Optional Direct Connect Remote Antenna Installation   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 38  Proprietary and Confidential    Remote antenna installation is complete.
 TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 39   Proprietary and Confidential     This section describes the 100W/100W+ and 100WP/100WP+ ERT module connections to the water meter register using the inline connector assembly. Follow the manufacturer's recommended procedure for installing the water meter register on the meter.  To connect the inline connector Note  If an inline connector is not used and the ERT module is already connected to the water meter register, skip this step. 1. Remove the protective cover from the connector by twisting the two halves in opposite directions. Pull the halves apart.    Caution  Verify the connector halves are clean and dry before assembly. If any of the following conditions occur, do not install the ERT modules:     •   Any of the three pins are damaged or missing.    •   The O-ring is missing.    •   The cable is cut or nicked. 2. Connect the register cable to the ERT module connector:  • Holding the connectors by the black shells, rotate one end to align the keyed slots. • Push until snug.  • Slide the black coupling nut over the O-ring. Make sure the O-ring stays seated. (If the O-ring does not stay seated, disconnect and repeat this step.) • Twist the register cable's black coupling nut to align the two tabs.  APPENDIX  A  Using an Inline Connector
Using an Inline Connector   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 40  Proprietary and Confidential    3. Install the security seal as shown. Push it until it snaps into place.      Note  For future meter or ERT module servicing, break the security seal by pulling the seal apart. The original protective connector covers can be reused if kept clean and dry. Install a new security seal after servicing either device. To order replacement security seals, see the Water ERT Module Ordering Guide (PUB-0063-001). Caution  Shield connectors with protective environmental covers (see 100W/100W+ and 100WP/100WP+ ERT Module Mounting Accessories on page 14). Do not leave an exposed connector in the field.  Environmental caps employ multiple seals to increase cap life. Environmental cap design allows utilities to install the ERT module and install a Leak Sensor or optional remote antenna at a future date.
 TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 41   Proprietary and Confidential     This section describes connecting the 100W/100W+ and 100WP/100WP+ ERT module with flying leads to the water meter register using the Itron Splice Kit.   Caution  ERT module wire terminations must be properly sealed with a non-conductive gel material to prevent water intrusion (otherwise, this configuration should not be used in a pit box environment). Itron recommends the 5-foot or 20-inch cable configuration for OEM users only.  Required Materials • E-9R 3M® gel cap crimping tool  • Itron Splice Kit (OEM-0034-002) • 100W/100W+ and 100WP/100WP+ ERT Module with flying leads       To install the Itron splice kit 1. Push the corresponding register and ERT module wires as far as possible into the connector.  Caution  Do not strip insulation from the ends of the wires before inserting them into the connector. APPENDIX  B  Using the Itron Splice Kit
Using the Itron Splice Kit   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 42  Proprietary and Confidential    2. Carefully place the connector and wires into the jaws of the crimping tool. Make sure the wires remain fully inserted in the gel-cap connector.  3. Crimp the connector by squeezing the handles until the connector cap is fully seated. Continue to apply pressure for three seconds.  4. A connector is crimped properly when the top of the movable yellow center (1) is flush with the top of the connector body (2).  Warning  Crimping the connector forces some sealant out of connector. The sealant protects the inside of the connector against insects, moisture, and other contaminants.  The sealant may cause minor eye and skin irritation. Avoid eye contact.  Avoid prolonged or repeated skin contact. Contact Itron Support for Material Safety Data Sheets (MSDS).
Using the Itron Splice Kit   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 43   Proprietary and Confidential     5. After you complete all ERT module to register wire connections, arrange the connectors in a single file.  6. Insert the connectors and wires into the splice tube until the connectors and wires completely immerse in the tube's gel material.   7. Separate the cables to the sides and close the splice tube cover.   8. Discard any leftover materials from the customer premises.
 TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 44   Proprietary and Confidential     This section describes the procedure for installing Itron cable armor in a field installation. The Itron armor cable provides a layer of protection for the module's cable jacket. Itron cable armor is available in 5-foot sections.  Warning  Itron armor cable is stainless steel and may have sharp edges. Use caution when you are installing the armor cable.  Important  If you remove the inline connector from the ERT module to install the armor cable, you must use an Itron handheld to reprogram the ERT module using FDM Endpoint Tools. Perform a Check Endpoint function (with in FDM Endpoint Tools) after you reprogram the ERT module to verify communication with the meter register.   Required Materials The following materials are required to install the Itron cable armor. • 5-foot Itron cable armor • Electrical tape • (Optional) Scissors       To install the Itron cable armor 1. Remove the ERT module from the pit. Note  If it is possible in your field installation, keep the ERT module connected to the register. 2. Cut a two to three inch strip of electrical tape.  APPENDIX  C  Using the Itron Cable Armor
Using the Itron Cable Armor   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 45   Proprietary and Confidential     3. Wrap the entire piece of electrical tape around the ERT module cable near the inline connector.     4. Beginning over the installed electrical tape, twist the Itron cable armor onto the ERT module cable using a right-handed twist.    Important  You must twist—not wrap—the cable armor onto the ERT module cable. Wrapping the cable armor can cause the stainless steel jacket to warp.  Warning  You must begin wrapping the cable armor over portion of the cable protected by the electrical tape. If you do not begin to wrap the cable armor over the protected portion of the ERT module cable, a cut cable could cause an ERT module/register communication failure. 5. Continue to twist the cable armor onto the ERT module cable until the cable armor covers the entire cable.   Warning  You must continue to wrap the cable armor onto the cable protected by the electrical tape. If you do not twist the cable armor over the protected portion of the cable, you cut initiate a cut cable and cause and ERT module/register communication failure. 6. Remove any leftover materials from the customer premises. Discard or recycle leftover materials.
 TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 46   Proprietary and Confidential     The following information is provided to help you troubleshoot issues related to the 100W/100W+ and 100WP/100WP+ ERT modules.  The following table describes possible issues and provides suggested actions to resolve the issue. Issue  Action Cannot program the ERT module. Check the programming device and software version. Program ERT modules using the FC300 handheld computer running Field Deployment Manager (FDM) software. Cannot read the ERT module. An ERT module that is not programmed will not transmit an SCM/SCM+. Reprogram the ERT module and perform a reread. If an ERT module is not initially programmed, it will not bubble-up and listen for an SCM/SCM+. The encoder ERT module is reporting an invalid read. An encoder ERT module that has set the Last Good Read flag will cause an Invalid Read to display in the FDM Consumption field. Marginal readability due to water ERT module location (for example, an ERT module deep inside a pit). Consider reprogramming the ERT module for Hard-to-read (H2R) mode. This increases the output power to Fixed Network levels.  Note  Hard-to-read mode will reduce battery life.  The ERT module in a Fixed Network is not reporting. Perform a Check ERT and verify the ERT module is in FN mode. If the CCU's pathway is obstructed, consider including an 8-channel repeater. Systems that utilize Fixed Network v4.0 software and a CCU100 may require a Repeater 100. The handheld programmer is locked up and button presses produce no response. Soft boot the handheld by pressing and holding buttons A and B until the screen fades. Release the buttons and allow the handheld to reboot.   APPENDIX  D  Troubleshooting
 TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 47   Proprietary and Confidential     Symbols & Numbers 100W/100W+ and 100WP/100WP+ ERT Module installation • Error! Bookmark not defined. 100W/100W+ and 100WP/100WP+ ERT Module models • Error! Bookmark not defined., Error! Bookmark not defined. 100W/100W+ and 100WP/100WP+ ERT Module transmission modes • Error! Bookmark not defined. 100W/100W+ and 100WP/100WP+ ERT Module with integral connectors • Error! Bookmark not defined. 100W/100W+ encoder start-up • Error! Bookmark not defined. 100W/100W+ operating modes • Error! Bookmark not defined. 100WP/100WP+ operating modes • Error! Bookmark not defined. 100WP/100WP+ pulser start-up • Error! Bookmark not defined. A about the 100W/100W+ and 100WP/100WP+ ERT Module • Error! Bookmark not defined. B base mount installation • Error! Bookmark not defined. battery life • Error! Bookmark not defined. before you begin • Error! Bookmark not defined. C cable armor • Error! Bookmark not defined. connecting the 100WP/100WP+ to a remote meter register • Error! Bookmark not defined. H how this document is organized • Error! Bookmark not defined. I initializing the 100W/100W+ • Error! Bookmark not defined. initializing, connecting, and programming the ERT module • Error! Bookmark not defined. installing the 100W/100W+ and 100WP/100WP+ ERT Module • Error! Bookmark not defined. installing the remote antenna • Error! Bookmark not defined. L Leak Sensor installation equipment • Error! Bookmark not defined. O optional direct connect remote antenna installation • Error! Bookmark not defined. optional Leak Sensor installation • Error! Bookmark not defined. P pipe preparation • Error! Bookmark not defined. programming the 100WP/100WP+ • Error! Bookmark not defined. R related documents • Error! Bookmark not defined. required hardware • Error! Bookmark not defined., Error! Bookmark not defined., Error! Bookmark not defined., Error! Bookmark not defined. rod mount installation • Error! Bookmark not defined. S security • Error! Bookmark not defined. shelf mount installation • Error! Bookmark not defined. T through lid installation • Error! Bookmark not defined., Error! Bookmark not defined. U using an extension cable • Error! Bookmark not defined. Index
Index   TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 48  Proprietary and Confidential    using an inline connector • Error! Bookmark not defined. using the Itron splice kit • Error! Bookmark not defined. V verifying 100W/100W+ and 100WP/100WP+ ERT Module operation • Error! Bookmark not defined.