Figure 3-28 Installing the second mounting plateCAUTIONThe tab on the left of the second mounting plate must be fitted into the anchorslot in the middle of the first mounting plate.5. Use two screws M6 x 20 to secure the second mounting plate on the first one, as shownin Figure 3-29.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-27
Figure 3-29 Securing the second mounting plate on the first onelRear-mounted installation1. Install the first mounting plate by referring to 3.4.1.1 Installing the Mounting Plateof the Single RRU3804 on the Metal Pole.2. Use the holes numbered 1.3. Secure the multi-purpose attachment plate on the second mounting plate at the upperpart of its back.4. Install the second mounting plate by fitting the tabs on the mounting plate into theanchor slots in the upper pole fixture on the other side, as shown in Figure 3-30.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-28 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-30 Installing the second mounting plate5. Lead each bolt M10 x 110 through the spring washer 10, flat washer 10, and insulatingwasher in turn. Use the two bolts to secure the second mounting plate on the lowerpole fixture, as shown in Figure 3-31.Figure 3-31 Securing the second mounting plate----EndRRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-29
 Installing the Mounting Plates of the Two RRU3804s on the WallThis describes how to install the mounting plates on the wall.ProcedureStep 1 Install the first mounting plate by referring to 3.4.1.2 Installing the Mounting Plate of theSingle RRU3804 on the Wall.Step 2 Use the holes numbered 2 in Figure 3-32.Figure 3-32 Holes in the multi-purpose attachment plateStep 3 Use two screws M6 x 20 to secure the multi-purpose attachment plate at the bottom of the secondmounting plate, as shown in Figure 3-33.Figure 3-33 Securing the multi-purpose attachment plate at the bottom of the second mountingplateStep 4 Fit the tab on the left of the second mounting plate into the anchor slot in the first mountingplate, as shown in Figure 3-34.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-30 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-34 Installing the second mounting plateCAUTIONThe tab on the left of the second mounting plate must be fitted into the anchor slot in themiddle of the first mounting plate.Step 5 Use two screws M6 x 20 to secure the second mounting plate on the first one, as shown in Figure3-35.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-31
Figure 3-35 Securing the second mounting plate on the first one----End Installing the Two RRU3804 ModulesThis describes how to install the two RRU3804 modules on a metal pole. The procedures forinstalling the modules in pole or wall installation mode are the same.PrerequisitelThe RRU3804 mounting plate is installed.lIf the RRU3804 needs to be installed on a metal pole, the PGND cable of the metal pole isconnected.ContextTwo methods can be used to install the mounting plates on the metal pole. Accordingly, you canalso install the two modules by using the following methods. Select a proper method dependingon the installation of the mounting plates.lSide-mounted installationlRear-mounted installation3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-32 Huawei Technologies Proprietary Issue 01 (2007-11-29)
ProcedurelSide-mounted installationCAUTIONTo ensure that the cabling cavities of the modules face outwards, the module on theleft must be installed in reverse mode while the one on the right must be in ordinarymode.1. Remove the plastic housing of the RRU3804 that needs to be installed in reverse mode,as shown in Figure 3-36.Figure 3-36 Removing the plastic housingCAUTIONIf you need to put the plastic housing face down, lay cardboards or packing bagson the ground first to prevent the plastic housing from being scratched.2. Turn the module over, and then fix the housing to the module, as shown in Figure3-37.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-33
Figure 3-37 Installing the module in reverse mode in the housing3. Use two screws M6 x 20 to secure the attachment plate on the module in reverse mode,as shown in Figure 3-38.Figure 3-38 Securing the attachment plate on the module in reverse mode4. Fit the tabs on the attachment plate of the module in reverse mode into the anchor slotsin the front of the second mounting plate, as shown in Figure 3-39.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-34 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-39 Installing the first moduleCAUTIONThe tabs on the attachment plate must be fitted into the outmost pair of anchorslots in the mounting plate.5. Lead two screws M6 x 20 through the holes in the bottom of the module. Then, securethe module on the mounting plate, as shown in Figure 3-40.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-35
Figure 3-40 Securing the first module6. Use two screws M6 x 20 to secure the attachment plate on the other module, as shownin Figure 3-41.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-36 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-41 Securing the attachment plate on the module in ordinary mode7. Fit the tabs on the attachment plate of the module in ordinary mode into the anchorslots in the back of the second mounting plate, as shown in Figure 3-42.Figure 3-42 Installing the second moduleRRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-37
CAUTIONThe tabs on the attachment plate must be fitted into the outmost pair of slots inthe mounting plate.8. Lead two screws M6 x 20 through the holes in the bottom of the module. Then, securethe module on the mounting plate, as shown in Figure 3-43.Figure 3-43 Securing the second modulelRear-mounted installation1. Install the first module by referring to 3.4.1.3 Installing the Single RRU3804Module.2. Perform the same steps to install the second module.NOTETo ensure that the cabling cavities of the modules are on the same side, it is recommended thatthe second module be installed in reverse mode, as shown in Figure 3-44.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-38 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-44 Rear-mounted RRU3804s with the cabling cavities on the same side----End3.4.3 Installing Three RRU3804sThis describes how to install three RRU3804 modules and their mounting plates. The threeRRU3804s can be installed on a metal pole or wall.ProcedureStep 1 Install the mounting plate of the RRU3804. The operation varies with the installation mode.Condition ActionThe RRU3804 needs to be installed on ametal pole.Install the mounting plates of the threeRRU3804s on the metal pole.The RRU3804 needs to be installed on awall.Install the mounting plates of the threeRRU3804s on the wall.Step 2 Install the three RRU3804 modules. For details, refer to 3.4.3.3 Installing the Three RRU3804Modules.----End Installing the Mounting Plates of the Three RRU3804s on the Metal PoleThis describes how to install the mounting plates on the metal pole.PrerequisiteThe metal pole is ready and the pole diameter stays within the range of 60 mm to 114 mm.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-39
ContextWhen installing the three RRU3804 modules on the metal pole, you can use either the side-mounted installation method or the hybrid installation method. Hybrid installation facilitatescapacity expansion of the carriers. Figure 3-45 is the top view of the three modules using theside-mounted installation method.Figure 3-45 Top view of the three modules using the side-mounted installation methodFigure 3-46 is the top view of the three modules using the hybrid installation method.Figure 3-46 Top view of the three modules using the hybrid installation methodNOTEThe following description takes the side-mounted installation method as an example. For description ofthe hybrid installation method, refer to 3.4.1.1 Installing the Mounting Plate of the Single RRU3804 onthe Metal Pole and 3.4.2.1 Installing the Mounting Plates of the Two RRU3804s on the Metal Pole.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-40 Huawei Technologies Proprietary Issue 01 (2007-11-29)
ProcedureStep 1 Install the first mounting plate by referring to 3.4.1.1 Installing the Mounting Plate of theSingle RRU3804 on the Metal Pole.Step 2 Use the holes numbered 2 in Figure 3-47.Figure 3-47 Holes in the multi-purpose attachment plateStep 3 Use two screws M6 x 20 to secure the multi-purpose attachment plate at the bottom of the secondmounting plate, as shown in Figure 3-48.Figure 3-48 Securing the multi-purpose attachment plate at the bottom of the second mountingplateStep 4 Fit the tab on the left of the second mounting plate into the anchor slot in the first mountingplate, as shown in Figure 3-49.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-41
Figure 3-49 Installing the second mounting plateCAUTIONThe tab on the left of the second mounting plate must be fitted into the anchor slot on theleft of the first mounting plate.Step 5 Use two screws M6 x 20 to secure the second mounting plate on the first one, as shown in Figure3-50.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-42 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-50 Securing the second mounting plate on the first oneStep 6 Fit the tab on the right of the third mounting plate into the anchor slot in the first mounting plate,as shown in Figure 3-51.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-43
Figure 3-51 Installing the third mounting plateCAUTIONThe tab on the right of the third mounting plate must be fitted into the anchor slot on theright of the first mounting plate.Step 7 Use two screws M6 x 20 to secure the third mounting plate on the first one, as shown in Figure3-52.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-44 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-52 Securing the third mounting plate on the first one----End Installing the Mounting Plates of the Three RRU3804s on the WallThis describes how to install the mounting plates on the wall.ProcedureStep 1 Install the first mounting plate by referring to 3.4.1.2 Installing the Mounting Plate of theSingle RRU3804 on the Wall.Step 2 Use the holes numbered 2 in Figure 3-53.Figure 3-53 Holes in the multi-purpose attachment plateStep 3 Use two screws M6 x 20 to secure the multi-purpose attachment plate at the bottom of the secondmounting plate, as shown in Figure 3-54.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-45
Figure 3-54 Securing the multi-purpose attachment plate at the bottom of the second mountingplateStep 4 Fit the tab on the left of the second mounting plate into the anchor slot in the first mountingplate, as shown in Figure 3-55.Figure 3-55 Installing the second mounting plateCAUTIONThe tab on the left of the second mounting plate must be fitted into the anchor slot on theleft of the first mounting plate.Step 5 Use two screws M6 x 20 to secure the second mounting plate on the first one, as shown in Figure3-56.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-46 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-56 Securing the second mounting plate on the first oneStep 6 Fit the tab on the right of the third mounting plate into the anchor slot in the first mounting plate,as shown in Figure 3-57.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-47
Figure 3-57 Installing the third mounting plateCAUTIONThe tab on the left of the third mounting plate must be fitted into the anchor slot on the rightof the first mounting plate.Step 7 Use two screws M6 x 20 to secure the third mounting plate on the first one, as shown in Figure3-58.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-48 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-58 Securing the third mounting plate on the first one----End Installing the Three RRU3804 ModulesThis describes how to install the three RRU3804 modules on a metal pole. The procedures forinstalling the modules in pole or wall installation mode are the same.PrerequisitelThe RRU3804 mounting plate is installed.lIf the RRU3804 needs to be installed on a metal pole, the PGND cable of the metal pole isconnected.ContextCAUTIONlInstall the middle module first. Otherwise, the middle module cannot be installed.lTo ensure that the cabling cavities of the modules face outwards, the module on the leftmust be installed in reverse mode while the one on the right must be in ordinary mode.lThe tabs on each attachment plate must be fitted into the outmost pair of anchor slots ineach mounting plate.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-49
ProcedureStep 1 Use two screws M6 x 20 to secure the attachment plate on the first module, as shown in Figure3-59.Figure 3-59 Securing the attachment plate on the first moduleCAUTIONWhen installing the attachment plate, protect the plastic housing from being scratched.lIf you find that the plastic housing is put face down when unpacking the RRU3804,install the attachment plate before taking out the RRU3804.lIf you find that the plastic housing is put face up, lay cardboards or packing bags on theground. Then, take out the RRU3804 and install the attachment plate.Step 2 Fit the tabs on the attachment plate of the module into the anchor slots in the back of the leftmounting plate, as shown in Figure 3-60.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-50 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-60 Installing the first moduleStep 3 Lead two screws M6 x 20 through the holes in the bottom of the module. Then, secure the moduleon the mounting plate, as shown in Figure 3-61.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-51
Figure 3-61 Securing the first moduleStep 4 Remove the plastic housing of the RRU3804 that needs to be installed in reverse mode, as shownin Figure 3-62.Figure 3-62 Removing the plastic housing3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-52 Huawei Technologies Proprietary Issue 01 (2007-11-29)
CAUTIONIf you need to put the plastic housing face down, lay cardboards or packing bags on theground first to prevent the plastic housing from being scratched.Step 5 Turn the module over, and then fix the housing to the module, as shown in Figure 3-63.Figure 3-63 Installing the module in reverse mode in the housingStep 6 Use two screws M6 x 20 to secure the attachment plate on the module in reverse mode, as shownin Figure 3-64.Figure 3-64 Securing the attachment plate on the module in reverse modeStep 7 Fit the tabs on the attachment plate of the module in reverse mode into the anchor slots in thefront of the left mounting plate, as shown in Figure 3-65.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-53
Figure 3-65 Installing the second moduleStep 8 Lead two screws M6 x 20 through the holes in the bottom of the module. Then, secure the moduleon the mounting plate, as shown in Figure 3-66.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-54 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-66 Securing the second moduleStep 9 Use two screws M6 x 20 to secure the attachment plate on the third module, as shown in Figure3-59.Step 10 Fit the tabs on the attachment plate of the module in ordinary mode into the anchor slots in theback of the right mounting plate, as shown in Figure 3-67.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-55
Figure 3-67 Installing the third moduleStep 11 Lead two screws M6 x 20 through the holes in the bottom of the module. Then, secure the moduleon the mounting plate, as shown in Figure 3-68.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-56 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-68 Securing the third module----End3.5 Installing the RRU3804 on the TowerBefore installing the RRU3804 on the tower, you need to assemble the parts and then lift themup to the tower.1. 3.5.1 Assembling the Parts of the RRU3804This describes how to assemble the parts of the RRU3804 before they are lifted up to thetower.2. 3.5.2 Lifting the Assembled RRU3804This describes how to lift the RRU3804 up to the tower after the parts are assembled. Theparts include the mounting plate, RRU3804 module, pole fixture, and plastic housing.3. 3.5.3 Installing the Assembled RRU3804 on the TowerThis describes how to install the assembled RRU3804 on the metal pole after all parts arelifted up to the tower.3.5.1 Assembling the Parts of the RRU3804This describes how to assemble the parts of the RRU3804 before they are lifted up to the tower.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-57
ProcedureStep 1 Use two screws M6 x 20 to secure the attachment plate on the module, as shown in Figure3-69.Figure 3-69 Securing the attachment plateStep 2 Use the holes numbered 1 in Figure 3-70.Figure 3-70 Holes in the multi-purpose attachment plateStep 3 Use three screws M6 x 20 to secure the multi-purpose attachment plate on the mounting plate,as shown in Figure 3-71.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-58 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-71 Securing the multi-purpose attachment plateStep 4 Install a pole fixture on the mounting plate at the lower part of its back by fastening two boltsM10 x 40, as shown in Figure 3-72.Figure 3-72 Installing a pole fixtureStep 5 Align the anchor slots in the mounting plate with the tabs on the attachment plate. Then, assemblethe module and mounting plate, as shown in Figure 3-73.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-59
Figure 3-73 Assembling the module and mounting plateCAUTIONThe tabs on the attachment plate must be fitted into the middle pair of anchor slots in themounting plate.TIPWhen assembling the parts, it is recommended that the module be put up side down. This facilitates theinstallation of the mounting plate.Step 6 Lead two screws M6 x 20 through the holes in the bottom of the module. Then, secure the moduleon the mounting plate, as shown in Figure 3-74.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-60 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-74 Securing the module and mounting plate----End3.5.2 Lifting the Assembled RRU3804This describes how to lift the RRU3804 up to the tower after the parts are assembled. The partsinclude the mounting plate, RRU3804 module, pole fixture, and plastic housing.ProcedureStep 1 Lead the rope through the holes in the mounting plate and then knot the rope, as shown in Figure3-75.Figure 3-75 Assembled RRU3804 tied with the ropeStep 2 Use the same rope to bind another two pole fixtures and parts like bolts, spring washers, and flatwashers.Step 3 Lift all the parts up to the tower.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-61
NOTEIt is recommended that another rope be tied to the assembled RRU3804 to prevent the RRU3804 fromcolliding with the tower.----End3.5.3 Installing the Assembled RRU3804 on the TowerThis describes how to install the assembled RRU3804 on the metal pole after all parts are liftedup to the tower.ProcedureStep 1 Untie the ropes.Step 2 Mount the upper fixture assembly on the metal pole. Ensure that the four ends of the fixtureassembly are on the same plane, as shown in Figure 3-76.Figure 3-76 Mounting the upper fixture assemblyNOTETo facilitate maintenance, it is recommended that the RRU3804 be installed with its front or rear side facingthe tower.Step 3 Use the level bar to check whether the four ends of the fixture assembly are on the same plane.Use the tape measure to check whether the two pole fixtures are parallel.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-62 Huawei Technologies Proprietary Issue 01 (2007-11-29)
NOTEIf the difference between L1 and L2, as shown in Figure 3-77, is beyond ±1 mm, the two pole fixtures arenot parallel.Figure 3-77 Measuring L1 and L2Condition ActionThe pole fixtures are neither horizontal norparallel.Go to Step 2 to adjust the fixture assembly.The pole fixtures are horizontal and parallel. Go to Step 4.Step 4 Install the assembled RRU3804 by fitting the tabs on the mounting plate into the anchor slotsin the pole fixture, as shown in Figure 3-78.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-63
Figure 3-78 Installing the assembled RRU3804Step 5 Use two bolts M10 x 110 to mount the lower fixture assembly on the metal pole, as shown inFigure 3-79.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-64 Huawei Technologies Proprietary Issue 01 (2007-11-29)
Figure 3-79 Mounting the lower fixture assembly----End3.6 Installing the SRXUThis describes how to install the SRXU on the RRU3804 in one-module, two-modulecentralized, or three-module centralized installation mode.3.6.1 Installing the SRXU on a Single RRU3804This describes how to install the SRXU on a single RRU3804 that is mounted on the metal pole.The procedures for installing the SRXU on the RRU3804 in pole or wall installation mode arethe same.3.6.2 Installing the SRXUs on the Two RRU3804sThis describes how to install the SRXUs on the two RRU3804 that are mounted on the metalpole. The procedures for installing the SRXUs on the two RRU3804s in pole or wall installationmode are the same.3.6.3 Installing the SRXUs on the Three RRU3804sThis describes how to install the SRXUs on the three RRU3804 that are mounted on the metalpole. The procedures for installing the SRXUs on the three RRU3804s in pole or wall installationmode are the same.RRU3804User Guide 3 Installing RRU3804 and SRXU HardwareIssue 01 (2007-11-29)  Huawei Technologies Proprietary 3-65
3.6.1 Installing the SRXU on a Single RRU3804This describes how to install the SRXU on a single RRU3804 that is mounted on the metal pole.The procedures for installing the SRXU on the RRU3804 in pole or wall installation mode arethe same.PrerequisiteThe RRU3804 is installed.ContextThe SRXU can be installed on the RRU3804 that is in either ordinary or reverse mode. Figure3-80 shows the SRXU installed on the single RRU3804.Figure 3-80 SRXU installed on the single RRU3804NOTElDetermine the position of the SRXU based on the installation of the RRU3804. If the RRU3804 isinstalled in ordinary mode, install the SRXU on the front side of the RRU3804. If the RRU3804 isinstalled in reverse mode, install the SRXU on the rear side of the RRU3804.lThe procedures for installing the SRXU on the RRU3804 in ordinary and reverse modes are the same.The following description takes installing the SRXU on the RRU3804 in ordinary mode as an example.ProcedureStep 1 Remove the plastic housing of the RRU3804, as shown in Figure 3-81.3 Installing RRU3804 and SRXU HardwareRRU3804User Guide3-66 Huawei Technologies Proprietary Issue 01 (2007-11-29)