Keyence 0945A Wireless Barcode scanner User Manual HR 51 Series E

Keyence Corporation Wireless Barcode scanner HR 51 Series E

Manual

WirelessHand-held Barcode ReaderHR-51 SeriesUser’s ManualRead this manual before use in order to achieve maximumperformance.Keep this manual in a safe place after reading so that youcan use it at any time.
IntroductionThis manual contains information about procedures for handling, operations, warnings, and pre-cautions about “Hand-held Barcode Reader HR-51 Series”.Make sure to read this manual before use. Keep this manual in a safe place for future reference.■SymbolsThis manual uses the following symbols that alert you to important messages.Be sure to read these messages carefully. Indicates reference pages in this manual or other manuals.■General Precautions•At startup and during operation, be sure to monitor the functions and performance ofHR-51 and confirm the normal operation.•We recommend that you take substantial safety measures to avoid any damage in theevent the HR-51 series malfunctions.•If the product is modified or used in any way other than described in the specifications,its functions and performance cannot be guaranteed.•When the HR-51 series is used in combination with other devices, the functions and per-formance may be degraded, depending on the operating conditions, surrounding envi-ronment, etc..•Do not use the HR-51 series for the purpose of protecting the human body.■NoticeWhen this product is used under the circumstances and operating environmentsdescribed below, adhere to the limitations of the ratings, take adequate measures toensure safety such as fail-safe installations and consult a KEYENCE sales representative.•For use under circumstances or environments which are not described in the manual.•For use with nuclear power control, railway, aircraft, vehicles, incinerators, medicalequipment, entertainment equipment, safety devices, etc.•For use in applications where death or serious property damage is possible and exten-sive safety precautions are required.DANGER Failure to follow instructions and mishandling the product may lead to death orserious injury.WARNINGFailure to follow instructions may lead to physical injury (i.e., electric shock,burns, etc.).CAUTION Failure to follow instructions may lead to the product malfunctions.NoteProvides additional information on proper operations that can be easily mistaken.
1Safety Precautions■Safety Precautions on Laser ApparatusThe “Hand-held Barcode Reader HR-51 Series” employs a visible red semiconductor laserfor its light source. HR-51 has a wavelength of 650 nm and is classified as a Class 2 laserunder IEC standard (IEC60825-1: “Safety of Laser Products”).■Warning label locationsWARNINGUse of controls or adjustments or performunce of procedures other than thosespecified herein may result in hazardous radiation exposure.Model HR-51Wavelength 650nmMaximum output 1.0mWClass CLASS 2 (IEC60825-1)WARNING•Do not directly stare into the laser beams or specularly reflected light. Doingso may result in serious eye injury. Do not direct laser beams towards a humanbody intentionally although laser beams will not cause damage even if itstrikes exposed skin.•Never disassemble HR-51. HR-51 is not equipped with a mechanism to stoplaser emission when disassembled. If HR-51 is disassembled, laser beamsemitted from HR-51 may cause eye injury.•Before cleaning the transmitter/receiver part of laser scanner, be sure to stopthe emission of laser beams. Otherwise, exposure to the laser may cause eyeinjury.•Be careful of the light path of laser beams.Be especially careful of the specularly reflected light.Do not install HR-51 in such a way that the laser beam passes at eye heightwhen operating HR-51.HR-51
2Operating PrecautionsCAUTION■Precautions on use•Do not disassemble or modify this unit. Doing so may lead to product fail-ure.•This unit is a precision instrument. Dropping the unit or subjecting it toshock may cause damage. Take enough care when carrying or using thisunit.•Locate cables as far as possible from high-voltage lines and power lines.Otherwise, generated noise may cause product failure or operation error.•Do not hold the unit by its cable when carrying. The HR-51 may strike thewall and may be damaged. Also due to the stress on the cables, the wiresmay be broken.•Be sure to use the supplied AC adaptor or optional AC adaptor for HR-UC51. Using other AC adaptors than these may result in fire, electric shockor product failures. •Be sure to periodically clean the power connection part of AC adaptor con-nected to HR-UC51 as it tends to catch dust. Tracking phenomenon mayresult in fire. Also, disconnect the AC adaptor from the outlet if not using along period of time.•When recharging HR-51 on HR-UC51, be sure to check no foreign objectsare attached to the recharge terminal. Foreign objects may cause fire.■Environments for useDo not use in the following locations. Product failure or mechanical error mayoccur.•Locations where the ambient temperature is beyond specified range•Locations where the ambient humidity is beyond specified range•Locations where the unit is exposed to direct sunlight •High-temperature locations such as inside a closed car•Locations where condensation occurs due to the rapid humidity change•Locations where there are corrosive gas or combustible gas•Locations where there is a large amount of airborne dust, salt, iron, andgreasy fumes•Locations where the unit may be directly subjected to vibration or impact•Locations where water, oil or chemicals may splash onto the unit•Locations where a strong magnetic or electric field is generated
3Precautions for using the built-in rechargeable batteryHR-51 contains the built-in lithium ion rechargeable battery. Observe the following precau-tions for proper use.On disposal, follow the disposal procedure specified by each local government.DANGER•Stop the recharging process if recharging does not finish even after the speci-fied recharge time.The built-in rechargeable battery may become hot, explode or cause fire.•If there is leak or abnormal smell from the built-in rechargeable battery, keep itaway from fire immediately.The battery electrolyte may catch fire, resulting in explosion and ignition.•Never put it into the fire. The explosion of built-in rechargeable battery maylead to a serious accident.•Never put it into the water. The chemical reaction of the built-in rechargeablebattery may lead to an accident.WARNING•In the event that the leaked liquid comes into the eye, do not wipe it. Clean itimmediately with clean water instead and go to the eye specialist. If the eye isleft untreated, eye damage may result.•In the event the liquid leaked from the built-in rechargeable battery is attachedto the skin, wash it immediately with clean water. Otherwise, skin irritation mayoccur.CAUTION•Do not leave or use it in a heated car, under the scorching sun or at high-humidity locations. The built-in rechargeable battery may become hot or causefire. Also, the battery life may become short and the performance may deterio-rate.•Recharge and use the built-in battery in the temperature environment of –5 to140 degree. If it is used in other temperature environments than this, the built-in rechargeable battery may be hot or damaged. Also, the life become shortand the performance may deteriorate.•Never use other rechargers than the specified one. Product failure may occur.
4Wireless communicationHR-51 and HR-UC51 contain the built-in wireless device based on the Bluetooth wirelesstechnology.■Cautions for wireless communication•If the product is used near a wireless LAN device with the same frequency band as thatof HR-51 and HR-UC51, radio wave interference may occur and the communicationspeed becomes slow or communication may become impossible.•The communication may be impossible near equipment using the same frequency bandof electric wave as that of HR-51 and HR-UC51, such as microwave oven, industrialheating equipment and medical high-frequency equipment.•Communication may be impossible in the following locations- Locations near metallic objects or where there is much metallic powder- Locations surrounded by a metallic wall- Locations where the unit is subject to strong vibration•Communication-possible distance is approx. 10 m, however, depending on the environ-ment for use, communication may be impossible. Make sure to check the communica-tion condition before introduction.•With the frequency band for HR-51 and HR-UC51, premise radio stations (with licenserequired) and specified low power radio station (with license not required) for identifyingmobile objects used for industrial, scientific and medical equipment or product lines infactory are operating.•Before using HR-51 and HR-UC51, be sure to check that premise radio stations andspecified low power radio stations are not operating in the vicinity.•If radio wave interference occurs from HR-51 and HR-UC51 against premise radio sta-tions for identifying mobile objects, stop the electric wave generation, contact the follow-ing address and consult to take necessary measures (i.e. setting a partition) to avoidinterference.•If radio wave interference occur from HR-51 and HR-UC51 against specified low powerradio stations for identifying mobile objects or other problems occur, contact the follow-ing address.Contact address: KEYENCE CORPORATION, tel.:06-6379-11512.4  : This represents wireless equipment using2.4GHz band.FH : This represents the modulation method ofFH-SS.1 : This represents the assumed interferencedistance (≤ 10m): This represents the whole band is used andthe equipment range for identifying mobileobjects is unavoidable.CAUTIONNever disassemble or modify HR-51 and HR-UC51 as those conducts are pro-hibited by the Radio Law. HR-51 and HR-UC51 are regarded as specified lowpower radio devices and they obtained Construction Design Certificationaccording to the standard required by law.2.4 FH 1
5Safety Regulations and Standards■FDA regulationsHR-51 Series complies with FDA laser product regulation and is classified as class 2 laserproduct.Applicable regulation: 21 CFR Part 1040.10, 1040.11The classification is based on IEC60825-1 following the Laser Notice No. 50 from FDA(CDRH).■FCC regulationsHR-51 Series complies with the following FCC regulations.Applicable regulation : FCC Part 15 Subpart B, Class B digital devicesFCC Part 15 Subpart CFCC ID : RF40945A (HR-51)RF40945B (HR-UC51)FCC WARNINGChanges or modifications not expressly apprvoed by the party responsible for compli-ance could void the user’s authority to operate the equipment. This device complies withPart 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept anyinterference received, including interference that may cause undesired operation.NOTICEThe HR-51 and the HR-UC51 have been tested and found to comply with the limits for aClass B digital device, pursuant to part 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmful interference in a residential installation.The HR-51 and the HR-UC51 generate, use and can radiate radio frequency energy and,if not installed and used in accordance with the instructions, may cause harmful interfer-ence to radio communications. However, there is no guarantee that interference will notoccur in a particular installation. If the HR-51 and the HR-UC51 do cause harmful interfer-ence to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures:- Reorient or relocate the receiving antenna- Increase the separation between the equipment and receiver.- Connect the equipment into an outlet on a circuit different from that to which the receiveris connected.- Consult the dealer or an experienced radio/TV technician for help.
 6The HR-UC51 complied with FCC radiation exposure limits set forth for uncontrolledequipment and meets the FCC radio frequency (RF) Exposure Guidelines in SupplementC to OET65. The HR-UC51 has very low levels of RF energy that it deemed to complywithout maximum permissive exposure evaluation (MPE). But it is desirable that it shouldbe installed and operated with at least 20cm and more between the radiator and person’sbody (excluding extremities: hands, wrists, feet and legs).The HR-51 complies with FCC radiation exposure limits set forth for uncontrolled equip-ment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C toOET65. The HR-51 has very low levels of RF energy that it is deemed to comply withouttesting of specific absorption ratio (SAR).■CE MarkingHR-51 Series complies with the requirements of R&TTE Directive.Applicable standards : ETSI EN300 328ETSI EN301 489-1ETSI EN301 489-17EN60950-1EN60825-1, Laser Class2Overvoltage category : I (HR-51)II (HR-UC51)Pollution degree 2■EU Countries where HR-51 Series can be usedHR-51 Series can be used in the following EU countries.c Austria c Belgium c Cyprus c Czechc Denmark c Estonia c Finland c Francec Germany c Greece c Hungary c Irelandc Italy c Latvia c Lithuania c Luxemburgc Malta c Holland c Portuguese c Slovakiac Slovenia c Spain c Sweden c United Kingdomc Poland c Bulgaria c Romania
7MaintenanceClean the following parts of HR-51 and HR-UC51 periodically.•HR-51Clean the transmitter/receiver and recharge terminal.•HR-UC51Clean the recharge terminal.■How to cleanTransmitter/receiver : Wipe it lightly with an eyeglass cloth or a soft cloth moistened with aplastic cleaner.Recharge terminal : Wipe it lightly with a soft cloth moistened with alcohol.Transmitter/receiverRecharge terminalRecharge terminal
 8MEMO
1-11OverviewOverviewThis chapter explains the package contents list, part names andfunctions, and basic operations.1-1 Checking the Package Contents. . . . . . .  1-21-2 Part Names and Functions  . . . . . . . . . . .  1-51-3 Basic operations  . . . . . . . . . . . . . . . . . . .  1-8
1-21Overview1-1 Checking the Package ContentsHR-51 comes with the following items. Check that all of the items are included.Hand-held Laser Barcode Reader HR-51■Main unit: 1Model Communication interfaceHR-51 Bluetooth interface•HR-51 •Laser warning seal•Strap■User’s manual: 1Japanese/EnglishGermanFrenchChineseWirelessHand-held Barcode ReaderHR-51 SeriesUser’s ManualRead this manual before use in order to achieve maximumperformance.Keep this manual in a safe place after reading so that youcan use it at any time.
1-1 Checking the Package Contents1-31OverviewCommunication unit HR-UC51 (Dedicated use for HR-51)■Main unit: 1Model Communication interfaceHR-UC51 Bluetooth interface•HR-UC51 •BD address barcode label■Cables•RS-232C cable •USB Cable■AC adaptor: 1 ■Operating instructions: 1
1-1 Checking the Package Contents1-41OverviewOptions■Stand OP-87027•OP-87027: Use this stand when placing HR-51 on a table top■Stand OP-87026•OP-87026 : Use this stand when using HR-51 in detection mode, etc.■AC adaptor•OP-84372: AC100 to 240V applicable (Same as the supplied accessory for HR-UC51)
1-51Overview1-2 Part Names and FunctionsThis section explains the part names and functionsHR-51Trigger switch: Used when reading barcodes.HR-51Operation status LED: (  page 1-7)Transmitter/receiver: Emits laser beams and receivesthe reflected light.Recharge terminal
1-2 Part Names and Functions1-61OverviewHR-UC51HR-UC51: frontOperation status LED:(  page 1-7)Reader search button: Checks the connection ofHR-51 is established.The paired HR-51 sounds abuzzer.Recharge terminalbottomBD address barcodeUSB portRS-232C portPower terminalback
1-2 Part Names and Functions1-71OverviewOperation status LED■HR-51■HR-UC51LED color LED light-up timingGreen •When fully charged•When recognizing barcode in program modeRed•When reading the Setup barcode that cannot be set•When recharging•When read data cannot be transmittedOrange •When the remaining battery level is lowBlue•When the connection with HR-UC51 is established•When the transmission of read data is complete•When scanning the Setup barcodeLED numberLED color LED light-up timing➀Red When the power is turned on➁Green When data transmission is completeRed When data transmission is impossible➂BlueLights up: When the connection with HR-UC51 is establishedBlinks: When the connection is not yet established
1-81Overview1-3 Basic operationsThis section explains the basic operations of the barcode reader.Reading a barcodePoint the transmitter/receiver toward the barcode and press the trigger switch about 50 mmaway from the barcode.•When the barcode is read, the operation status LED (green) lights up and the buzzersounds.(You can make the setting for the operation status LED and the buzzer not to operate.)•The read barcode data is sent to the connected computer or other equipment.■Notes for readingAdjust the reading direction and reading timing so the laser beam can be emitted from theone end to the other end of barcode to scan correctly.•Correct scanning•Wrong scanningYou cannot specify which barcode to read
2-12ConnectionsConnectionsThis chapter explains the connection methods for HR-51 Series.2-1 Connecting HR-51 to HR-UC51 . . . . . . . . 2-22-2 Connecting HR-UC51. . . . . . . . . . . . . . . .  2-42-3 Recharging HR-51  . . . . . . . . . . . . . . . . . .  2-72-4 Checking the connected pairs  . . . . . . . .  2-92-5Wireless communication environment. . .  2-10
2-22Connections2-1 Connecting HR-51 to HR-UC51HR-51 and the communication unit HR-UC51 communicate in pairs. Before operation, besure to establish the connection (pairing) between HR-51 and the communication unit HR-UC51.Procedure1Press the “Trigger switch” to emit the laser beams.2Select the communication interface.(As a default setting, RS-232C interface has been selected.)3Read the BD address barcode attached to the communication unit or supplied BD addressbarcode.Note •HR-51 operates in fully-charged condition.•The communication unit HR-UC51 operates with the power ON.NoteWhen the connection (pairing) is not established, the following operations or conditionsresult.•After the barcode is read, the operation status LED of HR-51 lights red once and thebuzzer sounds.•LED ➂ of HR-UC51 blinks blue.Perform the following operations in this condition.•Note that even if you use more than 2 units of HR-51, communication is possible onlybetween connection-established HR-51 and the communication unit HR-UC51.50mm
2-1 Connecting HR-51 to HR-UC512-32ConnectionsWhen the connection (pairing) is established, the following conditions result.•After the barcode is read, the operation status LED of HR-51 lights blue once and thebuzzer sounds.•LED ➂ of HR-UC51 lights blue.Notes when the wireless connection is established between HR-51 and HR-UC51■For reading the barcodeYou cannot read the barcode in the establishment process with HR-UC51.■When multiple HR-51 and HR-UC 51 are connected•Only connected pairs can communicate.•If multiple HR-51 read the same address bar code of HR-UC51, only the first connec-tion-established HR-51 can communicate with HR-UC51. If you wish to change pairs ofHR-51 and HR-UC51, perform the same operation as described at “Changing pairs ofHR-51 and HR-UC51” below.■Changing pairs of HR-51 and HR-UC51If you change HR-51 in use to another HR-51, perform the following operations.Procedure1Cancel the connection of connection-established HR-51 in either way of the following.•Cut connection by reading the Connection-cut barcode.•Cut connection by pressing and holding the trigger key.•Cut connection automatically during wireless communication.2Read the BD address of HR-UC51 using another HR-51.CAUTIONIf you change the communication interface, turn OFF and ON once and read theBD address again. Otherwise, the unit may not operate normally (i.e. connectionfailure, transmission failure).Note If you restart HR-UC51, the connection of HR-UC51 will become unestablished. Makesure to establish 1 to 1 connection between HR-51 and HR-UC51.
2-42Connections2-2 Connecting HR-UC51After cables are connected, connect the communication unit to equipment with the connec-tion method according to the communication interface.Connecting to a computer using the USB interfaceConnect to the USB port of the computer. Compliant OS: Windows Vista/XP/2000/98■Notes when using the computer•Do not read a barcode while pressing down a key. Do not enter a key while receivingdata.•Set the input mode to “half-width alphanumeric characters”.•You can select keyboard specifications.Installing the USB driverWhen HR-UC51 is first connected to a Windows 98 PC, the USB driver installation screenappears. Install the driver according to the on-screen instructions.(Windows Vista, XP and 2000 do not require this operation.)Procedure1The “Add New Hardware Wizard” screen appears and the message “This windowsearches for new drivers for: USB human interface device” is displayed. Click “Next”.CAUTION Be sure to use the supplied AC adaptor or optional AC adaptor. Using otherpower sources may damage the unit.Note Connect the barcode reader after the startup of the computer. If it is connected with thepower OFF, start the computer.To computerUSB port(A type)HR-UC51
2-2 Connecting HR-UC512-52Connections2The message “What do you want Windows to do?” is displayed. Then select “Search forthe best driver for your device (Recommended)” and click “Next”.3Click on the “Next” button. “USB human interface device” is displayed and the message“Windows driver file search for the device” appears. Click “Next”.4Windows begins installing the driver. When installation is complete, the message “Win-dows has finished installing the software that your new hardware device requires.” appears.Click “Finish”.Connecting to a computer using the RS-232C interfaceThe barcode reader can directly connect to the serial port (RS-232C D-sub9 pin connector)of a DOSV computer. ■HR-UC51 connector pinNote The CD-ROM (Windows) may be required depending on the computer environment.CAUTION Be sure to use the supplied AC adaptor or optional AC adaptor. Using otherpower sources may damage the unit.Note DR (DSR) and ER (DTR) functions cannot be used.To computerRS-232C(D-sub9 pin)HR-UC51543219876Pin numberSymbol DescriptionSignal direction1 FG Frame Ground –2 SD (TXD) Sends Data Output3 RD (RXD) Receives Data Input4 DR (DSR) Data set ready Input5 SG Signal Ground –6 – Do not connect. –7 CS (CTS) Can Send Input8 RS (RTS) Requests to send data OutputD-sub9 pin (female)#4-40 screw
2-2 Connecting HR-UC512-62Connections■Communication settingsThe default settings for HR-UC51 are as follows. The setting values can be changed.Make sure that the settings for HR-UC51 and the connected computer are the same.•Baud rate : 9600bit/s•Data length : 7 bit•Parity : Even•Stop bit : 1 bit•Communication protocol : Non-procedure■Connecting to DV-90 SeriesTo connect to DV-90 Series, the conversion connecter is necessary as below.Use the following conversion connector.•Manufacturer : ELECOM Inc.•Product name : Serial Reverse Adaptor•Model : AD-R9CAUTION•Be sure to use the supplied AC adaptor or optional AC adaptor. Using otherpower sources may result in fire, electric shock or product malfunctions. •Power is supplied from the AC adaptor. Power is not supplied from the D-subconnector.DV90RS-232CConversion Connecter(D-sub9 pin)HR-UC51
2-72Connections2-3 Recharging HR-51Use the dedicated communication unit HR-UC51 to recharge HR-51.■Recharge method1Connect the supplied AC adaptor or optional AC adaptor to the communication unit HR-UC51 and confirm the power is ON.2Set HR-51 to the communication unit HR-UC51 so the recharge terminal of HR-UC51 isnot misaligned with that of HR-51.As soon as recharging starts, the operation status LED of HR-51 lights red.Recharging is complete when the operation status LED of HR-51 lights green.Note There is no remaining battery at the time of shipment. Be sure to charge the batterywhen using this product for the first time.Note Clean the recharge terminals of HR-51 and HR-UC51 periodically (  page 7).Dirt will interfere with recharging.
2-3 Recharging HR-512-82ConnectionsHR-51 rechargeable batteryIf the battery level of HR-51 becomes low, the operation status LED lights orange.Pay attention to the operation status LED while operating and recharge the battery whenevernecessary.■Continuous use timeThe following chart shows approximate continuous use time in each case after rechargingHR-51 is complete.*1 The battery is consumed even when not in use as HR-51 and HR-UC51 always communicates wirelessly.•It is recommended that HR-51 is set on HR-UC51 when not in use.■Recharge timeThe following chart shows approximate recharge time from battery level 0 to fully-chargedlevel.Conditions Approximate continuous use timeReading 1 time/5 sec. 15 hoursKeeping the connection *1 16 hoursWireless not connected 250 hoursNote•The above continuous use time is approximate and may become shorter dependingon the period of use.•If the continuous use time becomes extremely short, replace the battery. Consultyour nearest dealer.Recharge method Recharge timeWhen power is supplied from the AC adaptor Approx. 3 hoursWhen power is supplied from the USB bus power Approx. 6 hours
2-92Connections2-4 Checking the connected pairsChecking the connection pairs may be necessary in the environment that multiple HR-51 andthe communication unit HR-UC51 are used. For example, when you are not sure which com-munication unit is connection-established with HR-51, use this function.■How to check the connected pairsPress the “Reader search button” of the communication unit HR-UC51 while the connec-tion between HR-51 and HR-UC51 has been established.The paired HR-51 sounds a buzzer.Reader search button
2-102Connections2-5 Wireless communication environmentBluetooth Version 1.2 is used for the wireless communication between HR-51 and the com-munication unit HR-UC51. Use in the following environment.■Communication distance and surrounding environmentHR-51 and the communication unit HR-UC51 can communicate wirelessly within therange of approx. 10 m.However, the wireless communication is interrupted if obstacles such as concrete and ametal exist. Use in environments with no obstacles.Read “Cautions for wireless communication”. (  page 4)■Operations when the wireless communication is interruptedIf the communication is cut, the following operations result.•The operation status LED of HR-51 lights red once and the buzzer sounds.•The operation status LED ➂ of communication unit HR-UC51 blinks.When wireless communication becomes available, the setting is automatically restoredaccording to the setting contents of automatic reconnecting operation.If connection fails within the automatic reconnecting operation period, make connectionagain using either of the methods below.•Read “Connection-ON barcode”.•Read the readable barcode when “Automatic connection after reading the barcode”is “Enable”.•When “Connection on/cut by pressing down the trigger key” is “Enable”, press downthe trigger key for the set time for “Trigger key pressing-down time: Connection ON”.• Read the BD address of HR-UC51.Note If the BD address of UR-UC51 has not been registered on HR-51, read the BD addressof HR-UC51 before connection.Obstacle
A-1AppendixAppendixA-1 Specifications. . . . . . . . . . . . . . . . . . . . . . A-2A-2 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . A-5
A-2AppendixA-1 SpecificationsHR-51 Series General specificationsModel HR-51Interface Bluetooth communication typeLight source Visible red semiconductor laser (Wavelength: 650 nm)Maximum output 1mW or lessClass CLASS 2 (IEC60825-1)Reading distance See the characteristic range for reading (20 to 500 mm)Reading width See the characteristic range for readingMinimum resolution 0.127mmPCS 0.45 or moreScan rate 100 scans per secondSupported codes Code39, ITF, NW-7, JAN/EAN/UPC (add-on support), Code128, GS1-128 (EAN-128), GS1 DataBar, Code93, Industrial 2of5EnvironmentresistanceDrop impact 1.5mAmbient temperature –5 to +40°CStorage ambient temperature –20 to +60°CAmbient light Sunlight: 50000 lx or less, fluorescent lamp: 3000 lx or lessAmbient humidity 5 to 95%RH, No condensationStorage ambient humidity 5 to 95%RH, No condensationOperating atmosphere No dust or corrosive gas presentProtection structure IP42WeightApprox. 118 gModel HR-51Wireless communicationpartWireless standard Bluetooth Ver1.2Wireless frequency2402MHz to 2480MHzCommunicationoutput CLASS 2 (max. 2.5 m)Communicationdistance Scope 10mBuilt-in battery Lithium ion battery, continuous use time: 16 hours
A-1  SpecificationsA-3AppendixHR-UC51 General specifications (Communication unit dedicated for HR-51)Model HR-UC51Wired communicationpartCommunicationstandardUSB Ver2.0 (HID class) compliant RS-232C compliantConnector shape USB (B type) D-sub9 pin (female)Wireless communicationpartWireless standard Bluetooth Ver2.0Wireless frequency2402MHz to 2480MHzCommunicationoutput CLASS 2 (max. 2.5 m)Communicationdistance Scope 10mRechargepartRecharge system Constant-current and constant-voltage systemRecharge time AC adaptor: approx. 3 hoursUSB bus power: approx. 6 hoursEnvironmentresistanceAmbient temperature –5 to +40°CStorage ambient temperature –20 to +60°CAmbient humidity 25 to 85% RH, No freeze or condensationStorage ambient humidity 20 to 90% RH, No freeze or condensationOperating atmosphere No dust or corrosive gas presentDimensions 78×100×185mmWeight Approx. 230 g (excluding cables)AC adaptor specifications See OP-84372 specifications.
A-1  SpecificationsA-4Appendix■Interface specificationsUSB interfaceRS-232C interfaceUSB version USB-HID FullspeedCompliant OS Windows Vista/XP/2000/98Format of sent data Same as data sent from keyboardSynchronization method Start-stop synchronizationTransmission code ASCII codeBaud rate 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600bit/sData length 7/8 bitParity check None/Even/OddStop bit length 1/2 bitFlow control Non
A-5AppendixA-2 Dimensions■HR-51 (Unit: mm)■HR-UC51 (Unit: mm)5629112.82513210070 601858350
A-2  DimensionsA-6Appendix■Supplied cables•RS-232C cable (Unit: mm)•USB cable■AC adaptor•OP-84372 (supplied with HR-UC51) (Unit: mm)1500D-SUB9PINFEMALE1500USB-B connector USB-A connector18001800722747
A-2  DimensionsA-7Appendix■Stand OP-87027•OP-87027 (Unit: mm)44.5 8571 75
A-2  DimensionsA-8Appendix■Stand OP-87026•OP-87026 (Unit: mm)106146726464170134295
Warranty1 Warranty periodOne-year warranty is provided for this product after it is delivered to the designated place.2 Warranty scope(1) If failure occurs under KEYENCE responsibility during the above warranty period, free repairservice is provided.However, the following cases are excluded from the warranty scope.➀Malfunctions caused by improper conditions, environments, handling and operationsother than those described in the operating instructions, user’s manual and separatelyprovided specifications.➁Malfunctions caused by user’s device or design contents of software except for KEYENCE products.➂Malfunctions caused by modification or service done by other parties than KEYENCE.➃Malfunctions that could have been prevented if the consumable parts described in theoperating instructions or user’s manual had been properly maintained and replaced.➄Malfunctions that were not foreseeable with the technology at the time of shipment.➅Malfunctions caused by other external factors irrelevant to KEYENCE (i.e.,  fire, earth-quake, flood, etc.)The limit of warranty period is as described above (1). KEYENCE will not responsible for secondarydamages (device damage, opportunity loss, lost earnings, etc.) and any other damages on user’sside resulted from malfunctions of KEYENCE products.3 Applicable scope of productKEYENCE products are designed and manufactured as general-purpose products for generalindustrial use.The following uses are not intended and are out of applicable scope.However, if a user consults KEYENCE beforehand, confirms the product specifications under theuserfs responsibility, approves the rating and performance, and then take necessary safety mea-sures, the use is applicable.Even in this case, the warranty scope is the same as described above.➀For use with facilities where death or serious property damage are possible, such asnuclear power generation, aircraft, railway, ship, vehicles, medical equipment, etc.➁For use with public facilities such as electricity, gas, water, etc.➂For use outdoors and in similar conditions and environments
Copyright (c) 2009 KEYENCE CORPORATION. All rights reserved.   Printed in JapanKEYENCE CORPORATION OF AMERICA50 Tice Blvd., Woodcliff Lake, NJ 07677    PHONE: 1-201-930-0100