IRay Technology 02110113 Wireless Digital Flat Panel Detector User Manual 1
iRay Technology (Shanghai) Ltd. Wireless Digital Flat Panel Detector Users Manual 1
Contents
- 1. User manual
- 2. Users Manual-1
- 3. Users Manual-2
Users Manual-1
iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page Mars1717V User’s Manual Authors Dong Zhu Doc. No. 037-201-02 Date 2015.11.06 Version A1 Status Released Project Mars1717V /037 037‐201‐02 A1 2015.11.06 1 / 141 Mars1717V User’s Manual Author Dong Zhu Approver 037‐201‐02 A1 2015.11.06 Doc N0. Version Date Page iRay Technology (Shanghai) Ltd. Inspector 2/141 Yimin Huang Zhiqiang Fang Verified Record Department Name Signature Quality Wei PAN Test-verification Long Yu Date Department Name Signature Date Yong WANG Pre-production Marketing Yao LU Product Lin Liu Delivery Department Department Department Department Department Department Others Document History Ver. Date A0 2015.08.26 Revised Checked Approved by by by Dong Zhu Yimin.Huang Zhiqiang Fang Description First Released Update the A1 2015.11.06 Dong Zhu Yimin.Huang Zhiqiang Fang information to the customers about FCC Page 2 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 3/141 To Customers Congratulations on your purchase of the Mars1717V Wireless Digital Flat Panel (hereinafter referred to as Mars1717V) which is manufactured by iRay Technology (Shanghai) Ltd. (hereinafter referred to as iRay). At iRay, we strive to not only make the world-class products that deliver the best value possible to our customers but also offer the highest quality of service and customer care. Please take time to read through this user guide in order to utilize the product effectively. We hope you enjoy the experience with iRay Mars1717V. If you have any questions or suggestions, please feel free to contact us. Service Office Tel: +86 21 50720560 - 8059 Fax: +86 21 50720561 E-mail: service@iraychina.com Location: 2F, Building 7, No.590, Ruiqing Rd, Pudong, Shanghai, China PC: 201201 About FCC FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Page 3 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 4/141 Consult the dealer or an experienced radio/TV technician for help. FCC requires this product to be used indoors for the frequency range 5.15 to 5.25 GHz to reduce the potential for harmful interference to co-channel Mobile Satellite systems. Federal Communication Commission (FCC) Radiation Exposure Statement. This EUT is compliance with SAR for general population/uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and had been tested in accordance with the measurement methods and procedures specified in OET Bulletin 65 Supplement C. This equipment should be installed and operated contact with the radiator & your body. Notes on usage and management of the equipment Read all of the instructions in the user guide before your operation. Give particular attention to all safety precautions. Only a physician or a legally certified operator should use this product. The equipment should be maintained in a safe and operable condition by maintenance personnel. Use only computers and image display monitors complying with IEC 60601-1 or IEC 60950-1. For details, consult our sales representative or local iRay dealer. Use only the dedicated cables. Do not use any cables other than those supplied with this product. Request your sales representative or local iRay dealer to install this product Caring for your environment This symbol indicates that this product is not to be disposed of with your residential or commercial waste. Recycling iRay Equipment Please do not dispose of this product with your residential or commercial waste. Improper handling of this type of waste could have a negative impact on health and on the environment. Some countries or regions, such as the European Union, have set up systems to collect and recycle electrical or electronic waste items. Contact your local authorities for information about practices established in your region. If collection systems are not available, call iRay Customer Service for assistance. Disclaimer 1. iRay shall not be liable to the purchaser of this product or third parties for any damage, losse, or injury incurred by purchaser or third parties as a result of fire, earthquake, any accident, misuse or abuse of this product. Page 4 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 5/141 2. iRay shall not be liable to any damage, loss, or injury arising from unauthorized modifications, repairs, or alterations to this product or failure to strictly comply with iRay’s operating and maintenance instructions. 3. iRay shall not be liable for any damage or loss arising from the use of any options or consumable products other than those dedicated as Original iRay Products by iRay Technology. 4. It is the responsibilities of the user/attending physicians for maintaining the privacy of image data and providing medical care services. iRay shall not be responsible for the legality of image processing , reading and storage nor it shall be responsible for loss of image data for any reason. 5. Information regarding specification, compositions, and appearance of this product is subject to change without prior notice. Copyright All rights reserved No part of this publication may be reproduced in any form or by any means without the written permission of iRay. The information contained herein is designed only for use with iRay Mars1717V. Trademarks The iRay name and iRay logo are registered trademarks of iRay Technology (Shanghai) Ltd. Page 5 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 6/141 Symbols and Conventions The following symbols and conventions are used throughout the user guide. This symbol is used to identify conditions under which improper use of the product may cause death or serious personal injury. This notice is used to identify conditions under which improper use of the product may cause minor personal injury. This notice is used to identify conditions under which improper use of the product may cause property damage. This is used to indicate a prohibited operation. This is used to indicate an action that must be performed. This is used to indicate important operations and restrictions. This is used to indicate operations for reference and complementary information. Page 6 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 037‐201‐02 A1 2015.11.06 Doc N0. Version Date Page 7/141 Labels and markings on the equipment The contents of the labels and markings on iRay Mars1717V product are indicated below: Caution: please refer to the instructions in the user manual. This symbol is used to indicate that the equipment has passed CE testing and it is followed by the CE number. This symbol is used to identify the manufactuer’s series number which is after, below or adjacent to the symbol. The series number of iRay products is usually made of thirteen digits as shown below: A1A2A3A4 C1C2 M DD Y XXX Numerical Order Year Date Month Version Product Code Page 7 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 8/141 This symbol is used to indicate the name and address of the manufacturer. This symbol is used to indicate the name and address of iRay authorized representative in the European region. This symbol is used to indicate consultation of the user guide for general information. Safety Signs: please refer to the user guide for safety instructions Safety Signs:Dangerous Voltage Stand-by Handled with care FPD is allowed to withstand 100 kg on the surface This symbol is used to indicate the operational temperature limits. Page 8 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 9/141 This symbol is used to indicate the storage temperature limits. non-ionizing radiation FCC Federal Communications Commission certificate Package symbol, fragile. Package symbol, keep away from sunlight Package symbol, keep dry Package symbol, this symbol is used to indicate the humidity limits. Package symbol, keep the equipment up right Package symbol, do not roll the transportation package. Package symbol, this symbol is used to indicate stacking limit number. Page 9 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 10/141 Contents To Customers Symbols and Conventions Labels and markings on the equipment Contents 10 Safety Information 14 1.1 Safety precautions 14 1.2 Notes for Using 20 General Description 22 2.1 Scope 22 2.2 Model 23 2.3 Characteristic 23 2.4 Intended use 23 2.5 Standard Product Components 24 2.6 Optional Product Component 26 2.7 Components Description 27 2.8 Product Specification 30 2.8.1 Detector 30 2.8.2 Battery 32 2.8.3 Battery Charger 33 2.8.4 Power supply 34 2.8.5 Infrared Device (Optional) 34 2.8.6 AP Router (Optional) 34 2.8.7 Wireless Communication 34 2.8.8 Recommended Applicance Condition 35 2.8.9 Mechanical Outlines 36 2.8.10 Use Environment 38 Installation 39 3.1 Detector Installation 39 3.2 Battery Chargering Installation 42 Page 10 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 11/141 3.3 Software Installation 43 3.4 Panel Infrastructure 43 Operation 64 4.1 Main Operation 64 4.1.1 Software Mode 64 4.1.2 Inner Mode 67 4.1.3 Isync Plus Mode 69 4.2 Connection Build 71 4.3 Panel Configuration 72 4.4 Correction and Calibration Template Generation 72 4.4.1 Pre-offset Template Generation 72 4.4.2 Gain Calibration Template Generation 73 4.4.3 Defect Correction Template Generation 75 4.4.4 Lag Template Generation 78 4.5 Image Acquisition Continually 79 4.6 Image save 79 4.6.1 Multiple images 79 4.6.2 Single image 80 4.7 Image Check and upload 81 4.7.1 Local Image Check 81 4.7.2 Panel Image Upload 82 4.7.3 Panel Image Check 85 4.8 Defect Template Check and Modification 85 4.8.1 Defect Template Check 85 4.8.2 Defect Template Modification 86 4.9 Correction and Calibration Management 88 4.9.1 Correction and Calibration template synchronization 88 4.9.2 Correction and Calibration management 90 4.10 Sleep and Wake Up 92 4.10.1 Sleep 93 4.10.2 Wake Up 95 4.11 95 Firmware Update 4.11.1 MCU Update 95 4.11.2 FTP Server 97 4.11.3 Firmware Update 99 4.12 Short cut 101 Page 11 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 4.13 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 12/141 Software 102 4.13.1 Main GUI 102 4.13.2 Message Box 103 4.13.3 Configuration GUI 105 4.13.4 Correction and Calibration 113 4.13.5 Image Check and upload 115 4.13.6 Infrared Registration 116 Regulatory Information 118 5.1 Medical equipment safety standards 118 5.2 Guidance and manufacture’s declaration for EMC 119 5.3 Radio Frequency Compliance Information 123 5.3.1 FCC Compliance 124 5.4 Battery Safety Standards 124 5.5 Product Label 125 5.5.1 Detector 125 5.5.2 Battery 127 5.5.3 Battery Charger 128 Trouble Shooting 129 6.1 Cable Inspection 129 6.1.1 Ethernet cable 129 6.1.2 Date cable inspection 130 6.2 Adapter Inspection 130 6.2.1 Adapter connector definition 130 6.2.2 Inspection method 131 6.3 Battery Inspection 131 6.3.1 Battery pin definition 131 6.3.2 Inspect Method 132 6.4 Dock Inspection 132 6.4.1 Dock pin definition 132 6.4.2 Inspection method 133 6.5 Detector Main Unit Inspection 133 6.5.1 Get SDK and detector log 133 6.6 Power up failure inspection 135 6.7 Connection inspection 135 6.7.1 Connection failed in wired mode 135 Page 12 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 13/141 6.7.2 Connection Failed in Client Mode 136 6.7.3 Disconnect in AP Mode 136 6.8 Dark Image Acquisition After Exposure in Inner Mode 136 6.9 No Image Acquire after Exposure 137 6.10 Image Inspection 137 6.10.1 Artifact on bright image 137 6.10.2 Horizontal Line on bright image 137 6.10.3 Defective line 139 6.10.4 Defective point 139 6.10.5 TFT broken 139 Service Information 140 7.1 Product lifetime 140 7.2 Regular inspection and Maintenance 140 7.3 Repair 141 7.4 Replacement parts support 141 Page 13 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 14/141 1 Safety Information 1.1 Safety precautions Follow these safeguards and properly use the equipment to prevent injury and damage to any equipment/data. WARNING Installation and environment of use Do not use or store the equipment near flammable chemicals such as alcohol, thinner, benzene, etc. If chemicals are spilled or evaporate, it may result in fire or electric shock through contact with electric parts inside the equipment. Also, some disinfectants are flammable. Be sure to take care when using them. Do not connect the equipment with anything other than specified. Doing so may result in fire or electric shock. All the patients with active implantable medical devices should be kept away from the equipment. Power supply Do not operate the equipment using any type of power supply other than the one indicated on the rating label. Otherwise, it may result in fire or electric shock. Do not handle the equipment with wet hands. You may experience electric shock that could result in death or serious injury. Do not place heavy object such as medical equipment on cables and cords. Do not pull, bend, bundle, or step on them to prevent their sheath from being damaged, and do not alter them neither. Doing so may damage the cords which could result in fire or electric shock. Do not supply power to more than one piece of equipment using the same AC outlet. Doing so may result in fire or electric shock. Do not turn ON the system power when condensation has formed on the equipment. Doing so may result in fire or electric shock. Page 14 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 15/141 Do not connect a multiple portable socket-outlet or extension cord to the system. Doing so may result in fire or electric shock. To avoid the risk of electric shock, this equipment must only be connected to power supply with protective earth. Not doing so may result in fire or electric shock. Securely plug the power cord into the AC outlet. If contact failure occurs, or if metal objects come into contact with the exposed metal prongs of the plug, fire or electric shock may result. Be sure to turn OFF the power to each piece of equipment before connecting or disconnecting the cords. Otherwise, you may get an electric shock that could result in death or serious injury. Be sure to hold the plug or connector to disconnect the cord. If you pull the cord, the core wire may be damaged, resulting in fire or electric shock. WARNING Handling Never disassemble or modify the equipment. No modification of this equipment is allowed. Parts of the Mars1717V that are not serviced or maintained while in use with the patient Doing so may result in fire or electric shock. Also, since the equipment incorporates parts that may cause electric shock as well as other hazardous parts, touching them may cause death or serious injury. Do not place anything on top of the equipment. The object may fall and cause an injury. Also, if metal objects such as needles or clips fall into the equipment, or if liquid is spilled, it may result in fire or electric shock. Do not hit or drop the equipment. The equipment may be damaged if it receives a strong jolt, which may result in fire or electric shock if the equipment is used without being repaired. Do not put the equipment and pointed objects together. The equipment may be damaged. If so, the equipment should be used in bucky. Page 15 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 16/141 Have the patient take a fixed posture and do not let the patient touch parts unnecessarily. If the patient touches connectors or switches, it may result in electric shock or malfunction of the equipment. When a problem occurs Should any of the following occurs, immediately unplug the power cord of adaptor or battery, and contact your sales representative or local iRay dealer: When there is smoke, an odd smell or abnormal sound. When liquid has been spilled into the equipment or a metal object has entered through an opening. When the equipment has been dropped and damaged. Maintenance and inspection Please turn OFF the power of the equipment and unplug the power cord of adaptor before cleaning. NEVER use alcohol, ether and other flammable cleaning agent for safety. NEVER use methanol, benzene, acid and base because they will erode the equipment. DON’T dip the equipment into the liquid. Please make sure that the equipment’s surface & plugs are dry before turning ON. Otherwise, it may result in fire or electric shock. Clean the plug of the power cord periodically by unplugging it from the AC outlet and removing dust or dirt from the plug, its periphery and AC outlet with a dry cloth. If the cord is kept plugged in for a long time in a dusty, humid or sooty place, dust around the plug will attract moisture; this could cause insulation failure that may result in a fire. For safety reasons, be sure to turn OFF the power to each piece of equipment when performing inspections indicated in this manual. Otherwise, electric shocks may occur. CAUTION Page 16 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 17/141 Installation and environment of use Do not install the equipment in any of the locations listed below. Doing so may result in failure, malfunction, equipment falling, fire or injury. Close to facilities where water is used Where it will be exposed to direct sunlight Close to the air outlet of an air-conditioner or ventilation equipment Close to heat source such as a heater Where the power supply is unstable In a dusty environment In a saline or sulfurous environment Where temperature or humidity is high Where there is freezing or condensation In areas prone to vibration On an incline or in an unstable area Take care that cables do not become tangled during use. Also, be careful not to get your feet caught by cable. Otherwise, it may cause a malfunction of the equipment or injury of the user due to tripping over the cable. Non-medical equipment such as the battery charger, access point and IR data communication unit cannot be used in patient’s vicinity. Power supply Always connect the three-core power cord plug to a grounded AC power outlet. To make it easy to disconnect the plug at any time, avoid putting any obstacles near the outlet. Otherwise, it may not be possible to disconnect the plug in an emergency. Be sure to ground the equipment to an indoor grounded connector. Also, be sure to connect all the grounds for the system to a common ground. Do not use any power source other than the one provided with this equipment. Page 17 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 18/141 Otherwise, fire or electric shock may be caused due to leakage. Handling Do not spill liquid or chemicals onto the equipment. In case the patient is injured, it is not allowed to contact with blood or other body fluids. Doing so may result in fire or electric shock. In such a situation, protect the equipment with a disposable cover as necessary. Turn OFF the power and pull out the plug to each piece of equipment for safety when not used. CAUTION Handling Handle the equipment carefully. Do not submerge the equipment in water. The internal image sensor may be damaged if something hits against it or it is dropped. If the equipment is dropped, the drop sensor inside will turn red and the equipment will not be warranted by iRay. Do not place excessive weight on the equipment. Otherwise, the internal image sensor may be damaged and image may be incorrect. Page 18 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 19/141Uniform load:100 kg over the Local load:100 kg on an area whole area of the detector 4 cm diameter. surface. Be sure to use the equipment on a flat surface so it will not bend. Otherwise, the internal image sensor may be damaged. Be sure to securely hold the detector while using it in upright positions. Otherwise, the detector may fall over, resulting in injury to the user or patient, or may flip over, resulting in damage to the inner device. Keep the same load (same pressure) on the detector when acquiring the image. Or the image will be incorrect. CAUTION Do not close to fire, do not use in high temperature Do not invert positve and negative pole Do not contact with metal in case of short circuit Do not insert sharp objects into battery Do not beat battery Do not stand on battery Page 19 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 20/141 Do not use battery out of rules Do not dispose battery or change internal structure Do not submerge battery in water, please keep dry in storage and do not contact with water in use Please charge battery with charger following IEC60601-1 & IEC62133 Standards provide by us Do not mix battery with ones not provided by our company Do not charge battery with broken charger. 1.2 Notes for Using When using the equipment, take the following precautions. Otherwise, problems may occur and the equipment may not function correctly. Before exposure Be sure to check the equipment daily and confirm that it works properly. Be sure there be a battery installing on the Mars1717V to avoid the power off suddenly. Sudden heating of the room in cold areas will cause condensation to form on the equipment. In this case, wait until the condensation evaporates before performing an exposure. If the equipment is used while condensation is formed on it, problems may occur in the quality of captured images. When an air-conditioner is used, be sure to raise/lower the temperature gradually so that a difference of temperature in the room and equipment does not occur, to prevent condensation. The detector should warm up for 15 minutes before exposure or updating the gain map or defect map. During exposure Do not move the power or Ethernet Cables during exposure, or it may cause image noise or artifacts, even incorrect images. Do not use the devices near the equipment generating a strong magnetic field. Otherwise, it may cause image noise, artifacts or even incorrect images. Disinfection and Cleaning After every examination, wipe the patient contact surfaces of the detector using disinfectants such as ethanol, to prevent the risk of infection. For details on how to sterilize, consult a specialist. Do not spray the detector directly with disinfectants or detergents. Wipe it with a cloth slightly damped with a neutral detergent. Do not use solvents such as alcohol, thinner, benzene, acid and base. Doing so may damage the surface of the equipment. It’s recommended to use a waterproof non-woven cover as the isolated layer between detector and Page 20 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual the blooding patient. Page 21 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 21/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 22/141 2 General Description Mars1717V is a cassette-size wireless X-ray flat panel detector based on amorphous silicon thin-film transistor technologies. It is developed to provide the highest quality of radiographic image, which contains an active matrix of 3072×3072 with 139um pixel pitch. Detectors’ scitinator has two options which are Standard GOS(Gadolinium Sulfoxylate) and CsI(CaesiumIodide). However the most great improvement is Mars1717V supports wireless communication between detectors and PC. Mars1717V’s power supply includes battery. Mars1717V can be used as a real portable panel. 2.1 Scope This manual contains information about the iRay Mars1717V. All operators must read and understand this manual before using equipment. All information in this manual, including the illustrations, is based on equipment prototype. If configuration of your equipment does not have any of these items, information about these items in the manual does not apply to your equipment. Page 22 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 23/141 2.2 Model Mars □ □ □ PSI- GOS scintillator screen, VSI- CsI scintillator screen Product Application:cassette size detector Product dimension:1717,17inch×17inch Product serials:wireless digital flat panel detector serials Product Type: Battery-KV---------Rechargeable lithium battery Product Type: Charger-KV--------Battery charger 2.3 Characteristic Wireless static Flat Panel Detector used for general radiography. 17 × 17 inch Sync-Shot exposure trigger GOS or CsI scintillation screen. Easy to change the cable and upgrade firmware. Battery recycling 2.4 Intended use This equipment provides digital X-ray imaging for diagnosis of disease, injury, or any applicable health problem. The image is obtained as the result of X-ray passing through the human body and detected by the equipment. This device is intended to be used in the holder or bucky which is well insulated to panel. The holder or the bucky is well grounded. This panel is not intended for directly contacting with patient iRay will provide equipment and software support for integration of system. The length of both Ethernet Cable and DC Power Cable cannot exceed 3.5 m. or the impedance of protective earth connections may exceed the safety threshold. This panel is not intended for mammography or dental applications,and prohibited for pregnant women and children. According to the Mars1717V intended use and the result of risk management, identifying and describing the essential performance as the following: a) To get imaging of dark field, the Mars1717V shall be not influenced to the imaging acquisition Page 23 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual b) Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 24/141 To keep the data transmission function, the Mars1717V shall be not influenced to the data and signal transmission 2.5 Standard Product Components Mars1717V comes with power supply both 24V DC and battery package. Once powered on, it would build a connection with PC through Ethernet cable or Wireless connection. Item Description Mars1717V Detector 1 pcs Main Unit Medical Adapter for Detector and Battery Charger 2 pcs DC 24V 2 pcs Battery-KV Battery Pack Page 24 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 25/141 Ethernet Cable 1 pcs 3.5 m Gigabit Ethernet Cable 1 pcs 3m AC Power Cable 2 pcs DC Power cable 1 pcs 3.5 m Battery Charger 1 pcs Page 25 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 26/141 1 pcs Gain correction data Defect correction map SDK Manual CD-Rom 2.6 Optional Product Component Item Description Wireless AP Device 1 pcs Infrared Device 1 pcs Page 26 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 2.7 Components Description 2.7.1.1 Detector External Signals Input Control Panel Control Panel Item Name Description DC Input Interface 24V DC input Ethernet Interface Gigabit Ethernet Wire Detector Indicator Detector indicator of control panel Power Button Power button of control panel Page 27 037‐201‐02 A1 2015.11.06 27/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page Infrared Window Infrared device window Antenna Antenna Handle For the panel carried Maintenance Cover For service engineer to maintenance Battery Lock The lock button for detaching battery Detector Label Product information. Switch AP/Client Mode Switch Carbon Film Panel Carbon Film, have biocompatibility 2.7.1.2 Battery Item Name Description Battery Label Battery Interface 8 Pin Battery connector The location pin Indicator Installation direction indicator Page 28 037‐201‐02 A1 2015.11.06 28/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 2.7.1.3 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 29/141 Battery Charger Item Name Description Battery Interface 8 Pin Battery connector Capacity Indicator The indicator definition is as follow Power Indicator The indicator definition is as follow Hand Pull Position The limit ball plug DC Jack 24V DC input Power indicator definition: Power Indicator Lighting Status Operating Status OFF No external DC adaptor input GREEN ON External DC adaptor input The battery charging capacity indicator definition: X Group Indicator Lighting Status Operating Status I, II and III grid OFF No battery Insert Page 29 Mars1717V User’s Manual I grid blinking 037‐201‐02 A1 2015.11.06 Doc N0. Version Date Page iRay Technology (Shanghai) Ltd. 30/141 Battery Insert with capacity ≤30%,charging II and III grid OFF II grid blinking Battery Insert with capacity >30% and ≤60%, I and III grid OFF charging III grid blinking Battery Insert with capacity >60% and ≤95%, I and II grid OFF charging Battery Insert with capacity >95% and I and II grid OFF charging, when capacity = 100%, charging can III grid ON 2.7.1.4 stop automatically Power Supply Mars1717V supports both DC Power and Battery package input. 2.7.1.5 Infrared Device Mars1717V does not include Infrared Device. Users can select by themselves, however some basic requirements should be followed. 2.8 Product Specification 2.8.1 Detector 2.8.1.1 Basic Item Specification Model Mars1717V-PSI (GOS) Mars1717V-VSI (CsI) Image Sensor a-Si (Amorphous Silicon) TFT Pixel Size 139 μm Effective Array 3072 x 3072 Effective Area (H x V) 427 x 427 mm Fill Factor 60% Greyscales 14bit Spatial Resolution 2.8 Lp/mm (Standard GOS) Page 30 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 31/141 3.1Lp/mm (CsI) Image Acquisition Time (Wired) Preview Acquisition Time : 6 sec Processed Acquisition Time : 10 sec. (including Preview Time) Image Acquisition Time (Wireless) Preview Acquisition Time : 9 sec. Both AP mode and Client mode Processed Acquisition Time : 16 sec. (including Preview Time) Cycle Time Min. 13s @Wired;Min.16s @Wireless Power Consumption Max. 16W Dimension (L × W × H) 460 x 460 x 15.2 mm Weight (with one battery) Mars1717V-PSI: 4.3 kg without battery, 4.6 kg with battery Mars1717V-VSI: 4.5 kg without battery, 4.8 kg with battery Image Transfer Wired : Gigabit Ethernet(1000BASE-T) Wireless : IEEE802.11a/b/g/n Data Transmission Rate (Wireless) 802.11b : Max. 11Mbps 802.11a/g : Max. 54Mbps 802.11n : Max. 300Mbps (MIMO 2x2) X-ray Energy 2.8.1.2 40kV to 150kV MTF The MTF with GOS should meet the following table 2.8.1.3 Spatial frequency (lp/mm) MTF (GOS) MTF(CsI) 1.0 0.39 0.60 2.0 0.12 0.31 3.0 0.04 0.15 DQE The DQE with GOS should meet the following table Page 31 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 037‐201‐02 A1 2015.11.06 Doc N0. Version Date Page 32/141 Spatial frequency (lp/mm)@RQA5 DQE (GOS)@3.2uGy DQE (CsI)@2.5uGy 0.30 0.52 1.0 0.15 0.39 2.0 0.05 0.24 3.0 0.01 0.16 2.8.2 Battery Page 32 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Item Model Rated Capacity Nominal Voltage Charge Voltage Battery-KV Min. 3950mAh, Typ. 4180mAh @ Discharge 0.2C 10.8V 12.6±0.05V 8.25V Charging Method CC-CV Charge 0℃-+45℃, Discharge -20℃-+60℃ 1 month -20℃-+45℃ Storage Temperature 3 month 0℃-+30℃ 6 month 5℃-+20℃ Relative Humidity Dimension (L × W × H) Weight 2.8.3 65±20% 210 x 115 x 7.5 mm 0.29 kg Battery Charger Item Model Simultaneous Charging Full charging time Rated power supply Dimension (L × W × H) Weight 037‐201‐02 A1 2015.11.06 Specifications Discharged End Voltage Operating Temperature Doc N0. Version Date Page Specifications Charger-KV 2 battery packs 2 hours 24V(DC) 300 x 263 x 42 mm 1.26 kg Page 33 33/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 2.8.4 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 34/141 Power supply Mars1717V supports both DC Power and Battery package input. Item DC Power Battery Package 2.8.5 Specifications 24V(DC), 0.8A 10.8V(DC),1.78A Infrared Device (Optional) Mars1717V does not include Infrared Device. Users can select by themselves, however some basic requirements should be followed. Item IRDA Protocol Compliant with IrDA V1.0 and V1.1 USB Compliant with USB V2.0 and V1.1 Data Rate 2.8.6 Specifications Max. 4Mbps AP Router (Optional) Mars1717V do not include AP Router. Users can select AP Router as they wish, however specification below is a requirements. Item Specifications Wireless Standard IEEE 802.11 a/b/g/n Frequency Range 2.412 ~ 2.4835 GHz and 5.15 ~ 5.85 GHz 802.11b : Max. 11Mbps Wireless Data Rate Wired Data Rate 2.8.7 802.11a/g : Max. 54Mbps 802.11n : Max. 300Mbps (MIMO 2x2) Max. 1Gbps Wireless Communication Item Wireless Standard Description IEEE802.1a/b/g/n 2.4G: 2.412 ~ 2.4835 GHz Frequency Range 11: (Ch. 1-11) – United States 13: (Ch. 1-13) – Europe Page 34 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 35/141 14: (Ch. 1-14) – Japan 5G: 5.15 ~ 5.85 GHz 12: United States 19: Europe 8: Japan 802.11b : Max. 11Mbps Data Transmission Rate 802.11a/g : Max. 54Mbps 802.11n : Max. 300Mbps (MIMO 2x2) 802.11b: CCK, DQPSK, DBPSK Modulation 802.11a/g: 64 QAM, 16 QAM, QPSK, BPSK 802.11n: 64 QAM, 16 QAM, QPSK, BPSK Transmission Power 2.8.8 Max.17dBm Security WPA, WPA-PSK, WPA2, WPA2-PSK, WEP 64bit & 128bit Antenna 2 Dual Band internal antenna Recommended Applicance Condition Item Operating System CPU Memory Hard Disk LAN Card Description Windows XP/7 32/64bit Intel Core i73.6G 4G DDR3 160 G Intel Pro EXP9301CT PRO Gigabit Network Adapter with PCIe interface Page 35 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 2.8.9 Mechanical Outlines Page 36 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 36/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Page 37 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 37/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 38/141 2.8.10 Use Environment Operating Storage Temperature Temperature change Humidity AtmosphericPr essure Pressure Change 5~30℃ <1k/min 45~85% RH 700~1000hPa1 0~70% RH <10kp/min (1kp=1.0197E-5Pa) -20~60℃ <1k/min 45~85%RH 700~1000hPa1 0~70% RH The Mars1717V serial detectors shall operate at an altitude specified not more than 3000m. Page 38 <10kp/min (1kp=1.0197E-5Pa) iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 39/141 3 Installation 3.1 Detector Installation 3.1.1.1 Attach Battery Pack Mars1717V can be powered on by both battery package and DC power. Once battery package is inserted or DC power is on, Detectors would be activated immediately. If none of battery and DC power is on, Mars1717V would power off. Please see below for battery installation. Make sure that the connectors on the battery package are pointed to the cave in battery compartment. Slide battery package into battery compartment (Make sure battery capacity overpass 10%). Slide the battery lock lever. 3.1.1.2 Attach DC Power Please see below for DC power installation. Page 39 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Connect one end of DC Power Cable to the Medical Adapter As figure is power interface and Ethernet interface Connect another end of DC Power Cable to the DC input of the detector. If user want to use wired Ethernet, connect the Ethernet cable to Ethernet interface. 3.1.1.3 Booting Up On the control panel, user can press power button to power on/off. If detector is powered off, users can press the button for 4 seconds to power on the detector when battery is inserted and battery capacitor is not less than 10%, or direct current power is connected. If detector is powered on, users can press the button for 4 seconds to shut down the detector. On the other hand, it can also be used as reset internal control IC when button is active for 8s. Page 40 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 40/141 Doc N0. Version Date Page iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 037‐201‐02 A1 2015.11.06 41/141 After booting up the detector, use can check the status LED indicator of detector. Operating Status Power Indicator Lighting Status Battery Operating Capacity DC Input OFF Power OFF Orange ON Power ON ≤10% NO Green ON Power ON Input Orange Fast Blinking Orange Slow Blinking Green Fast Blinking Green Slow Blinking OFF after Green ON with 1 sec. OFF after Orange ON with 1 sec. Battery Capacity >10%, NO DC No Battery with DC Input Power OFF ≤10% YES Power ON ≤10% YES Power OFF >10% YES Power ON >10% YES Power OFF >10% NO Power OFF ≤10% NO Link indicator is as table: Link Indicator Lighting Status Description OFF Panel shut down wired connection broken and wireless connection not ready Blue blinking Client mode, wireless connection is ready for connection, but not connected Blue ON Page 41 Client mode, wireless connection is built Doc N0. Version Date Page iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 037‐201‐02 A1 2015.11.06 42/141 AP mode, wireless AP is ready for connecting Green ON Green blinking Wired Connection is built Panel Initialization Infrared configuration Status indicator is as table: Status Indicator Lighting Status Description Panel shut down Panel is idle Green ON Data Transmission Orange blinking Fatal Error Orange ON Panel Initialization OFF AP/Client indicator is as table: AP/Client Indicator Lighting Status Description 1. 2. OFF Wireless connection ok,connection mode is Green ON AP Wireless connection ok,connection mode is Blue ON Client 3.2 Battery Chargering Installation Operating Network connection error; Network connection is wired connection; Figure Page 42 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page Unload Battery from battery charger. Insert battery into battery charger. Note align the interface position as figure. Press the battery to the bottom of battery compartment. 3.3 Software Installation In the case of IDemo doesn’t work, please install following VC redistribute package. 3.4 Panel Infrastructure Mars1717V supports three connection modes as follows: 1) Wired connection mode Page 43 037‐201‐02 A1 2015.11.06 43/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 2) Wireless Client Mode 3) Wireless AP Mode To build connection between workstation and Panel, User should follow steps below. 3.4.1.1 Wired Mode To complete Wired connection configuration, users have to finish actions listed below. Configuration of Ethernet Card To begin configuration of Ethernet Card, users should finish 31.1.2 Page 44 037‐201‐02 A1 2015.11.06 44/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Connect detector to PC with Ethernet Cable Open Network configuration Open Local network configuration Page 45 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 45/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page open IPV4 setting IP setting Network mask setting IP address: 192.168.8.188 Subnet mask: 255.255.255.0 Open SDK and start connection IP and port setting 3.4.1.2 IP: 192.168.8.188 Port: 28000 Wireless Client mode To complete Wireless Client mode configuration, users have to finish actions listed below. Configuration of External wireless AP Connect one end of Gigabit Ethernet Cable to PC,Connect another end to LAN port of External wireless AP Page 46 037‐201‐02 A1 2015.11.06 46/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Open Network configuration Open Local network configuration Page 47 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 47/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page open IPV4 setting IP setting Network mask setting Select “Obtain an IP address automatically” Open browser and type 192.168.1.1 Log into external wireless AP Page 48 037‐201‐02 A1 2015.11.06 48/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 49/141 Wireless setup Configure 2.4GHz wireless network SSID: NETGEAR_BIG_24 Security: WPA2-PSK Password: 12345678 Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] Configure 5GHz wireless network SSID: NETGEAR_BIG_50 Security: WPA2-PSK Password: 12345678 Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] Page 49 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page LAN setup Configure LAN IP address IP address: 192.168.8.1 Subnet Mask: 255.255.255.0 External Wireless AP Reboot Apply above settings and reboot your wireless router. Recover Local Network IPv4 setting of PC wired Ethernet interface IP setting IP address: 192.168.8.188 Network mask setting Subnet mask: 255.255.255.0 Configuration of detector Either Wired Cable or Infrared device can be used to configure detector in wireless client mode. Page 50 037‐201‐02 A1 2015.11.06 50/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 51/141 a.To start configuration with wired cable. It is necessary to finish 3.2.2.1, then proceed to the steps below. Click “Configure” in IDemo Click “Network setting” Click “Add” Page 51 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 52/141 Change SSID and Key, Click “Apply” Click “write Config to FPD” Do not remove wired cable until “write to FPD” button recovers Since we have chosen default SSID and password, it would connect to wireless AP immediately after powered on next time. B. To start Infrared configuration. Please see below Connect Infrared device with Workstation Page 52 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Start IrDARegister.exe Click “ ” to open wifi setting Page 53 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 53/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Change SSID and password,do not select AP mode Click “Apply” Click” ” Page 54 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 54/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Click”Start” Point Infrared device to detector’s infrared interface Page 55 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 55/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page Do not click”Exit” until success Disconnect Infrared device from PC 3.4.1.3 Wireless AP mode To complete Wired connection configuration, user has to finish actions listed below. Configuration of detector Either Wired cable or Infrared device can be used to configure detector wireless AP mode. a.To start wired cable configuration, users should finish 3.4.1.1, then proceed to the steps below. Click “Configure” in IDemo Page 56 037‐201‐02 A1 2015.11.06 56/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Click “Network setting” Select AP mode Change SSID and password setting Click “write Config to FPD” Do not remove wired cable until “write to FPD” button recovers Page 57 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 57/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 58/141 Since we have chosen default SSID and password, it would connect to wireless AP immediately after powered on next time. b.To start Infrared configuration, please see below Connect Infrared device with PC Start IrDARegister.exe Page 58 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Click “ ” to open wifi setting Select “AP mode” Page 59 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 59/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Change SSID and password and other parameter Click “Apply” Click” ” Page 60 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 60/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Click”Start” Do not click”Exit” until success Page 61 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 61/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Configuration of external wireless card Open Wireless signal List Select SSID which belongs to Detectors, input password and log into system Open wireless card configuration Page 62 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 62/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual open IPV4 setting IP setting IP address: 192.168.8.188 Network mask setting Subnet mask: 255.255.255.0 Open SDK and start connection IP and port setting IP: 192.168.8.188 Port: 28000 Page 63 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 63/141 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 64/141 4 Operation Mars1717V provides SDK for users to integrate detector into their DR system. Additionally, it also provides an application for demonstration, i.e. Idemo. User can use Idemo to control detector without DR system. 4.1 Main Operation To Acquire X-ray image is the main operation of Mars1717V. Most importantly, detector should build synchronization with X-ray generator.Mars1717V is born with two ways to acquire X-ray image, that is Software Mode, Inner Mode and Isync Plus Mode. 4.1.1 Software Mode 4.1.1.1 Block Diagram Software mode is the basic way to acquire X-ray image. Please see figure below for general feature Workstation is a host PC device installed with idemo and SDK. Chapter 3.1 has described how to establish connection between detectors and workstation. In software mode, workstation does not have to control X-ray generator. Users would decide when to shoot X-ray. Page 64 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 4.1.1.2 037‐201‐02 A1 2015.11.06 Doc N0. Version Date Page 65/141 Work flow Click “Prep” Panel preparation,Wait until the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X-ray at any time. However the longer time you wait. The worse image would be. So please shoot once X-ray generator is ready. After shooting, Click”Acquire” Wait for image uploaded 4.1.1.3 Timing Setting To set a clear scenario for program, see diagram below for details Clear Process Detector Workstation Xray Generator 1. Exposure Prohibited Exposure Acquisition 10 Anode Rotate 11 Exposure Enable X ray shooting Workstation receives “prep” request, send command “Clear” to panel. Page 65 12 Exposure Prohibited iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 2. Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 66/141 Panel receives “clear” from workstation, start detector internal clear cycle. At the same time, detector would tell workstation “Exposure Prohibited”. 3. Detector finished ”Clear” action and send a message reminding “Exposure Enable” 4. Workstation shows “Exposure Enable” on the iDemo’s message bar to tell user shoot X-ray now. 5. User triggers X-ray generator to initialize and do anode rotation to prepare for X-ray shooting. 6. X-ray generator finishes preparation for X-ray shooting and reminds user to shoot. 7. X-ray generator starts releasing X-ray 8. X-ray generator finishes X-ray shooting. 9. Workstation receives “Acquire” request, send command “Data Acquisition” to panel. 10. Panel receives “Data Acquisition” from workstation, start data acquisition operation. 11. Panel completes image acquisition and begins to send data to workstation. 12. Workstation receives all image data from panel. If Hardware Pre-offset and Hardware calibration is selected, image is the final image. If Software Pre-offset and Software Calibration is selected, image would be the raw image, workstation would finish image processing work and show on screen. If Hardware Post offset and Hardware calibration is selected, image got would be preview image (2x2 binning). After step12, panel would do another dark image acquisition. With both light image and dark image, panel completes all the correction and calibration process. Finally, panel uploads processed image to workstation. If Software Post offset and Software calibration is selected, image got would be preview image (No binning). After step12, Workstation sends another “clear Acquire” command to panel, panel finishes a dark image acquisition and uploads dark raw image to workstation. With both light image and dark image, workstation completes all the correction and calibration process. Finally, corrected image shows on screen. Page 66 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 67/141 4.1.2 Inner Mode 4.1.2.1 Block Diagram Workstation (Software ) HVG Tube Workstation is a host PC device installed with iDemo and SDK. Chapter 3 has described how to establish connection between panels and workstation. In inner mode, workstation does not control X-ray generator. Users would decide when to shoot X-ray. 4.1.2.2 Work Flow Click ”Prepare” Panel preparation,Wait unitl the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X‐ray in exposure window. However the longer time user waits, the worse image would be. So please shooting once X‐ray generator is ready. After shooting , X‐ray in panel would trigger panel to start image. Wait for image uploaded Page 67 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual 4.1.2.3 Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 68/141 Timing Setting To set a clear scenario for program, see diagram below for details 1. Workstation receives “prep” request and sends “Clear” to panels. 2. Panel receives “clear” from Workstation, start clear operation. Meanwhile, panel would send “Exposure Prohibited” to Workstation. 3. Panel finishes “Clear” operation and send “Exposure Enable” to Workstation. 4. Workstation shows “Exposure Enable” on the iDemo’s message bar to tell user shoot X-ray. 5. User triggers X-ray generator to initialize and do anode rotation to prepare for X-ray shooting 6. X-ray generator finishes preparation and reminds users. 7. X-ray generator begins releasing X-ray 8. X-ray generator finishes X-ray shooting. 9. X-ray sensor in panel triggers panel to start image acquisition operation. 10. Panel completes image acquisition and begins to send data to Workstation. 11. Workstation starts receiving image data from panel. 12. Workstation receives all image data from panel. If Hardware Pre-offset and Hardware calibration is selected, image got is the final image. If Software Pre-offet and Software Calibration is selected, image got would be raw image, workstation would finish image processing work and show on screen. If Hardware Post offset and Hardware calibration is selected, image got from detector would be preview image (2x2 binning). After step12, Detector would do another dark image acquisition. With both light image Page 68 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 69/141 and dark image, detector completes all the correction process. Finally, detector uploads corrected image and workstation shows on screen. If Software Post offset and Software calibration is selected, image got from panel would be preview image (No binning). After step12, Workstation sends another “clear Acquire” to panel, panel would do dark image acquisition and uploads dark raw image to workstation. With both light image and dark image, workstation completes all the correction process. Finally, corrected image shows on screen. 4.1.2.4 Abnormal Action Action1: after Step4, if user wants to cancel this exposure cycle, Idemo provides an “Abort Exp” function to close exposure windows. However, Idemo allows user to click “Abort Exp” until Workstation receives first image. Action2: after Step4, if user does not shoot X-ray in exposure windows, panel would close exposure windows automatically and send a message to workstation that waiting for X-ray shooting is overtime. Meanwhile, panel would also start image acquisition. After image acquisition, panel sends image to workstation. 4.1.3 Isync Plus Mode 4.1.3.1 Block Diagram Page 69 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 70/141 Workstation is a host PC device installed with iDemo and SDK. Chapter 3 has described how to establish connection between panel and Workstation. In Isync Plus mode, User doesn’t interact with Workstation. After shooting, images would be shown on screen immediately. 4.1.3.2 Work Flow Check SDK to make sure panel is ready Shoot X-ray X-ray sensor in panel triggers panel to stop flushing the panel After fixed time, panel starts image acquisition Wait for image uploaded 4.1.3.3 Timing Setting Workstation Panel X ray Generator Anode Rotate Ray 1. X-ray generator is ready for X-ray shooting and begins to release X-ray. 2. Workstation receives “Exposure Prohibited” from Panel. 3. Panel starts uploading Pre-dark image and Light image to Workstation for preview. If hardware offset is selected, panel would do offset first, and then upload preview image (2X2 binning). Page 70 iRay Technology (Shanghai) Ltd. Mars1717V User’s Manual Doc N0. Version Date Page 037‐201‐02 A1 2015.11.06 71/141 4. Panel starts uploading Post-dark image to Workstation. If hardware offset is chosen, panel would do correction and calibration first, then upload processed image to Workstation. 5. Workstation receives “Exposure Enable” from Panel. 4.2 Connection Build Click “Start” Input IP address and port number. The IP address should be the same as the IP address of the network card connected with panel. The port should use the default value of 28000; Click “Connect”; Note: 1. Once changing connection from different network card, user must re-connect panel with different IP address. 2. Switching between wired and wireless connection does not need any extra operation. Page 71
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : dell Create Date : 2015:11:06 14:46:50+08:00 Modify Date : 2015:11:19 10:52:08+08:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Title : Microsoft Word - 037-201-02 Mars1717V User Manual A1 20151106 Creator : dell Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:11:19 10:52:08+08:00 Producer : Acrobat Distiller 9.3.2 (Windows) Document ID : uuid:bba11b2b-a51d-431f-aa4c-70d961dc05cd Instance ID : uuid:f1c7bb73-03e8-4694-9c6e-8144f4ae044f Page Count : 71EXIF Metadata provided by EXIF.tools