INID MultiSmart readers Cable specifications (non-shielded) interface Wiegand Clock/Data TTL serial RS232 RS485/RS422 (cable power) RS485/RS422 (local power) CAN bus maximum cable length meters feet 61 200 91 300 152 500 25 80 1.5 2.4 61 200 152 500 1220 4000 min.conductor size with 12 V supply2) mm2 AWG 0.25 24 0.34 22 0.25 24 0.34 22 0.25 24 system / speed dependent 2) With a 24V supply, minimum conductor size is AWG 24 for all interfaces and lengths. Features INID readers have a slim mullion mountable design and are designed for both in- and outdoor use. The INID reader can be mounted on any surface without significant performance degradation. For mounting to a metal surface however, a non-metallic spacer is advised. The switch mode power supply of the reader Specifications accepts a wide range input from 7 - 24 VDC. Higher input voltages result in lower current consumption Typical read range and allow for cost effective wiring with a smaller Technology distance conductor diameter. Mifare ISO card1) 60 mm 2.4 inch LF Proximity ISO card2) 30 – 60 mm 1.2 – 2.4 inch Reader output formats are determined by the 1) Depends on transponder antenna geometry. personalization of the card and/or configuration of 1) Depends on LF technology and card antenna geometry. the reader. Separate models are available for card-only and Power Supply card+PIN. 7 - 24 Volt DC (12 VDC recommended) Electrical interface options for WG/C&D/TTL serial, RS485/RS422, RS232 and CAN bus are available Power consumption with separate models. model average peak INID MultiSmart 1300 mW 1750 mW PIN code INID MultiSmart PIN 1300 mW 2050 mW INID PIN readers provide extensive options for PIN data formats and output protocols. The card and Current consumption @12 VDC3) model average peak PIN code data is sent separately and independently INID MultiSmart 110 mA 146 mA allowing host system determined operation for cardINID MultiSmart PIN 110 mA 171 mA only, PIN-only and card and PIN usage. 3) Use Ohm's law to calculate current at different voltages. Interface Inputs type and protection specifics Outputs type and protection specifics Dimensions 143 x 50 x 25 mm / 5.63 x 2 x 1 inch Material UL94-V0 rated LEXAN® 925U Operating temperature -25° to 65° C / -15° to 150° F Protection class IP54 Complete protection against contact, protection against dust deposit. Protection from splashed water. Indications User feedback is provided by a single LED bar and a multi-tone sounder. User feedback is controllable by the host system. PIN models are equipped with back lighting of the PIN code digits for usage in dark environments. Operation When a proximity card is read successfully the card associated code is send to the Host system, the LED bar lights briefly and the sounder sounds a short tone. When a PIN is entered the data is transmitted; at each key press a click sound is produced and the LED bar lights briefly. The back light of the PIN code lights up after a successful card read or at the first key press. The LED bar or individual LED bar segments and the buzzer are also controllable by the Host system. INID MultiSmart readers - installation and operation manual version 1.02; March 16, 2012 Connector Assignments Wiegand / Clock and Data / TTL serial 500-5005 INID MultiSmart reader WG/C&D/TTL 500-5045 INID MultiSmart PIN reader WG/C&D/TTL LED 1 - Green LED 2 - Amber D1 DATA TXD D0 CLOCK TXE BUZZER TAMPER GND POWER RXD RS485 / RS422 500-5015 INID MultiSmart reader RS485/RS422 500-5055 INID MultiSmart PIN reader RS485/RS422 LED 1 - Green LED 2 - Amber RS485 TRX+ RS422 TX+ RS485 TRX- RS422 TX- RS485 n.c. RS422 RXRS485 n.c. RS422 RX+ GND POWER Caution: floating communication lines may cause spurious emissions. Ensure all communication lines are properly biased and terminated. RS232 500-5025 INID MultiSmart reader RS232 500-5065 INID MultiSmart PIN reader RS232 LED 1 - Green LED 2 - Amber CTS TXD RTS RXD GND POWER CAN bus 500-5035 INID MultiSmart reader CAN bus 500-5075 INID MultiSmart PIN reader CAN bus LED 1 - Green LED 2 - Amber CANL CANH n.c. n.c. GND POWER Parts list Reader front Terminal connector Mounting backplate Enclosure screw Installation sheet qty: 1 qty: 1 qty: 1 qty: 1 qty: 1 Installation instructions 1 Determine an appropriate position for the reader and drill two holes for mounting the backplate and one hole for the cable, see diagram for measurements. Do not mount readers less than 20 cm (8 inches) apart. 2 Pull the cable trough the hole in the backplate and mount the backplate. Protect the cable against sharp edges and any damage from chafing. 3 Remove the terminal connector from the front of the reader. Prepare the end of the cable and wires, eliminate any loose or frayed strands. Keep the wire ends as short as practical. 4 Connect the wires to the connector according to the reader type. Wire ends, termination resistor leads and optional permanent links shall be kept as short as possible. 5 Place the connector on the reader pins. 6 Place the reader front over the hinge of the backplate and close the reader (see diagram), keeping the wiring in the lower part of the reader housing. DO NOT use excessive force, retract the cable if necessary. 7 Test the reader: apply power and present a valid card. The LED bar should flash and the sounder should produce a short tone indicating a successful read. If the Host system is connected to LED bar and sounder inputs these should follow the functionality of the Host system. 8 The reader front should now be secured to the backplate using the supplied enclosure screw. This device contains 2 transmitters Certifications CE, FCC FCC ID: YAB-ISOACRDR (model 50XX) 13.56 MHz YAB-NGRPAOLF (model 40XX) 115 – 148 kHz Compliance statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This in particular is applicable for the antenna which has been delivered with the reader. Consult your National Authority if any authorization is needed for this product. INID BV For mounting, use only flat head screws with a maximum shank size of 4 mm (5/32”, #7) Mariëttahof 27 2033 WS Haarlem The Netherlands Phone: +31 (0)23 5335 420 Web: www.inid-readers.com INID MultiSmart readers - installation and operation manual version 1.02; March 16, 2012
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 Language : en-US Title : mdoc091201 Author : Mark Olde Creator : Writer Producer : OpenOffice.org 3.2 Create Date : 2012:03:21 18:20:54+01:00EXIF Metadata provided by EXIF.tools