INID MultiSmart readers
Cable specifications (non-shielded)
interface
Wiegand
Clock/Data
TTL serial
RS232
RS485/RS422
(cable power)
RS485/RS422
(local power)
CAN bus
maximum
cable length
meters
feet
61
200
91
300
152
500
25
80
1.5
2.4
61
200
152
500
1220
4000
min.conductor size
with 12 V supply2)
mm2
AWG
0.25
24
0.34
22
0.25
24
0.34
22
0.25
24
system / speed dependent
2)
With a 24V supply, minimum conductor size is AWG 24 for all
interfaces and lengths.
Features
INID readers have a slim mullion mountable design
and are designed for both in- and outdoor use. The
INID reader can be mounted on any surface without
significant performance degradation. For mounting
to a metal surface however, a non-metallic spacer is
advised.
The switch mode power supply of the reader
Specifications
accepts a wide range input from 7 - 24 VDC. Higher
input voltages result in lower current consumption
Typical read range
and allow for cost effective wiring with a smaller
Technology
distance
conductor diameter.
Mifare ISO card1)
60 mm
2.4 inch
LF Proximity ISO card2)
30 – 60 mm 1.2 – 2.4 inch Reader output formats are determined by the
1)
Depends on transponder antenna geometry.
personalization of the card and/or configuration of
1)
Depends on LF technology and card antenna geometry.
the reader.
Separate models are available for card-only and
Power Supply
card+PIN.
7 - 24 Volt DC (12 VDC recommended)
Electrical interface options for WG/C&D/TTL serial,
RS485/RS422, RS232 and CAN bus are available
Power consumption
with separate models.
model
average
peak
INID MultiSmart
1300 mW
1750 mW
PIN code
INID MultiSmart PIN
1300 mW
2050 mW
INID PIN readers provide extensive options for PIN
data formats and output protocols. The card and
Current consumption @12 VDC3)
model
average
peak
PIN code data is sent separately and independently
INID MultiSmart
110 mA
146 mA
allowing host system determined operation for cardINID MultiSmart PIN
110 mA
171 mA
only, PIN-only and card and PIN usage.
3)
Use Ohm's law to calculate current at different voltages.
Interface
Inputs type and protection specifics
Outputs type and protection specifics
Dimensions
143 x 50 x 25 mm / 5.63 x 2 x 1 inch
Material
UL94-V0 rated LEXAN® 925U
Operating temperature
-25° to 65° C / -15° to 150° F
Protection class
IP54 Complete protection against contact,
protection against dust deposit. Protection
from splashed water.
Indications
User feedback is provided by a single LED bar and a
multi-tone sounder. User feedback is controllable by
the host system. PIN models are equipped with
back lighting of the PIN code digits for usage in
dark environments.
Operation
When a proximity card is read successfully the card
associated code is send to the Host system, the LED
bar lights briefly and the sounder sounds a short
tone.
When a PIN is entered the data is transmitted; at
each key press a click sound is produced and the
LED bar lights briefly. The back light of the PIN code
lights up after a successful card read or at the first
key press.
The LED bar or individual LED bar segments and the
buzzer are also controllable by the Host system.
INID MultiSmart readers - installation and operation manual version 1.02; March 16, 2012
Connector Assignments
Wiegand / Clock and Data / TTL serial
500-5005 INID MultiSmart reader WG/C&D/TTL
500-5045 INID MultiSmart PIN reader WG/C&D/TTL
LED 1 - Green
LED 2 - Amber
D1 DATA
TXD
D0 CLOCK TXE
BUZZER
TAMPER
GND
POWER
RXD
RS485 / RS422
500-5015 INID MultiSmart reader RS485/RS422
500-5055 INID MultiSmart PIN reader RS485/RS422
LED 1 - Green
LED 2 - Amber
RS485 TRX+ RS422 TX+
RS485 TRX- RS422 TX-
RS485 n.c. RS422 RXRS485 n.c. RS422 RX+
GND
POWER
Caution: floating communication lines may cause spurious emissions.
Ensure all communication lines are properly biased and terminated.
RS232
500-5025 INID MultiSmart reader RS232
500-5065 INID MultiSmart PIN reader RS232
LED 1 - Green
LED 2 - Amber
CTS
TXD
RTS
RXD
GND
POWER
CAN bus
500-5035 INID MultiSmart reader CAN bus
500-5075 INID MultiSmart PIN reader CAN bus
LED 1 - Green
LED 2 - Amber
CANL
CANH
n.c.
n.c.
GND
POWER
Parts list
Reader front
Terminal connector
Mounting backplate
Enclosure screw
Installation sheet
qty: 1
qty: 1
qty: 1
qty: 1
qty: 1
Installation instructions
1 Determine an appropriate position for the reader
and drill two holes for mounting the backplate
and one hole for the cable, see diagram for
measurements. Do not mount readers less than
20 cm (8 inches) apart.
2 Pull the cable trough the hole in the backplate
and mount the backplate. Protect the cable
against sharp edges and any damage from
chafing.
3 Remove the terminal connector from the front of
the reader. Prepare the end of the cable and
wires, eliminate any loose or frayed strands. Keep
the wire ends as short as practical.
4 Connect the wires to the connector according to
the reader type. Wire ends, termination resistor
leads and optional permanent links shall be kept
as short as possible.
5 Place the connector on the reader pins.
6 Place the reader front over the hinge of the
backplate and close the reader (see diagram),
keeping the wiring in the lower part of the reader
housing. DO NOT use excessive force, retract the
cable if necessary.
7 Test the reader: apply power and present a valid
card. The LED bar should flash and the sounder
should produce a short tone indicating a
successful read. If the Host system is connected
to LED bar and sounder inputs these should
follow the functionality of the Host system.
8 The reader front should now be secured to the
backplate using the supplied enclosure screw.
This device contains 2 transmitters
Certifications
CE, FCC
FCC ID: YAB-ISOACRDR (model 50XX) 13.56 MHz
YAB-NGRPAOLF (model 40XX) 115 – 148 kHz
Compliance statement
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and
2) this device must accept any interference received,
including interference that may cause undesired
operation.
Warning (part 15.21)
Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
This in particular is applicable for the antenna which has
been delivered with the reader.
Consult your National Authority if any authorization
is needed for this product.
INID BV
For mounting, use only flat head screws with a
maximum shank size of 4 mm (5/32”, #7)
Mariëttahof 27
2033 WS Haarlem
The Netherlands
Phone: +31 (0)23 5335 420
Web: www.inid-readers.com
INID MultiSmart readers - installation and operation manual version 1.02; March 16, 2012

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
Language                        : en-US
Title                           : mdoc091201
Author                          : Mark Olde
Creator                         : Writer
Producer                        : OpenOffice.org 3.2
Create Date                     : 2012:03:21 18:20:54+01:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YAB-NGRPAOLF

Navigation menu