Itron 100GDLA Utility meter transceiver User Manual 100G Installation Guide draft 102808
Itron, Inc. Utility meter transceiver 100G Installation Guide draft 102808
Itron >
Contents
- 1. Users Manual p1
- 2. Users Manual p2
- 3. Users Manual p3
- 4. Users Manual p4
Users Manual p1
Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Revision B5 !"#$!%&'!(&)*%#"+*,(& Identification& -*$&.+$/0"&1*#,"+,2&*,&1/"/$(&& &&&3!$"&,#45/$6&3789:;::9::<&&&&=/>+(+*,&8?&&&&<<@:A& B=C&3!$"& #45/$(6&B='9?:::9::/$&!,M&0!,,*"&5/&(L+OO/M&5P&!+$J&K%%&O$*M#0"&$/"#$,(&4#("&5/&(L+OO/M&5P&2$*#,M&"$!,(O*$"!"+*,J& Modification and Repairs& C*&/,(#$/&(P("/4&O/$-*$4!,0/D&"L+(&M/>+0/&!,M&!,"/,,!&(L!%%&,*"&5/&0L!,2/M&*$&4*M+-+/M&Q+"L*#"&"L/&/]O$/((/M&!OO$*>!%&*-&I"$*,J&K,P,!#"L*$+_/M&4*M+-+0!"+*,&Q+%%&>*+M&"L/(/$`(& !#"L*$+"P&"*&*O/$!"/&"L/&/T#+O4/,"J& Warning Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void any maintenance contract with your company. Warning Follow these procedures to avoid injury to yourself or others. The lithium battery may cause a fire or chemical burn if it is not disposed of properly. Do not recharge, disassemble, heat, or incinerate the lithium battery. Keep the lithium battery away from children. Contents Chapter 1 Introduction ................................................................................................. 1 Transmission Modes ........................................................................................................................... 1 Specifications ...................................................................................................................................... 2 Meter Compatibility.............................................................................................................................. 2 Chapter 2 American Meter Installation........................................................................ 9 Installation Prerequisites ..................................................................................................................... 9 Materials Supplied By Itron ....................................................................................................... 9 Materials Supplied By You........................................................................................................ 9 Replacement Screws....................................................................................................10 Preinstallation Preparations ....................................................................................................10 Installing the 100G ERT Module .......................................................................................................10 Remove the Index ...................................................................................................................10 Assemble the ERT Module .....................................................................................................13 Program the ERT Module .......................................................................................................18 Attach the ERT Module to the Meter ......................................................................................20 Chapter 3 Sensus Meter Installation .........................................................................25 Installation Prerequisites ...................................................................................................................25 Materials Supplied By Itron .....................................................................................................25 Materials Supplied By You......................................................................................................26 Replacement Screws....................................................................................................26 Preinstallation Preparations ....................................................................................................26 Installing the 100G ERT Module .......................................................................................................27 Remove the Index ...................................................................................................................27 Assemble the ERT Module .....................................................................................................29 Program the ERT ....................................................................................................................31 Attach the ERT to the Meter ...................................................................................................33 Chapter 4 Actaris Meter Installation..........................................................................37 Installation Prerequisites ...................................................................................................................37 Materials Supplied By Itron .....................................................................................................37 Materials Supplied By You......................................................................................................38 Replacement Screws....................................................................................................38 Preinstallation Preparations ....................................................................................................38 Installing the 100G ERT Module .......................................................................................................39 Remove the Index ...................................................................................................................39 Assemble the ERT Module .....................................................................................................41 Program the ERT ....................................................................................................................43 Attach the 100G ERT Module to the Meter.............................................................................45 Attaching the 100G ERT Module to Flat-faced Model 1A Meters...........................................46 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters iii Contents Chapter 5 National/Lancaster Meter Installation......................................................51 Index Compatibility ............................................................................................................................51 Installation Prerequisites ...................................................................................................................51 Materials Supplied By Itron .....................................................................................................51 Materials Supplied By You......................................................................................................52 Replacement Screws....................................................................................................52 Preinstallation Preparations ..............................................................................................................52 Installing the 100G ERT Module .......................................................................................................53 Program the ERT ....................................................................................................................58 Chapter 6 American/Actaris Commercial Meter Installation ...................................61 Installation Prerequisites ...................................................................................................................61 Materials Supplied by Itron .....................................................................................................62 Materials Supplied By You......................................................................................................62 Replacement Screws....................................................................................................62 Preinstallation Preparations ....................................................................................................62 Installing the 100G ERT Module .......................................................................................................63 Program the ERT ....................................................................................................................67 Installing 100G ERT Module on Actaris ............................................................................................73 Installing 100G ERT Module on ROOTS Rotary...............................................................................76 Chapter 7 Sensus Commercial Meter Installation....................................................79 Installation Prerequisites ...................................................................................................................79 Materials Supplied by Itron .....................................................................................................80 Materials Supplied By You......................................................................................................80 Replacement Screws....................................................................................................80 Preinstallation Preparations ....................................................................................................80 Installing the 100G ERT Module .......................................................................................................81 Program the ERT ....................................................................................................................82 Installing 100G ERT Module on ROOTS Rotary...............................................................................87 iv Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters CHAPTER 1 Introduction The 100G is Itron's latest gas encoder-receiver-transmitter (ERT®) module. ERT modules are radio-frequency (RF) devices that transmit meter data. The RF meter data can be received by a reading device that is within transmission distance of the ERT. Itron's 100G ERT module has increased output power over legacy gas ERT modules for increased RF transmission distance. This guide covers 100G ERT Module installation on meters from a variety of manufacturers. Refer to the Meter Compatibility List to ensure you have a meter compatible with the 100G ERT Module. See the Meter Compatibility List on page 2. Transmission Modes Once installed, the 100G ERT module has three available transmission modes: Fixed Network Mode In this mode, a 100G ERT module transmits a high-powered RF message every 60 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life is 20 years. Mobile and Handheld Mode In this mode, a 100G ERT module transmits a medium-powered RF message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is 20 years. (Optional) Hard to Read Mobile and Handheld Mode In this mode, a 100G ERT module transmits a high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life decreases to 15 years in this mode, however. The Hard to Read Mobile and Handheld Mode should only be used for 100G ERT modules that are difficult to read under normal conditions, such as modules installed on roof tops or in sub-basements. An FCC license is not required to read 100G ERT modules. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Chapter 1 Introduction Specifications The functional and operational specifications for the 100G are listed below. Functional Specifications Description Power Source Two "A" cell lithium batteries Tamper Detection Tilt tamper and magnetic tamper FCC Compliance Part 15 certified Industry Canada Compliance RSS-210 certified Intrinsically Safe per UL Class I, Division 1, Groups C and D Product Identification Numeric and barcoded ERT module type and serial number Construction Materials Gray polycarbonate housing and back plate with encapsulated electronics Operational Specifications Description Operating Temperatures -40° to 158° F (-40° to +70° C) Operating Humidity 5 to 95 percent relative humidity Program Frequency 908 MHz Transmit Frequency Spread spectrum 908 to 924 MHz ISM band Data Integrity Verified in every data message Meter Compatibility The following meters are compatible with the 100G. Due to continuous research, product improvements, and enhancements, Itron reserves the right to change this list at any time. NOTE On rare occasions the location of ERT-to-meter mounting holes on older diaphragm gas meters might not match up with the mounting holes on the 100G ERT Module. This can prevent the 100G ERT Module from properly mounting to the meter. To ensure you have the latest Meter Compatibility list available, contact your Itron representative. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Meter Compatibility Mfg. Model American/ Canadian W75AL American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian Desc AL-175 Class Comments ERT Type ERT Part No. Residential Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 Aluminum case meters only 100G ERG-5000-001 100G Datalogging ERG-5002-001 100G ERG-5000-001 100G Datalogging ERG-5002-001 Residential AC-175 Residential AT-175 Residential ALC175 Residential AT-210 Residential AL-225 Canada only AL-250 Residential AR-250 Residential AC-250 Residential AT-250 Residential AM-250 Residential AL-310 Residential AL-350 Residential AT-350 Residential AL-425 Residential AC-630 5B 225 Residential Residential Aluminum case Residential 35B Iron case Commercial 100G ERG-5000-007 60B Iron case Commercial 100G ERG-5000-007 80B Iron case Commercial 100G ERG-5000-007 250B Iron case Commercial 100G ERG-5000-007 Must have front reading index. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Chapter 1 Introduction American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian American/ Canadian 500B Iron case Commercial Commercial Aluminum case meters only 100G ERG-5000-007 AL1000 Commercial Aluminum case meters only 100G ERG-5000-007 AL1400 Commercial Aluminum case meters only 100G ERG-5000-007 AL2300 Commercial Aluminum case meters only 100G ERG-5000-007 AL3000 Commercial Aluminum case meters only 100G ERG-5000-007 AL5000 Commercial Aluminum case meters only 100G ERG-5000-007 Residential Compatible with 2 foot drive index; 1 foot drive has 24 teeth and is not compatible. 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-004 100G Datalogging ERG-5002-004 100G ERG-5000-004 100G Datalogging ERG-5002-004 100G ERG-5000-004 100G Datalogging ERG-5002-004 11 Tooth Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell RT-200 RT-230 R-275 RT-275 R-315 250 11 Tooth 11 Tooth 11 Tooth 11 Tooth 11 Tooth 11 Tooth 11 Tooth Residential Residential Residential Residential Residential Residential Sensus/Invensys/ Equimeter/Rockwell S-110 11 Tooth Residential Sensus/Invensys/ Equimeter/Rockwell S-200 11 Tooth Residential Sensus/Invensys/ Equimeter/Rockwell S-175 RT-100 S-190 11 Tooth Residential 310 Sensus/Invensys/ Equimeter/Rockwell R-200 Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell ERG-5000-007 AL800 R-175 Sensus/Invensys/ Equimeter/Rockwell 100G 18 Tooth 18 Tooth 18 Tooth Residential Residential Residential Residential 24- or 30-tooth gears are not compatible Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Meter Compatibility Sensus/Invensys/ Equimeter/Rockwell S-120 Sensus/Invensys/ Equimeter/Rockwell T-120 Sensus/Invensys/ Equimeter/Rockwell T-110 R-415 11 Tooth 11 Tooth 11 Tooth 18 Tooth Residential Residential Residential Residential Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell Sensus/Invensys/ Equimeter/Rockwell RT-360 MR8 18 Tooth 16 Tooth Older meters may have ERTto-meter mounting hole variations that can make them incompatible. Residential Residential (R-275 Metric) MR12 (R-415 Metric) 16 Tooth Residential 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-002 100G Datalogging ERG-5002-002 100G ERG-5000-004 100G Datalogging ERG-5002-004 100G ERG-5000-004 100G Datalogging ERG-5002-004 100G ERG-5000-003 100G Datalogging ERG-5002-003 100G ERG-5000-003 100G Datalogging ERG-5002-003 Sensus/Invensys/ Equimeter/Rockwell 750 Commercial 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 1000 Commercial 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 1600 Commercial 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 3000 Commercial Vertical index only 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 5000 Commercial Vertical index only 100G ERG-5000-008 Sensus/Invensys/ Equimeter/Rockwell 10000 Commercial Vertical index only 100G ERG-5000-008 National/ Lancaster 175 Residential Sprague/Schlum berger/ Actaris Direct Read indexes cannot be used 100G ERG-5000-006 National/ Lancaster U175 UL175 Residential Sprague/Schlum berger/ Actaris Direct Read indexes cannot be used 100G ERG-5000-006 National/ Lancaster 250 Residential Sprague/Schlum berger/ Actaris Direct Read indexes cannot be used 100G ERG-5000-006 Schlumberger/ Sprague 175 3 Hole index box Residential Index boxes with 3 mounting holes 100G ERG-5000-005 Schlumberger/ Sprague 175 WC 3 Hole index box Residential Index boxes with 3 mounting holes 100G ERG-5000-005 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Chapter 1 Introduction 3 Hole index box Residential Schlumberger/ Sprague 175 Combination Schlumberger/ Sprague 210 Schlumberger/ Sprague 240 Schlumberger/ Sprague 240 Combination Residential Schlumberger/ Sprague 240 Residential Schlumberger/ Sprague 240 Schlumberger/ Sprague 240 Schlumberger/ Sprague 250 Residential Schlumberger/ Sprague 250 WC Residential Schlumberger/ Sprague 250 Combination Residential Schlumberger/ Sprague 1A Actaris/ Schlumberger METRI S 250 Index boxes with 3 mounting holes Residential Canadian Version of 250 Residential 2 Hole cover Residential 3 Hole Index Box ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 + Residential 1 Hole cover flat face Flat face 100G Residential Residential Requires Itron 1A Adapter P/N CFG-0015001Kit Requires Itron 1A adapter kit, CFG-0015-001 Index boxes with 3 mounting holes CFG-0015-001 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 + CFG-0015-001 100G ERG-5000-005 100G ERG-5000-005 100G ERG-5000-005 Slant-faced Schlumberger/ Sprague 400 Actaris/ Schlumberger 400A Residential Residential Slant-faced Slant-faced Actaris/ Schlumberger 675A Commercial Requires Actaris adapter p/n 80005901; purchase from Actaris 100G ERG-5000-007 Actaris/ Schlumberger 800A Commercial Requires Actaris adapter p/n 80005901; purchase from Actaris 100G ERG-5000-007 Actaris/ Schlumberger 1000A Commercial Requires Actaris adapter p/n 80005901; purchase from Actaris 100G ERG-5000-007 EMCO #2 1/2 Commercial 100G ERG-5000-008 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Meter Compatibility EMCO #3 Commercial 100G ERG-5000-008 EMCO #4 Commercial 100G ERG-5000-008 EMCO #4 1/2 Commercial 100G ERG-5000-008 EMCO #5 Commercial 100G ERG-5000-008 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Chapter 1 Introduction Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters CHAPTER 2 American Meter Installation This chapter shows you how to install a 100G ERT Module on an American Meter. Installation Prerequisites The following items are required to install the Itron 100G ERT Module. Materials Supplied By Itron The following items are supplied by Itron: 100G ERT Module New tamper seals Materials Supplied By You The following tools are required to install, initialize, and check the 100G ERT Module on the meter. Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten index and index-cover screws. Side-cutting plier/wire snips Used for cutting wire seals, if necessary. Small putty knife Used to remove all traces of old gaskets from the meter. Meter seals, wire seals, and seal press Used to secure the meter from tampering, if necessary. 11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs over screw holes. Replacement screws Used to mount 100G ERT Module assembly to meter and index to module assembly backplates. FC200SR with EndPoint-Link or EndPoint-Link Pro software Used to program and check ERT assembly. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Chapter 2 American Meter Installation Replacement Screws Replacement screws used in this procedure include: For mounting the 100G ERT Module assembly on the meter: Use 1/4 - 20 x 5/8-inch slotted, Fillister head screws. For mounting the index on the 100G ERT Module backplate: Use 8 - 32 x 3/16-inch slotted, round head screws. Pre-installation Preparations Before installing the 100G ERT Module on a meter, verify: All Itron 100G ERT Module gas modules are compatible with your brand of gas meter. See the Meter Compatibility List for compatible meter model numbers for the 100G ERT Module Installing the 100G ERT Module There are four steps to installing the 100G ERT Module on a meter: Remove the index Assemble the 100G ERT Module Program the 100G ERT Module Attach the 100G ERT Module to the meter. NOTE Properly dispose of all unused screws, old index covers, gaskets, tamper seals, and other left over materials. Do not leave any materials on customer premises. Remove the Index The first step to install a 100G ERT Module on the meter is to remove the index from the meter. To remove the index 1. Remove any tamper seals from the meter. 10 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module 2. Detach the index cover from the meter by removing the four screws holding it in place. 3. Examine the index cover screws you removed. Verify they are 5/8-inch long and not corroded. If the screws are 5/8-inch long, and are not corroded, retain for later use. If the screws are an incorrect length or corroded, dispose of them properly. Use 1/4 - 20 x 5/8-inch screws as described in Replacement Screws on page 10. TIP You can use the index cover you just removed as a temporary storage location for screws. NOTE Dispose of the index cover properly when finished with the installation procedure. Do not leave it on customer premises. 4. Unscrew one index mounting screw completely. Hold one hand beneath the index to catch the screw when it falls out of the index assembly. If it does not fall out by itself, be sure to remove it. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 11 Chapter 2 American Meter Installation 5. Unscrew the other index mounting screw. While removing this screw, pull the index away from the meter to keep its backplate (1) against the back of the screwhead (2). This prevents the screw from falling out prematurely. 6. Remove the screw from the index once it is completely free of its hole. 7. Set the index aside for the moment. Place it where it will not be damaged; get filled with dirt, rain, or snow; or fall to the ground or floor. The index will be used later in this procedure. 8. Examine the index screws you just removed. Verify that they are 3/16-inch long and are not corroded. If the screws are 3/16-inch long and are not corroded, keep them for later use. If the screws are an incorrect length or are corroded, dispose of them properly. Use 8 - 32 x 3/16-inch screws as described in Replacement Screws on page 10 instead. 9. Use a putty knife or similar object to completely remove the old index gasket from the meter (if applicable). All traces of the gasket must be removed before the ERT can be installed. 12 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module Assemble the ERT Module The next step in the 100G ERT Module installation is to create the endpoint module assembly by attaching the endpoint backplate and cover to the meter index. To assemble the ERT module 1. Hold the new 100G ERT Module. 2. Separate the ERT module backplate from the cover. 3. Place the new ERT index cover where it will not be damaged. The index cover must not get filled with dirt, rain, or snow; or fall to the ground or floor. The ERT index cover will be used later in this procedure. IMPORTANT Before continuing with the installation, note the following information about American Meter indexes. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 13 Chapter 2 American Meter Installation Index wrigglers on one-foot meters have drive slots. Index wrigglers on two-foot meters have drive posts. An index may have mounting screw holes. An index may have mounting screw slots. If the index has mounting screw slots, skip steps 4 and 5. Continue with step 6. If the index has mounting screw holes, perform steps 4 and 5. Skip steps 6 and 7. 14 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module 4. If the index has mounting screw holes, place an index mounting screw (1) in the righthand mounting screw hole (2). Use one 8 - 32 3/16-inch screw for this step (use an original mounting screw if it was the correct size and not corroded. Use the correct size replacement screw if required). 5. Attach the screw to the ERT backplate's right-hand index mounting post just enough to hold the screw end of the index in place. 6. If the index has mounting screw slots, screw an index mounting screw (1) one to two turns into the ERT backplate's right-hand index mounting post (2). Use one 8 - 32 x 3/16-inch screw for this step (use an original mounting screw if it was the correct size and not corroded. Use the correct size replacement screw, if required). Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 15 Chapter 2 American Meter Installation 7. Place the index mounting screw slot under the screw head. Do not tighten the screw. 8. Attach the wriggler to the index and backplate. If the index wriggler has a drive slot (1), place the backplate wriggler's drive post (2) in the index wriggler's drive slot. If the index wriggler has a drive post (1), place the index wriggler's drive post in the backplate wriggler's drive slot (2). 16 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module 9. Install and tighten the left-hand index mounting screw (for indexes with either mounting screw slots or holes). Use one 8 - 32 x 3/16-inch screw for this step (use an original mounting screw if it is the correct size and not corroded. Use the correct size replacement screw, if required). 10. Tighten the right-hand index mounting screw. Note To verify correct installation of the index to the ERT module housing, spin wriggler clockwise, then counter-clockwise (not more than one complete rotation). Wriggler should spin freely with little or no resistance. 11. Slide the ERT cover (1) over the index and backplate (2). Next, program the ERT module. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 17 Chapter 2 American Meter Installation Program the ERT Module The ERT must be programmed using the FC200SR with EndPoint-Link software. See the Endpoint-Link ERT Programming Guide (TDC-0411) for more information. IMPORTANT You must perform the following programming procedure for the ERT module to function properly. You must program the meter based on the drive rate shown on the index. Examples of 1-foot (1) and 2-foot (2) drive rates are shown. (The 0.05 cubic meter drive rate is not shown.) You must program the ERT based on the drive rate indicated on the index. 18 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module To program the ERT module 1. Using the FC200SR, program the reading of the index that was on the meter into the ERT module assembly. For initial programming, hold the FC200SR approximately 1 foot away from the 100G. For reprogramming (30 days or more past initial programming), hold the FC200SR approximately 4 to 5 feet away from the 100G. Be sure to program the 100G to the correct mode for the reading technology that will be used (for example, Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode). In Endpoint-Link Pro v5.0, you will have access to the one mode that was defined by your system administrator. During programming, the 100G ERT module is programmed to the nearest 100 cubic feet; the last two digits (the tens and units) are programmed as zeros (0). Once programming is complete, however, the ERT module assembly can be read to the nearest cubic foot. 2. Slowly turn the ERT module drive wriggler two turns in the direction indicated on the index drive rate. This lets you verify the ERT module is counting properly after assembly. IMPORTANT Do not turn the drive wriggler faster than one turn per second. 3. Read the ERT module assembly using the FC200SR. Consult the EndPoint-Link ERT Programming Guide (TDC-0411) or other applicable instructions for details on how to read an ERT. If this reading is higher than the one you programmed in step 1 above, the ERT module assembly is counting correctly. If the ERT module assembly reading is not higher than what was programmed in step 1, replace the ERT module with a new one. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 19 Chapter 2 American Meter Installation Attach the ERT Module to the Meter After the endpoint has been programmed and is reading correctly, it must be attached to the meter. Follow the steps below to do this. To Attach the ERT to the Meter 1. 5B 225 Meters Only If you are installing the ERT on a 5B 225 aluminum meter, cut 1/16-inch off each post of the ERT wriggler to prevent it from rubbing on the face of the nut that holds the wriggler in place. If you are not installing on a 5B 225 meter, continue to step 2 below. 2. Set the wriggler to the desired position for mounting the ERT module assembly to the meter. For One-Foot Meters: Align the ERT module assembly wriggler with the meter drive post (as shown below). Make sure the ERT wriggler is perpendicular to the meter drive post. 20 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 24 Producer : AFPL Ghostscript 8.53 Create Date : 2008:12:10 21:33:37 Modify Date : 2008:12:10 21:33:37 Title : 100G Installation Guide_draft_102808.pdf Creator : Adobe Acrobat 8.0 Author : randy.clarkEXIF Metadata provided by EXIF.tools