AWS RRH User Manual
AWS RRH User Manual
Written by
Reviewed by
Approved by
Jinhee Lee
Kshin
Michale Yoon
AWS RRH User Manual
Index
Contents
1.
2.
3.
4.
Test Environment 3
Network Configuration
Output Spectrum 6
Install Guide 6
AWS RRH User Manual
1. Test Environment
1.1. Preperation List

KMW AWS RRH (Remote Radio Head 2110 ~ 2155MHz)

PSU (Power Supply Unit)

D2U (Alacaltel Lucent)

Optic transceiver 2EA Optic Cable

Ehternet Cable

Laptop computer
1.2. Testing Environement Configuration

PSU Setting Table
Voltage
Current Limit
Normal : -48V
14 A
AWS RRH User Manual
1.3. RRH Setup Procedure

Checke PSU Power 48V off

Connect PSU power to RRH Power connector

Connect D2U and RRH with Optic transceiver and Optic cable

Turn on PSU to power up RRH

Make sure computer to join RRH and D2U network.
If the computer joined the same network which BBU joined, it is able to access RRH network from the GUI.
AWS RRH User Manual
2. Network Configuration

Setup computer network configuration
IP: assigned by ALU (ex; 10.10.10.55)
Subnet mask: 255.0.0.0
Default gateway: assigned by ALU (ex; 10.10.10.1)
DNS: assigned by ALU

Test network configuration
Windows Start > Run > CMD [Enter]
C:\> ping RRH IP(10.14.0.196) [Enter]
AWS RRH User Manual
3. Output Spectrum

If you set up Signal Analyzer, you can monitor carrier power just like below image.
4. Install Guide
Alcatel-Lucent RRH2x60-B4 Installation Guide
Issue
Date
Change
0.01
March 3, 2014
First draft
0.02
March 10, 2014
Updated for
comments
Legal notice
Alcatel, Lucent, Alcatel-Lucent , and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the
property of their respective owners.
Th
ti presented
t d iis subject
bj t tto change
ith t notice.
ti
Al
t lL
t assumes no responsibility
ibilit ffor iinaccuracies
The iinformation
without
Alcatel-Lucent
contained herein.
Copyright © 2014 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or
copied or used by anyone outside Alcatel-Lucent without its written authorization.
Al t l L
t RRH 2
60 B4 IInstallation
t ll ti G
id
Alcatel-Lucent
2x60-B4
Guide
C Alcatel-Lucent
Alcatel-Lucent RRH 2x60-B4
– Internal
Alcatel-Lucent – Internal
Proprietary – Use pursuant
to
Company instruction
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
3MN-01520-0002-RJZZA
March
2014 March 2014Sheet
Issue
0.02
1 of 24
Mandatory documents
Document number
Title
3MN-01520-0001-RJZZA
Alcatel-Lucent RRH2x60-B4 – Site Preparation Guidelines
Related Documents
Document number
Title
3MN-01520-0003-DEZZA Alcatel-Lucent RRH2x60-B4 – Technical Description
Terminology
In this document, Alcatel-Lucent Remote Radio Head 2x60-B4 is referred to by its abbreviated name, “AlcatelLucent RRH2x60-B4,” its shortened name, “RRH2x60-B4,” and may be generically referred to as the Remote
Radio Head (RRH).
Technical support
If you are unable to successfully complete any of the product-specific installation procedures in this document,
contact Alcatel-Lucent
Alcatel Lucent technical support before proceeding.
For technical support, contact your local Alcatel-Lucent customer support team. See the Alcatel-Lucent Support
web site (http://www.alcatel-lucent.com/support/) for contact information.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 2 of 24
1. Safety - General precautions for installation procedures
The following general precautions must be observed for installation procedures.
WARNING
Personal injury hazard
Failure to observe these safety precautions may result in personal injury or damage to equipment.
g to equipment,
q p
g instructions:
To avoid p
personal injuryy or damage
observe the following
• Read and understand all instructions.
• Follow all warnings and instructions marked on this product.
• Installation and maintenance procedures must be followed and performed by trained personnel only.
• Grounding and circuit continuity is vital for safe operation of the equipment. Never operate the equipment with
grounding/bonding
di /b di conductor
di
disconnected.
• The equipment must be provided with a readily accessible disconnect device as part of site preparation.
• This equipment is intended for installation in restricted access locations where access is controlled or where access
can only be gained by service personnel.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 3 of 24
1. Safety – Specific hazards
DANGER
DANGER
Laser
hazard
El t i shock
h kh
Electric
hazard
This equipment operates with invisible laser radiation.
Laser radiation can cause considerable injuries to the
eyes.
ffiber or into an
Never look into the end off an exposed
open optical connector when the optical source is
switched on. Always observe the laser warning
instructions.
CAUTION
Laser hazard
Use of controls or adjustments or performance of
procedures other than those specified herein may
result in hazardous laser radiation exposure.
Do not view directly into the laser beam with optical
instruments such as a fiber microscope because
viewing of laser emission in excess of Class 1 limits
significantly increases the risk of eye damage.
Never look into the end of an exposed fiber or an open
connector as long as the optical source is switched on.
Ensure that the optical source is switched off before
disconnecting optical fiber connectors.
Working in severe weather can result in personal
injury or death and damage to the equipment.
Never install or perform maintenance during severe
g winds, lightning,
g blizzards, hurricane
weather ((high
etc.).
WARNING
Electric shock hazard
Some parts of all electrical installations are
energized. Failure to follow safe work practices and
the safety warnings may lead to bodily injury and
property damage.
For this reason, only trained and qualified personnel
(electrical workers as defined in IEC 60215 or EN 60215
+ A1 or in the National Electrical Code or in ANSI/NFPA
No. 10) may install or service the installation.
DANGER
Lightning
g strike hazard
Lightning strikes are possible during stormy weather,
and could result in death or severe injury.
Do not work on the installation itself or on the power
supply lines or antenna feeders of an antenna during
stormy weather.
weather
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 4 of 24
1. Safety – Specific hazards (continued)
DANGER
NOTICE
N i
b t
Noxious-substance
hazard
T l hazard
Tools
Use of unspecified cleaning agents can result in
personal injury.
Use only specified cleaning agents. Never use
fflammable solvents.
Always ensure there is adequate ventilation in the
work area and wear the appropriate personal
protective equipment.
Tools left in the working area can cause short circuits
during operation which can lead to the destruction of
units.
ffinishing
g yyour work that no tools,
Make sure after
testing equipment, flashlights, etc., have been left in
or on the equipment.
NOTICE
Equipment
q p
safety
Corrosive-substance hazard
Safety information for this equipment can be found on
various Caution, Warning, Danger, information labels or
instructions affixed to or included with the AlcatelLucent RRH2x60-B4, its internal assemblies or included
within this document. Informational and cautionaryy
labels may appear near the item they address or may
be grouped in a single location on the equipment.
Warnings are typically adjacent to the hazard that is
noted on the label. The instructions, cautions and
warnings found on these labels must be understood and
db
ll personnell involved
l d with
h the
h equipment
observed
by all
installation and maintenance.
Cleaning plastic containers and lids with abrasive and
aggressive cleaning agents may cause permanent
damage.
Do nott use solvents,
t paraffin,
ffi abrasive
b i or aggressive
cleaning fluids, abrasive or aggressive antiseptic
agents or abrasive or aggressive materials.
CAUTION
Lifting
hazard
Lifting this equipment by yourself can result in injury
due to the size and weight of the equipment.
Always use at least two people or a lifting device to
position this equipment.
q p
move or p
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 5 of 24
3. Tools, materials, and prerequisites – Required materials, supplies needed
The following
master list of all supplies
that mayy be utilized during
g is an alphabetical
pp
g the installation of the RRH:
• Antioxidant compound
• Cable labels (to label both ends of cables before routing and installing cables)
• Lacing cord, waxed #50
• Power cable (customer provided,
provided must meet product-specific DC power requirements)
• Red tape or tags — 145C or equivalent, for tagging of DC power cables
• Silicone caulk
• Tape — Electrical
• Tie
Ti wraps
• Twine
• Wall anchors
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 6 of 24
2. Product overview – physical interfaces
Solar Shield
Bottom view
CPRI-1
Status LED (primary)
CPRI-2
(secondary)
GND
GND
-48V
DC IN
AISG
(output)
alarms ports
Rx3
TxRx1
TxRx2
Rx4
Notes:
Solar shield now shown in these views
GND = Protective Earth (PE) ground
ground, located on
lower right side and lower right side of RRH (when
facing front of RRH)
Alcatel-Lucent RRH 2x60-B4
Rear view
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 7 of 24
3. Tools, materials, and prerequisites – Required tools
The following is an alphabetical master list of all tools that may be utilized during the installation of the
external interfaces:
● Crimping tools 22-16 gauge, 10-4/0 gauge (5-120 mm2) for installation of terminal lugs and c-taps
● Electrical conduit installation equipment and materials ● ESD wrist strap
● Eye protection gear — Safety goggles or glasses (R-3055)
g rubber lineman's ggloves
●G
Gloves — Low-voltage
((R-4285))
● Heat gun for heat shrink tubing ● Insulated hand tools (for completing electrical connections)
● M10 eye bolts or hoisting rings ● Measuring tape
● Nut driver set (Imperial) with 10-inch extension ● Nut driver set (metric) with 250-mm extension
● Ohmmeter (multi-meter,
(multi meter volt/ohmmeter
volt/ohmmeter, or equivalent)
● Screwdrivers (power and manual), flat-blade, Phillips and Torx
● Small, regular, slip-joint pliers ● Tongue-and-groove, slip-joint pliers
● Socket sets (Imperial and metric) various drives, including 1/4" socket for security bit
● Stripping tool (for LDF4 antenna jumper cables) - part number 74Z-0-12-15 for Huber Suhner connectors;
- part number ITE-7189 for Andrew connectors.
● Tie wrap tool ● Torque wrenches, 2 - 34 N·m(17.7 - 300 lbf-in)
● Torque wrenches, 6 - 200 N·m (4.4 - 150 lbf-ft)
● Wire cutter [capable of cutting up to 50 mm2 (1/0 AWG)] ● Wire stripper
● Wrench — Adjustable, (20 mm / 3/4 inch) open-end wrench (or set of fixed open-end wrenches)
- If fixed open end wrenches are used, both metric (mm) and Imperial system (in) wrenches will be
needed.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 8 of 24
3. Tools, materials, and prerequisites – Required materials, parts list
Required installation parts list
Item
Part No.
Description
Qty.
Comments
3JR52709AA
Alcatel-Lucent RRH2x60-B4
Includes RRH with Solar shields and
mounting bracket
See note 1
Pole mounting kit
Optional: Required only for pole mounting
1AB435070001
DC power plug,
plug circular,
circular 2-pin
1 required per RRH
RRH, used with power cable
301022679
Ground lug kit (kit WES bag)
Required for protective Earth (PE) ground
See note 2
SFP transceiver, SMDF or MMDF, LC connector
1 required per CPRI connection
See note 3
Optical fiber, SMDF or MMDF, LC-LC connectors
1 required per CPRI connection
1AB027220001
R2CT weatherized plug
1 required per CPRI connection
See note 3
RF cable, coax, DIN male-DIN male/loose
1 to 4
1 required for each antenna connection used
See note 3
User alarm cable, 4 pair, circular DIN male on one end
1 or 2
Optional: Required for external user alarms
10
See note 3
AISG connection cable, 8-pin circular DIN
Optional: Required for AISG daisy-chain
connection
11
12
Notes:
1. Part number depends on pole size
2. Part number depends on CPRI rate required
3. Part number depends on length required
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 9 of 24
3. Tools, materials, and prerequisites – Prerequisites
Verify site preparation and physical installation are completed: (see Alcatel-Lucent RRH2x60-B4 – Site
Preparation Guidelines, 3MN-01520-0001-RJZZA):
Before installation of the Alcatel-Lucent RRH2x60-B4 site can begin, site preparation must be completed.
The following site preparation general requirements must be met before the installation of the Alcatel-Lucent
RRH2x60-B4 can begin:
● Adequate clearance must be provided for service access
● DC electric service (with a readily accessible disconnect device ) must be installed
● User alarm facilities must be installed ● Grounding electrode system must be installed and tested
● RF and antenna runs must be installed (if required) ● Surge protection for antennas must be installed (if required)
● Tower light power must be installed (if required) ● Tower light alarm must be installed (if required)
● The environment must comply with limits listed under Environmental requirements in the Alcatel-Lucent
RRH2x60-B4 – Site Preparation Guidelines, 3MN-01520-0001-RJZZA
● Cable supports and racks must be installed ● Conduit for DC power must be installed when applicable
Installation p
procedure checklist
Done
N/A
Task
5-1: Install RRH on a pole
5-2: Install RRH on a wall
5-3: Procedure to change
to Type
g from Type
yp A configuration
yp B
5-4: Connect protective earth (PE) ground
5-5: Connect optical fiber cables
5-6: Route and connect user alarm cables (optional)
5-7: Route and connect AISG cable ((optional)
5-8: Route and connect RF cables (optional)
5-9: Connect DC power cable
5-10: Final checks prior to installation
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 10 of 24
4-1. Pre-installation steps - Preparing the RRH
CPRI-2
Step 1
Remove the optical port cover.
Step 2
Install the optical transceiver in the right slot.
Step 3
Place the cover of the optical port back to protect the
port.
CPRI1
NOTE: if only one optical port is used,
used insert the
transceiver in CPRI1
Note: Clean and inspect the
LC connectors on the CPRI
fiber optic cable before
connecting to SFP.
4-2. Handling the RRH
Packing Foam
1- Always use the handle fitted onto the RRH body
2- Protect the side facing the ground with packing foam
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 11 of 24
Required materials
5-1. Install RRH on a pole
Note: The RRH is shipped with the Wall Mounting Bracket
and the solar shields installed ((in Type
yp A configuration.)
Step 1
Remove the mounting bracket from the RRH by loosening
the four M8 side screws (see arrows). Do not completely
remove the screws from the holes.
Description
Qty.
3JR52709AA
Alcatel-Lucent RRH2x60-B4
Depends on
pole size
Pole mounting kit
Step
Attach half of each pole clamp to the back of the Mounting
Bracket using two M10x25 screws in the center holes, upper
and lower.
Pole clamp
Mounting
Bracket
Part No.
Step 3
With the M10 flanged nut installed on one end of the M10
threaded rod, pass the threaded rod through both the upper
and lower outer holes of the Mounting Bracket.
Step 4
Pl
Place
th
the assembly
bl against
i t th
the pole
l and
d place
th
the rear
halves of each pole clamp, and secure with M10 flanged
nuts.
Note: Ensure the mounting bracket is level.
M8 Side screws
(Loosely
installed
before hanging)
Step 5
Hang the RRH on the Mounting Bracket and tighten the four
M8 side screws.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 12 of 24
5-2. Procedure to change from Type A configuration to Type B
Note: The RRH is shipped with the Mounting Bracket installed in Type A configuration (on the same side as the
antenna connectors). To convert to Type B configuration (Mounting Bracket on opposite side of antenna connectors).
Step 1
Remove the mounting bracket from the RRH by loosening the
four M8 side screws. Do not completely remove the screws
from the holes.
holes
Step 4
Flip over the RRH so the antenna connector side is up.
Step 2
Remove the solar shields by removing four M5 screws for
each solar shield. Keep the screws.
M5
Screws
Step 5
Install the solar shield using four M5 screws for each solar
shield.
M8
Screws
Step 3
Remove the 8 M5 “filler” screws , then insert the 8 M5
“filler” screws in the holes in the locations above where
they were installed.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
M5 “filler” Screws
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 13 of 24
Required materials
5-3. Install RRH on a wall
Note: The RRH is shipped with the wall Mounting Bracket installed (in
Type A configuration). For wall mounting, the Mounting Bracket must be
t d to
t T
fig ti
SSee 4
2 Procedure
tto change
h g ffrom
converted
Type B configuration.
4-2
Type A configuration to Type B.
Part No.
Description
Qty.
3JR52709AA
Alcatel-Lucent RRH2x60-B4
N/A
Wall anchors (customer provided)
Step 5
Torque each M8 side screw (4 total) to 15.3
Nm (135 in-lb).
Mounting bracket
(front view)
Step 1
Install a wall anchor in each mounting hole, tighten each anchor nut
to secure anchor to wall, and remove anchor nut and washers.
Step 2
Install wall mounting bracket on anchor studs, install anchor
washers and nuts, tighten each anchor nut to secure wall mounting
bracket to wall.
Note: Ensure the mounting bracket is level.
M8 Side screws
(Loosely installed
before hanging)
Step 3
Loosely install M8 side mounting screws on both sides of the RRH.
Step 4
Carefully raise RRH into position on mounting by inserting the M8
side screws into the slots on mounting bracket.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 14 of 24
Required materials
4-4. Connect protective Earth (PE) ground
Part No.
Description
Qty.
301022679
Ground lug kit (kit WES bag)
Step
p1
Route the 35 mm2 (#2 AWG) ground cable pigtail from
the ground system (installed during site preparation) to
the PE ground pad located on the lower right side or the
lower left side of the RRH.
Alcatel
Lucent RRH 2x60
B4 PE ground
Alcatel-Lucent
2x60-B4
Front
side
M6 bolts
GND
Wall or
pole
l side
id
Step 2
At the RRH end, cut the ground cable to the proper
length and strip the end of the cable.
Step 3
Crimp the 35 mm2 (#2 AWG) two-hole lug (from the
ground lug kit) onto the end of the ground cable. Clean
the contact surface area and use antioxidant to prevent
oxidation.
id ti
Step 4
Connect the ground lug to the RRH PE ground pad
using the supplied M6 bolts, lock washers, and flat
washers. Use antioxidant at the ground pad.
Step 5
Torque each bolt to 5.6 N·m (50 lbf-in).
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 15 of 24
Required materials
4-5. Connect optical fiber cables
Part No.
NOTICE
Description
Qty.*
SFP transceiver, SMDF or
MMDF , LC connector
Protect fiber cable
Depends on length
Mishandling fiber optic cable can result in damaged and nonfunctioning cables.
Optical fiber, SMDF, LC-LC 1
connectors
1AB027220001
R2CT weatherized plug
The optical cable is very sensitive, take the maximum precaution when
installing it. The optical fiber should be protected in solid pipe. Do not
use cable ties on the fiber cable. Do not cut this cable on site, excess
length should be coiled inside the eNodeB. The fiber optic connector
should be protected by a cap when not being used. Respect the
bending radius during the manipulation of optical cable (82.5 mm).
CPRI-1
CPRI-2
*Notes:
1.
1 The
Th CPRI daisy
d i chain
h i configuration
fi
ti is
i nott
supported in the initial release (LR14.1.L); it will
be supported in a future release.
2. When the CPRI daisy chain configuration is
supported and needed, Qty = 2 for all items and
repeat Steps 1 through 3 to connect the CPRI-2
port to the next RRH.
RRH
Step 1
If not previously installed, install and route a fiber optic
cable from the CPRI-1 port on the bottom of the RRH to the
eNodeB.
Note: The CPRI-1 port is accessed with the left hand
from the rear (pole-side) of the RRH.
Step 2
Remove protective cover from CPRI-1 port.
Step 3
If not previously installed, remove protective cover from
SFP, insert into CPRI-1 port, and lock SFP into place.
Note: Clean and inspect the LC
connectors on the CPRI fiber optic
cable before connecting to SFP.
Alcatel-Lucent RRH 2x60-B4
R2CT coupling nut
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 16 of 24
5-4. Connect optical fiber cables (continued)
Step
p4
Using the assembly instructions provided with the R2CT weatherized plug, assemble the R2CT plug onto the SMDF optical
fiber and connect to CPRI-1 port.
Step 4A
Using your left hand, connect the R2CT plug body to the CPRI-1 port receptacle as follows:
Align arrow on plug body with
alignment mark on receptacle.
Insert plug body bayonet pins
into slots on receptacle.
Rotate the plug body counterclockwise to lock it into place.
Protective
covers
LC
connector
The base of the plug body should be
on the left, as shown in the picture.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 17 of 24
5-5. Connect optical fiber cables – Step 4 (continued)
Step
p 4B
Remove the protective covers from the LC connector. Clean and inspect the LC connectors on the CPRI fiber optic cable.
Step 4C
Using your left hand, connect the fiber optic cable to the CPRI1 port SFP transceiver as follows:
Gently insert the LC connector into the SFP
transceiver until it “clicks” into place.
Gently pull on the LC connector to verify
that it is locked into place.
Step 4D
Using your left hand, carefully slide the coupling nut over the R2CT plug body and
rotate counter-clockwise
counter clockwise to lock it into place on the CPRI1 port receptacle
receptacle.
Step 4E
If not secured previously, manually thread the nut spiral onto the R2CT plug body and
torque to approximately 3.5 N·m (31 lbf-in).
N t spiral
Nut
i l
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 18 of 24
5-6. Route and connect user alarm cables (optional)
Step 1
Install and route the alarm cables from the alarm ports to the alarm
distribution frame.
Required materials
Part No.
Description
Qty.
Depends on
length
User alarm cable, 4 pair,
circular DIN male on one end
1 or
Connector pin configuration
Step 5
Plug the alarm cable connectors into the alarm ports
and hand tighten the outer connector shell to secure
the
h cables.
bl
Alarm cable terminal configuration
alarm
(output)
Step 2
Connect the alarm cables to the distribution frame.
Step 3
Using an ohmmeter or multi-meter, verify the continuity between the alarm
(DF)
cable connector pins and the distribution frame (DF).
Note: This measurement is performed on the alarm cable connector
(RRH side) with a loop back of each pair (one by one) on the alarm DF
side. Using a multi-meter, check that no short circuit appears between
each pair and the shielding wires.
Step 4
Remove the protective cover from the alarm ports on the RRH.
Pin
Designation
User_ALM_4_P
User_ALM_3_RTN
User_ALM_1_P
User_ALM_2_RTN
User_ALM_2_P
User_ALM_4_RTN
User_ALM_3_P
User_ALM_1_RTN
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 19 of 24
5-7. Route and connect AISG cable (optional)
Step
p1
Install and route the AISG cable from the AISG port on the bottom of the
RRH to the respective AISG controller or external antenna line device
(ALD) port.
Required materials
Part No.
Description
Qty.*
Depends on
length
AISG connection cable, 8pin circular DIN
Connector pin configuration
AISG cable terminal configuration
AISG
(output)
Note: AISG OUT ports have
female pins.
Step 2
Remove the protective cover from the AISG port on the RRH.
Note: To connect an AISG cable to the AISG port, plug the AISG
cable into the AISG port and hand tighten the outer connector
shell to secure the cable.
Step 3
Connect the AISG output port to the AISG IN port of another ALD.
Pin
Designation
+12 V DC output
-48 V DC output
RS485 B
RS485 GND
RS485 A
+10 V to +30 V DC output
DC return
N/C
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 20 of 24
5-8. Route and connect RF cables (optional)
Step
p1
Install and route the RF cables to the RF ports on the top
of the RRH.
Important! Ensure that RF cable shield grounding
has been completed for all antenna cables.
Required materials
Part No.
Description
Qty.
Depends on
length
RF cable, coax, DIN maleDIN male/loose
1 to 4
Step 2
Providing adequate slack, cut each cable so it reaches its
corresponding RF antenna connector or, if applicable, its
corresponding RF surge protector.
Rx3
TxRx1
TxRx2
Step 4
Remove the protective covers from the RF ports on the
RRH.
RRH
Rx4
Step 3
Terminate the end of each cable with the supplied 7/16
DIN connector.
Step 5
Connect each RF antenna cable to its corresponding RF
port on the RRH.
Note: RF surge protectors are optional.
optional
Step 6
Torque each 7/16 male DIN connector to 25 N·m (221 lbfin), at both ends (RRH and antenna) of each RF cable.
Important! Hold the body of the connector (part
connected to the coaxial cable) with a 22 mm openend wrench. Torque the rotating nut with a 32 mm
open-end wrench.
Step 7
Secure the RF cables along their route.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 21 of 24
5-9. Connect DC power cable
DANGER
Required materials
Part No.
Description
Qty.
1AB435070001
DC power plug, circular, 2-pin
N/A
cable customer provided 1
Power cable,
Electric shock hazard
Contact with energized network element power supply
lines can result in serious personal injury.
Ensure that the DC power is OFF and secured against
turn-on before completing this procedure.
Step 2
Conductors must be within an outer jacket to work with this
DC plug
Step 3
Cut the DC power cable to an appropriate length and strip
the ends of the wires.
-48V DC
Step 4
St
Using the assembly instructions provided with the DC power
plug, attach the DC power cable to the DC power plug as
follows :
• Pin A to -48V
• Pin B to 0V (-48V return)
Rear view of
DC power
plug body
Step 5
Plug the DC power cable into the -48 V DC IN port and hand
tighten the o
outer
ter connector shell to sec
secure
re the cable
cable.
A = -48V
B = 0V
Step 1
If not previously installed, route the customer provided
DC power cable to the bottom of the RRH.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 22 of 24
5-10. Final checks of installation
Step
p1
Inspect site for loose tools, materials, and parts. Remove all such loose tools, materials, and parts.
Step 2
Verify that all the exterior mounting hardware and cable connections are secure.
Step 3
Check the overall appearance of the Alcatel-Lucent RRH2x60-B4.
Note: Verify that nothing is unbalanced, unsecured, or out of alignment and no unintended mechanical
alteration of the Alcatel-Lucent RRH2x60-B4, mounting brackets, or support structure has occurred.
Step
p4
Fill the site install checklist to be delivered to the integration team.
6. Product conformance statements
For the product conformance statements that apply to the Alcatel-Lucent RRH2x60-B4, see Alcatel-Lucent Remote
Radio Head 2x60-B4 – Site Preparation Guidelines, 3MN-01520-0001-RJZZA.
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 23 of 24
7. Reference: General status LED states
General status LED states after power up
LED state
Status
Description
Off
No power supplied
No DC power
Solid red
Initial power on
RRH is initializing (if just powered on or reset)
Non-recoverable critical failure
A critical hardware failure prevents the transmit and/or active receive paths from
functioning
Non-criticall non-recoverable
bl failure
f l
Non-criticall fault
f l (other
h than
h antenna) detected,
d fault
f l is not recoverable,
bl RF
transmission is still ON
Recoverable critical failure
RRH not currently operational due to hardware fault, but should recover (e.g.,
under-temperature warm up, over-temperature critical shutdown)
External power supply failure
A recoverable fault is detected and the external connections (power, antenna)
should be checked
Non-critical recoverable failure
Non-critical fault (other than antenna) detected, fault is recoverable, RF
transmission is still ON
External antenna failure
An equipped antenna has a VSWR fault
Flashing yellow
Software download
RRH is downloading software and RF transmission is OFF, but is currently operational
Solid yellow
Slave CPRI link failure
The slave CPRI link (CPRI-1) has failed
Solid green
Normal operation
No critical failures or faults, transmitter is enabled.
Flashing green
Standby
No critical failures or faults, but the transmitter is disabled
Flashing red
Bottom view
Status LED
Alcatel-Lucent RRH 2x60-B4
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
3MN-01520-0002-RJZZA
Issue 0.02
March 2014
Sheet 24 of 24

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : KH Shin, Andy Ku
Create Date                     : 2014:03:10 10:25:17-07:00
Modify Date                     : 2014:03:10 10:52:16-07:00
Subject                         : RRH300
Language                        : en-US
Tagged PDF                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : Microsoft® Office Word 2007
Metadata Date                   : 2014:03:10 10:52:16-07:00
Format                          : application/pdf
Description                     : RRH300
Creator                         : KH Shin, Andy Ku
Title                           : Test Procedure
Producer                        : Microsoft® Office Word 2007