Intermec Technologies IM4 IM4 User Manual IM4 Integration Guide
Intermec Technologies Corporation IM4 IM4 Integration Guide
Contents
OEM Integration Guide
Integration Guide IM4 Module Intermec Technologies Corporation Corporate Headquarters 6001 36th Ave. W. Everett, WA 98203 U.S.A. www.intermec.com The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and service Intermec-manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Intermec. Information and specifications contained in this document are subject to change without prior notice and do not represent a commitment on the part of Intermec Technologies Corporation. © 2005 Intermec Technologies Corporation. All rights reserved. The word Intermec, the Intermec logo, Norand, ArciTech, CrossBar, Data Collection Browser, dcBrowser, Duratherm, EasyADC, EasyCoder, EasyLAN, Enterprise Wireless LAN, EZBuilder, Fingerprint, i-gistics, INCA (under license), Intellitag, InterDriver, Intermec Printer Network Manager, IRL, JANUS, LabelShop, Mobile Framework, MobileLAN, Nor*Ware, Pen*Key, Precision Print, PrintSet, RoutePower, SmartSystems, TE 2000, Trakker Antares, and Virtual Wedge are either trademarks or registered trademarks of Intermec Technologies Corporation. Throughout this manual, trademarked names may be used. Rather than put a trademark (™ or ®) symbol in every occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement. There are U.S. and foreign patents pending. ii IM4 Module Integration Guide Contents Contents Before You Begin..................................................................................................................v Safety Summary.......................................................................................................v Safety Icons ............................................................................................................vi Global Services and Support ...................................................................................vi Who Should Read This Document? ..................................................................... vii Related Documents .............................................................................................. vii Patent Information .............................................................................................. viii About the IM4..................................................................................................................... 9 Configuring the IM4 as a PC Card Module (Default)........................................................ 10 Configuring the IM4 as a Serial Module ............................................................................ 12 How the IM4 Operates...................................................................................................... 14 Heat Dissipation Requirements ......................................................................................... 14 Power Requirements .......................................................................................................... 15 Antenna Requirements ...................................................................................................... 15 Specifications..................................................................................................................... 17 IM4 Module Integration Guide iii Contents iv IM4 Module Integration Guide Before You Begin Before You Begin This section provides you with safety information, technical support information, and sources for additional product information. Safety Summary Your safety is extremely important. Read and follow all warnings and cautions in this document before handling and operating Intermec equipment. You can be seriously injured, and equipment and data can be damaged if you do not follow the safety warnings and cautions. Do Not Repair or Adjust Alone Do not repair or adjust energized equipment alone under any circumstances. Someone capable of providing first aid must always be present for your safety. First Aid Always obtain first aid or medical attention immediately after an injury. Never neglect an injury, no matter how slight it seems. Resuscitation Begin resuscitation immediately if someone is injured and stops breathing. Any delay could result in death. To work on or near high voltage, you should be familiar with approved industrial first aid methods. Energized Equipment Never work on energized equipment unless authorized by a responsible authority. Energized electrical equipment is dangerous. Electrical shock from energized equipment can cause death. If you must perform authorized emergency work on energized equipment, be sure that you comply strictly with approved safety regulations. IM4 Module Integration Guide Before You Begin Safety Icons This section explains how to identify and understand warnings, cautions, and notes that are in this document. You may also see icons that tell you when to follow ESD procedures. A warning alerts you of an operating procedure, practice, condition, or statement that must be strictly observed to avoid death or serious injury to the persons working on the equipment. Avertissement: Un avertissement vous avertit d’une procédure de fonctionnement, d’une méthode, d’un état ou d’un rapport qui doit être strictement respecté pour éviter l’occurrence de mort ou de blessures graves aux personnes manupulant l’équipement. A caution alerts you to an operating procedure, practice, condition, or statement that must be strictly observed to prevent equipment damage or destruction, or corruption or loss of data. Attention: Une précaution vous avertit d’une procédure de fonctionnement, d’une méthode, d’un état ou d’un rapport qui doit être strictement respecté pour empêcher l’endommagement ou la destruction de l’équipement, ou l’altération ou la perte de données. Note: Notes either provide extra information about a topic or contain special instructions for handling a particular condition or set of circumstances. Global Services and Support Warranty Information To understand the warranty for your Intermec product, refer to your OEM agreement. Disclaimer of warranties: The sample code included in this document is presented for reference only. The code does not necessarily represent complete, tested programs. The code is provided “as is with all faults.” All warranties are expressly disclaimed, including the implied warranties of merchantability and fitness for a particular purpose. Web Support Visit the Intermec web site at www.intermec.com to download our current documents (in PDF). To order printed versions of the Intermec manuals, contact your local Intermec representative or distributor. Visit the Intermec technical knowledge base (Knowledge Central) at intermec.custhelp.com to review technical information or to request technical support for your Intermec product. vi IM4 Module Integration Guide Before You Begin Telephone Support These services are available from Intermec Technologies Corporation. In the U.S.A. and Canada call 1-800-755-5505 and choose this option Service Description Factory Repair Request a return authorization number for authorized service center repair. Technical Support Get technical support on your Intermec product. Service Contract Status Inquire about an existing contract, renew a contract, or ask invoicing questions. Schedule Site Surveys or Installations Schedule a site survey, or request a product or system installation. Ordering Products Talk to sales administration, place an order, or check the status of your order. Outside the U.S.A. and Canada, contact your local Intermec representative. To search for your local representative, from the Intermec web site, click Contact. Who Should Read This Document? This integration guide explains how to integrate the IM4 module into a computer or other device. It is written for the person who will be evaluating the IM4 to integrate into their device or for the person who will be engineering the device to accommodate the IM4. Before you install and configure the IM4, you should be familiar with Intermec RFID systems and how to implement them. You should also be familiar with your network and general networking terms, such as IP address. Related Documents The Intermec web site at www.intermec.com contains our current documents that you can download in PDF format. To download documents 1 Visit the Intermec web site at www.intermec.com. 2 Click Service & Support > Manuals. 3 In the Select a Product field, choose the product whose documentation you want to download. To order printed versions of the Intermec manuals, contact your local Intermec representative or distributor. IM4 Module Integration Guide vii Before You Begin Patent Information There may be U.S. and foreign patents pending. viii IM4 Module Integration Guide About the IM4 About the IM4 The Intermec Intellitag™ IM4 module is designed to let you easily incorporate the reading and writing of RFID tags into your computers, printers, and other mobile devices. It is an enhanced Intermec replacement for the existing IM3 module and the RFID PC card. MMCX connector 68-pin connector IM4 Intellitag Module You can use the IM4 in most worldwide RFID applications. Intermec has versions of the IM4 that cover the UHF band from 865 MHz to 928 MHz. The IM4 is a PCMCIA Type II card package with a standard 68pin connector. When you integrate the IM4 into your computers, the connector functions as either a PC card module (default) or as a serial module. Note that the IM4: • has different pinouts if it is functioning as a PC card module or as a serial module. To use the IM4 as a serial module, you need to tie pins 7, 44, and 45 to ground. Pin 34 Pin 1 Pin 68 Pin 35 • may have heat dissipation requirements. In most situations, the IM4 has an Overtemperature mode that will sufficiently protect it against very high temperatures. However, if you use the IM4 in a high duty cycle application, you may want to attach a heatsink to it. • has certain power requirements. The PC card slot must be able to supply enough power for the card, which is about 900 mA. Most laptop PC card slots do not supply this much power. • has antenna connector requirements for its one antenna. IM4 Module Integration Guide Configuring the IM4 as a PC Card Module (Default) Configuring the IM4 as a PC Card Module (Default) In PC Card mode, the IM4 interface looks like a standard 16C550 UART. It appears as a serial port and you can use a communications program, such as HyperTerminal, to communicate with it using the Basic Reader Interface (BRI). For more information on the BRI, see the Basic Reader Interface (BRI) Programmer’s Reference Guide (P/N 937-000-001). All signals are 3.3 V logic levels (5 V tolerant inputs). Low High Notes Inputs 0 V to 0.8 V 2.4 V to 5.5 V Input current is ±10 µA max Outputs 0.4 V Max @ 8 mA 2.9 V min @ -8 mA Note: Pins with a # in the pin name indicate an active low signal. Pins 7 (CE1#), 44 (IORD#), and 45 (IOWR#) determine if the IM4 operates in PC Card mode or in Serial mode. If the three signals are NOT grounded, the IM4 operates in PC Card mode. 10 IM4 Module Integration Guide Configuring the IM4 as a PC Card Module (Default) PC Card Module Pinouts Pin No. Pin Name Definition Pin No. Pin Name Definition GND Ground Vss 35 GND Ground Vss D3 Data bit 3 36 CD1# Card detect 1 (GND) D4 Data bit 4 37 D11 Data bit 11 D5 Data bit 5 38 D12 Data bit 12 D6 Data bit 6 39 D13 Data bit 13 D7 Data bit 7 40 D14 Data bit 14 CE1# Card enable 1 41 D15 Data bit 15 A10 Address bit 10 42 CE2# Card enable 2 OE# Output enable 43 VS1# Voltage sense 1 (NC) 10 A11 Address bit 11 44 IORD# “I/O read from host” 11 A9 Address bit 9 45 IOWR# “I/O write from host” 12 A8 Address bit 8 46 A17# Address bit 17 13 A13 Address bit 13 47 A18 Address bit 18 14 A14# Address bit 14 48 A19 Address bit 19 15 NC Not connected 49 A20 Address bit 20 16 NC Not connected 50 A21 Address bit 21 17 Vcc +5V for this IM4 51 Vcc +5V for this IM4 18 Vpp Programming supply voltage (not connected) 52 Vpp Programming supply voltage (not connected) 19 A16 Address bit 16 53 A22 Address bit 22 20 A15 Address bit 15 54 A23 Address bit 23 21 A12 Address bit 12 55 A24 Address bit 24 22 A7 Address bit 7 56 A25 Address bit 25 23 A6 Address bit 6 57 VS2# Voltage sense 2 (not connected) 24 A5 Address bit 5 58 RESET Reset from host 25 A4 Address bit 4 59 WAIT# Extend bus cycle 26 A3 Address bit 3 60 INPACK# Input port acknowledge 27 A2 Address bit 2 61 REG# Register select and I/O enable 28 A1 Address bit 1 62 SPKR# Audio digital waveform 29 A0 Address bit 0 63 STSCHG# Card status changed 30 D0 Data bit 0 64 D8 Data bit 8 31 D1 Data bit 1 65 D9 Data bit 9 32 D2 Data bit 2 66 D10 Data bit 10 33 WP/IOIS16# Write protect in Memory mode. I/O port is 16-bit in I/O mode 67 CD2# Card detect 2 (GND) 34 GND Ground Vss 68 GND Ground Vss IM4 Module Integration Guide 11 Configuring the IM4 as a Serial Module Configuring the IM4 as a Serial Module In Serial mode, the IM4 interface provides two 16C850 UART channels, an SPI channel, eight auxiliary inputs, and eight auxiliary outputs. It appears as a serial port and you can use a communications program, such as HyperTerminal, to communicate with it using the Basic Reader Interface (BRI). For more information on the BRI, see the Basic Reader Interface (BRI) Programmer’s Reference Guide (P/N 937-000-001). All signals are 3.3 V logic levels (5 V tolerant inputs). Low High Notes Inputs 0 V to 0.8 V 2.4 V to 5.5 V Input current is ±10 µA max Outputs 0.4 V Max @ 8 mA 2.9 V min @ -8 mA Note: Pins with a # in the pin name indicate an active low signal. Pins 7 (NC), 44 (IORD#), and 45 (IOWR#) determine if the IM4 operates in PC Card mode or in Serial mode. If the three signals are grounded, the IM4 operates as a serial module. These pins are carryovers from the PC card interface. These signals are mutually exclusive for any PC card application. In order for the IM4 to operate in Serial mode, you must ground all three of these signals. This condition keeps the card from driving signals defined for serial operation into a regular PC card socket. Use these notes with the Serial Module Pinouts table on the next page. You must use software to enable SPI channel. Until you enable this channel, inputs to it are ignored and outputs to it are 3-stated. The Debug signals are intended for use during any debug efforts. You can also configure these signals for use as a second UART channel. The Auxiliary outputs are 3-stated on power-up until they are written to the first time. During this condition, you should provide pullups or pulldowns to keep any external logic disabled. 12 IM4 Module Integration Guide Configuring the IM4 as a Serial Module Serial Module Pinouts Pin No. Pin Name GND SPI_SCLK SPI_DO TXD RTS# Definition Pin No. Pin Name Definition Ground Vss 35 GND Ground Vss SPI clock out of IM4 36 CD1# SPI data out of IM4 37 AUX-OUT 3 User output 3 Transmit to host 38 AUX-OUT 4 User output 4 AUX-OUT 5 User output 5 User output 6 User output 7 Request to send to host 39 Card detect 1 (GND) DTR# Data terminal ready to host 40 AUX-OUT 6 NC Not connected 41 AUX-OUT 7 Debug RXD Serial debug into IM4 42 NC Not connected NC Not connected 43 NC Not connected ‘1’ = RS232, ‘0’ = IrDA 44 IORD# “I/O read from host” Debug clear to send 45 IOWR# “I/O write from host” 10 IrDA_L 11 Debug CTS# 12 NC Not connected 46 RI# Ring indicator from host 13 RXD Receive from host 47 AUX-IN 0 User input 0 14 CTS# Clear to send from host 48 AUX-IN 1 User input 1 15 NC Not connected 49 AUX-IN 2 User input 2 16 NC Not connected 50 AUX-IN 3 User input 3 17 Vcc +5V for this IM4 51 Vcc +5V for this IM4 18 NC Not connected 52 NC Not connected 19 CD# Carrier detect from host 53 AUX-IN 4 User input 4 20 DSR# Data set ready from host 54 AUX-IN 5 User input 5 SPI data into IM4 55 AUX-IN 6 User input 6 21 SPI_DI 22 NC Not connected 56 AUX-IN 7 User input 7 23 NC Not connected 57 NC Not connected 24 NC Not connected 58 RESET# Reset_L to/from IM4/host (open drain) 25 NC Not connected 59 NC Not connected 26 NC Not connected 60 NC Not connected 27 NC Not connected 61 NC Not connected 28 NC Not connected 62 NC Not connected 29 NC Not connected 63 NC 30 Debug TXD Serial debug data from IM4 64 AUX-OUT 0 User output 0 AUX-OUT 1 User output 1 AUX-OUT 2 User output 2 31 Debug RTS# Debug request to send SPI enable out 65 66 Not connected 32 SPI_ENB# 33 NC Not connected 67 CD2# Card detect 2 (GND) 34 GND Ground Vss 68 GND Ground Vss You must use software to enable an SPI channel. Until you enable this channel, inputs to it are ignored and outputs to it are 3-stated. The Debug signals are intended for use during any debug efforts. You can also configure these signals for use as a second UART channel. The Auxiliary outputs are 3-stated on power-up until they are written to the first time. During this condition, you should provide pullups or pulldowns to keep any external logic disabled. IM4 Module Integration Guide 13 How the IM4 Operates How the IM4 Operates Overtemperature Mode Standard Mode IM4 is in Sleep mode Did the IM4 receive a request for a tag operation from an application? Application checks reason for failed status and returns overtemperature condition. No The IM4's ability to return to normal status depends on the ability of the card to dissipate the heat. Yes IM4 API returns "Status=Failed." The IM4 is designed to operate at 1 Watt of continuous power between -20˚C and 55˚C (-4˚F to 131˚F). These limits are not user programmable. Is the IM4 temperature within normal limits? No Yes IM4 API returns "Status=Normal" and data, if found. This flow chart illustrates how the IM4 operates in Overtemperature mode and in Standard mode. Heat Dissipation Requirements In most usage scenarios, the IM4 uses a maximum of 4.5 W of power from its host device. Since its RF transmit power is 1 W, it needs to dissipate up to 3.5 W of heat. Normally, the host naturally dissipates this heat. However, under high ambient temperature conditions or in a high duty cycle application, this heat may need to be conducted outside the host to prevent the IM4 from entering Overtemperature mode. The IM4 has a built-in Overtemperature mode that will sufficiently protect it against very high temperatures. When it enters Overtemperature mode, it shuts down until it is cool enough to continue operating. 14 IM4 Module Integration Guide Power Requirements In the IM4, heat is transferred to the back side (non-label side) of its case. Any heat transfer mechanism (such as moving air, a metal heatsink, a heat pipe, etc.) that is applied to this surface will help this dissipate the heat. You should keep the IM4 temperature below 65°C (149°F). Power Requirements The PC card slot must be able to supply enough power for the IM4, which is approximately 900 mA. Note that most laptop PC card slots do not supply this much power. Antenna Requirements Government regulatory agencies require that the IM4 only use approved antennas. Do not use antennas not approved for use with this module. Failure to use Intermec-approved antennas may require your system to be approved by the appropriate regulatory agencies for the countries in which your devices are being used. Using an unauthorized antenna or other peripheral device may result in possible communications interference or radio safety hazards. The antenna receptacle is an MMCX connector (50 ohm, coaxial). Once the IM4 is installed in a device, the device must not be co-located or operating in conjunction with any other antenna without regulatory agency approval. Co-location of antennas operating within 20 cm (7.9 in.) of each other requires co-location authorization. The next two tables list the Intermec-approved antennas for use in the U.S.A. and in Canada. The antenna safe distances for all antennas (869 MHz and 915 MHz) is 20 cm (7.9 in.) The cable length measurement is for antennas with an attached cable and is included in gain measurement. The cable loss measurement is for the cable that connects the antenna to the device. IM4—Intermec-Approved 869 MHz RFID Antennas Intermec Part Number Description Cable Loss Dimensions 805-616-003 Patch, Circular-Polarized, 0 dBi, 2.5”, MMCX N/A 7.9 cm x 7.9 cm x 0.6 cm (3.1 in. x 3.1 in. x 0.25 in.) 805-623-001 Patch, Circular-Polarized, 5.0 dBi, N 2.2 dB 25.9 cm x 39.1 cm x 5.8 cm (10.2 in. x 15.4 in. x 2.3 in.) 805-626-002 Patch, Linear-Polarized, 6.0 dBi, N 2.2 dB 15.5 cm x 34.0 cm x 4.8 cm (6.1 in. x 13.4 in. x 1.9 in.) IM4 Module Integration Guide 15 Antenna Requirements IM4—Intermec-Approved 915 MHz RFID Antennas Intermec Part Number Description Cable Loss Dimensions 805-591-001 Patch, Circular-Polarized, 2.0 dBi, 48”, MMCX N/A 19.3 cm x 19.3 cm x 2.5 cm (7.6 in. x 7.6 in. x 1.0 in.) 805-609-001 Patch, Circular-Polarized, 4.0 dBi, 156”, SMA(RP) N/A 25.9 cm x 25.9 cm x 3.8 cm (10.2 in. x 10.2 in. x 1.5 in.) 805-610-001 Patch, Linear-Polarized, 8.0 dBi, 60”, N(RP) N/A 21.8 cm x 19.8 cm x 5.8 cm (8.6 in. x 7.8 in. x 2.3 in.) 805-616-002 Patch, Circular-Polarized, 0 dBi, 2.5”, MMCX N/A 7.9 cm x 7.9 cm x 0.6 cm (3.1 in. x 3.1 in. x 0.25 in.) 805-622-002 Patch, Circular-Polarized, 6.5 dBi, N(RP) 2.4 dB 25.9 cm x 63.5 cm x 5.8 cm (10.2 in. x 25 in. x 2.3 in.) 805-623-002 Patch, Circular-Polarized, 5.5 dBi, N(RP) 2.4 dB 25.9 cm x 39.1 cm x 5.8 cm (10.2 in. x 15.4 in. x 2.3 in.) 805-626-001 Patch, Linear-Polarized, 6.0 dBi, N(RP) 2.4 dB 15.5 cm x 34.0 cm x 4.8 cm (6.1 in. x 13.4 in. x 1.9 in.) 805-629-001 Patch, Circular-Polarized, 7.0 dBi, N(RP) 2.4 dB 31.2 cm x 31.2 cm x 8.9 cm (12.3 in. x 12.3 in. x 3.5 in.) A270001-02 Log, Linear-Polarized, 7.0 dBi, N(RP) 2.4 dB 27.9 cm x 12.7 cm x 21.6 cm (11 in. x 5 in. x 8.5 in.) Intermec has partnered with Kathrein, formerly known as Scala, to provide antennas for the IM4. Kathrein supports the RFID industry with special antenna products for various RFID applications. For antenna integration support, contact: Kathrein Inc., Scala Division Attention: Dan Fowler P.O. Box 4580 Medford, OR 97501 U.S.A. Tel: 541-779-6500 Cell: 541-840-9889 Fax: 541-779-3991 e-mail: dfowler@kathrein.com Web: www.kathrein-scala.com 16 IM4 Module Integration Guide Specifications Specifications General Specifications Physical description PCMCIA Type II card Weight 34.0 ±2.8 g (1.2 oz ±0.2 oz) Temperature Operating: -20°C to 55°C (-4°F to 131°F) Storage: -40°C to +70°C (-40°F to 158°F) Humidity (Operating Temperature) 0-95% relative humidity, non-condensing process Transceiver Specifications Frequency range Europe (Future): 865.6 to 867.6 MHz hopping Europe (Current): 869.525 fixed U.S.A.: 902 to 928 MHz hopping Data rates 32 Kbps Modulation AM, OOK Coding Manchester: from reader to tag FM0: from tag to reader RF output impedance 50 Ω with better than 10 dB return loss Dwell time 50 mS Bus interface PCMCIA or ASCII serial (16C650 serial port) Air Interface protocol ISO 18000-6b, ISO 18000-6c, EPC Gen 1 – Class 1, EPS Gen 2 – Class 1, Intellitag FCC Compliant to Part 15 Power Supply Specifications Operating voltage Minimum: 4.5V Maximum: 5.5V On IM4, digital regulated to 3.3V Standby current Typical: 2 mA Maximum: 5 mA Read current Typical: 800 mA Maximum: 960 mA Tx circuits, Rx circuits, VCO, temperature sensor Ripple Maximum: 100 mV Peak-to-peak Timing Standby to active Channel switching IM4 Module Integration Guide Typical 1.5 mS; Maximum: 2 mS Internal time not seen by the host Maximum: 30 µS Tx on a channel to Tx on any other channel 17 Specifications Transmitter Specifications Power output (at the antenna connector— assume 0.3 dB of cable loss) Minimum: 588 mW Typical: 800 mW Maximum: 1000 mW Frequency stability Minimum: -30 PPM Maximum: 30 PPM Phase noise -60 dBc/Hz @ 30 kHz from carrier Spurious emissions -55 dBc in band Overtemperature shutdown temperature 70°C (158°F) as measured on the power amplifier 6001 36th Avenue West Everett, Washington 98203 U.S.A. tel 425.348.2600 fax 425.355.9551 www.intermec.com © 2005 Intermec Technologies Corporation. All rights reserved. IM4 Module Integration Guide *944-623-001* P/N 944-623-001
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 18 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:bd9547ad-4d6b-4367-be4c-07639bb19e96 Producer : Acrobat Distiller 6.0.1 (Windows) Create Date : 2005:10:13 14:26:33-07:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2005:10:13 14:27:12-07:00 Metadata Date : 2005:10:13 14:27:12-07:00 Document ID : uuid:13d10b5a-1b12-4c1b-97ed-0f3b9a396728 Format : application/pdf Creator : MFisher Title : Microsoft Word - IM4 Integration Guide.doc Author : MFisherEXIF Metadata provided by EXIF.tools