JLG 1001147542 Wireless Analyzer Module User Manual 3121600
JLG Industries Inc (An Oshkosh Company) Wireless Analyzer Module 3121600
JLG >
User Manual
Setup and Operation Manual Wireless Analyzer Module (WAM) ANSI ® Preliminary Review Copy Only 4-08-2015 P/N - 3121600 April X, 2015 NOTES: FOREWORD FOREWORD NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Any changes / modifications not approved by the JLG Industries Inc., could void the user’s authority to operate this equipment. FOREWORD NOTES: TABLE OF CONTENTS SECTION - PARAGRAPH, SUBJECT PAGE SECTION - PARAGRAPH, SUBJECT LIST OF FIGURES SECTION - 1 - WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS 1.1 1.2 1.3 1.4 1.5 PAGE PACKAGE CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 WIRELESS SETUP (PHONE, TABLET) . . . . . . . . . . . . . . . . . . . . . . .1-1 APPLICATION - STARTUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 CONNECTING THE APPLICATION TO THE WAM . . . . . . . . . . . .1-4 APPLICATION - SETUP SCREEN. . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Language Select. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Check for Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7 Advanced Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7 Wireless Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7 Name - Set/Change . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8 Password - Set/Change. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8 Advanced Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8 Application Setup Screen - Dpad (Tablets Only) . . . . . . . . .1-8 1-1. 1-2. 1-3. 1-4. 1-5. 1-6. 1-7. 2-1. Wi-Fi Networks Configuration Screen Example . . . . . . . .1-2 Analyzer Home Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 Analyzer Home Screen - Connected . . . . . . . . . . . . . . . . . . .1-4 Change Language Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 Language Update Sequence - Apple® . . . . . . . . . . . . . . . . .1-6 Language Update Sequence - Android . . . . . . . . . . . . . . . .1-6 Wireless Settings Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7 Wireless Analyzer Module (WAM) . . . . . . . . . . . . . . . . . . . . .2-1 LIST OF TABLES 2-1 2-2 Default Wireless Analyzer Module Settings . . . . . . . . . . . 2-1 WAM LED Status Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 SECTION - 2 - WIRELESS ANALYZER MODULE - SETUP AND TROUBLESHOOTING 2.1 2.2 2.3 FIRST TIME -SET-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 Setting Wi-Fi Name (SSID) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 Setting Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 TROUBLESHOOTING THE JLG WIRELESS ANALYZER MODULE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 FACTORY DEFAULT - RESET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4 3121600 – JLG Lift – REVISON LOG REVISION LOG Original Issue of Manual. . . . . . . . . . . . . . . . . . . . . April 24, 2013 Manual Revised . . . . . . . . . . . . . . . . . . . . . . . . . . . . . April X, 2015 ii – JLG Lift – 3121600 SECTION 1 - WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS SECTION 1. WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS 1.1 PACKAGE CONTENTS 1.2 • JLG Wireless Analyzer Module interface - (JLG Part Number: 1001147542, or 1001156446 - SUNBELT® Labeled) (See Figure 1-1. on page 1-2) After installing the application (app) and prior to connecting the application to the Wireless Analyzer Module, (WAM), your phone or tablet must have it’s WiFi settings configured so that it is connected to the WAM. For example the following Figure 1-1. shows the devices Wi-Fi connected to a WAM named JLGTOOL-0033. • Users Manual (JLG Part Number: 3121600) Read thoroughly, before attempting to connect. The JLG wireless analyzer application (app) can be downloaded and installed onto a phone or tablet using iTunes® (Apple® Devices) or Google Play® (Android Devices) websites. WIRELESS SETUP (PHONE, TABLET) NOTE: Out of the box, the default Wi-Fi WAM device name is JLGWAM-0001, if you would like to rename your device, See page 2-2, JLG Wireless Analyzer Application - Wireless Settings, for instructions on naming your WAM device. # 10 0114 7572 Package Contents 3121600 – JLG Lift – 1-1 SECTION 1 - WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS Apple® Wireless Settings Android Wireless Settings Figure 1-1. Wi-Fi Networks Configuration Screen Example 1-2 – JLG Lift – 3121600 SECTION 1 - WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS 1.3 APPLICATION - STARTUP Pressing the application button will start the JLG Wireless Analyzer application. A splash screen will show briefly, followed by the wireless analyzer home screen. Analyzer Home Screen - Apple® Analyzer Home Screen - Android Figure 1-2. Analyzer Home Screen Analyzer Splash Screen 3121600 – JLG Lift – 1-3 SECTION 1 - WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS 1.4 This icon will appear in the lower right corner of the text display area if the application cannot find the translated text in the database. In that case the English text coming directly from the analyzer port will be displayed. CONNECTING THE APPLICATION TO THE WAM (See Figure 1-2. on page 1-3) • Android devices - to bring up the Connect/Help/Setup buttons, at the bottom of the home screen; At this point the user buttons function in the same manner as the wired JLG analyzer to navigate the menus. press this icon on a (Tablet) or; this icon on a (Phone). You will then see the Connection, Help, and Setup buttons appear at the bottom. • Apple devices - the home screen will display the buttons when the application is started. Pressing the connect button will connect the application to the machine. The initial analyzer screen should appear after a short time. (See Figure 1-3.) Once connected, the icon in the lower right corner of the screen will change to the application connected status. After connection, the displayed text can be made larger by touching the AA icon in the upper right corner of the text display area. There are two sizes of text, small and large. 1-4 Analyzer Home Screen - Apple® – JLG Lift – Analyzer Home Screen - Android Figure 1-3. Analyzer Home Screen - Connected 3121600 SECTION 1 - WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS 1.5 APPLICATION - SETUP SCREEN Language Select Touching the Language selection will bring up a dialog that will allow a user to choose the desired language that analyzer screens will be translated into. Touching the setup button will bring up a dialog box with the following selections. NOTE: You must be disconnected from the machine and either have a Wi-Fi internet connection available or a cellular signal to successfully change the language selection. • Apple devices, once a language is chosen touch the apply button to begin the language change. (See Figure 1-4.) • Android devices, a dialog box will appear with the choice to proceed or cancel. (See Figure 1-4.) Choosing apply will begin the language update process. You will see the status of the update via a progress indicator. (See Figure 1-5. and Figure 1-6.) Once finished, touching the back button will exit out of the setup menu. You may need to go back to the wireless settings to reconnect the phone or tablet to the JLG WAM. Analyzer Setup Screen - Apple® 3121600 Analyzer Setup Screen - Android – JLG Lift – 1-5 SECTION 1 - WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS Figure 1-5. Language Update Sequence - Apple® Apple® Android Figure 1-4. Change Language Screen Figure 1-6. Language Update Sequence - Android 1-6 – JLG Lift – 3121600 SECTION 1 - WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS Check for Update Touching the Check for Update selection will cause the phone or tablet to search the Apple® iTunes® or Google Play® for the JLG Wireless Analyzer application software, and/or a text database update. You must be disconnected from the WAM and either have a Wi-Fi connection or a cellular signal to successfully complete an application software/text database update. power to the JLG WAM by using the E-stop on the machine, or unplugging and plugging the JLG WAM back into the analyzer connector. Advanced Mode Selecting this option will cause the application to display the analyzer text in the current language selected. De-selecting this option will cause the application to display analyzer screens in the original analyzer screen format in English only. Wireless Settings This screen allows the user to modify the WAMs' internal settings. You must be connected to the WAM through the wifi connection, but not have the Wireless Analyzer application connected, i.e. not displaying analyzer screens. Touching on the particular setting to be changed will bring up a numeric or alphanumeric keypad to allow that setting to be changed. If no changes need to be made, press the back button to exit to the previous screen. When finished press the apply button to store the changes in the module. Once finished cycle 3121600 – JLG Lift – Apple® Android Figure 1-7. Wireless Settings Screen 1-7 SECTION 1 - WIRELESS ANALYZER APPLICATION (APP) INSTRUCTIONS Name - Set/Change This menu item is the name given to the WAM that will display when scanning for wireless connections. All JLG WAMs come defaulted to the same wireless settings therefore you MUST set the WAMs name first to avoid conflicts with other WAMs. The name can be up to 32 characters long, but must not contain spaces and typically consists of letters and numbers. Password - Set/Change The WAM is capable of being password protected so only you may connect to it. The name can be up to 32 characters long, but must not contain spaces and should be something easily remembered. Once the password is set on your phone or tablet the application will store and remember it so future connections will connect with no prompting for a password. However if another phone or tablet attempts to connect a dialogue screen will appear prompting the user to enter the password for the WAM. Failure to remember the password will render the WAM locked and a default reset will need to be performed. See WAM hardware section for instructions. Advanced Settings These settings should only be accessed if you are experiencing communication problems. • Wireless Channel Number - (must be a number from 114**) this will set the wireless channel the device communicates on. Typical choices are channels 1, 6, and 11 1-8 because there is no communication overlap between these but any channel can be selected. NOTE: ** North America allows use of channels 1-11 only. If you are operating in North America and you set the channel to 12, 13, or 14 you may no longer be able to see the WAM when trying to connect. In this case you will have to reset the WAM to the default settings as described in the WAM hardware section. • Timeout - (30 - 9999 seconds) this will set the communication idle timer. When expired the WAM will disconnect from the phone or tablet automatically. • Wireless Rate - (24, 36, 48, 54 Mbps) this sets the wireless over the air communication rate. Application Setup Screen - Dpad (Tablets Only) This setting allows a user to set the size/position of the keypad on the screen. NOTE: This option is only available when running the application on a tablet and gives the ability for one handed operation of the application. The choices are center, left, and right. Choosing the center will expand and center the keypad. Choosing left or right will condense the keypad and left or right justify it on the screen. – JLG Lift – 3121600 SECTION 2 - WIRELESS ANALYZER MODULE - SETUP AND TROUBLESHOOTING SECTION 2. WIRELESS ANALYZER MODULE - SETUP AND TROUBLESHOOTING 2.1 FIRST TIME -SET-UP When you first power up the JLG Wireless Analyzer Module it will be set to the following factory defaults: Table 2-1. Default Wireless Analyzer Module Settings Wireless Name JLGWAM-0001 Name of the JLG WAM device as it appears on the Wi-Fi network (SSID) Password None WAM Password is not set Wireless Channel Channel the WAM device communicates with the Wi-Fi network Timeout 600 Seconds Inactivity timer - If communications has not occurred for xxxx seconds between the WAM and your phone or tablet, the WAM will disconnect the wireless connection Wireless Comm Rate 54Mbps Communication rate of the wireless connection # 1001147572 Front View 1. Power On LED 2. Connect LED 3. Data LED Rear View 4. Association LED 5. Reset to Factory Default Figure 2-1. Wireless Analyzer Module (WAM) 3121600 – JLG Lift – 2-1 SECTION 2 - WIRELESS ANALYZER MODULE - SETUP AND TROUBLESHOOTING Setting Wi-Fi Name (SSID) Setting Password In order to keep the WAM from conflicting with other WAM devices, you MUST first set the Name (SSID) of the WAM by doing the following: 1. Plug the JLG Wireless Analyzer Module into the analyzer port of any JLG machine equipped for the wired analyzer interface. 2. Using your phone or tablet connect to the JLG WAM, and start the JLG Analyzer application, but do not touch the connect button in the app. If you would like to add a password to the device you can do so by touching the area beside the password text. (Should bring up a keyboard). The password must not contain spaces and must be 32 characters or less. If you set a password record it and remember it! If you choose not to set a password touch the "Apply" button on the screen and wait, the module should update. Once finished, cycle power to the WAM by either cycling the E Stop on the machine you are plugged into, or unplugging and replugging the module into the analyzer connection. 3. Go into the Wireless Analyzer Module setup by touching the Setup button and then the "Wireless Settings" button. 4. In the Wireless Settings menu touch the area beside Name (Should bring up a keyboard). 5. Type in any name you want to associate with the WAM. The name must not contain spaces and must be 32 characters or less. 2-2 – JLG Lift – 3121600 SECTION 2 - WIRELESS ANALYZER MODULE - SETUP AND TROUBLESHOOTING 2.2 Troubleshooting the JLG Wireless Analyzer Module If you have trouble connecting the application to the JLG Wireless Analyzer Module, check the following: Table 2-2. WAM LED Status Table WAM Status LED Red Power LED (P) Red Connection LED (C) Green Data LED (D) Yellow Association LED (A) Device Not Connected to JLG Wireless Analyzer Module Device Connected to JLG Wireless Analyzer Module - Application not running Device Connected to JLG Wireless Analyzer Module - Application Running On On On Blinking Slow Blinking Slow On Off Off Blinking Blinking Fast Off Off Notes: 1. Try re-orienting the module. The module can be underneath open hood to protect it from environmental elements, but may not communicate, or communication distance may be severely affected if the module is underneath a closed metal hood. 2. Only one device can be connected to the JLG WAM at a time. If another device is connected you may receive a device cannot connect. If the device has been password protected and you do not know the password, you will not be able to connect to it. 3121600 – JLG Lift – 3. Make sure you have given the JLG Wireless Analyzer Module a unique name (SSID), as this will cause a conflict if there are two or more modules with the same name. 4. If there are many devices in range on the same channel this may cause intermittent communications between the device and the JLG Wireless Analyzer Module. See the Wireless settings section on how to change the communication channel on the JLG WAM. 2-3 SECTION 2 - WIRELESS ANALYZER MODULE - SETUP AND TROUBLESHOOTING 2.3 6. Power off the module. Replace the decal or cover the hole with tape. FACTORY DEFAULT - RESET The following is required to reset the JLG WAM to factory default settings. Read thoroughly before attempting a factory reset! 1. Initially, the module should be plugged into the machine with power off. NOTE: This will reset the module to defaults and require a reset of the Name (SSID) of the device. (Refer to Table 2-1, Default Wireless Analyzer Module Settings.) 2. Flip module over and remove decal to access the factory reset switch. (See figure 2.) 3. Insert a paper clip in the hole, and depress gently, you should feel the switch click. (You will be pressing and releasing the button several times in the following steps.) 4. With the switch depressed power on the machine. 5. Perform the following sequence at one second intervals: a. Release switch b. Depress switch c. Release switch d. Depress switch e. Release switch 2-4 – JLG Lift – 3121600 JLG Industries, Inc. 1 JLG Drive McConnellsburg PA. 172339533 USA (717) 485-5161 (717) 485-6417 3121600 JLG Worldwide Locations JLG Industries (Australia) P.O. Box 5119 11 Bolwarra Road Port Macquarie N.S.W. 2444 Australia +61 2 65 811111 +61 2 65 813058 JLG Latino Americana Ltda. Rua Eng. Carlos Stevenson, 80-Suite 71 13092-310 Campinas-SP Brazil +55 19 3295 0407 +55 19 3295 1025 JLG Industries (UK) Ltd Bentley House Bentley Avenue Middleton Greater Manchester M24 2GP - England +44 (0)161 654 1000 +44 (0)161 654 1001 JLG France SAS Z.I. de Fauillet 47400 Tonneins France +33 (0)5 53 88 31 70 +33 (0)5 53 88 31 79 JLG Deutschland GmbH Max-Planck-Str. 21 D - 27721 Ritterhude - Ihlpohl Germany +49 (0)421 69 350 20 +49 (0)421 69 350 45 JLG Equipment Services Ltd. Rm 1107 Landmark North 39 Lung Sum Avenue Sheung Shui N. T. Hong Kong (852) 2639 5783 (852) 2639 5797 JLG Industries (Italia) s.r.l. Via Po. 22 20010 Pregnana Milanese - MI Italy +39 029 359 5210 +39 029 359 5845 Oshkosh - JLG Singapore T. E. P. Ltd. 29 Tuas Ave 4 Jurong Industrial Estate 639379 Singapore +65-6591-9030 +65-6591-9031 Plataformas Elevadoras JLG Iberica, S.L. Trapadella, 2 P.I. Castellbisbal Sur 08755 Castellbisbal, Barcelona Spain +34 93 772 4700 +34 93 771 1762 JLG Sverige AB Enkopingsvagen 150 Box 704 SE - 176 27 Jarfalla Sweden +46 (0)850 659 500 +46 (0)850 659 534 www.jlg.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Annotate, Fill forms, Extract, Print high-res Author : TREEVES Create Date : 2015:04:08 08:08:02Z Modify Date : 2015:04:09 22:36:50-07:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : FrameMaker 10.0.2 Metadata Date : 2015:04:09 22:36:50-07:00 Format : application/pdf Title : 3121600.book Creator : TREEVES Producer : Acrobat Distiller 9.3.0 (Windows) Document ID : uuid:ed1d837c-636b-4473-8a0e-edf328dad23b Instance ID : uuid:03c03e12-84fc-447e-a8f5-8f90285dfc05 Page Mode : UseOutlines Page Count : 20EXIF Metadata provided by EXIF.tools