User manual
INID ISO14443 readers Cable specifications (non-shielded) interface Wiegand Clock/Data TTL serial RS232 RS485/RS422 (cable power) RS485/RS422 (local power) CAN bus maximum cable length meters feet 61 200 91 300 152 500 25 80 1.5 2.4 61 200 152 500 1220 4000 min.conductor size with 12 V supply2) mm2 AWG 0.25 24 0.34 22 0.25 24 0.34 22 0.25 24 system / speed dependent 2) With a 24V supply, minimum conductor size is AWG 24 for all interfaces and lengths. Specifications Typical read range Model INID ISO14443 AC INID ISO14443 Mifare ISO card 60 mm 2.4 inch 30 mm 1.2 inch Power Supply 7 - 24 Volt DC (12 VDC recommended) Power consumption model INID ISO14443 AC INID ISO14443 AC PIN INID ISO14443 INID ISO14443 PIN average 1300 mW 1300 mW 500 mW 500 mW Current consumption @12 VDC1) model average INID ISO14443 AC 110 mA INID ISO14443 AC PIN 110 mA INID ISO14443 42 mA INID ISO14443 PIN 42 mA 1) peak 1750 mW 2050 mW 950 mW 1250 mW peak 146 mA 171 mA 79 mA 105 mA Use Ohm's law to calculate current at different voltages. Interface Inputs type and protection specifics Outputs type and protection specifics Dimensions 143 x 50 x 25 mm / 5.63 x 2 x 1 inch Material UL94-V0 rated LEXAN® 925U Operating temperature -25° to 65° C / -15° to 150° F Protection class IP54 Complete protection against contact, protection against dust deposit. Protection from splashed water. Features INID readers have a slim mullion mountable design and are designed for both in- and outdoor use. The INID reader can be mounted on any surface without significant performance degradation. For mounting to a metal surface however, a non-metallic spacer is advised. The switch mode power supply of the reader accepts a wide range input from 7 - 24 VDC. Higher input voltages result in lower current consumption and allow for cost effective wiring with a smaller conductor diameter. Reader output formats are determined by the personalization of the card and/or configuration of the reader. Separate models are available for card-only and card+PIN; for Access Control with a larger read range and low power with a smaller read range. Electrical interface options for WG/C&D/TTL serial, RS485/RS422, RS232 and CAN bus are available with separate models. PIN code INID PIN readers provide extensive options for PIN data formats and output protocols. The card and PIN code data is sent separately and independently allowing host system determined operation for cardonly, PIN-only and card and PIN usage. Indications User feedback is provided by a single LED bar and a multi-tone sounder. User feedback is controllable by the host system. PIN models are equipped with back lighting of the PIN code digits for usage in dark environments. Operation When a proximity card is read successfully the card associated code is send to the Host system, the LED bar lights briefly and the sounder sounds a short tone. When a PIN is entered the data is transmitted; at each key press a click sound is produced and the LED bar lights briefly. The back light of the PIN code lights up after a successful card read or at the first key press. The LED bar or individual LED bar segments and the buzzer are also controllable by the Host system. INID ISO14443 readers - installation and operation manual version 1.06; February 2nd, 2011 Connector Assignments Wiegand / Clock and Data / TTL serial 500-5000 500-5040 500-5100 500-5140 INID ISO14443 AC reader WG/C&D/TTL INID ISO14443 AC PIN reader WG/C&D/TTL INID ISO14443 reader WG/C&D/TTL INID ISO14443 PIN reader WG/C&D/TTL LED 1 - Green LED 2 - Amber D1 DATA TXD D0 CLOCK TXE BUZZER TAMPER GND POWER RXD RS485 / RS422 500-5010 500-5050 500-5110 500-5150 INID ISO14443 AC reader RS485/RS422 INID ISO14443 AC PIN reader RS485/RS422 INID ISO14443 reader RS485/RS422 INID ISO14443 PIN reader RS485/RS422 LED 1 - Green LED 2 - Amber RS485 TRX+ RS422 TX+ RS485 TRX- RS422 TX- RS485 n.c. RS422 RXRS485 n.c. RS422 RX+ GND POWER Caution: floating communication lines may cause spurious emissions. Ensure all communication lines are properly biased and terminated. RS232 500-5020 500-5060 500-5120 500-5160 INID ISO14443 AC reader RS232 INID ISO14443 AC PIN reader RS232 INID ISO14443 reader RS232 INID ISO14443 PIN reader RS232 LED 1 - Green LED 2 - Amber CTS TXD RTS RXD GND POWER CAN bus 500-5030 500-5070 500-5130 500-5170 INID ISO14443 AC reader CAN bus INID ISO14443 AC PIN reader CAN bus INID ISO14443 reader CAN bus INID ISO14443 PIN reader CAN bus LED 1 - Green LED 2 - Amber CANL CANH n.c. n.c. GND POWER Parts list Reader front Terminal connector Mounting backplate Enclosure screw Installation sheet qty: 1 qty: 1 qty: 1 qty: 1 qty: 1 Installation instructions 1 Determine an appropriate position for the reader and drill two holes for mounting the backplate and one hole for the cable, see diagram for measurements. Do not mount readers less than 20 cm (8 inches) apart. 2 Pull the cable trough the hole in the backplate and mount the backplate. Protect the cable against sharp edges and any damage from chafing. 3 Remove the terminal connector from the front of the reader. Prepare the end of the cable and wires, eliminate any loose or frayed strands. Keep the wire ends as short as practical. 4 Connect the wires to the connector according to the reader type. Wire ends, termination resistor leads and optional permanent links shall be kept as short as possible. 5 Place the connector on the reader pins. 6 Place the reader front over the hinge of the backplate and close the reader (see diagram), keeping the wiring in the lower part of the reader housing. DO NOT use excessive force, retract the cable if necessary. For mounting, use only flat head screws with a maximum shank size of 4 mm (5/32”, #7) 7 Test the reader: apply power and present a valid card. The LED bar should flash and the sounder should produce a short tone indicating a successful read. If the Host system is connected to LED bar and sounder inputs these should follow the functionality of the Host system. 8 The reader front should now be secured to the backplate using the supplied enclosure screw. Certifications CE, FCC FCC ID: YAB-ISOACRDR YAB-ISORDR (model 50XX) (model 51XX) Compliance statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This in particular is applicable for the antenna which has been delivered with the reader. Consult your National Authority if any authorization is needed for this product. INID BV Kollenbergweg 78c 1101AV Amsterdam Zuidoost The Netherlands Phone: +31 (0)20 6967 441 Web: www.inid-readers.com INID ISO14443 readers - installation and operation manual version 1.06; February 2nd, 2011
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 Language : en-US Tagged PDF : Yes Part : 1 Conformance : A Title : mdoc091201 Creator : Mark Olde Producer : OpenOffice.org 3.2 Creator Tool : Writer Create Date : 2011:02:02 15:04:06+01:00 Author : Mark OldeEXIF Metadata provided by EXIF.tools