INSTRUCTION MANUAL
VHF FM TRANSCEIVER
TK-290
TK-390
UHF FM TRANSCEIVER
KENWOOD CORPORATION
© B62-0816-30 (K)(MC)
09 08 07 06 05 04 03
THANK YOU!
We are grateful you chose KENWOOD
for your land mobile radio applications.
We believe this easy-to-use transceiver
will provide dependable
communications to keep personnel
operating at peak efficiency.
KENWOOD transceivers incorporate
the latest in advanced technology. As a
result, we feel strongly that you will be
pleased with the quality and features of
this product.
NOTICES TO THE USER
WARNING:
◆
◆
◆
◆
◆
MODELS COVERED BY THIS
MANUAL
TK-290: VHF FM Transceiver
TK-390: UHF FM Transceiver
GOVERNMENT LAW PROHIBITS THE
OPERATION OF UNLICENSED RADIO
TRANSMITTERS WITHIN THE
TERRITORIES UNDER GOVERNMENT
CONTROL.
ILLEGAL OPERATION IS PUNISHABLE
BY FINE OR IMPRISONMENT OR BOTH.
REFER SERVICE TO QUALIFIED
TECHNICIANS ONLY.
DO NOT OPERATE YOUR
TRANSCEIVER IN EXPLOSIVE
ATMOSPHERES (GASES, DUST,
FUMES, ETC.).
TURN OFF YOUR TRANSCEIVER
WHILE TAKING ON FUEL, OR WHILE
PARKED IN GASOLINE SERVICE
STATIONS.
SAFETY: It is important that the
operator is aware of, and understands,
hazards common to the operation of
any transceiver.
ATTENTION (U.S.A. Only):
The RBRC Recycle seal found on KENWOOD nickelcadmium (Ni-Cd) battery packs indicates KENWOOD’s
voluntary participation in an industry program to collect
and recycle Ni-Cd batteries after their operating life
has expired. The RBRC program is an alternative to
disposing Ni-Cd batteries with your regular refuse or
in municipal waste streams, which is illegal in some
areas.
For information on Ni-Cd battery
recycling in your area, call (toll free)
1-800-8-BATTERY (1-800-822-8837).
KENWOOD ’s involvement in this
program is part of our commitment to
preserve our environment and
conserve our natural resources.
One or more of the following
statements may be applicable:
FCC WARNING
This equipment generates or uses radio
frequency energy. Changes or modifications to
this equipment may cause harmful interference
unless the modifications are expressly approved
in the instruction manual. The user could lose
the authority to operate this equipment if an
unauthorized change or modification is made.
ii
INFORMATION TO THE DIGITAL DEVICE
USER REQUIRED BY THE FCC
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation.
This equipment generates, uses and can
generate radio frequency energy and, if not
installed and used in accordance with the
instructions, may cause harmful interference to
radio communications. However, there is no
guarantee that the interference will not occur in a
particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning
the equipment off and on, the user is
encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the
equipment and receiver.
• Connect the equipment to an outlet on a
circuit different from that to which the
receiver is connected.
• Consult the dealer for technical assistance.
CONTENTS
UNPACKING AND CHECKING
EQUIPMENT ................................ 1
Supplied Accessories ................ 1
INSTALLING THE NiCd BATTERY PACK
(OPTIONAL) ................................ 2
INSTALLING THE ANTENNA (OPTIONAL) ... 3
INSTALLING THE CAP OVER THE
UNIVERSAL CONNECTOR ................ 3
INSTALLING THE BELT HOOK ............ 3
INSTALLING THE SPEAKER/
MICROPHONE (OPTIONAL) .............. 4
GETTING ACQUAINTED ................... 5
Key Descriptions ...................... 6
Display .................................. 7
PROGRAMMABLE FUNCTIONS .......... 8
BASIC OPERATIONS ...................... 10
Switching Power ON/OFF ........... 10
Adjusting the Volume................ 10
Selecting a Group ................... 10
Selecting a Channel ................. 11
Adjusting the Squelch ............... 11
Making a Call ......................... 11
KEY LOCK .................................. 12
TIME-OUT TIMER (TOT) ................. 12
SCANNING ................................. 12
Priority Scan .......................... 13
DTMF CALLING ........................... 13
Manual Dialing ....................... 13
Redialing .............................. 14
Auto Dialing ........................... 14
DEALER PROGRAMMABLE
OPTIONS ................................... 16
AUDIBLE USER FEEDBACK TONES .... 19
iii
UNPACKING AND CHECKING
EQUIPMENT
Note: The following unpacking instructions are for
use by your KENWOOD dealer, an authorized
KENWOOD service facility, or the factory.
Carefully unpack the transceiver. We
recommend that you identify the items
listed in the following table before
discarding the packing material. If any
items have been damaged during
shipment, file a claim with the carrier
immediately.
■ Supplied Accessories
Item
Part Number
Quantity
Belt hook
J29-0651-XX
Universal
connector cap
B09-0363-XX
Channel seal
B03-0594-XX
Channel stopper
D32-0421-XX
Screw set
N99-2004-XX
—
Warranty card
Instruction manual B62-0816-XX
Universal connector cap
Belt hook
Channel stopper
Accessory
Binding
screw
screws
Channel seal
Screw set
INSTALLING THE NiCd BATTERY
PACK (OPTIONAL)
The battery pack is not charged at the
factory. Charge the pack before use.
Repeat the charge/discharge cycles two
or three times after purchase or
extended storage (greater than
2 months) to bring the battery pack to
its normal operating capacity.
1 Match the four grooves of the battery
pack with the corresponding guides
on the back of the transceiver.
2 Slide the battery pack along the back
of the transceiver until the release
latch on the base of the transceiver
locks.
3 To remove the battery pack, push
down on the release latch and slide
the pack away from the transceiver.
CAUTION:
◆
DO NOT RECHARGE THE BATTERY PACK IF
IT IS ALREADY FULLY CHARGED. DOING
THIS WILL OVERCHARGE THE BATTERY
PACK WHICH MAY SHORTEN ITS LIFE OR
DAMAGE IT.
◆ AFTER RECHARGING THE BATTERY PACK,
DISCONNECT IT FROM THE CHARGER. IF,
HAVING RECHARGED THE BATTERY, THE
POWER TO THE CHARGER IS TURNED OFF
AND THEN BACK ON WHILE THE PACK IS
STILL CONNECTED, RECHARGING WILL
START AGAIN AND THE BATTERY WILL
BECOME OVERCHARGED.
◆ DO NOT SHORT THE BATTERY PACK
TERMINALS OR DISPOSE OF THE BATTERY
BY FIRE. NEVER ATTEMPT TO REMOVE
THE CASE FROM THE BATTERY PACK.
INSTALLING THE ANTENNA (OPTIONAL)
INSTALLING THE BELT HOOK
Screw the antenna into the connector
on the top of the transceiver by holding
the antenna at its base and turning it
clockwise until secure.
If necessary, attach the belt hook using
the two binding screws (3 x 6 mm)
which are supplied in the screw set.
INSTALLING THE CAP OVER THE
UNIVERSAL CONNECTOR
location may get hot during continuous
transmission or when left sitting in a hot
environment.
Note: If the belt hook is not installed, its mounting
When a speaker/microphone is not
being used, install the cap over the
universal connector using the supplied
accessory screw (4 x 6 mm).
The antenna
connector of the
transceiver is an
SMA male type
connector.
Note: To keep the transceiver water resistant, you
must cover the universal connector with the cap or
the speaker/microphone connector.
INSTALLING THE SPEAKER/
MICROPHONE (OPTIONAL)
1 Insert the guide of the speaker/
microphone connector into the
groove on the transceiver universal
connector.
A speaker/microphone with an antenna
connector is also available.
2 Secure the connector in place using
the attached screw.
Note: The speaker/microphone PF keys can be
programmed with the functions listed in the table on
page 8.
GETTING ACQUAINTED
SMA male type
antenna connector
Microphone
Speaker
Display
Battery pack
release latch
■ Key Descriptions
q TX/Busy/Battery low indicator
Lights red while transmitting.
Lights green while receiving.
Flashes red when the battery
power is low while transmitting;
replace or recharge the battery.
Note: This indicator can be disabled by
your dealer {page 16}.
w Power switch/Volume control
Turn clockwise to switch ON the
transceiver. Turn
counterclockwise, until a click
sounds, to switch OFF the
transceiver. Rotate to adjust the
volume level.
e Selector
Rotate this control to activate its
programmable function {page 8}.
r Toggle switch
Switch the toggle position to
activate its programmable
function {page 8}.
t Top 1
Press these PF
(programmable
y Top 2
function) keys to
u Orange
activate their
i Side 1
programmable
functions {page 8}.
o Side 2
!0 PTT (Push-To-Talk) switch
Press this switch, then speak into
the microphone to call a station.
!1 DTMF keypad
(keypad models only)
Press the keys on the telephone
keypad to send DTMF tones.
!2 Universal connector
Connect the external speaker/
microphone (optional) here.
Otherwise, keep the supplied
cover in place.
■ Display
q Alphanumeric display
Displays the operating group or
channel number, or the group or
channel name. When making a
DTMF or 2 Tone call, the display
will alternate between CALL and
the channel. Also displays various
menu functions.
w 7 Segment display
Displays the operating group or
channel number. Also displays
tA (Talk Around), P1 (Priority1),
P2 (Priority2), PP (Priority1 and
Priority2), or HC (Home
Channel); depending on the
function being used.
e A (Add) indicator
Appears when a channel is
added to the scanning sequence.
r SCN (Scan) indicator
Appears when Scan mode is active.
t MON (Monitor) indicator
Appears when the monitor
function is active.
y LO (Low) indicator
Appears when low power is
selected.
u OPT indicator
Appears when Operator
Selectable Tone is enabled.
i AUX (Auxiliary) indicator
Appears when Aux is ON.
Appears and blinks when the
optional scrambler board is
enabled.
Note: The alphanumeric and 7 segment
displays can be inverted if a PF key or the
toggle switch is programmed with Invert
Display {page 8}.
PROGRAMMABLE FUNCTIONS
Function Name
Aux 1
Channel Down
Channel Name
Channel Select
Channel Up
Delete/Add
Emergency Call 2
Group Down
Group Scan
Group Select
Group Up
Home Channel
Invert Display
Key Lock
Lamp
Low Power
Monitor
Monitor Momentary
Selector
Toggle
(e
e)
Switch (r)
PF Keys (t, y,
u, i, o)
Speaker/
Microphone PF Keys
Function Name
No Function
Operator Selectable Tone
Operator Selectable Priority1
Operator Selectable Priority2
Scan
Scrambler 3
Shift
SP Attenuation
Squelch Level
Squelch OFF
Squelch Momentary
Talk Around
Selector
Toggle
(e
e)
Switch (r)
PF Keys (t, y,
u, i, o)
Speaker/
Microphone PF Keys
1 This
function can be selected when the scrambler board has not been installed.
2 This function can be selected when the ANI board has been installed.
3 This function can be selected when the scrambler board has been installed.
Please contact your dealer for details on these functions.
Note:
◆
◆
To program 2 functions onto each PF key and the toggle switch, “Shift” must first be programmed.
Programming the same function onto both a PF key and the toggle switch will cause an error to occur
on the PF key.
BASIC OPERATIONS
■ Switching Power ON/OFF
To switch ON the transceiver, turn
the Power switch/Volume control
clockwise until it clicks.
To switch OFF the transceiver, turn
the Power switch/Volume control
counterclockwise until it clicks.
If the Radio Password function is
programmed {page 16}, LOCKED
will appear on the display when the
power is turned ON. To unlock the
transceiver, enter the password, then
press the # key. If the wrong
password is entered, an error tone
will sound, and the transceiver will
remain locked. The password can
be a maximum of 6 digits. (This
function is available on keypad
models only.)
10
■ Adjusting the Volume
Turn the Power switch/Volume
control to adjust the volume.
Clockwise increases the volume,
and counterclockwise decreases it.
■ Selecting a Group
Turn the Selector, press the Group
Up and Group Down keys, or use
the toggle switch to select a group.
• Use the Selector, PF keys, or toggle
switch, depending on which one is
programmed with the group functions.
■ Selecting a Channel
Turn the Selector or press the
Channel Up and Channel Down
keys to select a channel.
• Use the Selector or PF keys,
depending on which one is
programmed with the channel
functions.
■ Adjusting the Squelch
1 Press the key programmed as
Squelch Level.
2 Press the keys programmed as
Group Up and Group Down or
Channel Up and Channel Down
to adjust the squelch level.
■ Making a Call
1 Select the desired group and
channel {page 10}.
2 Use the key or switch
programmed as Monitor to check
whether or not the channel is
free.
• If the channel is busy, wait until it
becomes free.
3 Press and hold the PTT switch,
then speak into the microphone
in your normal voice.
• For best results, hold the
transceiver approximately 3 to
4 cm (1 1/2 inches) from your lips.
4 Release the PTT switch to
receive.
11
KEY LOCK
SCANNING
Use the key or switch programmed as
Key Lock to activate the Key Lock
function. When activated, only the PTT
and toggle switch, the Selector, and
the keys programmed as Emergency
Call, Monitor, Monitor Momentary,
SP Attenuation, Squelch OFF,
Squelch Momentary, and Lamp can
be used.
Note: The Scan function can be used with a
minimum of two channels.
TIME-OUT TIMER (TOT)
The TOT is used to automatically inhibit
transmission after a specified time
elapses. If the PTT switch is held down
for longer than the programmed time,
the transceiver will stop transmitting and
a warning tone will sound. To stop the
warning tone, release the PTT switch.
Note: TOT settings can be programmed by your
dealer {page 16}.
12
Scan is used to monitor signals on the
transceiver channels. When scanning,
the transceiver checks each channel for
a signal, and stops on a channel if one
is present.
Use the key or switch programmed as
Scan.
• “SCAN” or the revert group/channel
number (depending on which one is
programmed by your dealer), and the
SCN icon will appear on the display.
• A confirmation tone will sound.
To quit scanning, use the Scan key or
switch again.
• Two confirmation tones will sound.
■ Priority Scan
For Priority Scan to function, the
Priority1 or Priority2 channel must
be programmed.
• If only one of the priority channels are
programmed, the transceiver will
automatically change to that priority
channel when a signal is received on
it. This change occurs even if a
signal is being received on another
channel.
• If both priority channels are
programmed, Priority1 is the high
priority and Priority2 is the low
priority. If a signal is being received
on the Priority1 channel, the
transceiver will change to that
channel, even if a signal is being
received on the Priority2 channel.
DTMF CALLING
Note: This function can only be used by
transceivers with DTMF keypads.
■ Manual Dialing
To dial a number manually:
1 Press and hold the PTT switch.
• If Keypad Auto PTT is enabled
{page 16}, you do not need to
press the PTT switch.
2 Press the desired DTMF keys.
13
■ Redialing
■ Auto Dialing
A maximum of 16 digits can be
redialed. The last number dialed,
either manually or automatically, will
be redialed.
To redial a number:
1 Press the
key.
• An “A” will appear on the display.
2 Press the 0 key.
• The transceiver will redial the last
number, and the digits will appear
on the display.
Note: If the transceiver power is switched OFF,
the redial memory will be erased.
Note: Auto dialing is either enabled or disabled
by your dealer {page 16}.
Store:
To store a number in memory:
1 Press the # key.
• A “D” will appear on the display.
2 Press the desired DTMF keys to
enter a maximum of 16 digits.
• Press and hold the PTT switch,
, or # to
then press 2, 5, 8, 0,
enter A, B, C, D, , or #
(consecutively).
3 Press the # key.
4 Select the desired memory
channel by pressing a DTMF key
(1 ~ 9).
• The entered number will be stored
in the memory channel selected.
14
Confirm:
To confirm a stored number:
1 Press the # key.
• A “D” will appear on the display.
2 Press the
key.
• “D-” will appear on the display.
3 Press the memory channel key
(1 ~ 9) with the stored number
you want to confirm.
• The stored digits will appear on
the display, and the DTMF tones
will sound.
• The transceiver will begin the
transmission, and the digits will
appear on the display.
Clear:
To erase a stored number from
memory:
1 Press the # key.
• A “D” will appear on the display.
2 Press the # key again.
• “D-CLR” will appear on the
display.
Send:
To send a stored number:
1 Press the
2 Press the memory channel key
(1 ~ 9) with the stored number
you want to send.
key.
• An “A” will appear on the display.
3 Press the memory channel key
(1 ~ 9) with the stored number
you want to erase.
15
DEALER PROGRAMMABLE OPTIONS
The following list of functions can be enabled or disabled by your dealer:
CHANNEL
Group Name
Receive Frequency
Transmit Frequency
QT/DQT Decode
QT/DQT Encode
Channel Name
Option Signaling
TX Power
Wide/Narrow
Scan Delete/Add
PTT ID
Busy Channel Lockout (BCL)
Beat Shift
Voice Scrambler
16
Priority1 Channel
Priority2 Channel
Home Channel
Emergency Channel
EDIT
Scan Information
Priority1
Priority2
Look Back Time A
Look Back Time B
Revert Channel
Dropout Delay Time
Dwell Time
Group Scan
Priority Channel Quick Scan
Battery Warning
Priority1 Temp. D/A
Priority2 Temp. D/A
Temp. D/A Key Hold Time
Revert Channel Display
Optional Features
Channel Text Size
Group Text Size
Power ON Tone
Control Tone
Warning Tone
Alert Tone
Minimum Volume
Squelch Level
BCL Override
Selective Call Alert LED
Radio Password
Busy LED
TX LED
7 Segment LCD Display
Invert Display
Emergency Channel Display
Clear to Transpond
External Speaker
Noise Cancel Mic
Mode: Self Programming/Panel Test/
Clone/Main Programming
ID: ID Format/Speed/PTT ID/Dial ID/
Connect ID/Disconnect ID
Operator Selectable Tone: OST Back Up/
Direct OST/OST Name
Group Features
Time-out Timer (TOT)
Data Password
TOT Pre-Alert
17
TOT Rekey Time
and # Tone (Encode)
TOT Reset Time
DTMF Side Tone (Encode)
Group Delete/Add
DTMF Hold Time (Encode)
Battery Save
Keypad Auto PTT (Encode)
Signaling
Manual Dial (Encode)
2-Tone (1, 2, and 3)
Auto Dial (Encode)
Decoder Call Format (1 and 2)
Auto Dial Programming (Encode)
Decoder Call Type (1 and 2)
Auto Dial Memory (Encode)
Tones (A, B, and C)
Alert Tone/Transpond (Decode)
Alert Tone/Transpond
Primary Code (Decode)
Auto Reset
Secondary Code (Decode)
DTMF
Auto Reset (Decode)
DTMF Speed (Encode)
Dead Beat Disable (Decode)
First Digit Time (Encode)
Embedded Message
First Digit Delay (Encode)
(64 characters maximum)
Please contact your dealer for details on these functions.
18
AUDIBLE USER FEEDBACK TONES
The transceiver outputs various tones to
indicate the transceiver operating
status.
•
•
•
•
•
•
•
•
•
•
•
Power ON Tone
Key Operation Tone
End of Operation Tone
Operation Error Tone
Sequence Error Tone
Transmission Inhibit Tone
Time-out Timer Warning Tone
Selective Call Alert Tone
Call Alert (Transpond)
Dead Beat Disable Tone
Password Agreement Tone
Please contact your dealer for details
on these functions.
19
Terminal Descriptions
Universal connector
NO.
Name
Description
1 SSW
EXT/INT SP switch input
2 SP+
BTL output + for external speaker
3 SPBTL output - for external speaker
4 MSW
EXT/INT MIC switch input
5 EMC
External microphone input
6 ME
External microphone earth
7 PTT
PTT input
8 PF
Programmable function key input
9 NC
Non connect
10 EMC
Earth
11 5M
5V output
12 TXD
Serial data output
13 RXD
Serial data input
14 NX
Non connect
External RF output
EXT OUT
15
This terminal has a built in EXIT/INT
Non connect: INT ANT connect:EXT
Antenna Terminal
50 Ω impedance
Battery Terminal
The battery terminal uses a spring plate.
The negative terminal connects to the chassis ground.
The battery is mounted on the rear and upper side of the transceiver using a
sliding mounting method.
Back side view
Radio Frequency Energy Safety Information
This KENWOOD transceiver has been tested and complies with the standards listed below, in regards
to Radio Frequency (RF) energy and electromagnetic energy (EME) generated by the transceiver.
• FCC RF exposure limits for Occupational Use Only . RF Exposure limits adopted by the FCC are generally
•
•
•
based on recommendations from the National Council on Radiation Protection and Measurements, & the
American National Standards Institute.
FCC OET Bulletin 65 Edition 97-01 Supplement C
American National Standards Institute (C95.1 – 1992)
American National Standards Institute (C95.3 – 1992)
This KENWOOD transceiver generates RF EME while transmitting. RF EME (Radio Frequency Electric &
Magnetic Energy) has the potential to cause slight thermal, or heating effects to any part of your body less
than the recommended distance from this radio transmitter’s antenna. RF energy exposure is determined
primarily by the distance to and the power of the transmitting device. In general, RF exposure is minimized
when the lowest possible power is used or transmission time is kept to the minimum required for consistent
communications, and the greatest distance possible from the antenna to the body is maintained. The
transceiver has been designed for and is classified for Occupational Use Only . Occupational/ controlled
exposure limits are applicable to situations in which persons are exposed to RF energy as a consequence
of their employment, and such persons have been made aware of the potential for exposure and can
exercise control over their exposure. This means you can use the transceiver only if you are aware of
the potential hazards of operating a transceiver and are familiar in ways to minimize these hazards. This
transceiver is not intended for use by the general public in uncontrolled environments. Uncontrolled
environment exposure limits are applicable to situations in which the general public may be exposed to RF
energy, or in which the persons who are exposed as a consequence of their employment may not be fully
aware of the potential for exposure or cannot exercise control over their exposure.
The following list provides you with the information required to ensure that you are aware of RF
exposure and of how to operate this transceiver so that the FCC RF exposure limitations are not
exceeded.
•
•
•
While transmitting (holding the PTT switch or speaking with VOX enabled), always keep the antenna
and the radio at least 3 cm (1 3/16 inches) from your body or face, as well as from any bystanders. A
LED on the top of the radio shows red when the transmitter is operating in both PTT and VOX modes.
Do not transmit for more than 50% of the total transceiver use time; transmitting over 50% of the total use
time may exceed the limits in accordance to the FCC RF exposure requirements. Nominal transceiver
operation is 5% transmission time, 5% reception time, and 90% stand-by time.
Use only the specified antenna for this transceiver; this may be either the antenna provided with the
transceiver or another antenna authorized by KENWOOD.
Use only KENWOOD authorized accessories (antennas, battery packs, belt clips, Speaker/ Mics
or headsets etc.): When worn on the body, always place the radio in a KENWOOD recommended
clip or carrying case meant for this product. The use of other than recommended or approved
body- worn accessories may result in RF exposure levels which exceed the FCC’s occupational/
controlled environment RF exposure limits.
To ensure that your exposure to RF EME is within the FCC limits for occupational use, you must
observe and adhere to the above points.
Electromagnetic Interference Compatibility
Electronic devices are susceptible to electromagnetic interference (EMI) if they are not adequately
shielded or designed for electromagnetic compatibility. Because this transceiver generates RF
energy, it can cause interference to such equipment.
•
•
Turn OFF your transceiver where signs are posted to do so. Hospitals and health care facilities use
equipment that is sensitive to electromagnetic radiation.
Turn OFF your transceiver while on board an aircraft when so instructed. Use of the transceiver must
be in accordance with airline regulations and/or crew instructions.
B59-2448-00

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Create Date                     : 2006:06:08 02:13:16Z
Modify Date                     : 2009:05:25 11:36:02+09:00
Metadata Date                   : 2009:05:25 11:36:02+09:00
Creator Tool                    : PageMaker 6.5
Format                          : application/pdf
Creator                         : .
Title                           : 
Document ID                     : uuid:bb748b62-fb88-4f4d-adf3-af681d3ec859
Instance ID                     : uuid:bd759c99-ac52-45a8-a5cd-5a9ca05feeeb
Page Count                      : 25
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ALH219000

Navigation menu