JiangSu HuiTong Group HTMD004A TL8269 Light Module User Manual
JiangSu HuiTong Group Co.,Ltd TL8269 Light Module
User Manual
Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential TL8269 LIGHT MODULE Specifications Datasheet Module supports: Module Part Number: Module # Module Name #1 TL8269 LIGHT MODULE Role Author Checked by Approved by Date: <31 July 2018> Name: Li Dan Nick Qiao Yin Zhi Lin Classification Confidential HT Part Number HTMD‐004A Appointment: Design Engineer PM – R&D CTO Version:Page 1 of 13 remark Signature: Status: Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential Revision History: Version Date (dd/mm/yyyy) Author Status Modifications V0.1 31/07/2018 Li Dan Draft Doc creation © Jiang Su HuiTong Group Co., Ltd All rights are reserved. The information presented in this document does not form part of any quotation, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights. Page 2 of 13 Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential 1 Introduction 1.1 Scope Module Module Name #1 HT P/N SOC Standard Supported TL8269 LIGHT HTMD‐004A TLSR8269F512AT32 Zigbee 3.0 MODULE Note: 1.2 Product Features Page 3 of 13 Bluetooth Standard Supported RF Frequency Interface to Module Band Host Size 2.4G (2.4 ~ 2.5 GHz) UART 22mm (L) x 15mm(W) 3.5mm(H) Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential Page 4 of 13 Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential Page 5 of 13 Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential Ambient Conditions: Operation Temperature: -10℃ ~ +120℃ Storage Temperature: -40℃ ~ +85℃ Operation Humidity: 10 ~ 90% RH Storage Humidity: 5 ~ 95% RH Environmental compliance: RoHS compliant REACH compliant Approbation: EU/ Russia: LATAM: TBC Page 6 of 13 Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential 2 Technical Specifications 2.1 Absolute Maximum Ratings: Stresses beyond these conditions listed below may cause permanent damage to the module. Parameters Maximum Rating Power Supply Voltage at +3V3 (-0.3 ~3.63)V Input voltage to IO pins (-0.3 ~3.63)V Storage Temperature Conditions –40 ℃ ~ +85℃. Storage Humidity conditions 5% to 95% (RH) ESD (HBM) 1000V 2.2 Recommended Operation Conditions Parameters Operation Conditions (–10 ℃ ~ +120℃) Operating Temperature - No performance reduction up 80°C ambient Temperature Conditions - No component failure up to 120°C ambient Temperature. Operating Humidity conditions 10% to 90% (RH) Page 7 of 13 Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential 2.3 Electrical Specifications Pre-test conditions: Operation Temperature = room temperature 25°C, unless otherwise noted. CTQ parameters are marked with *. Item Specifications/Requirement Parameters Test Conditions 2.3.1 Input power Test board 2.3.2 Power standby mA 2.3.3 consumption Active mA No. Min Typ 2.8V 3.3V Max Units 3.6V EN61000-3-2/3-3: ESD - IEC61000/4/2 : 8kV air 2.3.4 ESD - ANATEL 442 : 8kV air discharge Module is mounted into Final product casing at the designed No functional failures and no parts should suffer damage location. 2.4 RF Performance Pre-test conditions: 1) TX power is at typical level, measured at antenna feed point. 2) Front End Insertion loss ( including Balun, impedance mis-match+diplexer): 3) Operation Temperature = room temp erature 25°C, unless otherwise noted. 4) CTQ parameters are marked with *. 2.4.1 Zigbee RF Specifications Item No. Parameters 2405 nominal for 1 % PER, as per 2.4.2.1 receiver sensitivity 2.4.2.2 Test Conditions 802.15.4 2440 nominal for 1 % PER, as per 802.15.4 Page 8 of 13 Specifications/Requirement Min Typ Max Units -96 dBm -96 dBm Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential 2480 nominal for 1 % PER, as per 2.4.2.3 2.4.2.4 2.4.2.5 -96 dBm 2405 6.95 dBm 2440 6.60 dBm 2480 3.72 dBm 802.15.4 Power 2.4.2.6 2.5 Quality, Environmental and Reliability S/N Electrical Test Requirement 2.5.1 Dry heat Test 2.5.2 2.5.3 2.5.4 TEST CONDITION Temp. : +70℃ Test time : 96 hrs Low Temperature Temp. : -25℃ storage Test time : 96 hrs Temperature Temp. : -20℃ ~ +85℃, Duration : 30 min Shock Ramp-up & Ramp-down for 5 min, Cycle : 1,000cycle. Humidity Load Test 2.5.5 Vibration test 2.5.6 Cold Test Requirement 4 days 4 days 35 days Leave samples in 40℃±5℃, 90 ~ 95% RH for 21days, 21 days and in standard test condition for 30 minutes 10-55-10Hz / amplitude 0.35mm / sweep rate 1 octave per min. Operational/start up after min 4hrs at -10℃ 1 day 1 day Humidity 93%RH, 6h:temp from 25 ℃ to 40 ℃, 6hrs 2.5.7 Damp heat cyclic temp 40 ℃ to 25 ℃, 6hrs at 25 ℃, operational last 21 days hour only for 21 days. 2.5.8 Temperature step stress test 2.5.9 Operation Operational up to a temperature of 60 ℃ for 16 days 16 days Temp. : 60℃, 90% RH, MTBF 50,000 hrs 10 days Page 9 of 13 Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential Life(MTBF) 2.6 EMC Compliance and Certifications Region Regulation Standards Requirement Fulfill CE with official test report at EU/RU module level to meet the latest EMC requirement Fulfill approbation requirements, with official test report at Module LATAM: level 2.7 Environment Compliance RoHS compliant REACH compliant 3 Mechanical Drawing Page 10 of 13 Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential 3.1 Pin define 3.2 Mechanical Outline and dimensions Dimension (TOP View) Dimension (Side View) Page 11 of 14 Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential Dimension (Bottom View) 3.3 Actual Module image Page 12 of 14 Jiang Su HuiTong Group Co., Ltd Report No: HTMD-004 CLASSIFIED: Confidential FCC Statement: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment .This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. FCC Label Instructions: The outside of final products that contains this module device must display a label referring to the enclosed module. This exterior label can use wording such as: "Contains Transmitter Module FCC ID: PUW-HTMD004A or Contains FCC ID: PUW-HTMD004A " , Any similar wording that expresses the same meaning may be used. Page 13 of 13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : baclsh47 Create Date : 2018:10:22 16:12:52+08:00 Modify Date : 2018:10:31 14:22:05-07:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 11.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2018:10:31 14:22:05-07:00 Format : application/pdf Title : Microsoft Word - 2k18 Zigbee TL Light _HTMD-004_ Specifications Datasheet V0.1draft _temp Creator : baclsh47 Document ID : uuid:f5e99e39-abd5-4704-b0b6-6a12df02f3c1 Instance ID : uuid:0a0ff7b1-803b-4cbf-a803-393cbf412927 Page Count : 13EXIF Metadata provided by EXIF.tools