JCM Technologies RB-G-RX10 Transceiver for Automatic Door Safety Edges Relay Output User Manual
JCM Technologies, S.A. Transceiver for Automatic Door Safety Edges Relay Output
User Manual
INSTALLATION INSTRUCTIONS Model: RB-G-K10 IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION. The Miller Edge RBand Monitored Gate Edge Transmitter/Receiver system is intended to provide a wireless connection between a monitored sensing edge and a motorized operator that controls the associated gate. RBand meets the 2016 UL 325 requirements for monitored devices and has been certified as a UL 325 Recognized Component. It is designed for use with operators that comply with 2016 UL 325 using a Miller Edge 10K Sensing Edge. 1. PARTS LIST Kit Contents: 1. RBand Edge Transmitter (RB-TX10) 2. RBand Gate Edge Receiver (RB-G-RX10) 3. Receiver antenna 4. (2) 3.6V AA lithium batteries* 5. (4) #6 pan head transmitter mounting screws *Replacement 3.6V AA lithium batteries can be purchased at your local electronics store or via Miller Edge. Required: • 1/8” flat blade screwdriver • 1/4” flat blade screwdriver • Miller Edge 10K (T2/blue band) Sensing Edge • Coaxial cable for exterior mounted antenna • Coaxial bulkhead adapter, female/female Recommended: • Multi-meter capable of reading 10KΩ • Mounting screws for the Receiver 2. RECEIVER: INSTALLATION 2-1. Remove operator cover and turn off the power to the gate operator. 2-2. Determine where to place the external mounted antenna so it is in line of sight with the Transmitter for the entire range of travel [IMAGE 1]. Prepare the antenna coax as necessary. 2-3. Remove Receiver cover and mount the base inside the operator, positioning it for optimum ease of wiring. 2-4. Connect power to the terminals marked 12/24 AC/DC (polarity sensitive) on the removable 8-pin connector [IMAGE 2]. 2-5. Determine which monitored interface your operator uses. Connect the COM (C1/C2) and the correct output connections (N.C. = CS1/CS2 or 10K = BS1/BS2) to your operator. There are 2 separate relays (channels): R1 and R2. The A Test terminals must be used for operators requiring N.C. inputs. Enable with DIP switch 4 [TABLE 1]. 2-6. Replace the Receiver cover and turn on power to the operator. Note: it takes ~5 seconds for the Receiver to initialize. Note: RBand 10K Gate Edge Receiver is compatible with up to 3 RBand Transmitters on 2 channels (6 total). SENSING EDGE OPERATOR WIRING ANTENNA RBAND RECEIVER MOUNTED INSIDE OPERATOR WITH EXTERNAL ANTENNA RBAND TRANSMITTER MOUNTED NEAR SENSING EDGE IMAGE 1. RBand Transmitter Installation with Gate Edge RB-G-K10_Install_A4_20170706 www.milleredge.com info@milleredge.com 800-220-3343 LED INDICATORS Initial Power • No Transmitters Programmed: R1 & R2 LEDs on COAXIAL CABLE PROVIDED BY INSTALLER R1 or R2 LED • Programmed: Off • Fault Condition: On R3 LED • On when battery is low A TEST LED • On when in test mode F-CONNECTOR COAX EXTENDER ANTENNA ANTENNA CHECK LED TERMINAL & BUTTON BLOCK RELAY LEDS PROGRAM BUTTON CHECK LED (both channels programed) • Programmed: Check LED flashes every 5 seconds DIP SWITCH SETTINGS ON 1 2 3 4 Switch 1-3: Leave switches in factory default settings Switch 4: Used to enable Normally Closed cycle testing: • N.C. Operator: Set to on and connect the switched power to the A Test and Common pins shown above • 10K Operator: Set to off GND ANT CHECK PROG R1 R2 MR ON 1 2 3 4 R3 A TEST TABLE 1. REMOVABLE CONNECTORS For Normally Closed gate operators, please reference page 5. 8-PIN CONNECTOR Power +12/24 AC/DC Constant power source -12/24 AC/DC Constant power source (ground) + - CS1 C1 12/24 AC/DC BS1 CS2 C2 BS2 NO3 Relay Output 1 CS1 N.C. monitored input C1 Monitored input Common BS1 10K monitored input C3 COM. A TEST Relay Output 2 CS2 N.C. monitored input C2 Monitored input Common BS2 10K monitored input REMOVABLE 8-PIN CONNECTOR REMOVABLE 4-PIN CONNECTOR DIP SWITCHES IMAGE 2. RBAND GATE EDGE RECEIVER PCB & CONNECTIONS www.milleredge.com 4-PIN CONNECTOR Relay Output 3 NO3 Low battery alarm (optional) C3 Low battery alarm (optional) info@milleredge.com N.C. Power Cycling COM: Switched power Common COM. A TEST +12/24VDC: Switched power source 800-220-3343 PROGRAM BUTTON (2) 3.6V AA LITHIUM BATTERIES GREEN LED ALIGNMENT PIN ALIGNMENT PIN REMOVABLE SENSING EDGE TERMINAL BLOCK (4) CORNER MOUNTING HOLES STRAIN RELIEF FITTING IMAGE 3. RBand Edge Transmitter PCB & Connections 3. TRANSMITTER: PROGRAM MODE 3-1. Confirm the Receiver is powered up. Prior to mounting the Transmitter, remove the cover and insert the batteries, noting their polarity. The green LED on the Transmitter should blink to indicate that it has not been associated with the Receiver yet [IMAGE 3]. 3-2. To enter learn mode, press and hold the Receiver program button for ~2 seconds until the R1 LED turns on, then release the button [IMAGE 2]. 3-3. Press the Transmitter program button for ~2 seconds [IMAGE 3]. The Receiver should beep. Wait 10 seconds for an additional beep to indicate that programming is complete. 3-4. To program a Transmitter to Channel 2, press and hold the Receiver program button until the second beep, then release the button. The R2 LED should be on [IMAGE 2]. Repeat 3-3. 4. TRANSMITTER: INSTALL & TEST 4-1. Strip back approximately 2 inches of outer covering of sensing edge cable, then feed through Transmitter strain relief fitting. Connect the two sensing edge wires to the removable terminal. Dress the wires with a small service loop and tighten the strain relief. Mount unit utilizing the mounting holes at the 4 corners of the Transmitter box. Affix lid to Transmitter, noting the alignment pin [IMAGE 3]. 4-2. Test the sensing edge for functionality. 5. TROUBLESHOOTING If the Receiver does not react to the Transmitter, you can check the RF signal strength: 5-1. Press the check button on the Receiver for ~2 seconds [IMAGE 2]; 4 beeps will be heard. You then will hear a beep every 1-1/2 seconds during the check process. Wait about 30 seconds; if no other beeps occur, your system is functioning. 3 quick beeps indicates a communication error. 5-2. Activate the sensing edge and observe the check LED; 3-5 flashes is ideal. Less than 3 flashes means there is a weak signal. 5-3. To exit check function, press the check button, or system will time-out after 5 minutes. There will be a series of beeps heard upon exiting. 6. ERASING THE RECEIVER If you need to replace a Transmitter or you have any other programming issues, you may need to erase the Receiver. 6-1. To erase any Transmitters programmed into the Receiver, use a screwdriver to short the two pins marked MR next to the DIP switches [IMAGE 2]. 6-2. While shorting the pins, press and hold the program button for several seconds; you will hear a series of 10 beeps followed by a rapid chirping sound. 6-3. When the chirping stops, release the program button. Wait ~10 seconds and you will hear 2 beeps. The Receiver is now ready to be reprogrammed. www.milleredge.com info@milleredge.com 800-220-3343 7. RECEIVER: SPECIFICATIONS & CONTROLS Power: 12-24 VAC/DC nominal (11-30 V max); 100 mA max current draw. Power may be supplied from the operator or alternatively from an external supply. Dimensions: 4.12”L x 3.65”W x 1.65”H Dimensions: 4.12”L x 3.65”W x 1.65”H Cable Connections: Screw clamp type terminal blocks for 18-26 AWG wire Operator Wiring: Screw clamp type terminal blocks for 18-26 AWG wire External Antenna: Monopole antenna supplied (gain: 5dBi +/-2dB) Program Button: Used to associate a Transmitter with the desired receiver channel Check Button: Used to determine signal strength RX Indicator Lights: • Check LED: 1. Blinks every ~5 seconds to indicate working properly if both channels are programmed 2. After check button is pressed, blinks to indicate signal strength; 4 or 5 blinks is ideal • R1 and R2 LEDs: 1. Off when the associated edge is learned and has no faults 2. On solid: No Transmitters learned or edge activated • R3 LED: On when low battery relay is active • A TEST LED: On when in test mode Connections: • Power (2): Positive and ground, or AC • Relay Output 1: 1. CS1: Normally Closed 2. C1: Common 3. BS1: 10K termination • Relay Output 2: 1. CS2: Normally Closed 2. C2: Common 3. BS2: 10K termination Relay Output 3 (2): Relay closes when low battery is detected • A TEST (2): Connect to switched DC power (+ and Com) for Normally Closed monitoring • 8. TRANSMITTER: SPECIFICATIONS & CONTROLS Transmitter Frequency: 916 MHz, FSK modulation Mounting: 4 corner screws (provided) Power Source: Batteries: 2 AA, 3.6V lithium, 2 year life expectancy Dimensions: 1.80”L x 4.78”W x 1.75”H Program Button: Momentary push button is used to associate the Transmitter to the Receiver TX Indicator Lights: Green LED: Normally off • Press program button for status • 9. FCC COMPLIANCE RBand Transmitter Model: RB-TX10 FCC ID: U5Z-RB-TX10 RBand Receiver Model: RB-G-RX10 FCC ID: U5Z-RB-G-RX10 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. 2. 1. 2. This device may not cause harmful interference and This device must accept any interference received, including interference that may cause undesired operation. This device complies with FCC radiation exposure limits for an uncontrolled environment. This device shall be installed and operated with a minimum distance of 0.4” between users or bystanders and the device. This device may not cause harmful interference and This device must accept any interference received, including interference that may cause undesired operation. This device complies with FCC radiation exposure limits for an uncontrolled environment. This device shall be installed and operated with a minimum distance of 0.8” between users or bystanders and the device. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules: These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which may be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. Re-orient or relocate the receiver antenna 2. Increase the separation between the equipment and the receiver 3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4. Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. www.milleredge.com info@milleredge.com 800-220-3343 NORMALLY CLOSED ADDENDUM: Removable Connector Assignments by Manufacturer All-O-Matic ON COMMON MON-12 VDC COMMON MON_OPEN COMMON GROUND MON_CLOSE +12 or 24 VDC - CS1 C1 BS1 CS2 C2 BS2 NO3 C3 12/24 AC/DC COM.A TEST HySecurity 1 2 3 4 DIP Switch #4 • Turn to on ON +24 VDC SENSOR COM S1, S2, S3 SENSOR COM SENSOR COM S1, S2, S3 +24 VDC COMMON* - CS1 C1 BS1 CS2 C2 BS2 NO3 C3 12/24 AC/DC COM.A TEST 1 2 3 4 DIP Switch #4 • On to run • Off to test * Not “Sensor Common” Maximum Controls ON www.milleredge.com GND** +12 VDC** GND** EDGE 2** GND** EDGE 1** GND* 12 or 24 VDC* - CS1 C1 BS1 CS2 C2 BS2 NO3 C3 12/24 AC/DC COM.A TEST 1 2 3 4 DIP Switch #4 • Turn to on * Main board ** MC200 Motor Controller info@milleredge.com 800-220-3343
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Language : en-US XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Create Date : 2017:07:06 11:07:16-04:00 Metadata Date : 2017:07:07 12:10:51+02:00 Modify Date : 2017:07:07 12:10:51+02:00 Creator Tool : Adobe InDesign CC 2017 (Macintosh) Instance ID : uuid:412d6fa3-b0ad-4707-802b-17734fa46041 Original Document ID : xmp.did:f564ea27-4df4-41fe-9869-41485219c054 Document ID : xmp.id:6b7dfc2b-3ccd-4816-b4fa-4c5cdf6c7286 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:4b1fa77f-c6b6-4717-8110-7a2082ff0935 Derived From Document ID : xmp.did:4b1fa77f-c6b6-4717-8110-7a2082ff0935 Derived From Original Document ID: xmp.did:f564ea27-4df4-41fe-9869-41485219c054 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Macintosh) History Changed : / History When : 2017:07:06 11:07:16-04:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Slug Family : Wingdings 3 Slug Version : 5.03 Slug Outline File Size : 0 Slug Kerning Checksum : 0 Slug Foundry : Bigelow And Holmes Slug Font Kind : OpenType - TT Slug Checksum : 2736056821 Slug Post Script Name : Wingdings3 Slug Font Sense 12 Checksum : 2736056821 Page Count : 5 Creator : Adobe InDesign CC 2017 (Macintosh)EXIF Metadata provided by EXIF.tools