IDT Technology THGN132N-01 Thermo-Hygrometer Remote Sensor (433.92MHz Tx) User Manual MODEL RA313PA
IDT Technology Limited Thermo-Hygrometer Remote Sensor (433.92MHz Tx) MODEL RA313PA
Contents
- 1. User Manual
- 2. Users Manual
User Manual
temperatures may affect battery performance and signal transmission. THGN132N FIG. 1 TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. CHANGING CHANNELS To change channels once channel has been assigned: Remove battery and repeat above procedure. RESET Customer Care department directly, please visit: www2.oregonscientific.com/service/support OR Call 1-800-853-8883. For international inquiries, please visit: www2.oregonscientific.com/about/international INDUSTRY CANADA STATEMENT Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. IC number: 3277A-THGN132N Press RESET to return to the default settings. EU-DECLARATION OF CONFORMITY TROUBLE SHOOTING FIG. 2 PROBLEM Remote sensor SYMPTOM Abnormal / strange readings Cannot locate remote sensor Cannot change channel Data does not match main unit EN Remote Thermo-Hygro Sensor Model: THGN132N USER MANUAL OVERVIEW FRONT VIEW (FIG 1) 1. LED status indicator: blinks when transmitting a reading. BACK VIEW (FIG 2) 1. 2. 3. 4. 5. Wall mount hole Battery compartment RESET: Reset unit to default settings Channel Switch Table stand COMPATIBLE UNITS The THGN132N is compatible with a variety of multi-channel units. NOTE If unsure about the compatibility, please consult your dealer. GETTING STARTED SENSOR SET UP 1. Slide open the battery door. 2. Insert the battery, matching the polarities (+ / -). See FIG 2. 3. Press RESET after each battery change. NOTE Install battery in the remote sensor before the main unit. 4. Slide channel switch to select a channel (1, 2, 3). Ensure you use a different channel for each sensor. 5. Press RESET. 6. Close the battery door. 7. Initiate a sensor search on the main unit to start receiving temperature / humidity data from the sensor. PRECAUTIONS x Do not subject the unit to excessive force, shock, dust, temperature or humidity x Do not cover the ventilation holes with any items such s newspapers, curtains etc. x Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. x Do not clean the unit with abrasive or corrosive materials. x Do not tamper with the unit ’s internal components. This invalidates the warranty. x Only use fresh batteries. Do not mix new and old batteries. x Images shown in this manual may differ from the actual display. x When disposing of this product, ensure it is collected separately for special treatment. x Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information. x The contents of this manual may not be reproduced without the permission of the manufacturer. x Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. x Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use. NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice. SPECIFICATIONS TYPE REMOTE UNIT LxWxH Weight Temperature range 8. Secure the sensor in the desired location using the wall mount or table stand. For best results: x Place the sensor within 30 m (100 ft) of the main unit. x Place the sensor out of direct sunlight and moisture. x Position the sensor so that it faces the main (indoor) unit, minimizing obstructions such as doors, walls and furniture. x Place the sensor in a location with a clear view to the sky, away from metallic / electronic objects. x Position the sensor close to the main unit during cold winter months as below-freezing REMEDY Press RESET Check battery Check location Check sensors. Only one sensor is working Initiate a manual sensor search Resolution Humidity range Humidity resolution Signal frequency Transmission range No. of channels Signal transmission Channel 1 Channel 2 Channel 3 Power DESCRIPTION 117 x 80 x 171 mm (4.78 x 3.27 x 6.98 in) 241 g (8.5 oz) without battery -20°C to 60°C (-4°F to 140°F) 0.1°C (0.2°F) 25% - 95% 1% 433 MHz 30 m (98 ft) unobstructed Every 39 seconds Every 41 seconds Every 43 seconds 1 x UM-3 (AA) 1.5 V batteries ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you're in the US and would like to contact our Hereby, Oregon Scientific, declares that this Wireless Weather Station (model: THGN132N) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service. FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: x Reorient or relocate the receiving antenna. x Increase the separation between the equipment and receiver. x Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. x Consult the dealer or an experienced radio / TV technician for help. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com), or on the warranty card for this product) for all inquiries instead. We Name: Address: Oregon Scientific, Inc. th 19861 SW 95 Ave.,Tualatin, Oregon 97062 USA Telephone No.: 1-800-853-8883 declare that the product Product No.: THGN132N Product Name: Remote Thermo-Hygro Sensor Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Company : Integrated Display Technology Source Modified : D:20070801104049 Create Date : 2007:09:10 10:08:40+08:00 Modify Date : 2007:09:10 10:08:40+08:00 Metadata Date : 2007:09:10 10:07:40+08:00 Creator Tool : PScript5.dll Version 5.2 Document ID : uuid:0EA0369C425FDC119DD996CEEE69744F Instance ID : uuid:e4d1e581-51f8-41c6-9a47-31159e3b85d5 Derived From Instance ID : uuid:9e3bf69e-06ab-47c3-8656-400ad3b4546e Derived From Document ID : uuid:97c82c2c-1f48-41b5-879a-20c902d04665 Derived From Version ID : Format : application/postscript Title : MODEL : RA313PA Creator : Isadora Wagner Subject : Headline : Page Count : 1 Author : Isadora WagnerEXIF Metadata provided by EXIF.tools