Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 20  Proprietary and Confidential    Shelf Mount Installation This section  describes 100W/100W+ and 100WP/100WP+ ERT module  installation  using a shelf mount adapter to mount the ERT module in a pit lid slot.  Caution  Observe the following guidelines for mounting the ERT module using the shelf mount procedure: • ERT module positioning  other than upright could negatively  affect radio performance and battery life. • Use only Itron-approved  splice kits or inline connectors.  The pit lid and slot must have the correct dimensions for the ERT module assembly to fit properly. The following  illustration  and the accompanying  table  give  pit lid  slot dimensions  for the shelf mount installation method.   Pit Lid Slot Dimensions Dimension Minimum (inches) Maximum (inches) A  6 3/4 N/A B  2  5 3/4 C  3/4  1   Required Hardware Itron 100W Series Shelf Mount Kit  To install using the shelf mount adapter 1. With the foam spacers facing  up, insert the shelf mount adapter into the opening  in the disk.
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 21   Proprietary and Confidential     2. Push the adapter into the opening  gently  until  the adapter snaps into place. Insert the shelf mount adapter into the ERT module  antenna slot pushing  firmly with your thumb until  the adapter tab locks into place in the ERT module  antenna slot opening.    3. Slide the adapter assembly into the pit lid with the foam spacers positioned  on each side of the pit lid  slot.   Correct  position for foam spacers Caution  Do not install  the adapter assembly  in a manner that provides  little  or no support under disk's edge.     Incorrect  mounting position for foam spacers.  4. The installed  ERT module position  must be vertical  and upright  when the lid is replaced  on the pit. Caution  When placing  the pit lid  on to the pit box after the shelf mount adapter installation,  use care to avoid pinching  or damaging  the ERT module to meter cable. Any  ERT module position  other than upright may negatively  affect radio  performance and battery life.   Through Lid Installation This section  provides instructions  to mount the 100W/100W+ and 100WP/100WP+ ERT module  in a pit lid with a drilled,  round 1-3/4-inch, 1-7/8-inch, or 2-inch hole.
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 22  Proprietary and Confidential    Through Lid Mount Required Tools and Hardware This mounting  method requires the Pit Lid Mounting  Kit. Refer to the 100W Installation  Methods Overview (PUB-1300-004) for guidance  on which  kit to install  for different pit lid material  and traffic conditions. Pit Lid Mounting  Kit (CFG-1300-004)    Note  The Pit Lid Mounting  Kit is not intended for applications  involving  vehicular  traffic. Use the Remote Antenna Kit in incidental  traffic areas (such as residential  environments). This section  provides the instructions  to install  the 100W/100W+ and 100WP/100WP+ ERT module  in  a pit lid with a hole using the Pit Lid Mounting  Kit (CFG-1300-004). Verify  you have the following  items to complete  the installation.  A Retainer clip  B  Pit lid with a pre-drilled hole (simulated pit lid material shown) C  Retainer clip collar D 100W/100W+ and 100WP/100WP+ ERT module
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 23   Proprietary and Confidential     To install in lids with holes using the Pit Lid Mounting Kit (CFG-0771-011) 1. Insert the retainer  clip  into the pit lid  hole with the convex  surface on the top of the pit lid.  2. From the bottom side of the lid, screw on the threaded retainer  clip  collar  until  the beveled  top rests against the pit lid.    Note  Ensure the beveled  edge of the clip collar  is toward the top of the pit lid. 3. Align  and insert the retainer clip  tab into the retainer  clip  receptacle  on the ERT module housing.
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 24  Proprietary and Confidential    4. Verify the clip locks into place in the housing.  Caution  Carefully align the ERT module through lid assembly. If the assembly is improperly aligned, the pit lid may not close.    Pit lid mounting  installation  is complete.  Optional Leak Sensor Installation This section  describes installation  of the Leak Sensor (LS) in a 100W/100W+ and 100WP/100WP+ ERT module system. The ERT module  stores 20 days of LS data. On the 21st day, the ERT module begins  to write  over stored data in a first in, first out manner.  The ERT module  automatically  detects the presence of connected  LS devices.  The ERT module  will automatically  detect the LS within  22.5 minutes and begin  reading  LS data. To immediately  detect the LS and begin  reading  data, perform a Check ERT  with a handheld computer running FDM software. The LS is used in conjunction  with both indoor  (basement) and outdoor (mounting  on the exterior  of the house) 100W/100W+ and 100WP/100WP+ ERT module installations.  LS devices  are mounted on a water service pipe  or meter insetter (meter horn) and connect to the LS connector on the ERT module  as described in To connect the Leak Sensor to the 100W/100W+ and 100WP/100WP+ ERT module on page 26. The mounting  bracket shipped  with the LS accommodates an (up to) 1-1/2-inch OD pipe. An optional mounting bracket is available  for pipe sizes (up to 2 1/2-inch OD).
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 25   Proprietary and Confidential     Leak Sensor Installation  Equipment Equipment Itron Part Number Description Leak Sensor LDS-0001-002  LS with  inline connector, environmental  connector cap;  5-foot cable, and mounting  bolt (fits up  to 1 1/2-inch OD  pipe). Optional mounting bracket CFG-0349-002 Mounting bolt fits up to 2 1/2-inch OD pipe. ERT module 100W three-port ERT  module ERW-1300-203 Triple  port encoder ERT  module  for connection to register, Leak Sensor, and  optional remote antenna. 100W+ three-port ERT  module ERW-1300-303 Triple  port encoder ERT  module  for connection to register, Leak Sensor, and optional remote antenna, ISM  100W, 5-ft. flying  leads, two-port ERT module ERW-1300-206 Three-port encoder ERT  module for connection to register using  5-ft. flying leads, Leak Sensor and  optional remote antenna  connection with  inline connectors. 100W+, 5-ft. flying leads, two-port ERT mo dule ERW-1300-306 Thre e-port encoder ERT  module for connection to register using  5-ft. flying leads, Leak Sensor and optional remote antenna connection with  inline connectors, ISM 100W, 20-in. flying leads, three-port encoder ERT  module ERW-1300-218 Three-port encoder ERT  module for connection to register using  20-in. flying leads, Leak Sensor, and  optional remote antenna  connection with inline connectors. 100W+, 20-in. flying leads, three-port encoder ERT  module ERW-1300-318 Thre e-port encoder ERT module for connection to register using  20-in. flying leads, Leak Sensor, and  optional remote antenna  connection with inline connectors, ISM 100WP three-port ERT  module ERW-1300-209 Thre e-port pulser ERT  module for connection to register, Leak Sensor, and optional remote antenna. 100WP +three-port ERT  module ERW-1300-309 Thre e-port pulser ERT  module for connection to register, Leak Sensor, and optional remote antenna, ISM 100WP, 5-ft. flying leads, two-port ERT module ERW-1300-212 Thre e-port pulser ERT module for connection to register using  5-ft. flying leads, Leak Sensor, and optional remote antenna connection with inline connectors. 100WP+, 5-ft. flying  leads, two-port ERT module ERW-1300-312 Thre e-port pulser ERT  module for connection to register using 5-ft. flying leads, Leak Sensor, and  optional remote antenna  connection with  inline connectors, ISM 100WP, 20-in. flying leads, three-port pulser ERT  module ERW-1300-220 Three-port pulser ERT  module for connection to register using 20-in. flying leads, Leak Sensor, and optional remote antenna connection with inline connectors. 100WP+, 20-in. flying leads, three-port pulser ERT  module ERW-1300-320 Thre e-port pulser ERT module for connection to register using  20-in. flying leads, Leak Sensor, and  optional remote antenna  connection with  inline connectors, ISM 25-foot extension cable (optional) CFG-0349-101 25-foot cable with  coordinating  connectors (LS blue connector, register black connector). 100W LS  environmental replacement cap MSC-0019-008 Protects Leak Sensor connector when  the LS is not connected to the 100W ERT module. Itron Security Seal MSC-0018-001 Indicates module tampering  and ensures the protective cover stays intact.
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 26  Proprietary and Confidential                                         Leak Sensor                 Optional Mounting Bracket      3-port Module       Two-port/flying lead module  Warning  When the 100W/100W+ or 100WP/100WP+ is installed  but the LS is not attached, you must protect the blue port with the universal environmental  cap (MSC-0019-008). If you remove the LS from the ERT module,  the environmental  cap must  be replaced to protect the connector.    To connect the Leak Sensor to the 100W/100W+ and 100WP/100WP+ ERT module Caution  Verify  you have the correct 100W/100W+  or 100WP/100WP+ ERT module. Leak Sensors must mount to Port B (middle  blue port) of the ERT module. Connecting  the LS to Port A (bottom port) or Port C (top port) will  cause electrical  damage  to the LS and ERT module. 1. Remove the environmental  cap from the ERT module's blue  connector (B).  C. Red connector: Optional antenna connection B. Blue connector: Leak Sensor connection A. Black connector: register connection 2. Remove the environmental  cap from the Leak Sensor connector. Verify  the connectors (the ERT module's LS connector and the Leak Sensor connector) are clean  and dry.
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 27   Proprietary and Confidential     3. Align  the Leak Sensor connector with the ERT module's blue connector and insert.      4. Rotate the connector locking  ring  until the security holes align.    Caution  Do not force the connector ends together.  While  you hold the LS connector, engage  the ERT module's connector by rotating the locking  ring until both connectors securely  connect. Twist only the connector locking  ring,  not the body of the connector. Twisting  the connector body could damage the connector's pins.  To attach an Itron Security Seal through the connector security hole 1. Insert the pointed  end of the security seal through  the inline  connector and the ERT module  connector security holes.
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 28  Proprietary and Confidential    2. Insert the pointed  end of the security seal into the capped end and push until  the seal locks.    This completes  the ERT module and Leak Sensor connections.  Pipe Preparation Clean any dust or dirt from the pipe to facilitate  direct  contact with the LS surface.  To install the Leak Sensor on a pipe or meter insetter 1. Select a Leak Sensor mounting  location within 5-feet of the ERT module. Mount the sensor on the water input side of the meter. Caution  Mount the Leak Sensor on the water input side of the meter. Failure to follow  this mounting requirement could result in errors in the leak detection data. Installation  requires  Itron mounting  hardware. Repair costs and service charges  relating  to the use on non-compliant mounting hardware will be charged to the customer. Contract Itron Support for more information. 2. Verify  the pipe’s  mounting  surface is free from dirt and debris. Place the curved surface of the LS against the pipe.
Installing  the 100W/100W+ and 100WP/100WP+ ERT Module   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 29   Proprietary and Confidential     3. Insert the mounting  U-bolt  over the pipe and into the LS mounting  holes.     Caution  Do not mount the Leak Sensor on a pipe coupler, joint, or nut.  4. Insert the mounting  plate over the U-bolt's threaded screw ends. Attach the two wing  nuts over the clamp screw ends and tighten  the wing  nuts until  snug (to a minimum  of 5-inch pounds) to prevent device rotation  on the pipe. After you tighten  the second wing  nut, check the Leak Sensor to verify the device  is snug. If the sensor moves, tighten  the wing  nuts until there is no movement.  Caution  Do not tighten  the Leak Sensor to more than 20 inch-pounds. Over-tightening  could damage the Leak Sensor housing  and/or the pipe.                          Note  Leak Sensor mounting  orientation  is not critical.  Orient  the sensor to best accommodate your installation.  The most important installation  practice is to mount the sensor securely to the pipe.