Hyundai IBT W15L00001 Intel RISC - 206MHz CPU w/ 15" LCD Client Monitor User Manual
Hyundai IBT Corp. Intel RISC - 206MHz CPU w/ 15" LCD Client Monitor Users Manual
Users Manual
W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ1 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ2 U.S.A. U.S.FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT INFORMATION TO THE USER NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet of a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for assistance. Changes or modification not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Connecting of peripherals requires the use of grounded shielded signal cables. W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ3 DDEECCLLAARRATION ATION OF OF CONFORMITY CONFORMITY WE ImageQuest CO., LTD. Ami-ri Bubal-Eub Ichon-Si Kyungki-Do 467-860 KOREA declare under our sole responsibility that the product: Kind of equipment Type-Designation COLOR LCD CLIENT W15L00001 to which this declaration relates is in conformity with the following standard(s) or other normative document(s) Safety : EN 60950 : 1992 + A1, A2, A3, A4, A11 EMC : EN 55022 / 1998, EN 55024 : 1998 EN 61000-3-2 : 1995+A1 : 1998+A2 : 1998 EN 61000-3-3 : 1995 following the provisions of the Low Voltage Directive 73/23/EEC, 93/68/EEC and the EMC Directive 89/336/EEC. Accredited testlaboratory: TÜV Rheinland Am Grauen Stein 51105 Köln KOREA /Oct. 31, 2001 HONG KI, KIM (Place and date of issue) (Name and signature of authorized person) W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ4 Contents 1. Introduction of W150 ......................1 OverView ...............................................1 Function ................................................1 Feature ..................................................1 2. Before the Operation ......................3 System structure ....................................3 Front of W150 .............................................3 Hot Keys .................................................4 Rear of W150 ..............................................4 System Connection ................................6 Connection of External Device .............6 3. Operation of W150 ..........................7 Setup of Operating Environment .........7 Menu window Composition .....................7 Setup of Network ......................................7 Setup of Preference ...................................9 Setup Keyboard Feature ..........................10 Setup of Display Feature .........................10 System Properties ....................................11 Volume & sound Properties .....................11 Network Environment View ...............12 Ping ..........................................................12 Ipconfig .....................................................12 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ5 Terminal Connection Manager ...........13 New connection Creation .......................13 Additional Creation of ICA Connection ...14 Additional Creation of RDP Connection ...17 Connection Editing and Deletion ...........19 Editing of ICA Connection ..........................19 Editing of RDP Connection .........................19 Connection Deletion ..................................20 Start-up Connection Setup .....................20 Server Connection ...................................21 Using of W150 Hot Keys .........................21 W150 Hot Keys .............................................21 Multi Connection start ................................21 Client Setting and Save ..........................22 Client Setting ................................................22 Save ................................................................23 Ending the Operation .............................23 Disconnecting ...............................................23 Terminal Ends ...............................................23 4. Troubleshooting ........................24 5. System Specification .................25 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ1 1. Introduction of W150 Overview “Easy installation, Optimized function, The least expenses”. It is this web terminal’s strong points that you can expect when you utilize it in your environments. Under the basic environments of server based on computing and internet connection speed of 56kbps, you can use various applications on the high performance servers based on Windows 2000 Server OS as well as internet connection. Classification Operation Mode CPU SDRAM FLASH Operating System W150 WBT Intel Strong ARM 206Mhz 16M 8M Windows CE 3.0 Function All the application programs are operated through the server, not in itself W150. W150 as a client transfers to the server only the inputs of mouse and keyboard. The result of application programs executed in the server are transferred to the client with the use of Protocol ( RDP or ICA ). Accordingly, traffic size that causes problems in the existing network is reduced considerably and no sophisticated is required for client. Features As Operation system, “Windows CE” is utilized W150 has an open type architecture. It is run with a 32 bit multitasking and multithread operating system that supports various types of device. °§ Utilize a kernel based on the architecture of WINDOWS NT. °§ Support pre-occupied multi tasking and multi thread. W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ2 °§ Provides a user friendly GUI environment °§ Booting process is not necessary since the operating system is stored on ROM. Strong ARM CPU as of Intel °§ Low powered (4W) operation is available. °§ Size and Weight are reduced °§ Low noise ( no cooling fan is required ) Quick Booting Circuit Design (Compared to the general PC) During the Power On, system booting is performed in the last task environment. A/S Cost Reduced Since there are no fixture elements such as HDD, FDD, CD-ROM, and cooing fan that are main causes of trouble, only minimum A/S is required. Can be operated in the server environment The program is executed in the server and only the results of execution (screen value) are displayed on the client. Multi-user who are connecting to the server at the same time can execute own program independently. Application Server Basic duty Server Headquater LAN ERP Server ASP Server EC Web Hosting Server (ISP DATA Center) Branch office LAN WBT Clients WBT - Win CE Application Server - Windows 2000 - Meta Frame W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ3 2. Before the operation In the section, the structure and setup method of W150 is described. System Structure You should be familiar with the system structure for the proper connection of peripheral devices. Basic parts supplied include a mount ( Main body ), keyboard, mouse, adaptor, and AC power cord. °‹ Front Side of W150 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ4 Hot Keys Power If you put briefly this button for screen on/off. The system is reset if you put the button for 3 seconds or longer. Web If you put this button, with the server connected state, Internet Explore Window of server is displayed. E-mail If you put this button, with the server connected state, Outlook Express of Window server is displayed. Bright This is used to adjust the brightness of the screen. Press “°„ “ to brighten the screen, and press “°Â “ to darken it. °‹ Rear of W150 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ5 ICON NAME Functions Description This is a typical aerial bus. An external device that supports USB is faster than a serial port and easy to connect. Since USB supports the data transmission rate of 12Mbps, any types of peripheral devices can USB be connected without worrying about the operation (Optional) speed. In addition, it can accommodate up to 127 devices. Moreover, connection can be made during the PC operation as well. No power of peripheral devices is required. RS-232C This is connected to D-type connector that consist of 9 pins and interfaces with other serial device for (Optional) transmitting/receiving data Mouse Keyboard Phone PS/2 Port, connected to MINI-DIN connector made up of 6 pins. Input jack for speaker MIC Input jack for microphone LAN Single line for digital transmission This interface is connected to a RJ-45 Jack made up of 8 pins Power This is connected to an adapter that supplies power to the system W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ6 System Connection In the proceeding section, the system connection order and method are described. The power should be off during the system connection. Connecting Keyboard Connect the keyboard to its port after checking whether the port is PS/2. Connecting Mouse Connect the mouse to its port after checking whether the port is PS/2. Connecting LAN Connect the RJ-45 jack to the LAN port. Connecting Adapter Connect the adapter to the POWER port and outlet. Connecting Speaker and Microphone Connect the speaker or earphone to Phone port and the microphone to the MIC port. Connection of External Device W150 has RS 232-C port and USB port for accommodating additional external device. Serial Port Serial port can be connected to an external modem or other device that support serial Device. USB Port USB Port can be connected to a peripheral that support USB. W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ7 3. Operation of W150 Setup of Operating Environment In this section, the operation of W150 under the server setup environment is described. For more details, ask your server manager. ßè Menu window Composition You should go through the following steps in order to set up W150 Properties. Menu window is displayed if you click right button of mouse from the desktop screen Menu window is composed following. Preference OS & Memory System Setting ¢∫ Display Client Setting Network Test ¢∫ Save ShutDown < Menu window > Ping Input IPconfig Mouse < Network Test > Network Sound < System Setting > ßè Setup of Network 1. You can click “System setting“ °Ê “Network“ from Menu window. W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ8 2. Click “property“ of Adaptor tap. 3. Select one of the following options from the “IP Address“ tab °§ If the network uses Dynamic Host Configuration Protocol (DHCP), click the above “Obtain an IP Address via DHCP“. °§ If you want to use Static IP information allocated to you, click the below “Specify an IP Address“ and then, enter IP Address, Subnet Mask, and Gateway. 4. If the network requires DNS or WINS setup, you can select “Name Servers“ tab and then, enter DNS or WINS information. 5. You can click “OK“ in order to finish. 6. Select “save“ from Menu window to save setup. 7. Select “shutdown“ from Menu window to apply setup. W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ9 8. You can check “Restart system“ and click “OK“. Then, W150 is re-booted. ßè Setup of Preference Click “Preference“ from Menu window to display Terminal Preference window. Terminal Preference has the following two tabs. Manufacture : It shows factory-default settings and operating system version information. Preference : It enables you to set the name and information of this terminal, type of keyboard and screen saver function. If you select the bottom option, the terminal environment will be reset to factory-default settings. W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ10 ßè Setup of Keyboard Features Keyboard features are changed based on you requirements and the type of board keyboard used. Repeat delay : Keyboard characters are displayed repeatedly. ( Ex : time passed until the next character is recognized during the key pressing.) Repeat Rate : The rate in which characters are repeated by the keyboard. You should go through the following steps in order to change keyboard features. 1. Click “System Setting“ °Ê “Input“ from Menu Window. 2. Use the mouse to drag Repeat delay Slider toward left or right in order to change Repeat delay. 3. Use the mouse to drag Repeat rate Slider toward left or right in order to change Repeat rate. 4. Then, click “OK“ ßè Setup of Display Features Adjust of colors and Brightness rate You should go through the following steps in order to change display settings. 1. Click “System Setting“ °Ê “Display“ from Menu window. 10 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ11 2. Select the desired colors & Adjust brightness. 3. Click “OK“. ßè System Properties You can click “System Setting“ °Ê “OS & Memory“ from Menu window. You can display system information by clicking General. You can display a window for managing system memory by clicking Memory. ßè Volume & Sound Properties You can click “System Setting“ °Ê “Sound“ from Menu window. You can drag the audio slider bar on either side of it for volume adjustment. 11 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ12 Network Environment View ßè Ping Click “Network Test“ °Ê “Ping“ from Menu window to open “Ping“ window. You can check the connection condition when typing the opposite side IP or name on the “Destination Hostname or IP“ section and pressing the “Start“. ßè Ipconfig Click “Network Test“ °Ê “Ipconfig“ from Menu window to open “Ipconfig“ window. When clicking the “Ipconfig“ button, the information of the operating network will appear. 12 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ13 Terminal Connection Manager This is used when connecting the network of W150. In case you fail to setup Initial Start or Automatic Start Connection, Terminal Connection Manager is displayed automatically during the start and end of W150. The Host (Server) and Client (Terminal) are recognized based on the connection state. You can create, edit, and delete network connection Terminal Connection Manager window. ßè New Connection Creation 1. Click “Add“ in Terminal Connection Manager Window in order to display New Connection window. 2. Select one of the following two connection protocols. °§ Citrix Independent Computing Architecture Protocol ( ICA ) °§ Microsoft Remote Desktop Client Protocol ( RDP ) 3. Then, click “OK“. Click “Cancel“ to return to the previous window. 13 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ14 °‹ Additional Creation of ICA Connection 1. Select Citrix ICA Client of New Connection window in order to display the Specify Connection Type Window. 2. Specify connection type. °§ Network connection : Direction connection line is required as in the case of °§ Network Connection 10/100Base-T Dial-in connection : modem is used. 3. Then, click “Next“. 4. All available Citrix server or application on the servers will be inquired and recognized. Select the required servers or application. If the server list doesn’t appear, search it again using “Refresh“ or type the server name or IP to connect directly. 5. Then, click “Next “. If you select “Finish“, following option will be saved without specification. 6. The Connection Name of Terminal Connection Manager can be changed on the following window. 14 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ15 7. Then, click “Next“. 8. Configuration can be made in such a way that same applications can be used from the selected server. You can leave it blank in order to specify Command Line and Working Directory or to use windows NT Desktop. 9. Then, click “Next“. 10. Specify Username, Password, and Domain in order to logon to the server automatically. 11. Then, click “Next“. 12. Select Window Colors desired on Select Window Option Window. 15 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ16 13. Click “Next“. 14. You can configure the ICA session. °§ Compress Data Stream - select this when connection is made with modem (modem dial-up) or WAN(Wide Area Network). °§ Enable Sound - select this if you use 10/100Base T as LAN (Local Area Network). When using Sound through WAN and modem, increasing usage of bandwidth causes some problems. °§ If you use modem or WAN, set “Sound Quality“ to LOW and “SpeedScreen“ to ON. 15. Click “Next“. Then, Firewall Settings window is displayed. 16. You can enter Firewall information in Firewall Settings window if the network requires Firewall setup. Then, click “Finish“. 17. Since the installation of ICA connection is over, connection the server is ready. 16 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ17 °‹ Additional Creation of RDP Connection 1. Select Microsoft Remote Desktop of New Connection window. Then, Windows Terminal Server (WTS) Connection Wizard Window is displayed. 2. Enter a name for new connection to the name area. 3. Enter the name of IP address of server to be connected to the server area. 4. Check Low Speed Connection when connection to the server is made through low Bandwidth lines such as WAN of serial line. 5. Then, click “Next“. 6. When desiring to logon automatically to the server, you should select automatic logon and then, specify Username, Password, and Domain. 7. Then, click “Next“. 17 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ18 8. The application that is selected instead of desktop can be configured. You can select Application File Name and specify Command Line and Working Directory. Or you can leave it blank in order to use Windows NT desktop. 9. Then, click “Next“. 10. Then, click “Finish“. You are now ready to connect to the server since the installation of WTS Connection Wizard has been completed. 18 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ19 ßè Connection Editing and Deletion °‹ Editing of ICA Connection ICA Connection editing is performed through the following steps. 1. Select ICA Connection to be edited from the Connection Name List of Terminal Connection Window. 2. Click “Edit “. Then, the Edit Connection Details window is displayed. 3. You can modify the information on each tap. Refer to the “Additional Creation of ICA Connection“ for the related tap information. ßí Editing of RDP Connection 1. Select RDP Connection to be edited from the Connection Name List of Terminal Connection Window. 2. Click “Edit“. Then, the Edit Connection Details window is displayed. 19 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ20 3. The Edit Connection Window has the following two taps. °§ Net Connections : Used to edit connection or logon automatically. °§ Application : Used to go automatically to the file name or working directory path whenever starting the session. 4. Change the Parts requires to be changed Net Connection or Application Area. 5. Then, click “OK“ after the completion. °‹ Connection Deletion 1. Select Connection Name of Terminal Connection Manager Window. 2. Then, click “Delete“. 3. Click “Yes“ for confirmation. ßè Startup-up Connection setup Automatic connection to the server is possible every time the session is started. 1. Select a Connection from the Connection Name List of Terminal Connection Manager Window and Click “Startup“. Then, the Connection Startup Window is displayed. 2. Select the following Startup option Make the selection your default connection Connection selected from Terminal Connection Manager is used as default. This default connection is highlighted when W150 power on and Terminal Connection Manager Screen is displayed. Automatically start the selected connection at startup Every time you use W150, the system is started up automatically with the selected connection 3. Then, click “OK“. 20 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ21 ßè Server Connection Terminal Connection Manager lists all the network connections available for use. You Should go through the following steps in order to connect to the server. 1. Select a Connection Name on the list. 2. Click “Connection“ or double click “Connection Name“. If the connection has been defined as automatic logon, W150 is connected and you are logged on automatically. 3. In case the logon is not automatic, Window Logon Information Window is displayed. Enter logon with the prompt. ßè Using of W150 Hot Keys Hot keys are used to simplify the switching process between active sessions. By using hot keys instead of Terminal Connection Manager, you can switch automatically each program through simple key manipulation. In the below, several W150 hot keys are specified as below. < W150 Hot Keys > Hot Key Function CTRL+ALT+up arrow Changes to Up between active sessions CTRL+ALT+Down arrow Changes to Down between active sessions CTRL+ALT+Home Changes automatically to default sessions CTRL+ALT+END The screen is changed to directly to W150 Connection ManagerThe screen is changed to Terminal Preference Screen in case Connection Manager is run. If the hot keys are not working, see the instruction of Multi Connection Start. < Multi Connection start > W150 can perform multi connections at the same time. The number of connection is connections is limited by the RAM capacity. 1. Press CTRL+ALT+END to access to W150 Connection Manager. 2. Select Connection Name and then, click “Connect“. 21 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ22 You should go through the following steps in order to change the connection. 1. Press CTRL+ALT+END to access to W150 Connection Manager. 2. Select Connection Name and then, click “Connect“. 3. Or press CTRL+ALT+UP or CTRL+ALT+DOWN in order to change the connection. Client Setting and Save ßè Client Setting Click “Client setting“ from Menu window to open “Client Setting“ window. 1. ICA Setting Press “Global Setting“ button in order to change various settings on the window. 2. RDP Setting You can select RDP Encryption Enable option. 22 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ23 ßè Save You can press “Save“ from Menu window, and then, The information that users have changed is saved on the FLASH ROM, so it cannot disappear if the power is gone off. Ending the Operation ßè Disconnecting Click the “System exit“ in its Windows Start menu. “Logoff“ or “Disconnect“ will be displayed. “Logoff“ closes all application programs and “Disconnect“ leaves application programs operating and just disconnects from the server. If you end the system using “Disconnect“, the same environment as before will be configured when connecting the same account. ßè Power on/off of W150 In case you do not use W150, you can turn the power off just by pressing the “power” button on the front cover of W150. Then, it consumes a little power. And if you will not use W150 for a long time, please disconnect the adapter cord from the power connecting jack in the rear cover of product or power cable from the wall outlet. 23 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ24 4. Troubleshooting The followings provide some solutions to common problems when using setting up your terminal The monitor screen is blank. Check whether the power cord has been inserted properly into the terminal Check whether the monitor is properly plugged into an AC outlet. Check whether the Terminal is OFF. Check whether the system is on suspend mode. The mouse does not work. Check whether the mouse jack insert properly into the mouse port. Check whether the mouse ball is operated freely. The Keyboard does not respond. Check whether the keyboard has been connected properly to the keyboard port Check whether power is being supplied properly to W150. The Network connection does not work Check whether the cables are connected properly to the LAN port. Verify the network settings. Check whether the network address is valid. Verify the configuration of the server terminal. 24 W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ25 5. System Specification The specification of W150 is specified as below : ßè Hardware specification Intel Strong ARM 32bit CPU RISC Processor 206 MHz Flash memory 8MB FLASH RAM memory 16MB SDRAM Audio 16-bit Stereo Vided 1024 x 768 16bit True Colors ßè Communication and Input/Output Specification Networking Protocol Communication protocol Serial Port USB Port Audio Port Keyboard and Mouse Port Power 25 Ethernet 10 Base T TCP/IP with DNS, DHCP, and PPP Microsoft RDP Ctrix ICA 1 x DB-9 RS232C Serial Port 2 x USB Port Earphone Jack Microphone In Keyboard and Mouse Port (PS/2 Keyboard and Mouse included) 12V DC In W150-ENG-1µµ¿¤æ˜ 2001.11.1 1:28 AM ∆‰¿Ã¡ˆ26 26
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2001:11:01 01:28:12Z Subject : Modify Date : 2001:10:31 10:40:02-05:00 Page Count : 31 Creation Date : 2001:11:01 01:28:12Z Author : 9500 Producer : Acrobat PDFWriter 3.0.1 for Power Macintosh Keywords : Mod Date : 2001:10:31 10:40:02-05:00 Metadata Date : 2001:10:31 10:40:02-05:00 Title : Creator : 9500 Description :EXIF Metadata provided by EXIF.tools