Huawei Technologies RRU3201-700M Distributed Base Station Remote Radio Unit User Manual Installation Guide 1

Huawei Technologies Co.,Ltd Distributed Base Station Remote Radio Unit Installation Guide 1

Contents

Installation Guide 1

Download: Huawei Technologies RRU3201-700M Distributed Base Station Remote Radio Unit User Manual Installation Guide 1
Mirror Download [FCC.gov]Huawei Technologies RRU3201-700M Distributed Base Station Remote Radio Unit User Manual Installation Guide 1
Document ID1166330
Application IDWLCMK3Fe9LnouZudQh4fQA==
Document DescriptionInstallation Guide 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize143.58kB (1794792 bits)
Date Submitted2009-09-09 00:00:00
Date Available2009-12-05 00:00:00
Creation Date2009-09-09 08:49:04
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2009-09-09 08:49:27
Document TitleMicrosoft PowerPoint - RRU3201 Installation Guide-(V100R001C01_01).ppt
Document CreatorPScript5.dll Version 5.2
Document Author: y00111561

RRU3201 V100R001C01
Installation Guide
Issue: 02
Part Number: 31504691
Date: 2009-07-31
HUAWEI TECHNOLOGIES Co., Ltd.
Contents
Safety Information …………………………………………….….……
Installation Tools ………………………………………….…………..
Space Requirements …………………………………….……..…….
Installation Modes …………………………………………………….
Installation Procedure …………………………………….………….
Components Delivered with the RRU ……………………………..
Installing the RRU on a Metal Pole ………………..……………….
Installing the RRU on a Wall ………………………………………..
Installing the RRU on a U-Steel ……………….……….…………..
12
Installing the RRU on an Angle Steel ……………………………..
12
Installing the RRU Cables …………………………………………..
13
RRU Hardware Installation Checklist ……………………………..
19
Powering On the RRU …………………………………...…………..
19
Reference ………………………………………………………..……..
20
Change History …………………………………...…………………..
26
Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved.
Safety Information
Following All Safety Precautions
Before any operation, read the instructions and precautions in this document carefully to minimize the possibility
of accidents.
The Danger, Caution, and Note items in the documents do not cover all the safety precautions that must be
followed. They only provide the generic safety precautions for operations.
When operating Huawei products and equipment, you must comply with safety precautions and special safety
instructions related to corresponding equipment provided by Huawei. The safety precautions in the document
are related to only Huawei products. Huawei is not liable for any consequence that results from the violation of
universal regulations for safety operations and safety codes on design, production, and equipment use.
Complying with the Local Safety Regulations
When operating the device, comply with the local safety regulations. The safety precautions provided in the
documents are supplementary. You must comply with the local safety regulations.
Qualified Personnel Only
The personnel in charge of installation and maintenance must be trained and master the correct operating
methods and safety precautions before beginning work.
Symbols
DANGER
Indicates a hazard with a high level of risk, which if not avoided,will result in death or
serious injury.
WARNING
Indicates a hazard with a medium or low level of risk, which if not avoided, could result
in minor or moderate injury.
CAUTION
Indicates a potentially hazardous situation, which if not avoided,could result in
equipment damage, data loss, performance degradation, or unexpected results.
TIP
Indicates a tip that may help you solve a problem or save time.
NOTE
Provides additional information to emphasize or supplement important points of the
main text.
Safety of Personnel
• The high voltage power supply provides power for running the system. Direct contact with the high voltage
power supply or contact through damp objects may result in fatal danger.
• Non-standard and improper high voltage operations may result in fire and electric shock.
• In a thunderstorm, do not perform operations on high voltage and AC power supply facilities or on a steel
tower and mast.
• Ground the device before powering on the device. Otherwise, the personnel and device are in danger.
• Power off the device before performing operations on the power supply equipment.
• High power radio-frequency signals are harmful to human body. Before installing or maintaining an antenna
on a steel tower or mast with a large number of transmitter antennas, the operator should coordinate with all
parties to ensure that the transmitter antennas are shut down.
• When handling optical fibers, do not stand close to, or look into the optical fiber outlet with unaided eyes.
• Protect yourself when drilling holes. Flying dust may hurt your eyes or you may inhale the dust.
• Power off the batteries before connecting the cables to the batteries. Otherwise, casualties may occur.
• When working at a height, be cautious about falling objects.
Device Safety
• Check the electrical connection of the device before operation and ensure that the device is reliably grounded.
• The static electricity generated by the human body may damage the electrostatic sensitive components on
the circuit board, such as the large-scale integrated circuit (LIC). Wear an ESD wrist strap or ESD gloves when
performing the operation.
• When working on batteries, take measures to prevent short circuits in the batteries and electrolyte spill/loss.
The electrolyte may erode metal and boards, or even cause rust of the equipment or short circuits in the boards.
• When the equipment is unpacked, it must be powered on in 24 hours. The maximum duration of the poweroff state of the equipment is 24 hours during maintenance.
Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved.
Installation Tools
Hammer drill
ESD gloves
Vacuum cleaner
Heat gun
Phillips screwdriver (M3~M6)
Flat-head screwdriver (M3 to M6)
Claw hammer
Knife
Wire Stripper
Adjustable wrench
Power cable crimping tool
Cable cutter
(with the diameter of at least 32 mm)
Combination wrench
(21mm~21mm) for pole installation
Level
Multimeter
Torque screwdriver
Marker
(17mm~17mm) for pole installation
Measuring tape
Space Requirements (Unit: mm)
a RRU Dimensions
356
170
480
Recommended Clearance for a
Single RRU
Minimum Clearance for a Single
RRU
≥300
200
≥3
00
100
≥6
00
00
≥8
400
60
≥500
300
Installation Modes
On a metal pole
On a wall
On a U-steel
On a U-steel
Installation Modes
30mm ~ 50mm
60mm~114mm
63mm~80mm
The following figure shows the specifications of the metal pole, angle steel, and U-steel where the RRU is installed.
~
~
50mm~100mm
Metal pole
63mm ~ 80mm
Angle steel
U-steel
z A maximum of two RRUs can be installed on a metal pole with a diameter of 60 mm to 76 mm, and the installation mode
must be standard mode. Three or more RRUs must be installed on a metal pole with a diameter of 76 mm to 114 mm in a
centralized way.
z It is recommended that only one RRU be installed on a U-steel or angle steel.
z When installed on a tower, one RRU can be installed only in standard mode or reverse mode rather than side-mounted.
Two RRUs cannot be installed in back-to-back mode.
When the RRU is installed
on a U-steel or angle steel,
the angle between the Usteel or angle steel and the
longitudinal direction
cannot exceed 10 degrees.
installation carrier
The RRU can be installed on the tower. For details, see page 26 Lifting the RRU and Installation
Components to the Tower.
The following figures show the installations of multiple RRUs on the metal poles.
Installation Procedure
Start
Install the RRU on a
metal pole
(page 7~11)
Install the RRU on a
wall
(page 12~14)
Install the RRU on a
U-steel
(page15)
Install the RRU on a
angle steel
(page15)
Install the RRU cables
(page16~22)
Check the installation
(page 23)
Power on the RRU
(page 23)
End
Components Delivered with the RRU
Attachment plate
Auxiliary
fixture
Main fixture
M10x110 Bolt
Fixture assembly for installing the RRU
Back of the RRU
Installing the RRU on a Metal Pole
a Installing a Single RRU in Ordinary Mode
1. Before installing the main fixture, ensure that the contact piece
on the fixture is fixed.
2. When installing the main fixture, keep the arrow on the main
fixture upward.
Arrow
It is recommended that the bottom of the main fixture be 1200
mm to 1600 mm above the ground for easy maintenance.
Installing the RRU on a Metal Pole
a Installing a Single RRU in Ordinary Mode
2. Install the auxiliary fixture between the nuts of the dual-nut bolt assembly on the main fixture.
Ensure that the
arrow
on
the
auxiliary fixture is
upward.
Dual-nut bolt
assembly
You can fit the auxiliary fixture on one of the dual-nut bolt assemblies before the installation. Thus, you can simply
install the auxiliary fixture by fitting the other end of it on the other dual-nut bolt assembly.
Fit the auxiliary fixture into the dual-nut bolt assemblies.
3. Use an adjustable wrench (with the diameter of at least 21 mm) to tighten the dual-nut bolt
assemblies. In this way, the main and auxiliary fixtures are securely mounted on the pole.
40N•m
When tightening the nuts, ensure that the two dual-nut bolt assemblies are tightened simultaneously. The fastening torque is
40 N• m.
Installing the RRU on a Metal Pole
4. Install the RRU on the main fixture.
The screw is a nonfixed one and is for
removing the RRU.
1. When you perform this operation, you need to place the foam pads or paper under the RRU to avoid any damage to
the shell.
2. The RF port at the bottom of the RRU does not have load bearing capacity. Do not place the RRU on the ground on
its bottom during the installation.
Installing Two RRUs in Back-To-Back Mode
1. Install an RRU first. For details, see
page 7 Installing a Single RRU in
Ordinary Mode.
2. Install the main fixture of another RRU.
Ensure that the main and auxiliary fixtures
are perfectly fitted.
Installing the RRU on a Metal Pole
Installing Two RRUs in Back-To-Back Mode
3. Install the second RRU on the main fixture in reverse mode.
Ordinary mode
Ordinary mode
Installing the RRU on a Wall
1. Place the auxiliary fixture on the wall at the installation position , use a level bar to measure
the levelness of the fixture, and then mark the anchor points by using a marking pen.
Level bar
RRU
It is recommended that the bottom of the auxiliary fixture be 1200 mm to 1600 mm above the ground.
Installing the RRU on a Wall
2. Drill holes at the anchor points and then install the expansion bolt assemblies.
Bolt M10x65
Ø14
Plastic tube
Flat washer 10
Expansion tube
90°
52~60mm
Spring washer 10
After the expansion bolt
is removed, dispose of
the plastic tube.
Do not hammer the bolt
entirely into the expansion
tube, and leave 20 mm to
30 mm of the bolt outside
the wall.
20~30mm
When RRUs are installed on a wall, the specifications of the wall are as follows:
z For one RRU, the wall has a weight-bearing capacity of 76 kg.
z The fastening torque of the expansion bolt reaches 30 N·m, the expansion bolt works properly, and no damages
such as cracks are on the wall.
3. Fit the auxiliary fixture on the expansion bolts downward, and then tighten the bolts by using
a combination wrench (with the diameter of at least 17 mm).
M10X65
Ensure that the arrow
on the auxiliary fixture
is upward.
30N•m
10
Installing the RRU on a Wall
4. Install the main fixture.
5. Install the RRU.
6. Install Multiple RRUs.
11
Installing the RRU on a U-Steel
U-Steel
Top view
The procedure for installing the RRU on a U-steel is the same as that for installing the RRU on a metal pole.
Installing the RRU on an Angle Steel
Angle
steel
Top view
The procedure for installing the RRU on an angle steel is the same as that for installing the RRU on a metal pole.
12
Installing the RRU Cables
a RRU Cable Connections
Cable List
Cable
PGND
cable
Connector Type
Connector to…
OT terminal(M6)
Grounding bolt on the RRU
OT terminal
Nearest grounding bar
DIN male connector
Ports labeled ANT_TX/RXA and ANT_TX/RXB on the
(16mm2 )
Antenna
RRU
jumper
(Only the ANT_TX/RXA port supports the OOK
signal).
Power
cable
DIN male connector
Feeder or antenna
Two OT terminals
The blue OT terminal is connected to socket labeled
(M4)
NEG(-)0 in the RRU cabling cavity. And the black OT
terminal is connected to socket labeled RTN(+)0.
CPRI
Bare wire
External power supply
DLC connector
The connectors labeled 1A and 1B are connected to
optical cable
the optical module on the port labeled CPRI_W on the
RRU
DLC connector
The connectors labeled 2A and 2B are connected to
port labeled CPRI0, CPRI1 or CPRI2 on the LBBP
board of the BBU.
Alarm cable
AISG multiwire cable
AISG
extension
cable
DB9 male connector
Port labeled RET/MON at the bottom of the RRU
Eight cord end terminals
External alarm devices
Waterproof DB9
Port labeled RET/MON on the RRU
connector
Standard AISG female
Standard AISG male connector of the AISG extension
connector
cable or RCU
Standard AISG male
Standard AISG female connector of the AISG multi-
connector
wire cable
Standard AISG female
Standard AISG male connector of the RCU
connector
13
Installing the RRU Cables
a RRU Cable Connections
Single RRU
Antenna
PGND cable
Antenna jumper
Power cable
CPRI optical cable
Alarm cable
RCU
AISG multi-wire cable
The RET/MON port on the RRU is
multi-functional, and can be installed
with either AISG multi-wire cable or
alarm cable. When the length of the
AISG multi-wire cable is not enough,
you can choose the optional AISG
extension cable.
AISG extension cable
BBU
Antenna
Antenna
Antenna
Multiple RRU
PGND cable
Antenna jumper
RCU
Power cable
CPRI optical cable
Alarm cable
AISG multi-wire cable
AISG extension cable
External power system
External monitoring device
For detail information of the cable, see Cable List on Page 13.
14

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
Modify Date                     : 2009:09:09 08:49:27+08:00
Create Date                     : 2009:09:09 08:49:04+08:00
Metadata Date                   : 2009:09:09 08:49:27+08:00
Creator Tool                    : PScript5.dll Version 5.2
Format                          : application/pdf
Title                           : Microsoft PowerPoint - RRU3201 Installation Guide-(V100R001C01_01).ppt
Creator                         : y00111561
Document ID                     : uuid:2ff5f4cd-0d1b-4f44-b1cc-90454a55d284
Instance ID                     : uuid:0042f5f1-9ef1-4b8a-8d9b-ff115a2204a5
Producer                        : Acrobat Distiller 7.0 (Windows)
Page Count                      : 15
Author                          : y00111561
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QISRRU3201-700M

Navigation menu