Kenmore 79075604102 User Manual GAS RANGE Manuals And Guides L0207028
KENMORE Free Standing, Gas Manual L0207028 KENMORE Free Standing, Gas Owner's Manual, KENMORE Free Standing, Gas installation guides
User Manual: Kenmore 79075604102 79075604102 KENMORE GAS RANGE - Manuals and Guides View the owners manual for your KENMORE GAS RANGE #79075604102. Home:Kitchen Appliance Parts:Kenmore Parts:Kenmore GAS RANGE Manual
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS If the information exactly, in this manual a fire or explosion damage, personal FOR YOUR injury FOR FUTURE may result INSTALLER. REFERENCE. is not followed causing property or death. SAFETY: -- Do not store or use gasoline -- and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: or other flammable vapors A • ALL RANGES CANTIP • INJURYTO PERSONS COULD RESULT • Do not try to light any appliance. • Do not touch anyelectrical in your building. switch; do not use any phone • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire v • INSTALL ANTI-TIP DEVICE PACKED WITH RANGE • SEE INSTALLATION INSTRUCTIONS V department. -- Installation and service must be performed by a qualified installer, service agency or the gas supplier. RANGE OVERALL VIEW 253!4" DIMENSIONS 14-- 30-1/8" ---_l_, 47-3/4" _ _ Minimum to Wall on Either Side of Range Above 36" Height. * Note: 3" SIDE Clearance _- Minimum Minimumto if Equipped with 11000 or greater BTU Burners. Maximum_ r_r _ Cabinets on of Range• oooo 36+-] 1/8" J÷l 3"-I Maximum Depth for Cabinets Above Range Top. !;i i ¸¸ • /7 i ¸¸ 445/8" Door Open ,\_29 7/_2 :> 30" ---_ Clearances and Dimensions 1, Location--Checklocationwhere the ranoewillbeinstalled.Check for proper electrical and gas supply, and the stability of the floor. 2. Dimenslonsthatareshownmust be used. Given dimensions provide minimum clearance, Contact surface must be solid and level. 0" Clearance Below Cooking Top and at Rear of Range. Provide Proper Fuel Type Before Proceeding: Your range is preset to operate on natural gas only. This model was shipped convertible from the factory with the necessary parts and conversioninstructionssupplied. rr_r_'-_t1"_'_l DO NOT attemptto convertthisrangeto LP/Propane settings without theproperLP/Propaneconversionkitprovidedwiththerangeorobtainedfromyour dealer. Followall instructionsprovided with this conversion kit. EspaSol - P_ginas 9-16 P/N316259314(0112) 1 Important Notes to the Installer 1. Readall instructions contained in 2. 3. 4. Never leave children alone or unattended in the area where an appliance is in use. As childrengrow, teach themthe proper,safe use ofallappliances. Never leave the oven door open when the range is unattended. these installation instructionsbefore installingrange. Remove all packingmaterial fromthe ovencompartments before connecting the gas and electrical supply to the range. Observe all governing codes and ordinances. Be sure to leave these instructions with the consumer. Stepping, leaning or sitting on the doors or drawers of this range can result in serious injuries and can also cause damage to the range. Important Note to the Consumer 1. Keep these instructions withyour Use & Care Guide for future reference. Do not store items of interest to children in the cabinets above the range. Children couldbe seriously burnedclimbing on the range to reach items. To eliminate the need to reach over the surface burners, cabinet storage space above the burners should be avoided. Adjust surface burner flame size so it does not extend beyond the edge of the cooking utensil. Excessive flame is hazardous. Do not use the oven as a storage space. This creates a potentially hazardous situation. Never use your range for warming or heating the room. Prolonged use of the range without adequate ventilation can be dangerous. Do not store or use gasoline or other flammable vapors and liquids near this or any other appliance. Explosions or fires could result. Reset all controls to the "off" position after using a programmable timing operation. IMPORTANT SAFETY INSTRUCTIONS Installationof this range must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1--1atest edition when installed in the United States. When installedin a manufactured (mobile) home, installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or with local codes. FOR MODELS WITH SELF-CLEAN FEATURE: Remove broiler pan, food and other utensils before self-cleaning the oven. Wipe up excessspillage.Follow the cleaning instructionsin the Use & Care Guide. Unlike the standard gas range, THIS COOKTOP IS NOT REMOVABLE. Do not attempt to remove the cooktop. This range has been design certified by CSA International. As with any appliance using gas and generating heat, there are certain safety precautions you should follow. You will find them in the Use & Care Guide, read it carefully. • • • • Be sureyour range is installed and grounded properly by a qualified installer or service technician. This range must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No .70--latest edition when installed in the United States. See Grounding Instructions on page 5. Before installing the range in an area covered with linoleum or any other synthetic floor covering, make sure the floor covering can withstand heat at least 90°F above room temperature without shrinking, warping or discoloring. Do not install the range over carpeting unless you place an insulating pad or sheet of 1/4-inch thick plywood between the range and carpeting. Make sure the wall coverings around the range can withstand the heat generated by the range. Do not obstruct the flow of combustion air at the oven vent nor around the base or beneath the lower front panel of the range. Avoid touching the vent openings or nearby surfaces as they may become hot while the oven is in operation. This range requires fresh air for proper burner combustion. DO NOT MAKE ANY ATTEMPT TO OPERATETHE ELECTRIC IGNITION OVEN DURING AN ELECTRICAL POWER FAILURE. RESET ALL OVEN CONTROLS TO "OFF" IN THE EVENT OF A POWER FAILURE. The electric ignitor will automatically re-ignite the oven burner when power resumes if the oven thermostat control was left in the "ON" position. When an electrical power failure occurs during use, the surface burners will continue to operate. During a power outage, the surface burners can be lit with a match. Hold a lightedmatch to the burner, then slowly turn the knob to the LITE position. Use extreme caution when lighting burners this way. 2 Before Starting A. Tools You Will Need For leveling legs and Anti-Tip Bracket: • Adjustable wrench or channel lock pliers 5/16" Nutdriver or Flat Head Screw Driver Electric Drill & 1/8" Diameter Drill Bit (5/32" Masonry Drill Bit if installing in concrete) For gas supply connection: • Pipe wrench For burner flame adjustment: Phillips head _ and blade-type screwdrivers For gas conversion (LP/Propane or Natural): Locate the Bracket Using the Template- (Bracket may be located on either the left or right side of the range. Use the information below to locate the bracket if template is not available). Mark the floor or wall where left or right side of the range will be located. If rear of range is against the wall or no further than 1- 1/4" from wall when installed, you may use the wall or floor mount method. If molding is installed and does not allow the bracket to fit flush against the wall, remove molding or mount bracket to the floor. For wall mount, locate the bracket by placing the back edge of the template against the rear wall and the side edge of template on the mark made referencing the side of the range. Place bracket on top of template and mark location of the screw holes in wall. If rear of range is further than 1-1/4" from the wall when installed, attach bracket to the floor. For floor mount, locate the bracket by placing back edge of the template where the rear of the range will be located. Mark the location of the screw holes, shown in template. Open end wrench - 1/2" Additional • Materials You Will Need Gas line shut-off valve Pipe joint sealant that resists action of LP/Propane gas B° • A new flexible metal appliance conduit (1/2" NPT x 3/4" or 1/2" I.D.) must be design certified by CSA International. Because solid pipe restricts moving the range we recommend using a new flexible conduit (4 to 5 foot length) for each new installation and additional reinstallations. • Always use the (2) new flare union adapters (1/2" NPT x 3/4" or 1/2" I.D.) supplied with the new flexible appliance conduit for connection of the range. Normal Installation Drill Pilot Holes and Fasten Bracket - Drill a 1/8" pilot hole where screws are to be located. If bracket is to be mounted to thewall, drillpilotholeat an approximate 20° downwardangle. If bracket isto be mountedto masonry or ceramic floors,drill a 5/32" pilot hole 1-3/4" deep.The screws provided may be used in wood or concrete material. Use a 5/16" nut-driver or flat head screwdriver to secure the bracket in place. FASTEN BRACKET (WALL or FLOOR MOUNTING) ---_l 1<--1-1/4" Max. Levelinc -Wall Mount Steps Wall Plate 1, Anti-Tip Bracket Installation Instructions [ Important Safety Warning To reducethe risk of tippingof the range, the range must be secured to the floor by properlyinstalled anti-tip bracket and screws packed with the range. Failure to install the anti-tip bracketwill allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it. Serious injurymight resultfrom spilled hot liquidsor from the range itself. Floor Mount J FASTEN BRACKET p Bracket {FLOOR MOUNTING ONLY} Levelinc If range is ever moved to a different location, the anti-tip brackets must also be moved and installed with the range. Instructions are provided for installation in wood or cement fastened to either the floor or wall. When installed to the wall, make sure that screws completely penetrate dry wall and are secu red in wood or metal. When fastening to the floor or wall, be sure that screws do not penetrate electrical wiring or plumbing. Floor Mount 3 p Bracket C. Level and Position Range- Level range by adjusting the (4) leveling legswith a wrench. Note:A minimum clearance of 1/8" is required between the bottom of the range and the leveling leg to allow room for the bracket. Use aspirit level to checkyour adjustments. Slide range back into position. Visually check that rear leveling leg is inserted into and fully secured by the Anti-Tip Bracket by removing lower panel or storage drawer. For modelswith awarmer drawer or broiler compartment, grasp the top rear edge of the range and carefully attempt to tilt it forward. Ige / Recommended Area for 120V Outlet on Rear of , ---_L_ I_',, 23. I _ i_I _ _ Wall and Area for Thru :'._1 I the Wall Connectionof Pipe Stub and Shut Off Valve is Shaded Area. I .. _41 the Floor Connection of Wall Edge Pipe Stub and Shut Off Valve. 3, Seal the openings. Seal anyopeningsinthe wall behindthe rangeand in thefloor under the range after gas supply line is installed. 2. Provide an adequate 4. Connect the range to the gas supply. To prevent leaks, put a pipejointsealant on all male (outside) pipe threads. gas supply, This unit is pre-set to operate on 4" natural gas manifold pressure. A convertible pressure regulator is connected to the manifold and MUST be connected in series with the gas supply line. If the LP/Propane conversion kit has been used, follow instructions provided with the kit for converting the pressure regulator to LP/Propane use. The LP kit can be found on the back side of the range. Your regulator is in the locationshown below. _lr_P"J_l'J"_t_l_ Do not allow regulator to turn on pipe when tightening fittings, Care must be taken during installation of range not to obstruct the flow of combustion and ventilation air. For proper operation, the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure. The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure. Examples: If regulator is set for natural gas 4 inchmanifold pressure, inlet pressure must be at least 5 inches; if regulator has been converted for LP/Propane gas 10 inch manifold pressure, inlet pressure must be at least 11 inches. Gas Regulator Leak testing of the appliance shall be conducted according to the instructions in step 4g. Service The gas supply line should be 1/2" or 3/4" I.D. (shown in the "ON" position,) 4 Manual Flare Shu_vOef f Union Flexible Flare Union AcPoPnl i_lun ce t Adaptor 5. Read electrical connection details and connect electricity to range. Pressure below Regulator Before servicing, disconnect electrical supply at circuit breaker, fuse or power cord. : Off ServiceShut-Off ValveElectric Ignition m_inly _ (Shown in ON Position). Be surelever is in the "On"position when installation is complete a) Install an external manual gas shut-off valve to gas supply line in an easily-accessible location outside of the range. Be sure you know how and where to shut-off the gas supply to the range. b) Install 1/2" flare union adapter to pressure regulator. c) Attach appliance conduit to flare union on regulator. d) Install flare union adapter to external manual shut-off valve. e) Attach appliance conduit to flare union on shut-off valve. f) Make sure service shut-offvalve on pressure regulator is in the "ON" position. g) Check for leaks. Turn the gas supplyon tothe range and use a liquid leak detector at all joints and conduits to check for leaks in the system. Do not use a flame to check for gas leaks. Checking Manifold Gas Pressure Disconnect the range and its individualshut-off valve from the gas supply pipingsystem during any pressuretesting of that system at test pressures greater than 14" of water column pressure (approximately 1/2" psig). The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or lessthan 14"of water column pressure (approximately 1/2" psig). If it should be necessary to check the manifold gas pressu re, connect manometer (water gauge) or other pressure device to the top burner right rear orifice. Using a rubber hose with inside diameter of approximately 1/4," hold tubing down tight over orifice. Turn burner valve on. For an accurate pressure check have at least two (2) other top burners burning. Be sure the gas supply (inlet) pressure is at least one inch above specified range manifold pressure. The gas supply pressure should never be over 14" water column. When properly adjusted for Natural Gas the manifold pressure is 4." (For LP/Propane Gas the manifold pressure is 10.") Electric Reauirements: An individual, properly grounded and polarized branch circuit protected by a 15 amp. circuit breaker or time delay fuse. See serial plate for proper voltage. ExtensionCord Precautions: Because ofpotential safety hazards under certain conditions, we strongly recommend against the use of any extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL listed 3-wire grounding type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to or greater than the branch circuit rating. Such extension cords are obtainable through your local service organization. PLEASE READ CAREFULLY! For personal safety, this product must be properly grounded. Grounding Instructions The power cord of this appliance is equipped with a 3-prong (grounding)plug which mates with a standard 3-pronggroundingwall receptacleto minimizethe possibility of electricshock hazard from this appliance. The customer should have the wall receptacle and circuit checked by a qualified electricianto make sure the receptacle is properly groundedand polarized. Preferred Method _ J J._1- F_=I Grounding ] Type I Wall Receptacle I/ _ [" • '/ /fDo Not, Under I _1 Any Circumstances,I J_Cut, Remove, I lilt] or Bypassthe 1 Gr°undingPr j) _l[ _ I1[ _ Cord with 3-Prong Grounding Plug Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle. DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD. 7. Electric Ignition Surface Burners Operation of electric ignitersshouldbe checked after range and supply line connectorshave been carefullychecked for leaks and range has been connected to electric power. Operation of Surface Burners 6, Installation of Surface Burner Caps Your range is equipped with any combinationof the sealed burners. Refer to the illustration below to find your surface burner and surface burnercap configuration. Be sureto place the correct burner cap at on all four surface burners. a. b, _9.5k To check for proper lighting, push in and turn a surface burner knob counterclockwise to the LITE position. You will hear the igniter sparking (see illustration below). The surface burner should light when gas is available to thetopburner. Purge air from supply lines byleaving knob in the LITE position until burner ignites. Each burner should light within four (4) seconds in normal operation after air has been purged from supply lines. c. Visually check that burner has lit. Once the burner lights, the control knob should be turned out of the LITE position. d. There are separate electrodes (igniters) for each burner. Try each knob separately until all bumervalves have been checked. Note: Knob styles and colors may vary from that pictured. Possible Surface Burner and Cap configurations Install the parts illustrated below at all four surface burner locations: 1st - Install the surface burner pans (if equipped); 2nd -install the surface burner heads; 3rd - install the surface burner caps and 4th;install the burner grates. e Surface Burner \ Surface Cap _ Surface Burner Head Removable Burner Drip Pan (on some models) 6 appear at the oven burner. There isa time lapse from 30 to 60 seconds after the thermostat is turned ON before the flame appears at the oven burner. When the oven reaches the dial setting, the glowing igniter will go off. The burner flame will go "out" in 20 to 30 seconds after the igniter goes "OFF." To maintain any given oven temperatu re, this cycle will continue as long as the dial (or display) is set to operate. 8. Adjust the "LOW" Setting of Surface Burner Valve (Linear Flow Valves Only): To Sudace Burner After removing all packing materials and literature from the oven: a) Set oven to BAKE at 300_F. See Use & Care Guide for operating instructions• b) Within 60 seconds the oven burner should ignite. Check for proper flame, and allow the burner to cycle once. Reset controls to off. c) If your model is equipped with a waist-high broiler, set oven to BROIL. See Use & Care Guide for operating instructions. d) Within 60 seconds the broil burner should ignite. Check for proper flame. Reset controls to off. Test to verify if "LOW" setting should be adjusted a. Push in and turn control to LITE until burner ignites. b. Push in and quickly turn knob to LOWEST POSITION. e. If burner goes out, reset control to OFF. d. Remove the surface burner control knob. e. Insert a thin-bladed screwdriver into the hollow valve stem and engage the slotted screw inside. Flame size can be increased or decreased with the turn of the screw. Turn counterclockwise to increase flame size. Turn clockwise to decrease flame size. 10. Air Shutter-Oven Burner Burner Flame Size Waist-High Burner (SelfClean Models) Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing the flame. Flame should be as small as possible without going out. Lower Oven Bottorr (Removable) Air Shutter Note: Air mixture adjustment is not required on surface burners. Operation 7 The approximate flame length of the oven burner is 1 inch (distinct inner, blue flame). of Oven Burners and Oven Adjustments To determine ifthe oven burner flame is proper, remove the oven bottom and burner baffle and set the oven to bake at 300°F. 9, Electric Ignition Burners Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power. To remove the oven bottom, remove oven hold down screws at rear of oven bottom. Pull up at rear, disengage front of oven bottom from oven front frame, and pull the oven bottom out of the oven. Remove burner baffle so that the burner flame can be observed. If the flame is yellow in color, increase air shutter opening size. (See "2" in illustration below.) If the flame is a distinct blue, reduce the air shutter opening size. The oven burner is equipped with an electric control system as well as an electric oven burner igniter. If your model is equipped with a waist-high broil burner, it will also have an electric burner igniter. These control systems require no adjustment• When the oven is set to operate, current will flow to the igniter. It will "glow" similar to a light bulb. When the igniter has reached a temperature sufficient to ignite gas, the electrically controlled oven valve will open and flame will To adjust loosen lock screw (see "3" illustration below), reposition air shutter, and tighten lock screw. Replace oven bottom. 7 Care, Cleaning and Maintenance Oven Refer to the Use & Care Guide for cleaning instructions. Burner Tube ® (_rShu_er If removing the range is necessary for cleaning or maintenance, shut off gas supply. Disconnect the gas and electrical supply. If the gas or electrical supply is inaccessible, lift the unit slightly at the front and pull out away from the wall. Pull only as far as necessary to disconnect the gas and electrical supply. Finish removing the unit for servicing and cleaning. Reinstall in reverse order making sure to level the range and check gas connections for leaks. See page 3, step 1 for proper anchoring instructions. ® Orifice Hood 11. Air Shutter-Broil Burner The approximate flame length of the broil burner is 1 inch (distinctinner, blue flame). To determine to broil. ifthe broil bumerflame is proper, setthe Before You Call for Service Read the "Before You Call" and operating instructionsections in your Use & Care Guide. It may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this appliance. oven If the flame is yellow in color, increase air shutter opening size. (See "2" in illustration above.) If the flame is a distinct blue, reduce the air shutter opening size. Refer to the warranty in your Use & Care Guide for our tollfree service number and address. Please call or write if you have inquiries about you r range product and/or need to order parts. To adjust, loosen lock screw (see "3" in illustrationabove), reposition air shutter, and tighten lock screw. 12.Make Sure Range is Level. Level the range by placing a level horizontallyon an oven rack. Check diagonally from front to back, then level the range byeitheradjustingthe levelinglegs or byplacingshims under the corners of the range as needed. 7 r 13. After installation is complete, make sure all controls are left in the OFF position. I • _ r l ,,;% Model and Serial Number Location Forsea/edburnerovens, the identificationplate islocatedon the right-hand surface of the oven front frame at the storage or warmer drawer; or the lower panel area. When orderingparts for or making inquires about your range, always be sure to include the model and serial numbers and a lot number or letter from the identificationplate on your range. Your identification plate also tells you the rating of the burners, the type of fuel and the pressure the range was adjusted for when it left the factory. Serial plate location: Open storage or warmer drawer, located on right side of range frame. 8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 8 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 12:08:41 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools