KP Electronic Systems KPMTU150W UHF DATA TRANSMITTER User Manual users manual

KP Electronic Systems Ltd UHF DATA TRANSMITTER users manual

users manual

Download: KP Electronic Systems KPMTU150W UHF DATA TRANSMITTER User Manual users manual
Mirror Download [FCC.gov]KP Electronic Systems KPMTU150W UHF DATA TRANSMITTER User Manual users manual
Document ID536056
Application IDLKo5uIWedmGnSdcpiGQ0gw==
Document Descriptionusers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.21kB (190122 bits)
Date Submitted2005-04-26 00:00:00
Date Available2005-04-21 00:00:00
Creation Date0000-00-00 00:00:00
Producing SoftwareGNU Ghostscript 7.05
Document Lastmod0000-00-00 00:00:00
Document TitleMicrosoft Word - AMR - MTU150W-Installation Manual Book 096 .doc
Document CreatorPScript5.dll Version 5.2
Document Author: vlad

MTU150W™
2. Meter Input: The meter input is a two
wires cable. These wires connect to the
meter output.
Long-Range
Synthesized Radio
Meter Transmitter
Web Site: www.kpsystems.com
ISRAEL Office
Email: info@kpsystems.com
Tefen Industrial Park, Tefen 24959
Tel: 972-4-987-3066 Fax: 972-4-987-3692
J9
Wall Mounting Installation
1. Fasten the mounting bracket on
the wall with four screws (See
figure 2)
2. Slide the MTU150W unit on the
mounting bracket until the 4 clips
are locking the unit
3. Define the parameters with the
field programmer (FTU100) see
the FTU User Guide
4. Insert the terminator to J9 (See
figure 1)
5. Put the cover
Meter
Input Cables
Figure 1: MTU150W™ View
On-Pipe Mounting Installation
1. Fasten the mounting bracket
on the pipe with two screws
and the “Omega” bracket
(See figure 3)
2. Slide the MTU150W unit on
the mounting bracket until
the 4 clips are locking the
unit
3. Define the parameters with
the field programmer
(FTU100) see the FTU User
Guide
4. Insert the terminator to J9
(See figure 1)
5. Put the cover
USA Office:
KP ELECTRONICS INC.
Email: info@kpsystems.com
109 Tudor Drive, North Wales, PA 19454
Tel: (215) 542-7460 Fax: (215) 542-7461
Book
096
Approved: Amir S.
Rev:
New
MTU150W™ General Description
MTU150W™ is a long-range, synthesized
radio-metering transmitter in the VHF 450470 MHz frequency range.
When the MTU150W detects pulse
conditions at one or more of its inputs the
pulse is counted and saved.
When the number of the pulse is equal to the
Trans Scale defined by the GUP10™, it is
then transmitted to the central station
according to the WAT-NETTM protocol
selected for the system in operation.
MTU150W™ has one connector (see Figure
1).
1. J9: The 10-pin programming jack is a
serial port to connect a PC or a FTU (see
Figure 1).
Unit parameters and meters values
are easily programmed using
Gup10™ utility-programming
software. (See the MTU150W™
Programming Guide) or by the FTU.
Preparing for Operation
Before installing the MTU150W™
on site, perform the following
preparations:
1. Setting communication
parameters
2. Self test
Setting Communication
Parameters
Connect GUP10 program to the
MTU150W™ (see the
MTU150W™ programming
guide)
Self-Test
In order to perform a self-test please
see the Field Programmer User
Guide.
Installing the MTU150W
There are two mounting methods:
1.
2.
Wall mounting
On-Pipe mounting
Figure : Wall Mounting
Figure : On-Pipe Mounting
Restrictions:
1.
2.
Wiring:
Do not mount the unit on any kind
of metal surface.
Do not mount any input cable next
to the antenna (see figure).
Meter types:
1.
2.
3.
There are two main types of meters:
Meters that produces a ‘Passive
Pulse’.
Meters that produces an ‘ActivePulse’ (known also as-‘’Pulse
Generator’).
1.
Connect the two polls of the Meter input
cable to the meter using a self-stripping
insulated connector (like 3M-Scotchlock
or equivalent).
2. Polarity: if a ‘Passive Pulse’ type meter
is connected, there is no polarity so the
wires can be connected in any order, if
an ‘Active Pulse’ type meter is
connected, there is a polarity and the
wires have to be connected in the
following order: Red wire to the
POSITIVE (+) poll and the Black wire
to the NEGATIVE (-) poll,
(see figure 4).
Figure 4: Wiring
Technical Specifications:
Operating Voltage
Standby Current
Tx Current
Power Output
Freq. Stability
Operating Temp.
Storage Temp.
Weight
8–15 VDC
30µA max.
0.8A max.
2W
2.5ppm at
operating temp.
range
-22 F 120 F
(-30 C 60 C)
-40 F 158 F
(-40 C 70 C)
0.5 lb.
(230 gr.)
The manufacturer is not
responsible for any Radio
To maintain compliance with FCC’s
or TV interference caused
RF exposure guidelines, this
by unauthorized
equipment should be installed and
modifications to this
operated with minimum distance
equipment.
20 cm. between the radiator and
Such modifications could
your body.
void the user’s authority
Use only the supplied antenna.
to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 2
Producer                        : GNU Ghostscript 7.05
Title                           : Microsoft Word - AMR - MTU150W-Installation Manual Book 096 .doc
Creator                         : PScript5.dll Version 5.2
Create Date                     : 4/26/2005 14:2:10
Author                          : vlad
EXIF Metadata provided by EXIF.tools
FCC ID Filing: H78KPMTU150W

Navigation menu