Insight SiP ISP130301 Bluetooth Low Energy Module User Manual AN140101R2

Insight SiP Bluetooth Low Energy Module AN140101R2

Contents

User manual_AN140101R2

Download: Insight SiP ISP130301 Bluetooth Low Energy Module User Manual  AN140101R2
Mirror Download [FCC.gov]Insight SiP ISP130301 Bluetooth Low Energy Module User Manual  AN140101R2
Document ID2330335
Application IDa4MK2nn9T44UlifPJzh9SQ==
Document DescriptionUser manual_AN140101R2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize121.62kB (1520196 bits)
Date Submitted2014-07-21 00:00:00
Date Available2015-01-18 00:00:00
Creation Date2014-05-20 14:54:17
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2014-05-20 14:54:17
Document TitleUser manual_AN140101R2
Document CreatorMicrosoft® Office Word 2007
Document Author: Gen

APPLICATION NOTE
ISP130301-DK1
AN140101
Use of ISP130301-DK1
Introduction
Scope
This document gives details on hardware and software for using and testing Insight SiP Bluetooth Low
Energy module ISP130301.
Contents
1. Recommended Documentation ............................................................................................... Page 1-2
2. ISP130301-DK1 Hardware Content ......................................................................................... Page 1-3
3. Software Installation ................................................................................................................ Page 1-4
4. Hardware Description .............................................................................................................. Page 1-5
5. Basic Application using ISP130601 Test Board ....................................................................... Page 1-8
6. Basic Sensor Application with ISP131001 ............................................................................. Page 1-17
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 1/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
1. Recommended Documentation
The following Nordic Semiconductor documents and Dev Kits (software portion) are required to
understand the complete setup and programming methods:
Documents:
nRF51822 Development kit User Guide (hardware section should be partially ignored – ISP
development kit hardware replaces Nordic Semiconductor hardware).
nRF51 Series Reference Manual.
nRF51822 PS (data sheet).
S110 / S120 nRF51822 SoftDevice Specification.
nRF51 SDK.
Dev kits (software portion):
nRFgo Studio.
nRF51 Software Development Kit (SDK):
- Precompiled HEX files.
- Source code.
- Keil ARM project files.
S110 / S120 nRF51822 SoftDevice.
Master Control Panel.
To access these files, go to www.nordicsemi.com and log in to your Nordic My Page account, enter your
product key and download the files. Instructions can be found in Chapter 3.
ISP documents that complement the above:
AN140101 App Note – this document.
DS130301 module data sheet.
ISP130601 Test Board schematic SC130602.
ISP131001 Sensors Board schematic SC131002.
ISP130603 Interface Board schematic SC130604.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 2/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
2. ISP130301-DK1 Hardware Content
1 x ISP130603
Interface Board
1 x J-Link Lite CortexM-9
JTAG/SWD Emulator
1 x nRF51822
Development Dongle
(PCA10000)
1 x ISP130601
Test Board
1 x ISP131001
Sensors Board
5 x ISP130301 module
samples
1 x Battery Holder
CR2032
1 x FPC jumper cable 22 pin
1 x FPC jumper cable 14 pin
1 x Lithium Battery
CR2032
1 x FPC jumper cable 10 pin
1 x 10 pin connector
1 x 2-lead patch cable
1 x USB cable
1 x 5V power supply
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 3/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
3. Software Installation
This paragraph shows you the steps to follow for software installation.
1.
Download and install Keil MDK-ARM Lite from https://www.keil.com/demo/eval/arm.htm to your hard
drive.
2.
Download and run the J-Link Software and documentation pack for Windows from
http://www.segger.com/jlink-software.html. The serial number from your SEGGER J-Link hardware
is needed to identify your device and can be found printed on the chip on the J-Link Lite emulator
board.
3.
Go to www.nordicsemi.com and log in to your Nordic My Page account.
4.
Select MY KEYS from the left menu. This takes you to the My Keys page.
5.
Enter the product key (included in this kit) into the Product Key field and click Add.
6.
Click MY PRODUCTS in the left menu.
7.
From the Add product dropdown, select the product name and click Add. The chosen product is now
listed in the below Overview, My Products table.
8.
In the Overview, My Products table click the Downloads link next to the product name to go directly
to the relevant product page download section.
9.
Download, install and run nRFgo Studio.
10. Download, install and run Master Control Panel. The software is on the CD and if you want the last
version, you can find it on the Nordicsemi website. (x86 is for 32 bits windows and x64 is for 64 bits
windows)
11. Download and run the nRF51 SDK installer. Make sure to choose the Keil MDK-ARM installer
option.
12. Download the S110 / S120 nRF51822 SoftDevice.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 4/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
4. Hardware Description
4.1
ISP130301 Module
ISP130301 is a Bluetooth Low Energy module with integrated antenna.
This module is based on Nordic Semiconductor nRF51822 2.4 GHz wireless SoC. nRF51822
integrates nRF51 series 2.4 GHz transceiver, a 32 bit ARM Cortex™-M0 CPU, flash memory, and
analogue and digital peripherals. nRF51822 can support Bluetooth low energy and a range of proprietary
2.4 GHz protocols. The ISP130301 module measures 8 x 11 x 1.2 mm3. The module integrates all the
decoupling capacitors, the 16 MHz and 32 kHz crystals, their load capacitors, the DC-DC converter
component, the RF matching circuit and the antenna in addition to the wireless SoC. For more details,
see Insight SiP module data sheet (document DS130301).
4.2
ISP130601 Test Board
ISP130601 is the basic application test board that has dimensions of 18 x 30 mm².
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 5/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
It encloses:
ISP130301 BLE module
3 x FPC connectors in order to access the nRF51822 GPIOs:
- 1 x 10 pin FPC connector on top side of the board.
- 1 x 14 pin FPC connector on top side of the board.
- 1 x 22 pin FPC connector on bottom side of the board.
The ISP130601 electrical schematic is presented in document SC130602.
4.3
ISP131001 Sensors Board
ISP131001 is the sensor application board that has dimensions of 12.5 x 25 mm².
It encloses:
ISP130301 BLE module.
ST Micro LPS331AP temperature and barometer sensor.
Freescale FXOS8700CQ 6-axis linear accelerometer and magnetometer sensor.
Rohm SML-P11MTT86 mini-LED.
Software to read/drive the sensors.
Removable 10 pin FPC connector for software loading.
The ISP131001 electrical schematic is presented in document SC131002.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 6/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
4.4
ISP130603 Interface Board
ISP130603 is the application type interface board that has dimensions of 86 x 80 mm².
RS232 port header
(RXD and TXD)
22 pin FPC
connector
10 pin FPC
connector
14 pin FPC
connector
Equivalent
to PORT0
on nRFgo
Motherboard
Current
measurement
pins
Voltage
measurement
pins
Equivalent
to PORT1
on nRFgo
Motherboard
Reset button
RS232 port header
(RTS and CTS)
Supply connector
5V DC
Equivalent
to PORT2
on nRFgo
Motherboard
Not used
App Vcc
enable jumper
Equivalent
to PORT3
on nRFgo
Motherboard
JTAG
connector
RS232 serial port connector
Set App Vcc
(Vcc in mV = 500 + Jumpers)
The ISP130603 electrical schematic is presented in document SC130604.
4.5
nRF51822 Development Dongle (PCA10000)
The reader should refer to the corresponding paragraph in nRF51822 Development Kit User Guide
document.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 7/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
5. Basic Application using ISP130601 Test Board
5.1
Basic BLE Proximity Application
This paragraph shows you how to set up and program a BLE proximity application on top of a SoftDevice
that will send data on a Bluetooth link from the ISP130601 Test Board to the Master Emulator. In order to
use Bluetooth Low Energy radio, the software is loaded in 2 parts:
S110 / S120 SoftDevice using nRFgo Studio (hex file, no source).
Proximity Application using Keil uVision4.
Then Master Emulator is connected and Proximity Application is launched.
S110 / S120 SoftDevice loading
1.
2.
3.
4.
Connect the SEGGER J-Link board to the ISP130603 Interface Board with the 10 pin flat cable (1.27
mm pitch, provided in the Development Kit).
Connect the provided USB cable from the J-link board to your computer.
Connect the ISP130602 Test Board to the ISP130603 Interface Board with the 10 pin, 14 pin and 22
pin FPC jumper cables (0.5 mm pitch, provided in the Development Kit)
To ensure that power supply starts correctly, disconnect Enable jumper, connect to OFF and then
Enable after supplying 5V from DC power supply (provided in the Development kit).
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 8/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
5.
6.
7.
Start nRFgo Studio.
Select nRF51 Programming.
Click Erase all.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 9/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
8.
Browse to SoftDevice hex file and click Program.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 10/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
Proximity Application loading
1.
2.
Start Keil uVision4.
Select Project then Open Project in order to open ble_app_proximity.
3.
Click Build Target and Load.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 11/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
Master Emulator and Proximity Application
1.
2.
3.
Connect Development Dongle PCA10000 (Master Emulator) into a USB port on your computer.
Start Master Control Panel.
Click Start Discovery.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 12/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
4.
If you have an error message as indicated in the photo :
It means that the nRF51822 Development Dongle (PCA10000) is not programmed. For your
information, please refer to the nRF51822 Development Kit User Guide document as indicated in
our application note ISP130301-DK1 part 4.5 on page 14-7. You can find this user guide on the
Nordicsemi website. The procedure to program the dongle (PCA10000) is described on page 13. I
enclose a copy of the user guide for your convenience.
1) Open the Master Control Panel from the Start menu (Start > All Programs > Nordic
Semiconductor > Master Control Panel).
2) Make sure the Development Dongle is detected. The Master Emulator item list should show
COMnn-xxxxxxxxx (nn gives the COM port number; xxxxxxxxx is the SEGGER
serial number printed on the dongle). Restart the application if it doesn’t appear in the item
list. Before continuing, make sure you have selected the correct device by verifying the serial
number in the item list with the serial number printed on the Development Dongle.
3) When you use the Development Dongle for the first time, you must first program it
with the Master Emulator Firmware.
a. In the Master Control Panel menu click File and select Flash Programming.
b. Click Browse. This opens a browser that automatically points to the location of the
c. mefw_nrf51822__firmware.hex ( will be replaced by a number
d. giving the version of the actual firmware).
e. The Master Control Panel Firmware file is located in:
f. C:\Program Files (x86) \ Nordic Semiconductor \ Master Control Panel
\\firmware\
g. pca10000\MEFW_nRF51822__firmware.hex.
h. Select the Master Emulator Firmware file and click Open.
i. Click Program to start programming the selected device.
j. When the programming is finished click Exit to go back to the main window.
5.
6.
Click Select Device.
On the following display, click successively on Bond, Service Discovery and Enable Services.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 13/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
7.
You can note Battery voltage is sent by the ISP130601 Test Board to the Master Emulator via the
Bluetooth link. The application is written to send a value that changes cyclically.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 14/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
5.2
Direct Test Mode (UART)
This paragraph shows you how to set up and program the Direct Test Mode through the UART on
ISP130601 Test Board.
Direct Test Mode Set-up
1.
2.
3.
4.
5.
6.
Connect the SEGGER J-Link board to the ISP130603 Interface Board with the 10 pin flat cable (1.27
mm pitch, provided in the Development Kit).
Connect the USB cable from the J-link board to your computer.
Connect the ISP130601 Test Board to the ISP130603 Interface Board with the 10 pin, 14 pin and 22
pin FPC jumper cables (0.5 mm pitch, provided in the Development Kit)
On the ISP130603 Interface Board, connect the 2-lead patch cable in order to connect RXD to
P0_16 and TXD to P0_17. Make sure the RXD/TXD labels match for each wire. This matches the
default setting in the SDK project ble_app_dtm (be careful: depending on the ble_app_dtm version,
the ports used could be different).
Connect a USB to serial cable converter from RS232 port connector of the ISP130603 Interface
Board to a USB port on your computer.
Connect the 5V DC power supply to the ISP130603 Interface Board.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 15/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
Direct Test Mode Loading
1.
2.
Start Keil uVision4.
Select Project then Open Project in order to open ble_app_dtm.
3.
Click Build Target and Load.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 16/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
Direct Test Mode Testing
1.
2.
Start nRFgo Studio.
Select Direct Test Mode.
3.
For details on how to use the Direct Test Mode, press F1 to open the nRFgo Studio help.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 17/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
6. Basic Sensor Application with ISP131001
This paragraph shows you how to set up a Sensor application with ISP131001 Sensors Board that will
send data via the Bluetooth link to the Master Emulator or to an iPhone.
Two types of demonstration are presented. The first one is directly executable with hardware and
software provided in the Development Kit using Master Control Panel application. The second
demonstration requires the use of an iPhone (4S or higher). The iphone application is available on
demand only as an App that can be installed for development purposes via the Apple developer
program. The procedure to obtain the App from Insight SiP and demonstration of the Sensor application
with iPhone are described hereafter.
6.1
1.
2.
3.
4.
5.
On Master Control Panel
Place the CR2032 lithium battery into the battery holder.
Connect the battery holder to the Sensors Board ISP131001.
Connect Development Dongle PCA10000 (Master Emulator) into a USB port on your computer.
Start Master Control Panel.
Click Start Discovery.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 18/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
6.
7.
Click Select Device.
On the following display, click successively on Bond, Service Discovery and Enable Services.
8.
You can note data that transit between the ISP131001 Sensors Board and the Master Emulator via
the Bluetooth link:
- Data of the accelerometer/magnetometer on the above left figure
- Data of the temperature/pressure on the above right figure
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 19/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
9.
To switch off ISP131001 Sensors Board, disconnect battery holder as seen in the figure below.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 20/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
6.2 On iPhone Device (4S or higher)
The Sensor application is available on demand from Insight SiP. The iPhone App is a demonstration App
that is provided "as is" in order to demonstrate the Smart Bluetooth sensor node. Only one iPhone is
allowed per development kit.
The installation procedure for the Sensor application is described hereafter:
1.
Contact Insight SiP at contact@insightsip.com and communicate the UDID of your iPhone device
(4S or higher). The UDID is available when connecting your iPhone to you computer and starting
iTunes on your computer.
2.
3.
4.
Once you receive reply from Insight SiP, open Safari web browser on your iPhone device.
Open the URL link provided by Insight SiP.
The InsightSiPDemo application is downloaded and installed. You should see the following screen
on your iPhone device.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 21/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
Then you will be able to set up the application demonstration as follows:
1.
2.
3.
Place the CR2032 lithium battery into the battery holder.
Connect the battery holder to the Sensors Board ISP131001.
Start InsightSiPDemo application on your iPhone, click Connect and select your Sensors Board
(name is InsightSiP_xxxxx).
4.
Click Accelerometer. A Calibration phase invites you to rotate the ISP131001 Sensors Board. Then,
a starship on your iPhone screen follows the Sensors board movement.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 22/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
5.
Click Back and Temperature to start temperature and pressure demonstration.
6.
Click Back and LED. A prompt will invite you to pair the Sensors Board with the iPhone. Click Pair.
The LED lights up.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 23/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.
APPLICATION NOTE
ISP130301-DK1
7.
To switch off ISP131001 Sensors Board, disconnect battery holder as seen in the figure below.
May 20, 2014
Document Ref: isp_ble_AN140101_R2
Page 24/24
Insight SiP – Green Side – 400 avenue Roumanille – BP 309 – 06906 Sophia-Antipolis Cedex – France – www.insightsip.com
The information contained in this document is the property of Insight SiP and should not be disclosed to any third party without written permission.
Specification subject to change without notice.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 24
Language                        : fr-FR
Tagged PDF                      : Yes
Author                          : Gen
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2014:05:20 14:54:17+02:00
Modify Date                     : 2014:05:20 14:54:17+02:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AAQS-ISP130301

Navigation menu