Hyundai Electronics Co HWT-210 PCS CDMA WLL Phone User Manual Manual
Hyundai Electronics Industries Co Ltd PCS CDMA WLL Phone Manual
Manual
FCC RF EXPOSURE INFORMATION WARNING! Read this information before using your WLL In August 1996 the Federal Communications Commission (FCC) of the United States with its action in Report and Order FCC 96-326 adopted an updated safety standard for human exposure to radio frequency (RF) electromagnetic energy emitted by FCC regulated transmitters. Those guidelines are consistent with the safety standard previously set by both U.S. and international standards bodies. The design of this phone complies with the FCC guidelines and these international standards. This device was tested for RF exposure compliance with the back of the phone kept 3cm (1.2 inches) from the body. To comply with FCC RF exposure requirements, a minimum separation distance of 3cm (1.2 inches) must be maintained between the user/bystander and the back of the phone, including the antenna. For more information about RF exposure, please visit the FCC website at www.fcc.gov _-., __. ..^.l._- .I_ --- .I Contents -- 1. Before Using ........................................................................... 1.1 .Checking the Package ..................................................... 1.2. Name and Function of Each Part ................................... 1.3. Cautions ......................................................................... 2. Installation .............................................................................. 2.1. General Installation ........................................................ 2.2. Installation of Wall Bracket ........................................... 2.4. Setup for Data Service .................................................. 11 2.4.1 Connection between PC and the WLL terminal.. . 11 3. How to Use ............................................................................ 11 3.1. To Make a Call ............................................................ 11 3.1.1. General ................................................................ 11, 3.1.2. Redial Function .................................................. 12 3.1.3. End of Digit Function .......................................... 12 3.2. To Answer a Call ......................................................... 12 3.2.1.. When the subscriber is in on-hook status .......... .12 3.2.2. When the subscriber is in off-hook status ......... .12 3.3. To Adjust Volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .... 12 3.4. To Adjust Signal Sending Stand-by Time after Dialing .13 3.5. To Adjust Hook Flash Time (Click Time) . . . . . . . . . . . . . . . . . . . .13 3.6. To Use Data Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.6.1 Data Service Receiving mode Setup Function . . . . 13 3.7 To use G3 Fax Service(Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . 131. HWT-2 10 Features 2. Technical Specification . . .. 3) Put Al and A2 parts of the terminal on the screw head and press them down to hold. 4) It will be seen as followings after the installation. Screw required to fix the bracket to the wall. )Bt The backup battery is built-in within the WLL terminal so that it can operate without external power for some time. If the SMPS is removed, the backup battery starts to operate. It can be used about 15 hours in stand-by mode and two hours during the call. -9- _.” .._..- -...- I.. _. . . ” .- .,. 1. Features General Local Tone Hook Flash Operation User Control 2. Tech&al Specifrca’tion Air Interface Connection with normal telephone Line interface capability : 2 wire 3 LED (Power, Battery, Service) Wall Mountable - Dial tone - Busy tone - Warning Tone - Last Number Rediai - End of Digit - Received Volume Control : Sstep - Dial Time Control : 4s - 8s - Hook Flash Time(Click Time) Control - Common air interface standard: J-STD-008 - Frequency: TX: 1850 - 1910MHx RX: 1930 - 199oMHx - TX Output Power: 316mW(25dBm) Battery Back-up - I Connectors for Various Service Support Physical Environinental Power Supply 4ccessories - 16 - - RX Sensitivity: - 104dBm - Vocoder: 8K/13K QCELP 8K EVRC - Channel Bandwidth: CDMA 1.25Mhx - Spurious: TX Freq. Band: -61dBm below : RX Freq. Band: -81dBm below - MOD/DEMOD: OQPSK/QPSK - Frequency Accuracy: Fo+/-150Hz - Type: Ni-Cd - Capacity: 8.4@1.7A - Talk Time: 2 Hours i ,. ‘. * ’ . k - Standby.Time: 20 Hours - RJ-11: standard wire-line telephone : Analog G3 Fax (Optional) - Serial port : Maintenance Purpose : Data Service Purpose ( Internet, .PC Fax) - Dimension (DxWxH) : 226xl66x65mm - Weight (including Backup battery): 995g - Operating temperature: -1OOC -‘+50°C - Input Power :llOV-24OV(fzO)AC, 50/6OHx - Output Power: DC lZV@2A - Power Supply
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Modify Date : 2000:04:03 09:59:44 Creator : Acrobat 3.0 Capture Plug-in Producer : Acrobat 3.0 Scan Plug-in Create Date : 2000:02:14 10:50:21 Page Count : 16EXIF Metadata provided by EXIF.tools