Ibis Networks 300 RF Engine Module User Manual DataSheet IM 301x

Ibis Networks Inc. RF Engine Module DataSheet IM 301x

User Manual

Download: Ibis Networks 300 RF Engine Module User Manual DataSheet IM 301x
Mirror Download [FCC.gov]Ibis Networks 300 RF Engine Module User Manual DataSheet IM 301x
Document ID3596187
Application IDqmEzCYauJFP0KScGyMa8Yw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize22.66kB (283223 bits)
Date Submitted2017-10-09 00:00:00
Date Available2017-10-10 00:00:00
Creation Date2017-09-15 15:12:42
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2017-10-03 12:25:19
Document TitleMicrosoft Word - DataSheet-IM-301.docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: ibisadmin

IM-301
™
InteliMeter Lighting Power-Pack
FEATURES
•
•
•
•
•
•
•
85V-305V 20A
ZigBee Pro
128 bit AES Security
13dBm RF Power
RoHS Compliant
Hard-Wired
Plenum Rated
DESCRIPTION
The IM-301 Power-Pack monitors and controls energy usage for lighting or other electrical
systems. It works with InteliSocketsTM to form a secure wireless mesh network for control and
reporting of data. Each network is anchored by an InteliGatewayTM base station providing
connectivity to the InteliNetworkTM, a cloud-based data collection and analysis application. The
IM-301 provides a low voltage 24Vdc supply for motion detectors and ambient light sensors,
which can then control the operating state of the meter in either occupancy or vacancy mode
(meeting Title24 requirements). A wide input voltage range accommodates 120V, 240V, and
277V lighting systems.
PERFORMANCE
Parameter
Input Voltage (RMS)
Input Frequency
Output Current (RMS)
Power Consumption
Reporting Interval
Accuracy (Energy)
Accuracy (Voltage)
Accuracy (Interval)
Resolution
RF Range
RF Transmit Power
ZigBee Channels
Size
Symbol
VIN
Min
85
47
Typ
60
IOUT
1.5
15
Max
305
63
20
255
0.5
50
-4
11
12
26
3.5 x 3.5 x 1.5
Ibis Networks ∙ 841 Bishop Street Suite 1601 ∙ Honolulu, HI 96813 ∙ www.ibisnetworks.com
06/21/17
Units
Hz
ms
W-s
dBm
inches
IM-301
™
InteliMeter Lighting Power-Pack
COMPLIANCE
Agency
UL916 – Energy Management Equipment
ZigBee Profile (Plover)
FCC
File
E470522
0x114B
2AECN300
ENVIRONMENTAL
Parameter
Operating Temperature
Storage Temperature
Relative Humidity
Symbol
TO
TS
RH
Min
-40
Typ
25
Max
40
100
95
Units
PUSHBUTTON / LED
Action
Press (no hold)
Pressed while plugging in
Press and hold 3+ seconds
Press and hold 8+ seconds
Result
Toggle outlet state (on/off).
Ignored.
Soft reset. Re-start socket. Similar to plugging in.
Hard reset. All conditions are set to default. Normally this sets
socket back to FACTORY channel and hive. However, if socket
has been deployed on CUSTOMER channel and hive, a hard reset
will then toggle between FACTORY and CUSTOMER settings. This
is a useful feature to correct a socket that has been accidentally
reset to FACTORY. It also provides a quick method to perform a
manual self-heal. If on FACTORY, LED will be red, CUSTOMER
green.
Color
Black
Yellow
Flashing Red or Green
Red
Green
Meaning
Socket has no power.
Boot-up sequence in effect. Typically ½ second duration.
Socket is attempting to join mesh network.
Outlet is off.
Outlet is on.
Ibis Networks ∙ 841 Bishop Street Suite 1601 ∙ Honolulu, HI 96813 ∙ www.ibisnetworks.com
06/21/17
IM-301
™
InteliMeter Lighting Power-Pack
USAGE
The IM-301 is a direct replacement for your existing power-packs, offering a quick low-cost
upgrade for your lighting system. You can now monitor exact power consumption for each
bank of lighting. Each InteliMeter is another wireless node on your Ibis mesh along with
InteliSockets. Set lighting schedules, or use the motion detector input to trigger control of
other sockets. The IM-301 is not limited to lighting and can be used for other purposes, such as
control of existing outlets or hard-wired devices. A wide input voltage range and 20 amp
capability opens up a world of possibilities.
WIRING
The IM-301 is designed to install as part of your electrical wiring infrastructure. The enclosure
mounts to a standard electrical box using a feed-thru grommet, keeping “hot” wires internal.
Class 2 secondary low voltage control wires are for connecting standard motion detectors or
ambient light sensors. The external pushbutton and motion detector are both optional.
Ibis Networks ∙ 841 Bishop Street Suite 1601 ∙ Honolulu, HI 96813 ∙ www.ibisnetworks.com
06/21/17
IM-301
™
InteliMeter Lighting Power-Pack
FCC
This equipment has been tested and found to comply with the limits for a class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
The user is cautioned that changes and modifications made to the equipment without the
approval of manufacturer could void the user’s authority to operate this equipment.
To satisfy RF exposure requirements, this device and its antenna must operate with a
separation distance of at least 20 cm from all persons and must not be co-located or operating
in conjunction with any other antenna or transmitter.
Ibis Networks ∙ 841 Bishop Street Suite 1601 ∙ Honolulu, HI 96813 ∙ www.ibisnetworks.com
06/21/17
IM-303
Inline InteliMeter™
FEATURES
•
•
•
•
•
•
85V-265V 30A
ZigBee Pro
128 bit AES Security
13dBm RF Power
Surge Protected
Hard-Wired
DESCRIPTION
The IM-303 InteliMeter measures and controls energy consumption. It works with other
InteliSocketsTM and InteliMetersTM to form a secure wireless mesh network for control and
reporting of data. Each network has an InteliGatewayTM base station providing connectivity to
the InteliNetworkTM, a cloud-based data collection and analysis application. InteliMeters can be
configured to operate on any of the 16 ZigBee channels, with channel 26 set as factory default.
In addition, the hive (PANID) has over 4000 possible settings, preventing nearby systems from
interfering with each other. The IM-303 was designed with residential hot water heaters in
mind.
PERFORMANCE
Parameter
Input Voltage (RMS)
Input Frequency
Output Current (RMS)
Power Consumption
Reporting Interval
Accuracy (Energy)
Accuracy (Voltage)
Accuracy (Interval)
Resolution
RF Range
RF Transmit Power
Sockets per Network
ZigBee Channels
ZigBee Hive
Size
Symbol
VIN
Min
85
47
Typ
Max
265
63
30
60
IOUT
15
255
0.5
50
-4
12
120
26
0x3FFF
11
0x3000
4.5 x 3.5 x 2
Ibis Networks ∙ 841 Bishop Street Suite 1601 ∙ Honolulu, HI 96813 ∙ www.ibisnetworks.com
06/21/17
Units
Hz
ms
W-s
dBm
inches
IM-303
Inline InteliMeter™
COMPLIANCE
Agency
UL916 – Energy Management Equipment
ZigBee Profile (Plover)
FCC
File
E470522
0x114B
2AECN300
ENVIRONMENTAL
Parameter
Operating Temperature
Storage Temperature
Relative Humidity
Symbol
TO
TS
RH
Min
-40
Typ
25
Max
40
100
95
Units
PUSHBUTTON / LED
Action
Press (no hold)
Pressed while plugging in
Press and hold 3+ seconds
Press and hold 8+ seconds
Result
Toggle outlet state (on/off).
Ignored.
Soft reset. Re-start socket. Similar to plugging in.
Hard reset. All conditions are set to default. Normally this sets
socket back to FACTORY channel and hive. However, if socket
has been deployed on CUSTOMER channel and hive, a hard reset
will then toggle between FACTORY and CUSTOMER settings. This
is a useful feature to correct a socket that has been accidentally
reset to FACTORY. It also provides a quick method to perform a
manual self-heal. If on FACTORY, LED will be red, CUSTOMER
green.
Color
Black
Yellow
Flashing Red or Green
Red
Green
Meaning
Socket has no power.
Boot-up sequence in effect. Typically ½ second duration.
Socket is attempting to join mesh network.
Outlet is off.
Outlet is on.
Ibis Networks ∙ 841 Bishop Street Suite 1601 ∙ Honolulu, HI 96813 ∙ www.ibisnetworks.com
06/21/17
IM-303
Inline InteliMeter™
WIRING
The IM-303 is designed to be hard-wired between the power feed and a standard 240V 30A hot
water heater. #10 wires connect to screw terminals, designated at RED (neutral), BLACK (hot)
and bare or GREEN (earth).
FCC
This equipment has been tested and found to comply with the limits for a class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
The user is cautioned that changes and modifications made to the equipment without the
approval of manufacturer could void the user’s authority to operate this equipment.
To satisfy RF exposure requirements, this device and its antenna must operate with a
separation distance of at least 20 cm from all persons and must not be co-located or operating
in conjunction with any other antenna or transmitter.
Ibis Networks ∙ 841 Bishop Street Suite 1601 ∙ Honolulu, HI 96813 ∙ www.ibisnetworks.com
06/21/17

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : ibisadmin
Create Date                     : 2017:09:15 15:12:42Z
Modify Date                     : 2017:10:03 12:25:19-07:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : ibisadmin
Title                           : Microsoft Word - DataSheet-IM-301.docx
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:10:03 12:25:19-07:00
Producer                        : GPL Ghostscript 8.15
Document ID                     : uuid:7f7a4f6b-9a4e-42ca-be2b-7020b0602593
Instance ID                     : uuid:150a4a16-5cef-4f2c-8b58-1314da7c1615
Page Count                      : 7
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AECN300

Navigation menu