Itron 24GZR AMR Transceiver Device For Utility Meters User Manual Users Manuel Chp Three

Itron, Inc. AMR Transceiver Device For Utility Meters Users Manuel Chp Three

Users Manuel Chp Three

Download: Itron 24GZR AMR Transceiver Device For Utility Meters User Manual Users Manuel Chp Three
Mirror Download [FCC.gov]Itron 24GZR AMR Transceiver Device For Utility Meters User Manual Users Manuel Chp Three
Document ID1174037
Application ID+4wabefAyJCvK+QwVQRKqg==
Document DescriptionUsers Manuel Chp Three
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize70.95kB (886897 bits)
Date Submitted2009-09-23 00:00:00
Date Available2009-09-25 00:00:00
Creation Date2009-09-09 06:44:30
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2009-09-23 09:46:57
Document Title2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Document CreatorAcrobat PDFMaker 9.1 for Word
Document Author: TDC-0838-000

CHAPTER 3
Rotary Meter Installation
This chapter provides the instructions to install the 2.4GZ OpenWay Remote Mount Gas
Module on rotary gas meters. Reference the Gas Endpoint Meter Compatibility List (see
Related Documents on page 3) for rotary meters compatible with the 2.4GZ OpenWay
Remote Mount Gas Module.
American rotary meter
Dresser ROOTS® Series LMMA rotary meter
Dresser ROOTS® series B3 meter
Romet Imperial series RM meter
Romet Imperial ECM2 meter
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
23
Chapter 3
Rotary Meter Installation
Required Installation Materials Available from Itron
The materials in the following table are required to install a 2.4GZ OpenWay Remote
Mount Gas Module.
Itron Part Number
OWG-5001-502 IPP
OWG-5002-502 SEP
OWG-5001-503 IPP
OWG-5002-503 SEP
Note: this remote mount endpoint comes
standard with 12" lead wires and may be
shipped directly to the meter
manufacturer for a factory-installed cable
(interface).
Important The interface cable must be purchased directly from the meter
manufacturer.
CFG-0005-003
Remote Endpoint Mounting Kit
24
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Connecting the 2.4GZ OpenWay Remote Mount Module to the Rotary Meter Cable
Connecting the 2.4GZ OpenWay Remote Mount Module to the
Rotary Meter Cable
You may ship the Itron 2.4GZ OpenWay Remote Mount Gas Module directly to the meter
manufacturer for a factory-installed cable. If you connect the endpoint to the meter using an
existing cable purchased from the meter manufacturer, complete the following cable
installation procedure.
Caution The purchased cable must have a mating connector compatible to the
meter receptacle. Meter manufacturer's cables may be wired in different
configurations for specific applications. If necessary, contact your meter's
manufacturer for wiring diagrams for your specific application.
To connect the 2.4GZ OpenWay Remote Mount Gas Module to the rotary
meter cable
1. Remove the backplate (4 screws) from the 2.4GZ OpenWay Remote and expose the
module's lead wires. The backplate and screws will be re-installed on the gas module
later in this procedure so store them (temporarily) in a safe, secure place.
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
25
Chapter 3
Rotary Meter Installation
2. Insert the lead wires from the 2.4GZ OpenWay Remote Mount Gas Module into new
3M gel connectors (Itron part number CON-0023-001) together with the same colored
lead wire from the meter cable (see the wiring table below) and crimp using a 3M
hand-held crimping tool.
Note Do not strip lead wire prior to inserting the wire in the gel connector.
Rotary Meter to Remote Module Wire Table
Rotary Meter
Remote module wire
Wire
Red
Red
26
White
White
Blue
Blue
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Connecting the 2.4GZ OpenWay Remote Mount Module to the Rotary Meter Cable
3. After completing the wiring connections, install a cable tie to the meter cable just
below the exposed colored lead wires on the cable insulation. Remove the excess
cable tie using a hand-held sidecutter pliers. The cable tie performs as a cable strain
relief to mitigate the risk of destructive tension on the lead wires.
4.
Tuck the three gel connectors and cable tie inside the module housing, as shown.
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
27
Chapter 3
Rotary Meter Installation
5. Install the 2.4GZ OpenWay Remote Mount Gas Module backplate using the four
screws previously removed from the module and a Torx T-15 screwdriver. Install the
new 2.4GZ OpenWay Remote Mount Gas Module on the wall or a pipe using the
Remote Endpoint Mount Kit (Itron part number CFG-0005-003). See Mounting the
2.4GZ OpenWay Remote Mount Gas Module on page 9 for mounting instructions.
To connect the 2.4GZ OpenWay Remote Mount Gas Module cable assembly
to the rotary meter
Caution Verify the cable connector mates with the meter connector. Meter
manufacturers use different connector styles (types).
1.
28
Align the large lug on the 2.4GZ OpenWay Remote Mount Gas Module connector
with the large notch on the meter connector.
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Connecting the 2.4GZ OpenWay Remote Mount Module to the Rotary Meter Cable
2. Align the lock ring notches on the module cable connector with the pins on the meter
connector.
3. Hold the lock ring on the module connector back and push the plug into the meter
connector until it is securely seated.
4. Turn the lock ring clockwise as far as it will go. You will feel it snap into place when
it locks.
Warning To remove the module connector plug from the meter connector jack,
push in on the lock ring, turn the lock ring counterclockwise as far as possible,
and pull out the plug body. Do not pull on the module's connector cable.
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
29
Chapter 3
Rotary Meter Installation
Programming 2.4GZ OpenWay Remote Mount Gas Module for
Dresser ROOTS® Rotary Meters
To program 2.4GZ OpenWay Remote Mount Gas Modules for use with Dresser ROOTS®
rotary meters, use the meter drive rates from the drive rate table in this section.
B3, LMMA & S3A CTR/TC Meter Pulse Rates for Remote
Module Programming
Caution Do not use these meter drive rates to program residential direct-drive or
commercial direct-drive modules. Use the information in the following tables to
program 2.4GZ OpenWay Remote Mount Gas Modules connected to Dresser
ROOTS® rotary meters.
30
B3 CTR Meter
Size
B3 CTR Meter
Pulse Rate
LMMA CTR
Meter Size
LMMA CTR
Meter Pulse
Rate
8C
10
1.5M
10
11C
10
3M
10
15C
10
5M
10
2M
10
7M
10
3M
10
11M
10
5M
10
16M
100
7M
10
23M
100
11M
10
38M
100
16M
100
56M
100
23M
100
102M
100
38M
100
56M
100
LMMA CTR
Meter Size
LMMA CTR
Meter Pulse
Rate
LMMA TC
Meter Size
LMMA TC Meter
Pulse Rate
1.5M
10
1.5M
10
3M
10
3M
10
5M
10
5M
10
7M
10
7M
10
11M
10
11M
10
16M
100
16M
100
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Programming 2.4GZ OpenWay Remote Mount Gas Module for Dresser ROOTS® Rotary Meters
B3 CTR Meter
Size
B3 CTR Meter
Pulse Rate
23M
100
38M
100
56M
100
102M
100
Meters built 1/99 and beyond
B3 TC Meter
B3 TC Meter
Size
Pulse Rate
LMMA CTR
Meter Size
LMMA CTR
Meter Pulse
Rate
Meters built prior to 1/99
B3 TC Meter
B3 TC Meter
Size
Pulse Rate
8C
10
8C
50
11C
10
11C
50
15C
10
15C
50
2M
10
2M
50
3M
10
3M
50
5M
10
5M
50
7M
10
7M
50
11M
10
11M
50
16M
100
16M
500
S3A CTR
Meter Size
S3A CTR
Meter Pulse
Rate
S3A TC Meter
Size
S3A TC Meter
Pulse Rate
1.5M
10
1.5M
10
3M
10
3M
10
5M
10
5M
10
7M
10
7M
10
11M
10
11M
10
16M
100
16M
100
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
31
Chapter 3
Rotary Meter Installation
Installing the 2.4GZ OpenWay Remote Mount Gas Module to
the Elster American Meter RPM Series Rotary Meter
Some meter manufacturers provide endpoint mounting kits and installation procedures for
their meters.
If 2.4GZ OpenWay Remote Mount Gas Module to Elster American RPM meter installation
instructions are not available, follow the installation procedure in this section.
To install the 2.4GZ OpenWay Remote Mount Gas Module on an Elster
American RPM series meter
1. Remove the meter's top plate by removing the two (2) 5mm screws and carefully
prying up on the plate. The plate is secured with an o-ring seal. Remove the o-ring
from the plate.
Caution If the o-ring is damaged during removal, obtain a replacement from
Elster American Meter Co.
2. Look into the meter tower and find the meter switch lead and connector (4-pin).
32
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Installing the 2.4GZ OpenWay Remote Mount Gas Module to the Elster American Meter RPM Series Rotary Meter
3. If the lead and connector are not visible or cannot be found, remove the four (4) 5mm
mounting screws and the register cover. The meter switch lead and connector will be
visible inside the cover.
Note Save any meter tags. You will re-install them later in the installation
process.
4. Feed the lead and connector into the register cover tower.
5. If you removed the register cover, replace the cover using the four (4) 5mm mounting
screws.
6. Attach the 4-pin male connector on the Elster American Meter adapter plate to the 4pin female connector inside the meter's tower. The connectors will slide together and
latch.
7. Carefully push the connectors and wires into the meter tower housing.
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
33
Chapter 3
Rotary Meter Installation
8. Lubricate the o-ring with o-ring lubricant and install the o-ring on the adapter plate.
Insert the adapter plate into the tower and tighten the (2) 5 mm screws.
To connect the manufacturer cable to the endpoint
Note Connection to an Elster American Meter requires a cable interface
compatible to an Elster American Meter RPM rotary meter.
1. Trim the 2.4GZ OpenWay Remote Mount Gas Module wires to 3.5".
2. Carefully strip the insulation covering from the meter cable (purchased from the meter
manufacturer) approximately 1 1/2" from the end.
Caution Do not cut through the individual wire insulation.
3. Separate the black, white, and blue wires for connection to the 2.4GZ OpenWay
Remote Mount Gas Module. Cut off the unused wires even with the outer covering
(insulation).
Caution Do not strip the individual wires.
34
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Installing the 2.4GZ OpenWay Remote Mount Gas Module to the Elster American Meter RPM Series Rotary Meter
4. Connect the meter cable to the 2.4GZ OpenWay Remote Mount Gas Module using
3M gel-cap connectors. Follow the wire connection table and wiring diagrams below.
See Installation Prerequisites on page 7 for appropriate 3M crimping tools.
American RPM Meter to 2.4GZ Remote Mount Module Wire
Connections
American RPM Meter wire 2.4GZ Remote Mount module wire
Red
Red
White
White
Black
Blue
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
35
Chapter 3
Rotary Meter Installation
5. Insert the meter cable through the slot on the module backplate. Install a cable tie to
the meter cable wire below the meter cable insulation to provide strain relief.
6. Tuck the connectors and cable tie into the endpoint housing. Place backplate on the
assembly and tighten the four backplate screws using a size T-10 Torx screwdriver.
36
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Mounting the 2.4GZ OpenWay Remote Mount Module
To install the 2.4GZ OpenWay Remote Mount Gas Module cable
1. Insert the plug on the cable connected to the module into the receptacle on the meter
adapter plate.
2. Tighten the threaded collar on the plug onto the Amercian Meter interface receptacle.
Verify the connection is hand-tight.
Mounting the 2.4GZ OpenWay Remote Mount Module
Select an appropriate mounting location on adjacent piping close to the meter. Using the
pipe bracket, mounting plate and band clamps from the Remote Mount Kit (Itron part
number CFG-0005-003), secure the 2.4GZ OpenWay Remote Mount Gas Module. Use the
cable ties from the kit to secure any excess wire to the piping (see Mounting the 2.4GZ
Remote Mount Module on a Pipe on page 10).
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
37
Chapter 3
Rotary Meter Installation
Installing the 2.4GZ OpenWay Remote Mount Gas Module to
the Romet Electronically Compensated Meter (ECM2® )
The Romet ECM2® meter has three Form "A" outputs that can be configured at the factory
to provide any combination of the following three outputs:
•
Uncorrected volume (UNC VOL)
•
Corrected volume (COR VOL)
•
Alarm
The pulse weight for the volumetric outputs is configured in SetUp Mode at Menu
items>SET UNC OUT and SET COR OUT. Since Setup Mode is fully configurable, the
ECM2® module is universally adaptable to all Romet TC meter bodies. Reference the
Romet technical manual for specific details on the ECM2®.
38
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to the Romet ECM2® Meter
Connecting the 2.4GZ OpenWay Remote Mount Gas Module
to the Romet ECM2® Meter
Connect the correct interface wirings and set the output pulse spacing to complete 2.4GZ
OpenWay Remote Mount Gas Module installation with the Romet ECM2® meter. See the
ECM2® Interface Wiring Table below to complete wire connections.
Function
(+)UC
(-)UC
(+)CC
(-)CC
(+)ALM
(-)ALM
(+)Aux.CC
(-)Aux.CC
Endpoint Wire
White and
Blue
Red
White and
Blue
Red
White and
Blue
Red
White and
Blue
Red
34-125-20
34-125-40
Pin location 34-125-41
for Cannon
Connector 34-125-42
Part Number 34-125-43
34-125-44
34-125-45
34-125-50
34-125-51
Caution Set the ECM2® output pulse spacing to 750ms for operation with the
2.4GZ OpenWay Remote Mount Gas Module. Output spacing represents an offtime between pulses.
To mount the 2.4GZ OpenWay Remote Mount Gas Module on the Romet
ECM2 meter
This mounting procedure requires the Romet ECM2/Module Mounting Kit (Romet part
number 34-444-1-KIT).
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
39
Chapter 3
Rotary Meter Installation
1. Remove the module screw from the back of the ECM2 meter and discard.
2. Insert the mounting screw fitted with the three lock washers. Two lock washers are
used as spacers as shown.
3. Attach the mounting plate to the meter. Insert the mounting screw where the module
screw was removed. Torque the mounting screw to 5 - 7 ft.lbs. to secure the plate to
the Romet meter.
40
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Connecting the 2.4GZ OpenWay Remote Mount Gas Module to the Romet ECM2® Meter
4. Mount the 2.4GZ OpenWay Remote Mount Gas Module using the pre-drilled holes on
the mounting plate and the module mounting screws. Place new tamper seals over the
two screws. Press tamper seals into place using an 11/32" nut driver or similar blunt
tool. Connect the module to the meter using the previously installed cable interface.
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
41
Chapter 3
42
Rotary Meter Installation
TDC-0838-000 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Author                          : TDC-0838-000
Create Date                     : 2009:09:09 06:44:30-05:00
Modify Date                     : 2009:09:23 09:46:57-07:00
Subject                         : Natural Gas Solutions
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2009:09:23 09:46:57-07:00
Creator Tool                    : Acrobat PDFMaker 9.1 for Word
Format                          : application/pdf
Title                           : 2.4GZ OpenWay Gas Module Installation Guide - Remote Mount
Description                     : Natural Gas Solutions
Creator                         : TDC-0838-000
Document ID                     : uuid:56e58f0f-34f8-4b91-81df-da67c5d87259
Instance ID                     : uuid:7a93b307-d853-40cd-a7de-10eb71791187
Producer                        : Adobe PDF Library 9.0
Page Count                      : 20
EXIF Metadata provided by EXIF.tools
FCC ID Filing: EO924GZR

Navigation menu