Intermec Technologies RFID915IM5 Intellitag RFID Radio User Manual IM5 Module QSG

Intermec Technologies Corporation Intellitag RFID Radio IM5 Module QSG

Users Manual

Download: Intermec Technologies RFID915IM5 Intellitag RFID Radio User Manual IM5 Module QSG
Mirror Download [FCC.gov]Intermec Technologies RFID915IM5 Intellitag RFID Radio User Manual IM5 Module QSG
Document ID615047
Application IDwBMMk9tSEAa3FWM/5UWRPQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.21kB (352684 bits)
Date Submitted2005-12-23 00:00:00
Date Available2005-12-23 00:00:00
Creation Date2005-12-06 07:07:11
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2005-12-06 07:09:05
Document TitleIM5 Module QSG
Document CreatorPScript5.dll Version 5.2
Document Author: smithles

Installation and
Quick Start Guide
IM5 Reader
Module
Packing List
Check to ensure that you receive these items:
S IntermecR IM5 Reader Module
S Compliance Statement
S Warranty Card
The IM5 RFID module is EPCglobal Gen2 certified
(86x MHz RFID frequency band).
The IM5 RFID module is EPCglobal Gen2 certified
(915 MHz RFID frequency band).
Host Communication
Host communication comes through the 9-pin female D-sub
connector. RS-232 standards are supported as ordered from the
factory or service center.
S The maximum data rate is 115.2K baud, with 8 data bits, no
parity bit, and 1 stop bit.
S The maximum RS-232 distance from the reader to the host,
modem, or other physical controller interface is 50 feet (15.2
meters).
RS-232 Connections
Pin Number
Definition
TXD (Transmit Data) to the host
RXD (Receive Data) from the host
Ground
CTS (Clear to Send) from the host
RTS (Request to Send) to the host
IM5 Reader Module Installation and Quick Start Guide
Power Requirements
Power comes in from 8 to 10 volts DC. Your 915 MHz Reader
uses less than 2.4 amps. Intermec supplies 9 volts DC at 2.4
amps from Intermec power supply, p/n: 851-067-001.
User I/O
A general purpose I/O (Input/Output) connector provides signal lines in and out of the reader allowing monitoring and/or
control of external devices or functions.
The connector for this is a 13-pin female circular DIN. The
mating male connector you need for mating with this is an Intermec p/n: 351-184-001.
I/O Pin-outs
Pin Number
Definition
GPIO IN0
GPIO IN1
GPIO IN2
GPIO IN3
GPIO OUT0
GPIO OUT1
GPIO OUT2
GPIO OUT3
9 through 13
Ground through individual 10 ohm
resistors
Outputs and inputs have 12 volt transient suppression devices
to ground at the connector. Output signals are driven by
2N3904 NPN transistors (low level) with a 100 kohm pull-up
to +5 volts through a silicon diode, giving about a 4.3 volt high
level. An output can be pulled high from an external source as
high as 12 volts. This will however tend to pull the other outputs higher (through two 100k resistors). The low level will be
about 0.1 volt up to about 30 mA. The output low voltage will
climb higher as the sink current increases. There is no protection
on this. You need to ensure that their load won’t require the
reader to sink more than 50 mA.
IM5 Reader Module Installat ion and Quick Start Guide
Input signals should be 0 to +1.5 volt for a low input and +3.5
to +5 volts for a high input. Each input has a 1.1 kohm resistor
in series with clamping diodes, but only about 1 µA is used until the input exceeds the 0 to +5 volt input range. There is also a
weak (100 kohm) pull-up to +5 volt on each input.
Installing the IM5 Reader Module
The IM5 Reader Module requires 8-10 volts DC at 2 amps.
The IF4 Serial Reader is powered through a 2-pin bulkhead barrel connector (Switchcraft p/n: 712A).
The Reader Module supplies 9-volt 2.4 amps to this connector.
Mating plugs for this connector are Switchcraft part numbers
760, 760K or 761K. A cable within the PSR connects the bulkhead barrel connector, via an endplate switch, to the 2-pin Molex connector on the IM5 Reader Module.
IM5 Reader module
Auxiliary I/O
Connector
Cable connector
RS-232 port
The IM5 Reader Module has holes along the sides that can be
used for mounting. For best results, attach heat sink to case via
the screwholes in the heat sink.
IM5 Reader Module Installation and Quick Start Guide
IM5 Reader module
Screw holes
Connecting and Getting Started
FCC and Industry Canada regulations limit
exposure to radio frequency (RF) radiation. To
comply with these regulations, operators of this
device must maintain a distance of at least 23 cm.
(9.1 inches) from the cover on the antenna
assembly (The cover on the antenna is the dome
shaped surface). While the device is on, the
operator’s body and parts of the body such as eyes,
hands, or head, must be 23 cm. (9.1 inches) or
farther from the cover of the antenna assembly.
FCC and Industry Canada regulations also require
that the antenna assembly of this device be
installed in accordance with the installation
procedures to allow the operator to comply with
the limit.
Only Intermec antennas and accessories have been
authorized as compliant with FCC and Industry
Canada regulations. Use of antennas and
accessories not authorized:
S may void the compliance of this product.
S may result in RF exposures beyond the limits
established for this equipment.
S require the user to re-submit their product for
compliance to the FCC and Canadian regulatory
agencies.
IM5 Reader Module Installat ion and Quick Start Guide
Antenna Installation
1 Connect the antenna cable to a port. The four antenna connectors have lock washers and nuts to allow for panel mounting.
2 Connect a reverse SMA terminator (Intermec p/n
345-004-001) to any port that does not have an antenna attached.
Each port must have either an antenna or a
terminator connected. Do not apply power to the
Reader unless an antenna cable or terminator is
installed on each antenna port.
Antenna ports (4)
Washers (4)
Nuts (4)
Reverse SMA
terminator
Reverse SMA Antenna cable
Reader LED Explanation
LED
Meaning
Power On
Reader communicating with host, LED flashes as data transfer
occurs.
Reader searching for tags
Reader communicating with a tag, LED flashes as transfer occurs.
IM5 Reader Module Installation and Quick Start Guide
Troubleshooting
Troubleshooting
Doesn’t Recognize Tag
1. Ensure antenna is properly connected.
2. Ensure reader is connected to your computer.
3. Ensure computer is plugged into AC outlet and computer is On.
4. Ensure tag is within range of antenna.
5. Call Intermec Technical Support 1-800-755-5505 (option 2).
Product Specifications
Dependent upon operating conditions and demands expected. If
used in a normal office environment with good read conditions,
you could expect to read up to 60 tags per second. Tags located
too far away or in poor locations, with respect to interfering
objects, provides poor results.
Firmware Architecture
Firmware
Spec Detail
Protocol/Compatibility
Communicates in three modes: Application Peripheral Interface (API)
and Basic Reader Interface (BRI).
General Specifications
Receiver
Spec Detail
Protocol
ISO 180006B
Tag data rates
40 kbps
Transmitter
Spec Detail
Protocol
Intellitag and EPC Gen2
Transmitter type
On/Off Keying
Frequency stability
<± 100 ppm from -25° to +55°C
RF Antenna Connections
Spec Detail
Number of antennas
up to 4, electronically switched
Antenna port isolation
≥22 dB
Physical Specifications
Spec Detail
IM5 Reader Module Installat ion and Quick Start Guide
General Specifications (continued)
Physical Specifications
Spec Detail
Size
8.25 in. x 5.30 in. x 2.9 in.
Weight
38.4 oz. (1.1 kg)
Frequency reference Source
Spec Detail
Frequency of operation
902-928 MHz
Usable channels
51
Transmitter
Spec Detail
Output power
1.00 Watt maximum
Occupied frequency bandwidth
<250 KHz
Environmental Specifications
Temperature
Spec Detail
Operating
-4°F to +131°F (-20°C to +55°C)
Storage
-31°F to +158°F (-35°C to +70°C)
Humidity
Spec Detail
Operating
95% Relative
Overall Performance
Dispatch Rates
Spec Detail
RFID tag identification rate
60 tags per second
RFID tag data exchange rates
Read a tag containing 8 bytes of data
within 12 mS.
Perform a verified write to a tag at an
average rate of 31 mS per byte per
tag.
Write Range
Spec Detail
Write range
Distances up to 70% of the read distance under the same conditions.
IM5 Reader Module Installation and Quick Start Guide
Reliability
Safety and Regulatory Approvals
Spec Detail
Reader module
UL 60950-1-UL Recognized
Component.
Electromagnetic Compatibility
Spec Detail
Reader Module
EN55022 (CISPR 22) Class B
digital emissions
EN55024 Immunity
EN61000-3-2, -3 AC Power
Harmonic Emissions and Flicker
Radio Frequency Device Approval
Spec Detail
Reader Module
FCC Part 15.247
Industry Canada RSS 210
Global Services and Support
Warranty Information
To understand the warranty for your Intermec product, visit the
Intermec web site at http://www.intermec.com and click Service
& Support. The Intermec Global Sales & Service page appears.
From the Service & Support menu, move your pointer over
Support, and then click Warranty.
Web Support
Visit the Intermec web site at http://www.intermec.com to
download our current manuals in PDF format. To order printed
versions of the Intermec manuals, contact your local Intermec
representative or distributor.
Visit the Intermec technical knowledge base (Knowledge Central) at http://intermec.custhelp.com to review technical information or to request technical support for your Intermec product.
IM5 Reader Module Installat ion and Quick Start Guide
Telephone Support
These services are available from Intermec Technologies Corporation.
In the U.S.A. and Canada
call 1-800-755-5505 and
choose this option
Service
Description
Order Intermec
products
* Place an order.
* Ask about an
existing order.
1 and then choose 2
Order Intermec
media
Order printer labels
and ribbons
1 and then choose 1
Order spare parts
Order spare parts
1 or 2 and then choose 4
Technical Support
Talk to technical
support about your
Intermec products.
2 and then choose 2
Service
* Get a return
authorization
number for
authorized service
center repair.
2 and then choose 1
* Request an on-site
repair technician.
Service contracts
* Ask about an
existing contract.
* Renew a contract.
* Inquire about
repair billing or
other service
invoicing questions.
1 or 2 and then choose 3
Outside the U.S.A. and Canada, contact your local Intermec
representative. To search for your local representative, from the
Intermec web site, click Contact.
10
IM5 Reader Module Installation and Quick Start Guide
IM5 Reader Module Installat ion and Quick Start Guide
11
Corporate Headquarters
6001 36th Avenue West
Everett, Washington 98203
U.S.A.
tel 425.348.2600
fax 425.355.9551
www.intermec.com
e 2004 by Intermec Technologies Corporation. All rights reserved.
IM5 Reader Module Installation and Quick Start Guide
*962-054-121B*
P/N 962-054-121B

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 12
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:c958e641-9717-4756-b0c2-cf09c8d3a91c
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2005:12:06 07:09:05-06:00
Create Date                     : 2005:12:06 07:07:11-06:00
Metadata Date                   : 2005:12:06 07:09:05-06:00
Document ID                     : uuid:a1ffabab-6952-4cfd-a886-92775d0b4710
Format                          : application/pdf
Title                           : IM5 Module QSG
Creator                         : smithles
Author                          : smithles
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EHARFID915IM5

Navigation menu