Inkel JF43E1900CFN03 CDMA Fiber-Fed Repeater System User Manual

INKEL Corporation CDMA Fiber-Fed Repeater System

Contents

User Manual

1. Overview Figure 1. System Configuration Optic  repeater  is  a  type  of  BTS  sub-systems.  It  is  designed  to  cover  the  radio-shadowed  areas  that  could  be  occurred  by  obstructions  among  base  stations.  The system  provides  high  quality  communication  at  reasonable  cost  by  adopting  high technologies.  For  example,  the  system  adopted  WDM  that  multiplexes UL and DL signals onto a single fiber cable, so that the system can be installed  at  low  cost  and maintained with ease.  2. Major Advantages A. REMOTE 1) It is easy to install and maintain the system, because it is designed as small size, light weight, and low power consumption. 2) It is reliable by adopting water and moisture resistant structure. 3) Remote control Operation, maintenance, and repair  is  easy by using  the system  that provides alarm and information on the Gain Control of Remote Cell, output level control, power on/off, internal temperature monitoring, and problems concerning optic module.  Remote control can be performed by RF modem so that operation and maintenance personal can use it easily. And it was designed to operate with comprehensive  network management system. 4) Transmission and Receiving with 1 Core Optic Fiber It  use  WDM  which  enables  2  wave-length  (Forward:  1550nm,  Reverse:  1510nm)  to Base StationBTSDonorRemote
simultaneously be transmitted and received through 1 Core Optic Fiber 5) Optic  AGC  (Automatic  Gain  Control):  It  is  regularly  keeping  the  loss  between  optic sections. 6) ALC (Automatic Limit Control): It makes to  limit  the level of output power less than the regular level.    B. DONOR 1) It is easy to install and maintain the system, because it is designed as small size, light weight, and low power consumption. 2) Donor shelf is designed to mount into 19” shelf and also, can  be  mounted  into  the enclosure that is following the IP65 standard. 3) Control Operation, maintenance, and repair  is  easy by  using  the system  that provides alarm and information on the Gain Control of Donor Unit, output level control and problems concerning  optic  module.  Remote  control  can  be  performed  by  RF  modem  so  that operation and maintenance personal can use it easily. And it was designed to operate with comprehensive network management system. 4) Transmission and Receiving with 1 Core Optic Fiber It  use  WDM  which  enables  2  wave-length(Forward:1550nm,  Reverse:1510nm)  to simultaneously be transmitted and received through 1 Core Optic Fiber 5) Optic AGC(Automatic Gain Control) : It is regularly keeping the  loss  between  optic sections.
3. The name and function of each module     A. REMOTE BATTERYOPTIC UL_1 DL/UL_0 AC_OUTAC_INBATTERYOPTICUL_1 DL/UL_0 AC_IN Figure 2. A plan of Remote     3.1 Interior Module ① Optic It changes the optic signal (from Donor) into RF signal and RF signal (from Remote) into optic signal. ② DL_UL Drive The module changes the level of a signal on DL path into the desired level. It has a variable attenuator. The antenna output level on DL path is adjustable by the attenuator. It amplifies the level of a signal on UL0 path.   It amplifies the level of a signal on UL1 path after down-conversion. ③ UL_SAW Drive It contains saw filters for band selection.   ④ Local & Modem Drive
It generates local signals for band selection on UL paths. It  performs  FSK  modulation  and  demodulation  for  communication  between  Donor and Remote. ⑤ LPA (30Watts) It is amplified into high output power for transmitting the Down  Link  signal  to antenna. ⑥ LNA It amplifies signals from antenna for achieving good characteristics of noise figure.   ⑦ Cavity filter It  deletes  useless  signals  except  band  that  is  used  for  service.  DL/UL  signals  are already distinguished at part of Antenna.   Regarding Up Link Path, It deletes signals except band that is used for service. ⑧ PSU It changes the input power (50~88VAC) into DC+27V, DC+15V and DC+7V  for operating each module. ⑨ RSM (Remote Status Monitoring) It  manages  the  communication  of  Donor  and  controls  alarm  signal and all sorts of control.  3.2 Other parts ①  RF Connector : 7/16 DIN Female ②  Power Cable : Power Feeder 625 JCAT 3R Coaxial Cable ③  Optic  Adapter  :  Sam-Hwa  KFBG  #16  (Waterproof,  UL  certified,  the quality of the material SUS)-using SUNFLEX pipe ④  Bracket : The bracket is used for mounting the repeater on the wall.
B. DONOR      - Donor Shelf -              - Donor Enclosure –  3.3 Interior Module ①  optic It changes the optic signal (from Remote) into RF signal and RF signal (from Donor) into optic signal. ②  DL Drive This module changes the forward signal into optimum level and has attenuation for setting the input level of optic module. It contains saw filters for band selection. It contains FSK modem for communication with remote. ③  UL Drive It amplifies the output signal of optic module for getting optimum level. There is a function  of  attenuator  for  module  gain  control  and  setting  the  gain  between  optic sections regularly. ④  Local Drive This module makes local signal for Reverse diversity path.   It up-converts of UL1 path. It generates local signals for band selection on DL paths.
⑤  Wireless Modem & control board They make the signal for communicating the upper systems. The communication is for  receiving  and  sending  the  alarm  and  control  signals.  Also,  the  data  including  the information of product is communicating with MCU. ⑥  PSU         It  changes  the  input  power  (110~230VAC)  into  DC+27V,  DC+15, and DC+7V for operating each module. ⑦  MCU It has a computer interface. The operator can monitor several kinds of alarms and control the system by using the connected computer.  3.4 Other parts ①  RF connector: N female (Donor enclosure), SMA female (Donor shelf) ②  Optic adapter: FC/ APC type ③  Bracket (Enclosure): The bracket is used for mounting the repeater on the wall.
4. How to install the system Typical Installation Instructions                         A. Checking the contents B. Put the repeater at the place where to install it C. Install Repeater inside at convenient location on a wall D. Installation exterior antenna & Laying Feeding cables E. Measurement of receiving level from base station i. Connect  feeding  cable,  which  has  been  connected  with  directional antenna for base station, with input of spectrum analyzer. ii. Set measurement environment of Frequency, Span, BW and Amplitude, etc of the spectrum analyzer. Install Repeater inside at convenient location on a wall Fix repeater body on a wall Installation exterior antenna & Laying Feeding CompletionTesting  for calling quality Inspection Checking the contentsMeasurement of Receiving Level from Base Station Connect power supply adapter
iii. Verify Channel Power value of input signal. F. Connect to RF Cable G. Connect power supply adapter Caution: Should check the input power whether 50~88VAC.(For Remote) Caution: Should check the input power whether 110~230VAC.(For Donor)   H. Testing for calling qualities  5. User Attention 1) Do not open the case of repeater 2) Do not excessive pressure to Repeater. 3) Please use a rated voltage. 4) The repeater must have been installed considering environmental factor.  6. Troubleshooting 1) The PSU LED Causes  Action Power  cable  of  the  power  supply  unit has not been connected.    Check connection of power system Failure of the LED  Checking the items of alarm LED 2) The repeater transmits no signal Causes  Action Coaxial  cable  connecting  the  repeater and measuring system is defective Replace  coaxial  cable  or  power  detector module Power  system  of  interior  of  the repeater has not been connected. Check  power  connection  of  module  of interior of the repeater
7. Specifications 7.1 General System Electrical Specifications Characteristic  Specification Frequency DL: 1930.625 ~ 1989.375MHz UL: 1850.625 ~ 1909.375MHz Frequency bandwidth  58.75 MHz (DL/UL) Channel bandwidth and spacing  Applying to CDMA Frequency Assignment System time delay  5 ㎲_max Characteristic impedance  50 ohm 7.2 DL Path specifications(Remote)   Remote  Donor Input power range  -34 ~ -24dBm/total  -3 ~ +7dBm/Total Gain  61~77dB  -2dB Gain control step  0.5dB  0.5dB Maximum output power  43dBm/total  +5dBm/Total Output VSWR  1.5:1  1.5:1 Ripple  3dB max  2dB max 7.3 UL Path specifications   Remote  Donor Input Power  -55 dBm max  0dBm max Gain  +55dB  -25 ~ 0dB Input VSWR  1.5:1  0.5dB OIP3  25dBm max  1.5:1 Ripple  3dB max  25dBm max 7.4 Mechanical Specifications   Remote  Donor Output/Input connector  7/16 DIN Female  N Female Input AC power  50~88VAC  110~230VAC Dimensions (W*H*D)  13.8*31.5*10.6(inch)  482.6*266*400(mm) Weight  79lbs Max  36lbs max  WARNING Any  changes  or  modifications  not  expressly approved  by  the  manufacturer could void the user’s authority to operate the equipment.