HUAWEI TECHNOLOGIES Co., Ltd.Issue: 02Part Number: 31504691Date: 2009-07-31RRU3201 V100R001C01 Installation Guide
1Safety Information …………………………………………….….……Installation Tools ………………………………………….…………..Space Requirements …………………………………….……..…….Installation Modes …………………………………………………….Installation Procedure …………………………………….………….Components Delivered with the RRU ……………………………..Installing the RRU on a Metal Pole ………………..……………….Installing the RRU on a Wall ………………………………………..Installing the RRU on a U-Steel ……………….……….…………..Installing the RRU on an Angle Steel ……………………………..Installing the RRU Cables …………………………………………..RRU Hardware Installation Checklist ……………………………..Powering On the RRU …………………………………...…………..Reference ………………………………………………………..……..Change History …………………………………...…………………..ContentsCopyright © Huawei Technologies Co., Ltd. 2009. All rights reserved.2345667912121319192026
2Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved.Following All Safety PrecautionsBefore any operation, read the instructions and precautions in this document carefully to minimize the possibility of accidents.The Danger, Caution, and Note items in the documents do not cover all the safety precautions that must be followed. They only provide the generic safety precautions for operations.When operating Huawei products and equipment, you must comply with safety precautions and special safety instructions related to corresponding equipment provided by Huawei. The safety precautions in the document are related to only Huawei products. Huawei is not liable for any consequence that results from the violation of universal regulations for safety operations and safety codes on design, production, and equipment use. Complying with the Local Safety RegulationsWhen operating the device, comply with the local safety regulations. The safety precautions provided in the documents are supplementary. You must comply with the local safety regulations.Qualified Personnel OnlyThe personnel in charge of installation and maintenance must be trained and master the correct operating methods and safety precautions before beginning work.SymbolsSafety of Personnel• The high voltage power supply provides power for running the system. Direct contact with the high voltage power supply or contact through damp objects may result in fatal danger.• Non-standard and improper high voltage operations may result in fire and electric shock.• In a thunderstorm, do not perform operations on high voltage and AC power supply facilities or on a steel tower and mast.• Ground the device before powering on the device. Otherwise, the personnel and device are in danger.• Power off the device before performing operations on the power supply equipment.• High power radio-frequency signals are harmful to human body. Before installing or maintaining an antenna on a steel tower or mast with a large number of transmitter antennas, the operator should coordinate with all parties to ensure that the transmitter antennas are shut down.• When handling optical fibers, do not stand close to, or look into the optical fiber outlet with unaided eyes.• Protect yourself when drilling holes. Flying dust may hurt your eyes or you may inhale the dust.• Power off the batteries before connecting the cables to the batteries. Otherwise, casualties may occur. • When working at a height, be cautious about falling objects.Device Safety• Check the electrical connection of the device before operation and ensure that the device is reliably grounded.• The static electricity generated by the human body may damage the electrostatic sensitive components on the circuit board, such as the large-scale integrated circuit (LIC). Wear an ESD wrist strap or ESD gloves when performing the operation.• When working on batteries, take measures to prevent short circuits in the batteries and electrolyte spill/loss. The electrolyte may erode metal and boards, or even cause rust of the equipment or short circuits in the boards.• When the equipment is unpacked, it must be powered on in 24 hours. The maximum duration of the power-off state of the equipment is 24 hours during maintenance.Safety InformationIndicates a hazard with a high level of risk, which if not avoided,will result in death or serious injury.DANGERWARNINGCAUTIONTIPNOTEIndicates a hazard with a medium or low level of risk, which if not avoided, could result in minor or moderate injury.Indicates a potentially hazardous situation, which if not avoided,could result in equipment damage, data loss, performance degradation, or unexpected results.Indicates a tip that may help you solve a problem or save time.Provides additional information to emphasize or supplement important points of the main text.
3Installation ToolsAdjustable wrench(with the diameter of at least 32 mm)Torque screwdriverMeasuring tapeVacuum cleanerWire StripperLevelMarkerMultimeterClaw hammerESD glovesCombination wrench(21mm~21mm) for pole installationPower cable crimping tool Cable cutterHeat gunHammer drillKnife(17mm~17mm) for pole installationFlat-head screwdriver (M3 to M6)Phillips screwdriver (M3~M6)
4Space Requirements (Unit: mm)abcRRU DimensionsRecommended Clearance for a Single RRU Minimum Clearance for a Single RRU480356 170≥300≥600≥800≥500≥300200400600300100Installation ModesOn a metal pole On a wall On a U-steel On a U-steel
5Installation ModesMetal pole Angle steel U-steelThe following figures show the installations of multiple RRUs on the metal poles.The RRU can be installed on the tower. For details, see page 26 Lifting the RRU and Installation Components to the Tower.60mm~114mm63mm~80mm63mm ~80mm30mm~50mm50mm~100mm63mm~80mm30mm~50mmThe following figure shows the specifications of the metal pole, angle steel, and U-steel where the RRU is installed.zA maximum of two RRUs can be installed on a metal pole with a diameter of 60 mm to 76 mm, and the installation mode must be standard mode. Three or more RRUs must be installed on a metal pole with a diameter of 76 mm to 114 mm in a centralized way. zIt is recommended that only one RRU be installed on a U-steel or angle steel.zWhen installed on a tower, one RRU can be installed only in standard mode or reverse mode rather than side-mounted. Two RRUs cannot be installed in back-to-back mode.When the RRU is installed on a U-steel or angle steel, the angle between the U-steel or angle steel and the longitudinal direction cannot exceed 10 degrees.installation carrier
6StartEndInstall the RRU on a metal pole(page 7~11)Install the RRU on a wall(page 12~14)Install the RRU on a U-steel(page15)Install the RRU on a angle steel(page15)Install the RRU cables(page16~22)Power on the RRU(page 23)Check the installation(page 23)Components Delivered with the RRUFixture assembly for installing the RRU Back of the RRUAttachment plateM10x110 BoltMain fixtureAuxiliary fixtureInstallation ProcedureInstalling the RRU on a Metal PoleInstalling a Single RRU in Ordinary ModeaArrow1. Before installing the main fixture, ensure that the contact piece on the fixture is fixed.2. When installing the main fixture, keep the arrow on the main fixture upward. It is recommended that the bottom of the main fixture be 1200 mm to 1600 mm above the ground for easy maintenance.
7Installing the RRU on a Metal PoleInstalling a Single RRU in Ordinary Modea2. Install the auxiliary fixture between the nuts of the dual-nut bolt assembly on the main fixture.Dual-nut bolt assembly Ensure that the arrow on the auxiliary fixture is upward.You can fit the auxiliary fixture on one of the dual-nut bolt assemblies before the installation. Thus, you can simply install the auxiliary fixture by fitting the other end of it on the other dual-nut bolt assembly.Fit the auxiliary fixture into the dual-nut bolt assemblies.3. Use an adjustable wrench (with the diameter of at least 21 mm) to tighten the dual-nut bolt assemblies. In this way, the main and auxiliary fixtures are securely mounted on the pole.40N•mWhen tightening the nuts, ensure that the two dual-nut bolt assemblies are tightened simultaneously. The fastening torque is 40 N• m.
8Installing the RRU on a Metal Pole4. Install the RRU on the main fixture.1. When you perform this operation, you need to place the foam pads or paper under the RRU to avoid any damage to the shell.2. The RF port at the bottom of the RRU does not have load bearing capacity. Do not place the RRU on the ground on its bottom during the installation.The screw is a non-fixed one and is for removing the RRU.Installing Two RRUs in Back-To-Back Modeb2. Install the main fixture of another RRU. Ensure that the main and auxiliary fixtures are perfectly fitted.1. Install an RRU first. For details, see page 7 Installing a Single RRU in Ordinary Mode.
9Installing the RRU on a Metal PoleInstalling Two RRUs in Back-To-Back Modeb3. Install the second RRU on the main fixture in reverse mode.Ordinary mode Ordinary modeInstalling the RRU on a Wall1. Place the auxiliary fixture on the wall at the installation position , use a level bar to measure the levelness of the fixture, and then mark the anchor points by using a marking pen.It is recommended that the bottom of the auxiliary fixture be 1200 mm to 1600 mm above the ground.Level barRRU
1052~60mm90°Ø1420~30mmInstalling the RRU on a Wall2. Drill holes at the anchor points and then install the expansion bolt assemblies.After the expansion bolt is removed, dispose of the plastic tube.Do not hammer the bolt entirely into the expansion tube, and leave 20 mm to 30 mm of the bolt outside the wall.When RRUs are installed on a wall, the specifications of the wall are as follows: zFor one RRU, the wall has a weight-bearing capacity of 76 kg.zThe fastening torque of the expansion bolt reaches 30 N·m, the expansion bolt works properly, and no damages such as cracks are on the wall. Bolt M10x65Flat washer 10Spring washer 10Expansion tubePlastic tube3. Fit the auxiliary fixture on the expansion bolts downward, and then tighten the bolts by using a combination wrench (with the diameter of at least 17 mm).30N•mM10X65Ensure that the arrow on the auxiliary fixture is upward.
11Installing the RRU on a Wall4. Install the main fixture.5. Install the RRU. 6. Install Multiple RRUs.
12Installing the RRU on a U-SteelThe procedure for installing the RRU on a U-steel is the same as that for installing the RRU on a metal pole.Installing the RRU on an Angle SteelThe procedure for installing the RRU on an angle steel is the same as that for installing the RRU on a metal pole.Angle steelTop viewTop viewU-Steel
13Installing the RRU CablesRRU Cable ConnectionsaStandard AISG female connector of the AISG multi-wire cableStandard AISG male connectorStandard AISG male connector of the AISG extension cable or RCUStandard AISG female connectorPort labeled RET/MON on the RRUWaterproof DB9 connectorAISG multi-wire cablePort labeled RET/MON at the bottom of the RRUDB9 male connectorAlarm cableExternal alarm devicesEight cord end terminalsThe connectors labeled 2A and 2B are connected to port labeled CPRI0, CPRI1 or CPRI2 on the LBBP board of the BBU.DLC connectorCPRI optical cableThe connectors labeled 1A and 1B are connected to  the optical module on the port labeled CPRI_W on the RRUDLC connectorAISG extension cable Standard AISG male connector of the RCUStandard AISG female connectorThe blue OT terminal is connected to socket labeled NEG(-)0 in the RRU cabling cavity. And the black OT terminal is connected to socket labeled RTN(+)0.Two OT terminals(M4)Power cableExternal power supplyBare wireFeeder or antennaDIN male connectorPorts labeled ANT_TX/RXA and ANT_TX/RXB on the RRU(Only the ANT_TX/RXA port supports the OOK signal).DIN male connectorAntenna jumperNearest grounding barOT  terminalGrounding bolt on the RRUOT  terminal(M6)PGND cable(16mm2 )Connector to…Connector TypeCableCable List
14Installing the RRU CablesRRU Cable ConnectionsaThe RET/MON port on the RRU is multi-functional, and can be installed with either AISG multi-wire cable or alarm cable. When the length of the AISG multi-wire cable is not enough, you can choose the optional AISG extension cable. PGND cableAntenna jumperPower cableCPRI optical cableAISG multi-wire cableAlarm cableAISG extension cableAntennaBBUSingle RRURCUFor detail information of the cable, see Cable List on Page 13.External power system External monitoring deviceAntennaAntennaAntennaPGND cableAntenna jumperPower cableCPRI optical cableAISG multi-wire cableAlarm cableAISG extension cableMultiple RRURCU