Itron 100GDLA utility meter transceiver User Manual 100G Installation Guide draft 102808
Itron, Inc. utility meter transceiver 100G Installation Guide draft 102808
Itron >
Contents
- 1. Users Manual p1
- 2. Users Manual p2
- 3. Users Manual p3
- 4. Users Manual p4
Users Manual p3
Chapter 4 Actaris Meter Installation Only two screws are required to mount the 100G ERT Module. Dispose of the extra screw properly. Do not leave it on the customer premises. 4. Press new tamper seals into place with an 11/32 nut driver, or other blunt tool. Attaching the 100G ERT Module to Flat-faced Model 1A Meters If you want to install a 100G ERT Module on a flat-faced model 1A meter you will have to use the CFG-0015-001 adapter kit. Obtain the kit from Itron then use the following procedure to install the kit and the 100G ERT Module. 1. Make sure you have all of the following items in the kit. 46 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module 2. Remove the drive dog from the meter and replace it with the one from the kit. IMPORTANT Do not use a tool to install or tighten the new drive dog, hand tighten only. 3. Attach Adapter Shim Plate to the meter, as shown, using the two index mounting screws from the kit. Apply 15 to 20 inch-pounds of torque to the screws to provide a tight seal between the shim plate and the meter. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 47 Chapter 4 Actaris Meter Installation 4. Turn the white wriggler so one of its four drive slots lines up with the drive dog. 5. Gently place the 100G ERT Module on the meter. If there is a gap between the gasket and the meter, it is probably because the drive slot of the ERT module assembly's wriggler is not properly aligned with the meter wriggler drive dog. To correct this, remove the assembly and repeat the alignment procedure in step one. 6. WARNING! If the drive slot of the 100G ERT Module wriggler is not properly aligned with the meter wriggler drive dog, there may be a gap between the gasket and the meter. To correct this, remove the assembly and repeat the alignment procedure. Failure to place the drive post into the drive slot can cause binding and lead to poor registration or meter failure. Turn each screw 1/4 to 1/2 turn after it contacts the cover. IMPORTANT Meter manufacturers should torque the mounting screws 15 to 20 inch-pounds. 48 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module Only two screws are required to mount the 100G ERT Module. Dispose of the extra screw properly. Do not leave it on the customer premises. 7. Press new tamper seals into place with an 11/32 nut driver, or other blunt tool. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 49 Chapter 4 50 Actaris Meter Installation Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters CHAPTER 5 National/Lancaster Meter Installation This chapter shows you how to install a 100G ERT Module on the 175-250 CFH National/Lancaster gas meter. Index Compatibility The 100G ERT Module for National/Lancaster meters can only be used with dial type indexes from National or Actaris/Schlumberger. Installation Prerequisites The following items are required to install the Itron 100G ERT Module. Materials Supplied By Itron The following items are supplied by Itron: 100G ERT Module New tamper seals Two screws for attaching the 100G ERT Module to the meter. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 51 Chapter 5 National/Lancaster Meter Installation Materials Supplied By You The following tools are required to install, initialize, and check the 100G ERT Module on the meter. Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten index and index-cover screws. Side-cutting plier/wire snips Used for cutting wire seals, if necessary. Small putty knife Used to remove all traces of old gaskets from the meter. Meter seals, wire seals, and seal press Used to secure the meter from tampering, if necessary. 11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs over screw holes. Replacement screws Used to mount 100G ERT Module assembly to meter and index to module assembly backplates. Replacement Screws Replacement screws used in this procedure include: For mounting 100G ERT Module assemblies on meters: Use 10-24 x 2 3/4-inch flat head, stainless steel, Phillips head screws (Itron part number SCR-0014-003). For mounting indexes on 100G ERT Module backplates by their legs: Use 6-19 x 3/8-inch thread forming, zinc-plated, Phillips head screws (Itron part number SCR-0015-001). For mounting indexes through 100G ERT Module backplate mounting holes: Use 6-19 x 3/8-inch thread forming, zinc-plated, Phillips Fillister head screws (Itron part number SCR-0037-001). Pre-installation Preparations Before installing the 100G ERT Module on a meter, verify: All Itron 100G ERT Module gas modules are compatible with your brand of gas meter. See the Meter Compatibility List for compatible meter model numbers for the 100G ERT Module 52 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module Installing the 100G ERT Module There are four steps to installing the 100G ERT Module on a meter: Remove the index Assemble the 100G ERT Module Program the 100G ERT Module Attach the 100G ERT Module to the meter. NOTE Properly dispose of all unused screws, old index covers, gaskets, tamper seals, and other left over materials. Do not leave any materials on customer premises. To remove the index The first step to install a 100G ERT Module on the meter is to remove the index from the meter. 1. Remove any tamper seals from the meter. 2. Remove the two screws and dispose of them properly. 3. Remove the index cover from the meter. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 53 Chapter 5 National/Lancaster Meter Installation 4. Remove the index mounting screws and the index from the meter. 5. Remove all traces of the old index cover gasket from the meter. The new ERT module has its own gasket. 6. Verify the meter drive dog sticks straight out from the meter. 54 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module 7. If the index has mounting legs, make sure each leg is parallel to the back of the index (as shown) to provide proper alignment between the ERT and meter. 8. Verify the index wriggler is parallel to the surface of the index. Indexes that do not have mounting legs must be attached to the ERT module’s index backplate mounting posts. Indexes that have mounting legs only, must be attached to the ERT module's index bracket mounting posts. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 55 Chapter 5 National/Lancaster Meter Installation If you are attaching the index to the 100G ERT Module using mounting legs, use Itron SCR-0015-001 screws. If you remove the two mounting legs and attach the index to the 100G ERT Module backplate mounting posts, use Itron SCR-0037-001 screws. To attach the index to the 100G ERT Module using the mounting legs 1. Get two new screws (part number SCR-0015-001) for attaching indexes to ERT modules by their legs. 2. Install an index mounting screw in the left mounting hole and tighten the screw just enough to hold it in place. 56 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module 3. Place the index’s mounting leg screw slot under the screw head and tighten the screw enough to hold the index leg in place, but loose enough so you can pivot the index around the screws. 4. Make sure the index’s right mounting leg screw slot is positioned over the ERT module’s right index mounting leg screw hole. 5. Turn each screw 1/4 to 1/2 turn after it contacts the mounting leg. To attach the index to 100G ERT Module without mounting legs 1. Get two screws (part number SCR-0037-001) to attach indexes to the ERT modules by their backplate mounting screw holes. 2. Secure the index mounting screws through the mounting screw hole in the ERT index backplate mounting post. 3. Turn each screw 1/4 to 1/2 turn after it contacts the index backplate. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 57 Chapter 5 National/Lancaster Meter Installation Program the ERT The ERT must be programmed using the FC200SR with EndPoint-Link software. See the Endpoint-Link ERT Programming Guide (TDC-0411) for more information. IMPORTANT You must perform the following programming procedure for the ERT module to function properly. To program the ERT module 1. Using the FC200SR, program the reading of the index that was on the meter into the ERT module assembly. For initial programming, hold the FC200SR approximately 1 foot away from the 100G. For reprogramming (30 days or more past initial programming), hold the FC200SR approximately 4 to 5 feet away from the 100G. Be sure to program the 100G to the correct mode for the reading technology that will be used (for example, Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode). In Endpoint-Link Pro v5.0, you will have access to the one mode that was defined by your system administrator. During programming, the 100G ERT module is programmed to the nearest 100 cubic feet; the last two digits (the tens and units) are programmed as zeros (0). Once programming is complete, however, the ERT module assembly can be read to the nearest cubic foot. 2. Slowly turn the ERT module drive wriggler two turns in the direction indicated on the index drive rate. This lets you verify the ERT module is counting properly after assembly. IMPORTANT Do not turn the drive wriggler faster than one turn per second. 3. Read the ERT module assembly using the FC200SR. Consult the EndPoint-Link ERT Programming Guide (TDC-0411) or other applicable instructions for details on how to read an ERT. If this reading is higher than the one you programmed in step 1 above, the ERT module assembly is counting correctly. If the ERT module assembly reading is not higher than what was programmed in step 1, replace the ERT module with a new one. 58 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module To attach the 100G ERT Module to the meter 1. Get two new ERT module mounting screws (part number SCR-0014-004). 2. Carefully place the ERT module assembly on the meter. Make sure the meter drive dog aligns with the white wriggler drive slot. 3. Make sure there is no gap between the 100G ERT Module and the meter. If there is a gap, the end of the meter drive dog is probably riding on the face of the ERT module wriggler drive post instead of in its drive slot. To eliminate the gap: Remove the ERT module. Repeat step 2 to align the ERT module drive dog. WARNING! If the drive slot of the 100G ERT Module wriggler is not properly aligned with the meter wriggler drive dog, there may be a gap between the gasket and the meter. To correct this, remove the assembly and repeat the alignment procedure. Failure to place the drive post into the drive slot can cause binding and lead to poor registration or meter failure. 4. Turn each screw 1/4 to 1/2 turn after it contacts the cover. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 59 Chapter 5 National/Lancaster Meter Installation 5. Install tamper seals over the screws and press them into place with an 11/32 nut driver, or some other blunt tool. 60 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters CHAPTER 6 American/Actaris Commercial Meter Installation This chapter shows you how to install a 100G ERT Module on an American Commercial meter. Before installing the 100G ERT Module, verify you have: A compatible meter shown in the Meter Compatibility List. A compatible index. Itron 100G ERT Module can be used with standard dial and direct read (odometer) indexes. The list of materials defined under Installation Prerequisites in this chapter. IMPORTANT Handle the 100G ERT Module carefully so the metal passive radiator antenna is not damaged. Installation Prerequisites The following items are required to install the Itron 100G ERT Module. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 61 Chapter 6 American/Actaris Commercial Meter Installation Materials Supplied by Itron The following items are supplied by Itron: 100G ERT Module New tamper seals Four screws for securing the 100G ERT Module assembly to the meter. These screws may have holes drilled into the heads to accept wire tamper seals. Two internal-tooth star washers for the mounting screws when using metal index plates. Two cork washers and two flat washers for the mounting screws when using plastic index covers. Materials Supplied By You You must supply the following items to install, initialize, and check the 100G ERT Module on the meter. Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten index and index-cover screws. Side-cutting plier/wire snips Used for cutting wire seals, if necessary. Meter seals, wire seals, and seal press Used to secure the meter from tampering, if necessary. 11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs over screw holes. FC200SR with EndPoint-Link or EndPoint-Link Pro software Used to program and check ERT assembly. Replacement Screws Use 12 - 24 x 1/2-inch slotted, Fillister head machine screws (drilled to accept wire seals) for replacement screws to mount the index cover. Pre-installation Preparations Before installing the 100G ERT Module on a meter, verify: All Itron 100G ERT Module gas modules are compatible with your brand of gas meter. See the Meter Compatibility List for compatible meter model numbers for the 100G ERT Module 62 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module There are two types of index mounting plates for American Commercial meters. One type is made of plastic and has tamper seal cups. The other type is made of metal and has no tamper seal cups. Similarly, there are index covers with tamper seal cups and covers without tamper seal cups. Installing the 100G ERT Module There are four major steps to installing the 100G ERT Module on a meter: Remove the index or index and cover mounting plate. In some cases you can remove the mounting plate with the index and its cover still attached to the mounting plate. Program the 100G ERT Module Attach the 100G ERT Module to the meter. NOTE Properly dispose of all unused screws, old index covers, gaskets, tamper seals, and other left over materials. Do not leave any materials on customer premises. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 63 Chapter 6 American/Actaris Commercial Meter Installation To remove the index 1. Note the orientation of the index. Remove the tamper seals or wire seals from the index cover and the mounting plate screws. For illustrative purposes in the procedure, a plastic index mounting plate with tamper seal cups was used. 2. Remove the index cover screws from the meter. Verify they are 1/2-inch long and not corroded. If the screws are the correct length and not corroded, keep them for later use. 64 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module If the screws are an incorrect length or are corroded, dispose of them properly. Use the screws listed in Replacement Screws on page 62, if necessary. 3. Remove the gasket from the index cover mounting plate and set it aside where it will not get damaged. You will use the gasket later in the installation. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 65 Chapter 6 American/Actaris Commercial Meter Installation 4. Remove the four tamper seals from the mounting plate. 5. Remove the mounting plate screws and separate the mounting plate from the meter. Set the mounting plate aside where it will not get damaged. You will use it later in the installation. 66 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module Program the ERT The ERT must be programmed using the FC200SR with EndPoint-Link software. See the Endpoint-Link ERT Programming Guide (TDC-0411) for more information. IMPORTANT You must perform the following programming procedure for the ERT module to function properly. To program the ERT module 1. Using the FC200SR, program the reading of the index that was on the meter into the ERT module assembly. For initial programming, hold the FC200SR approximately 1 foot away from the 100G. For reprogramming (30 days or more past initial programming), hold the FC200SR approximately 4 to 5 feet away from the 100G. Be sure to program the 100G to the correct mode for the reading technology that will be used (for example, Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode). In Endpoint-Link Pro v5.0, you will have access to the one mode that was defined by your system administrator. During programming, the 100G ERT module is programmed to the nearest 100 cubic feet; the last two digits (the tens and units) are programmed as zeros (0). Once programming is complete, however, the ERT module assembly can be read to the nearest cubic foot. 2. Slowly turn the ERT module drive wriggler two turns in the direction indicated on the index drive rate. This lets you verify the ERT module is counting properly after assembly. IMPORTANT Do not turn the drive wriggler faster than one turn per second. 3. Read the ERT module assembly using the FC200SR. Consult the EndPoint-Link ERT Programming Guide (TDC-0411) or other applicable instructions for details on how to read an ERT. If this reading is higher than the one you programmed in step 1 above, the ERT module assembly is counting correctly. If the ERT module assembly reading is not higher than what was programmed in step 1, replace the ERT module with a new one. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 67 Chapter 6 American/Actaris Commercial Meter Installation To attach the 100G ERT Module to the meter 1. Turn the ERT module upside down and turn the wriggler until its drive notches line up with drive teeth of the meter wriggler. IMPORTANT Handle the 100G ERT Module carefully so the metal passive radiator antenna is not damaged. 68 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters Installing the 100G ERT Module 2. Position the ERT module so its screw holes line up with the screw holes in the meter top then place the ERT module on the meter top. Make sure the INLET label on the ERT module is next to the INLET label on the meter case. 3. Carefully lower the 100G ERT Module onto the meter top so that its notches align with the teeth on the meter wriggler. Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 69 Chapter 6 American/Actaris Commercial Meter Installation 4. Make sure there is no gap between the bottom of the ERT module and the top of the meter. If there is a gap, it is because the drive notches of the ERT module's lower wriggler are not properly aligned with the meter wriggler's drive teeth. WARNING! Do not press down on the ERT module if there is a gap. If you do, you may damage the ERT module or the meter wriggler. 5. To eliminate a gap, slowly turn the ERT module upper wriggler back and forth with your fingers until the ERT module drops down onto the top of the meter. 6. Place the index cover mounting plate on the ERT module so the words "FLOW FRONT AL800 AL1000 AL1400 AL2300 AL5000 TURBINE ROTARY" are toward the front of the meter. 70 Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 25 Producer : AFPL Ghostscript 8.53 Create Date : 2008:12:10 21:38:10 Modify Date : 2008:12:10 21:38:10 Title : 100G Installation Guide_draft_102808.pdf Creator : Adobe Acrobat 8.0 Author : randy.clarkEXIF Metadata provided by EXIF.tools