User manual-rev1
User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) User Interface Specification VDT985 (Project V1601) Vick’s Bluetooth Digital Stick Thermometer This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 1 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) Table of Contents Introduction ............................................................................................................................. 5 1.1 Purpose ......................................................................................................................... 5 1.2 Scope ............................................................................................................................ 5 1.3 References .................................................................................................................... 5 1.4 Terms and Abbreviations ............................................................................................... 5 Responsibilities ....................................................................................................................... 5 User interface .......................................................................................................................... 5 3.1 Device ID....................................................................................................................... 5 3.2 App ID ........................................................................................................................... 6 Device Workflow...................................................................................................................... 6 4.1 User action with thermometer workflow ......................................................................... 6 App Workflow .......................................................................................................................... 8 5.1 First Time App Launch: Terms, Privacy, & App Tour ....................................................... 8 5.2 TOUR: ........................................................................................................................... 9 If user selects TAKE TOUR from opening sequence, below app screens appear. .................... 9 5.3 First Time Pairing ........................................................................................................ 10 5.4 Home Screen (Take Temp) .......................................................................................... 11 5.5 Taking a Measurement ................................................................................................ 11 5.5.1 Enabling Bluetooth and Selecting Profile .......................................................... 11 If the APP is reopened after being closed, it will first make sure BT is enabled on the phone and then proceed to home screen. If BT is not enabled screen below will appear. User will enable Bluetooth on PHONE settings. User selects profile by using arrows to rotate carousel. ......... 11 5.5.2 Bluetooth and Thermometer status -Sequence to take Measurement ............... 12 5.5.3 Measurement complete .................................................................................... 14 5.6 Profiles ........................................................................................................................ 15 5.7 History ......................................................................................................................... 16 This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 2 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) .......................... 16 5.7.1 Add Manual Event............................................................................................. 17 5.7.2 Edit a Measurement .......................................................................................... 17 5.7.3 Exporting Data .................................................................................................. 18 5.8 Reminders ................................................................................................................... 18 5.9 “More Menu” functions................................................................................................. 19 5.9.1 Add new device ................................................................................................ 19 5.9.2 Settings (switch C/F) ......................................................................................... 19 5.9.3 Temperature Reference Chart ........................................................................... 20 5.9.4 App Tour ........................................................................................................... 20 5.9.5 User Manual ..................................................................................................... 20 5.9.6 Battery .............................................................................................................. 22 5.9.7 Tips and Advice ................................................................................................. 22 5.9.8 Vicks. Com........................................................................................................ 23 5.9.9 Browse All Products .......................................................................................... 23 5.9.10 Contact Tech Support........................................................................................ 24 5.10 LOW BATTERY INDICATOR ....................................................................................... 24 5.11 ERROR MESSAGES .................................................................................................. 24 This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 3 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 5.12 Revision 0 (last updated: 4-29-2015) 5.11.1 Low temperature display ................................................................................... 25 5.11.2 Ambient Error.................................................................................................... 25 5.11.3 System Error ..................................................................................................... 26 5.11.4 Premature Removal of Thermometer ................................................................ 27 5.11.5 Remove Thermometer Error ............................................................................. 28 Enter Water bath/Calibration mode .............................................................................. 28 InSight Tables (programmed into the app) ............................................................................. 28 6.1 US app Insight colors -No AgeSmart ........................................................................... 29 6.2 EMEA and CA app Insight colors –With AgeSmart....................................................... 29 Document Information and Approval...................................................................................... 30 7.1 Revision History .......................................................................................................... 30 7.2 Approval ...................................................................................................................... 31 7.3 Effective date:.............................................................................................................. 31 This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 4 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) INTRODUCTION 1.1 Purpose This document identifies and defines the tactile, visual, and audio interactions with the thermometer device and mobile app of the VDT985 consumer model Vicks Bluetooth Digital Stick Thermometer. 1.2 Scope Included in this UIS are the definitions of thermometer button functions, audio signals, light signals, user workflows and associated app display interactions for the VDT985 Bluetooth Digital Stick Thermometer. 1.3 References SOP-05000000 Design Control PRD-V1601 Product Requirements Document 1.4 Terms and Abbreviations Term/Abbreviation Definition UI User Interface S, sec Seconds RESPONSIBILITIES Program Manager- Distributes document to cross-functional team, files document in the Design History File and assigns team members for document approval. USER INTERFACE 3.1 Device ID This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 5 of 31 User Interface Specification VDT985 Incorporated Revision 0 Document No.: UIS-V1601 (last updated: 4-29-2015) O/I Button Green LED, Red LED 3.2 App ID App Icons Meaning 1. Bluetooth enabled indicator 2. Bluetooth NOT enabled indicator 1. 2. 1. 2. 1. Therm connected/paired indicator 2. Therm NOT connected/paired indicator Back button, brings user to previous screen (located in upper left-hand corner) More Info Anonymous measurement. Marks a saved temperature measurement that is saved in history but is not assigned to a profile. Symbol appears next to Bluetooth and thermometer icons in upper right and provides helpful information DEVICE WORKFLOW 4.1 User action with thermometer workflow EVENT/MODE USER ACTION AUDIO LED Power ON therm -User turns On thermometer by pressing the power button (when device is OFF) -User can press once or press and hold. -Unit cannot be turned off for 5 seconds 1 short beep Solid Green – About 1-2 seconds This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 6 of 31 User Interface Specification VDT985 Incorporated Revision 0 Document No.: UIS-V1601 Therm NOT paired (standby mode) st 1 time paring (last updated: 4-29-2015) after power on. User only needs to take action for first time paring. Subsequent pairing occurs automatically 1. Thermometer can be ON or OFF 2. User presses and holds down power button (while normal turn on LED sequence displays: green LED followed immediately by red blinking LED) 3. After exactly 3 seconds, red blinking light on thermometer will change to STEADY red light. none Blinking red (same as all errors) none. When user presses and holds power button normal turn on LED sequence occurs: solid green LED followed immediately by red blinking LED to indicate not paired status) Therm will change from blinking red to STEADY red after exactly 3 seconds. After user confirms STEADY red LED by pushing app button,, LED will change to GREEN. 4. App screen will prompt user to press “CONFIRM STEADY….” Button on app 5. Screen will show “Connecting” 6. When pairing has successfully completed, the thermometer’s green LED appears solid, and the therm is ready to use. Therm IS paired (standby mode) Initiate Measurement Measurement in progress Measurement Completes (no errors) None. (Therm is ready to take a measurement and communicate with app.) -User opens app and goes through take temp sequence on app. none Solid Green none -User should keep therm inserted until measurement completes. -User will see temp increasing on the app screen. -Power button is locked (therm cannot be powered off) until measurement completes User can remove thermometer and read temperature on app screen none Same as standby —Solid Green (if paired) or Blinking Red (if not paired) Blinking Green 1 long beep This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Back to standby —Solid Green (if paired) or Blinking Red (if not paired) Page 7 of 31 User Interface Specification VDT985 Incorporated Revision 0 Document No.: UIS-V1601 (last updated: 4-29-2015) Measurement Error Ambient Error Hi/Lo Temp Error System Error Error message will appear on app screen (See below for specific error message app screens.) 2 quick beeps repeated 5x (same as V966) 10% & 20% Low Therm Battery Less than 2.2 V Battery Low battery warning displays on app screen only. Dead battery warning displays on app screen only. none Power OFF therm Therm auto powers OFF 2 quick beeps repeated 5x (same as V966) -User presses power button (when device 1 short beep is ON, but not actively taking a measurement) -Cannot be powered off within 5secs of power on- do we still want this? Device powers OFF automatically after 1 short beep 2mins of continuous standby Steady RED appears on thermometer until Take temp button is pressed or user navigates away from error screen none Steady red LED off LED off Short beep ~0.5sec Long beep ~2 sec APP WORKFLOW 5.1 First Time App Launch: Terms, Privacy, & App Tour The following screen sequence illustrates the first time the app is opened after being downloaded. User is prompted to accept privacy policy, take tour and pair thermometer. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 8 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.2 TOUR: If user selects TAKE TOUR from opening sequence, below app screens appear. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 9 of 31 User Interface Specification VDT985 Incorporated Revision 0 Document No.: UIS-V1601 (last updated: 4-29-2015) 5.3 First Time Pairing HOLD button down until red light on thermometer stops flashing and becomes STEADY. VICKS Confirm STEADY red light on thermometer Bluetooth should be “ON” in phone, if not pop up will appear. User must go to phone settings to turn on Bluetooth. When BT is on, the App will prompt to pair thermometer with APP by HOLDing temp button until steady red light, then confirm red light by pressing app button and then therm will connect to app and user can begin to take measurements. After the first time use and thermometer has been paired, when the app is launched it will bring you directly to the Home screen (see below) after the splash page, skipping the rest of the first-time-use screens. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 10 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.4 Home Screen (Take Temp) Fig 1 Fig 2 Fig 3 Upon initial launch, App will prompt user to create profile in the profile carousel. It they want to take measurement without a profile, thet can choose to take a temperature without a profile. The measurement will appear in ALL HISTORY screen as an unassigned reading. 1st fig- shows HOME screen upon launch, 2nd fig, HOME screenone profile created, 3rd figHOME screen 2 profiles created) Icon with question mark is “no profile selected.” When a user presses on any of the bottom bar icons (Profiles, History, Reminders, & More) the user will be brought to that section of the app. See the relevant sections below for details. (5.6 Profiles, 5.7 History, 5.8 Reminders, 5.9 More Menu) The “Take Temp” icon in the bottom bar will always take users to the home page as shown above. The App prompts the user to create profile FIRST so that measurements can be logged against created profiles ot patients. 5.5 Taking a Measurement 5.5.1 Enabling Bluetooth and Selecting Profile If the APP is reopened after being closed, it will first make sure BT is enabled on the phone and then proceed to home screen. If BT is not enabled screen below will appear. User will This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 11 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) enable Bluetooth on PHONE settings. User selects profile by using arrows to rotate carousel. 5.5.2 Bluetooth and Thermometer status -Sequence to take Measurement Conditions at start of measurement (in order of hierarchy)… • If Bluetooth is not turned on when trying to take a measurement the app will provide a prompt to Enable Bluetooth. ( if user ignores prompt on 6.1 and presses OK, but does not change phone setting.) • The Bluetooth status icon in the upper right corner will be grayed out indicating that the phone’s Bluetooth is not enabled. • If the user presses the red question bubble pop-up next to the grayed out icon a window will pop-up detailing the problem. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 12 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 • Revision 0 (last updated: 4-29-2015) If the thermometer is off or the app does not detect the thermometer, the app will display the “Turn Thermometer On” prompt when trying to take a measurement. • The grayed out Thermometer status icon in the upper right corner, indicates that the thermometer is not connected. • If the user presses the red question bubble pop-up next to the grayed out icon a window will pop-up detailing the problem.1. no power, battery is dead, out of range, or device has lost pairing click on Add New Device • If the thermometer is ON and paired with the app, but not inserted when the measurement starts the app will display the “Insert Thermometer” prompt • (uses same animation as the Turn on Thermometer prompt) This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 13 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 • Revision 0 (last updated: 4-29-2015) If the thermometer is ON and paired and inserted properly the user will see the “Reading in progress” screen • This screen shows an active animation of the real time temperature being measured (displays increasing highest temperature) Full Measurement sequence 5.5.3 Measurement complete Measurement will appear in color relating to Fever Reference Chart. Profile, location and last 3 measurements of that profile will be displayed. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 14 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.6 Profiles User can create Profile from the Home screen by pressing the CREATE PROFILE button on the Carousel. They can also create profiles by pressing the profiles button on the bottom tab. When they press “create profile” the “Create a new profile” screen appears. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 15 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.7 History • Users can select to see ALL history or a date range of the history. • The History will always default to display in List view (as seen above). By clicking on “List/Graph” button, you can switch from viewing in List format or viewing in Graph format (as seen below). • The blue “Take temp” button goes to the “Home” screen (same as the Take Temp icon in the bottom gray bar) • The blue “Export” button allows user to send their data to an external source via email. (See “Export data” section for more details) This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 16 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 5.7.1 Revision 0 (last updated: 4-29-2015) Add Manual Event When user touches “Add Event” button on the History screen, they will be brought to the following screen, where they can manually enter the appropriate information for a temperature that may not have been taken with the VDT985. App will prompt for location if temperature is input. 5.7.2 Edit a Measurement When user touches “Edit/Add Info” next to reading on history screen, user can add, save, delete information or change the profile that the measurement was initially assigned to. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 17 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 5.7.3 Revision 0 (last updated: 4-29-2015) Exporting Data When user touches “Export” button on the History screen, they will be brought to the following screen, where she can select history range and export format and where to export information to. 5.8 Reminders When user touches “Reminder” tab on bottom of Home screen, they will be brought to the Reminder screen. User can create reminders that will be “pushed” to the phone and appear a on phone home screen. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 18 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.9 “More Menu” functions 5.9.1 Add new device Will enable user to pair or repair thermometers to the app. Will revert to First Time Pairing sequence. See section 5.3. 5.9.2 Settings (switch C/F) Allows you to switch the displayed temperatures between Celsius and Fahrenheit This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 19 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 5.9.3 Revision 0 (last updated: 4-29-2015) Temperature Reference Chart Will show below fever reference chart: 5.9.4 App Tour Will launch tour. Go to section 5.2 5.9.5 User Manual This tab will take you to the online Owner’s Manual. The content below will appear in this version of the Owner’s Manual. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 20 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.9.5.1 FCC Identification Number FCC ID: 2ABRGVDT985 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 5.9.5.2 FCC Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. 5.9.5.3 FCC Statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 21 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 5.9.6 Revision 0 (last updated: 4-29-2015) Battery Will enable user to pair or repair thermometers to the app. 5.9.7 Tips and Advice Will take user to this webpage: This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 22 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 5.9.8 Revision 0 (last updated: 4-29-2015) Vicks. Com Will take user to this webpage: 5.9.9 Browse All Products Will take user to this webpage: This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 23 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.9.10 Contact Tech Support Will direct users to http://www.vickshumidifiers.com/support 5.10 LOW BATTERY INDICATOR When battery has 10% life left, App screen will display: “WARNING! Thermometer has 20% battery life remaining. Please replace with CR2032 battery.” When battery has less than 2.2.V, App screen will display: “REPLACE BATTERY! Thermometer battery has run out. Please replace with CR2032 battery.” 5.11 ERROR MESSAGES When measured temperature is higher than 42.9°C or 109.22, the App will display “INVALID MEASUREMENT Please remove thermometer for 8 seconds and reinsert to start another measurement.” This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 24 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.11.1 Low temperature display When measured temperature is below 89.6F or 32C App will display: “INVALID MEASUREMENT Please remove thermometer for 8 seconds and reinsert to start another measurement.” 5.11.2 Ambient Error When ambient temperature is BELOW 50F or 10C, the App will display: “ENVIRONMENT TOO COLD. Please move to a warmer temperature for 15 minutes and try again.” When ambient temperature is ABOVE 104F or 40C, the App will display: “ENVIRONMENT TOO HOT. Please move to a warmer temperature for 15 minutes and try again.” This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 25 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) If ambient temperature is in the same range as human temperature (89-108F) AND thermometer has not detected insertion or removal (temp change) within 20 seconds, App will display button screen below. User presses button to initiate thermometer to take reading. (Scenario- if ambient temperature is exactly same as human body measured temperature, thermometer will not know when to take a reading.)) 5.11.3 System Error When a system error occurs such as a short or broken circuit, the app displays “Please call customer service at 1-800-477-0457” (Clickable- to dial out.) This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 26 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.11.4 Premature Removal of Thermometer If user removes thermometer before measurement is complete, App will display…”Error. Please reinsert thermometer and wait for confirmation beep.” This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 27 of 31 User Interface Specification VDT985 Incorporated Document No.: UIS-V1601 Revision 0 (last updated: 4-29-2015) 5.11.5 Remove Thermometer Error If a reading has already been completed AND the thermometer has not detected insertion or removal of thermometer (temp change), the App displays: “REMOVE THERMOMETER Please remove thermometer for 8 seconds and reinsert to start another measurement.” (Scenario-If user tries to take another temperature right after a measurement, but doesn’t remove thermometer 5.12 Enter Water bath/Calibration mode JIM/DANIEL TO INPUT INSIGHT TABLES (PROGRAMMED INTO THE APP) For all of the following tables: Temperatures below the “No color” range or above the “Red” range will not display a temperature value, and instead will show an error message on the app. The device will also display the red blinking error LED and beeps. This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 28 of 31 User Interface Specification VDT985 Incorporated Revision 0 Document No.: UIS-V1601 (last updated: 4-29-2015) 6.1 US app Insight colors -No AgeSmart No Color Site Yellow Green Scale (but temp (Healthy Temperature) displays) ≥89.6 ≤96.3 °C ≥32.0 ≤35.7 >35.7 ≤37.4 Under °F ≥89.6 ≤96.1 >96.1 Arm °C ≥32.0 ≤35.6 °F ≥89.6 °C ≥32.0 Rectal (Elevated) Elevated) >96.3 ≤99.4 >99.4 JIM/DANIEL TO CHECK °F Oral Red (Slightly ≤101.3 >101.3 ≤109.2 >37.4 ≤38.5 >38.5 ≤99.2 >99.2 ≤101.1 >101.1 ≤109.2 >35.6 ≤37.3 >37.3 ≤38.4 >38.4 ≤97.2 >97.2 ≤100.3 >100.3 ≤102.2 >102.2 ≤109.2 ≤36.2 >36.2 ≤37.9 >37.9 >39.0 ≤39.0 ≤42.9 ≤42.9 ≤42.9 6.2 EMEA and CA app Insight colors –With AgeSmart Site Age No Color Green Range (but temp displays) (Healthy Temperature) ≥96.4°F Yellow Red (Slightly Elevated) (Elevated) or ≤3 <96.4°F or ≥35.8°C months <35.8°C ≤99.4°F or >99.4°F or N/A >37.4°C ≤37.4°C >3 Oral ≥95.7°F or >99.6°F or months <95.7°F or ≥35.4°C >37.6°C >101.3°F or ≤ 36 <35.4°C ≤99.6°F or ≤101.3°F or >38.5°C ≤37.6°C ≤38.5°C ≥95.7°F or >99.9°F or > 37.7°C >103.0°F or ≤103.0°F or >39.4°C months JIM/DANIEL TO CHECK >36 <95.7°F or ≥35.4°C months <35.4°C ≤99.9°F or ≤ 37.7°C Site Age No Color Range (but temp displays) Green (Healthy Temperature) ≤39.4°C Yellow Red (Slightly Elevated) (Elevated) This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 29 of 31 User Interface Specification VDT985 Incorporated Revision 0 Document No.: UIS-V1601 (last updated: 4-29-2015) ≥96.2°F or ≤ 3 months <96.2°F or ≥35.7°C <35.7°C ≤99.2°F or >99.2°F or N/A >37.3°C ≤37.3°C >3 months Underarm ≤ 36 months Site or ≥95.5°F <95.5°F or ≥35.3°C >37.4°C <35.3°C ≤99.4°F or ≤101.1°F or ≤37.4°C ≤38.4°C ≥95.6°F or >99.4°F or >36 <95.6°F or ≥35.3°C >37.4°C months <35.3°C ≤99.4°F or ≤ ≤102.9°F or ≤ 37.4°C 39.4°C Age No Color Range (but temp displays) (Healthy Temperature) ≤3 Green <97.3°F or ≥97.3°F <36.3°C ≥36.3°C months ≥96.6°F >38.4°C >102.9°F or >39.4°C Red (Slightly Elevated) (Elevated) >100.3°F or >37.9°C TO CHECK or >100.5°F or months <96.6°F or ≥35.9°C >38.1°C >102.2°F or ≤ 36 <35.9°C ≤100.5°F or ≤102.2°F or >39.0°C ≤38.1°C ≤39.0°C months ≥96.6°F or >36 <96.6°F or ≥35.9°C months <35.9°C ≤100.8°F or >100.8°F or > ≤ 38.2°C or Yellow N/A ≤100.3°F or >3 >101.1°F or JIM/DANIEL ≤37.9°C Rectal >99.4°F or 38.2°C >103.9°F or ≤103.9°F or ≤ >39.9°C 39.9°C DOCUMENT INFORMATION AND APPROVAL 7.1 Revision History Old New Rev Rev Originator/ Change Author Description 7/25/2014 Katie Sofia Initial Release 2-13-2015 Zoey Juhng Date This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 30 of 31 User Interface Specification VDT985 Incorporated Revision 0 Document No.: UIS-V1601 2_13_2015 Zoey Juhng 4_21_15 Zoey Juhng 4_28_15 Zoey Juhng 4_29-15 Zoey Juhng (last updated: 4-29-2015) 7.2 Approval 7.3 Effective date: Approval signatures are filed at Document Control Function Program Management Name Zoey Juhng Marketing (US) Lynne Hammell (Canada) Marketing (EMEA) Research and Development (PE) Operations (Microlife) Date Daniel Lawton Industrial Design Marketing Signature Bhawna Sharma Julien Charriere Gary Hu Willis Chan Regulatory? Raj K Quality? Billy Li This document is the property of Kaz, Incorporated. It is lent and is to be returned upon request. The contents of this document are confidential and constitute trade secrets proprietary to Kaz, Incorporated. Neither this document nor its contents shall be disclosed to any unauthorized person, copied or published without Kaz, Incorporated prior written consent. TEM-04030101 Rev 1 Effective Date 30-APR-2009 Page 31 of 31
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 31 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:72733f2d-08cc-11e5-0000-7b1f8fd20705 Producer : GPL Ghostscript 9.05 Keywords : () Modify Date : 2015:05:30 10:09:33+08:00 Create Date : 2015:05:30 10:09:33+08:00 Creator Tool : PDFCreator Version 1.6.2 Document ID : uuid:72733f2d-08cc-11e5-0000-7b1f8fd20705 Format : application/pdf Title : UIS-V1601 Creator : john.meng Description : () Author : john.meng Subject :EXIF Metadata provided by EXIF.tools