution supports immediate block, idle block, and delayed block. Application of idle block and delayed block produces the same effect as application of immediate block. pRRU3901: – On the UMTS side, log in to the LMT and run the BLK BRD command to block the RF daughter board of the pRRU. – On the LTE side, log in to the LMT and run the BLK BRD command to block the RF daughter board of the pRRU. pRRU3902/pRRU3907/pRRU3911/pRRU3916: – On the UMTS side, log in to the LMT and run the BLK BRD command to block the pRRU. – On the LTE side, log in to the LMT and run the BLK BRD command to block the pRRU. Step 2 Wear ESD gloves. NOTE l Take proper ESD protection measures, such as wearing ESD gloves to prevent electrostatic damage to the boards, modules, or electronic components. l A pRRU that has just been powered off has afterheat. Take scald-proof measures when removing the pRRU. Step 3 Power off the pRRU. For details, see 4.2 Powering Off the pRRU. Step 4 Removing the pRRU to be replaced. 1. Record the cable connections. 2. Take insulation measures, and then remove all cables from the pRRU. 3. Removing the pRRU. – Issue 07 (2016-05-30) Removing the pRRU3901. Hold the pRRU3901 case in one hand and pull the hoist clamp on the mounting bracket with the other hand, as shown in step a in Figure 5-7. Then, remove the mounting bracket from the pRRU3901, as shown in step b in Figure 5-7. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 24 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices Figure 5-7 Removing the pRRU3901 – Removing the pRRU3902or pRRU3911. Hold the pRRU case in one hand and apply force to the hoist clamp on the mounting bracket with the other hand, as shown in step a in Figure 5-7. Then, remove the mounting bracket from the pRRU, as shown in step b in Figure 5-8. Figure 5-8 Removing the pRRU – Issue 07 (2016-05-30) Removing the pRRU3907or pRRU3916. Remove the two dowels on the top of the attachment plate from the mounting kit, and push the pRRU upwards, as shown by illustrations b and c in Figure 5-9. Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 25 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices NOTICE When removing the pRRU, hold the pRRU handle with one hand and support the bottom of the pRRU with the other hand. This prevents personnel injury caused by any falling pRRU. Figure 5-9 Removing the pRRU Step 5 Install the new pRRU. 1. Install the new pRRU. The installation must be based on different scenarios. For details, see DBS3900 LampSite Installation Guide. 2. Connect the cables to the pRRU according to the recorded positions. NOTICE Take proper ESD protection measures, such as wearing an ESD wrist strap or ESD gloves to prevent electrostatic damage to the boards, modules, or electronic components. Step 6 Optional: Instruct the network operator to run MOD AP, change the faulty pRRU WIFI MAC to the new pRRU WIFI MAC in AC Window, when pRRU with three transmission ports is configured with Wi-Fi daughter board. Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 26 DBS3900 LampSite Site Maintenance Guide 5 Replacing the Devices Step 7 Power on the pRRU by referring to 4.1 Powering On the pRRU. Step 8 Check whether the new pRRU is working properly according to the indicator status on the pRRU. For details about the indicator status, see the chapter of Ports and Indicators in DBS3900 LampSite Hardware Description. NOTE For details about the ports and indicators of different pRRU models, see: l pRRU: pRRU3901 Ports and Indicators l pRRU (TDD): pRRU3901 Ports and Indicators l pRRU3902: pRRU3902 Ports and Indicators l pRRU3907: pRRU3907 Ports and Indicators l pRRU3911: pRRU3911 Ports and Indicators l pRRU3911: pRRU3916 Ports and Indicators Step 9 Instruct the network operator to unblock the pRRU. pRRU3901: – On the UMTS side, log in to the NodeB LMT and run the UBL BRD command to unblock the RF daughter board of the pRRU. – On the LTE side, log in to the eNodeB LMT and run the UBL BRD command to unblock the RF daughter board of the pRRU. pRRU3902/pRRU3907/pRRU3911/pRRU3916: – On the UMTS side, log in to the NodeB LMT and run the UBL BRD command to unblock the pRRU. – On the LTE side, log in to the eNodeB LMT and run the UBL BRD command to unblock the pRRU. Step 10 Take off the ESD gloves and pack up all the tools. ----End Issue 07 (2016-05-30) Huawei Proprietary and Confidential Copyright © Huawei Technologies Co., Ltd. 27
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : Huawei Technologies Co., Ltd. Create Date : 2016:06:15 20:16:29+08:00 Modify Date : 2016:06:15 20:16:29+08:00 Creator : AH Formatter V6.2 MR8 for Windows : 6.2.10.20473 (2015/04/14 10:00JST) Producer : Antenna House PDF Output Library 6.2.680 (Windows) Title : Site Maintenance Guide Subject : Site Maintenance Guide Trapped : False Page Count : 34 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools