Keyence 0945A Wireless Barcode scanner User Manual HR 51 Series E
Keyence Corporation Wireless Barcode scanner HR 51 Series E
Keyence >
Manual
Wireless Hand-held Barcode Reader HR-51 Series User’s Manual Read this manual before use in order to achieve maximum performance. Keep this manual in a safe place after reading so that you can use it at any time. Introduction This manual contains information about procedures for handling, operations, warnings, and precautions about “Hand-held Barcode Reader HR-51 Series”. Make sure to read this manual before use. Keep this manual in a safe place for future reference. ■ Symbols This manual uses the following symbols that alert you to important messages. Be sure to read these messages carefully. DANGER Failure to follow instructions and mishandling the product may lead to death or serious injury. WARNING Failure to follow instructions may lead to physical injury (i.e., electric shock, burns, etc.). CAUTION Failure to follow instructions may lead to the product malfunctions. Note Provides additional information on proper operations that can be easily mistaken. Indicates reference pages in this manual or other manuals. ■ General Precautions • At startup and during operation, be sure to monitor the functions and performance of HR-51 and confirm the normal operation. • We recommend that you take substantial safety measures to avoid any damage in the event the HR-51 series malfunctions. • If the product is modified or used in any way other than described in the specifications, its functions and performance cannot be guaranteed. • When the HR-51 series is used in combination with other devices, the functions and performance may be degraded, depending on the operating conditions, surrounding environment, etc.. • Do not use the HR-51 series for the purpose of protecting the human body. ■ Notice When this product is used under the circumstances and operating environments described below, adhere to the limitations of the ratings, take adequate measures to ensure safety such as fail-safe installations and consult a KEYENCE sales representative. • For use under circumstances or environments which are not described in the manual. • For use with nuclear power control, railway, aircraft, vehicles, incinerators, medical equipment, entertainment equipment, safety devices, etc. • For use in applications where death or serious property damage is possible and extensive safety precautions are required. Safety Precautions ■ Safety Precautions on Laser Apparatus WARNING Use of controls or adjustments or performunce of procedures other than those specified herein may result in hazardous radiation exposure. The “Hand-held Barcode Reader HR-51 Series” employs a visible red semiconductor laser for its light source. HR-51 has a wavelength of 650 nm and is classified as a Class 2 laser under IEC standard (IEC60825-1: “Safety of Laser Products”). Model HR-51 Wavelength 650nm Maximum output 1.0mW Class CLASS 2 (IEC60825-1) • Do not directly stare into the laser beams or specularly reflected light. Doing so may result in serious eye injury. Do not direct laser beams towards a human body intentionally although laser beams will not cause damage even if it strikes exposed skin. • Never disassemble HR-51. HR-51 is not equipped with a mechanism to stop WARNING laser emission when disassembled. If HR-51 is disassembled, laser beams emitted from HR-51 may cause eye injury. • Before cleaning the transmitter/receiver part of laser scanner, be sure to stop the emission of laser beams. Otherwise, exposure to the laser may cause eye injury. • Be careful of the light path of laser beams. Be especially careful of the specularly reflected light. Do not install HR-51 in such a way that the laser beam passes at eye height when operating HR-51. ■ Warning label locations HR-51 Operating Precautions ■ Precautions on use • Do not disassemble or modify this unit. Doing so may lead to product failure. • This unit is a precision instrument. Dropping the unit or subjecting it to shock may cause damage. Take enough care when carrying or using this unit. • Locate cables as far as possible from high-voltage lines and power lines. Otherwise, generated noise may cause product failure or operation error. • Do not hold the unit by its cable when carrying. The HR-51 may strike the wall and may be damaged. Also due to the stress on the cables, the wires may be broken. • Be sure to use the supplied AC adaptor or optional AC adaptor for HRUC51. Using other AC adaptors than these may result in fire, electric shock or product failures. • Be sure to periodically clean the power connection part of AC adaptor connected to HR-UC51 as it tends to catch dust. Tracking phenomenon may result in fire. Also, disconnect the AC adaptor from the outlet if not using a long period of time. CAUTION • When recharging HR-51 on HR-UC51, be sure to check no foreign objects are attached to the recharge terminal. Foreign objects may cause fire. ■ Environments for use Do not use in the following locations. Product failure or mechanical error may occur. • • • • • • • Locations where the ambient temperature is beyond specified range Locations where the ambient humidity is beyond specified range Locations where the unit is exposed to direct sunlight High-temperature locations such as inside a closed car Locations where condensation occurs due to the rapid humidity change Locations where there are corrosive gas or combustible gas Locations where there is a large amount of airborne dust, salt, iron, and greasy fumes • Locations where the unit may be directly subjected to vibration or impact • Locations where water, oil or chemicals may splash onto the unit • Locations where a strong magnetic or electric field is generated Precautions for using the built-in rechargeable battery HR-51 contains the built-in lithium ion rechargeable battery. Observe the following precautions for proper use. On disposal, follow the disposal procedure specified by each local government. • Stop the recharging process if recharging does not finish even after the specified recharge time. The built-in rechargeable battery may become hot, explode or cause fire. • If there is leak or abnormal smell from the built-in rechargeable battery, keep it DANGER away from fire immediately. The battery electrolyte may catch fire, resulting in explosion and ignition. • Never put it into the fire. The explosion of built-in rechargeable battery may lead to a serious accident. • Never put it into the water. The chemical reaction of the built-in rechargeable battery may lead to an accident. • In the event that the leaked liquid comes into the eye, do not wipe it. Clean it WARNING immediately with clean water instead and go to the eye specialist. If the eye is left untreated, eye damage may result. • In the event the liquid leaked from the built-in rechargeable battery is attached to the skin, wash it immediately with clean water. Otherwise, skin irritation may occur. • Do not leave or use it in a heated car, under the scorching sun or at highhumidity locations. The built-in rechargeable battery may become hot or cause fire. Also, the battery life may become short and the performance may deteriorate. CAUTION • Recharge and use the built-in battery in the temperature environment of –5 to 140 degree. If it is used in other temperature environments than this, the builtin rechargeable battery may be hot or damaged. Also, the life become short and the performance may deteriorate. • Never use other rechargers than the specified one. Product failure may occur. Wireless communication HR-51 and HR-UC51 contain the built-in wireless device based on the Bluetooth wireless technology. CAUTION Never disassemble or modify HR-51 and HR-UC51 as those conducts are prohibited by the Radio Law. HR-51 and HR-UC51 are regarded as specified low power radio devices and they obtained Construction Design Certification according to the standard required by law. ■ Cautions for wireless communication • If the product is used near a wireless LAN device with the same frequency band as that of HR-51 and HR-UC51, radio wave interference may occur and the communication speed becomes slow or communication may become impossible. • The communication may be impossible near equipment using the same frequency band of electric wave as that of HR-51 and HR-UC51, such as microwave oven, industrial heating equipment and medical high-frequency equipment. • Communication may be impossible in the following locations - Locations near metallic objects or where there is much metallic powder - Locations surrounded by a metallic wall - Locations where the unit is subject to strong vibration • Communication-possible distance is approx. 10 m, however, depending on the environment for use, communication may be impossible. Make sure to check the communication condition before introduction. • With the frequency band for HR-51 and HR-UC51, premise radio stations (with license required) and specified low power radio station (with license not required) for identifying mobile objects used for industrial, scientific and medical equipment or product lines in factory are operating. • Before using HR-51 and HR-UC51, be sure to check that premise radio stations and specified low power radio stations are not operating in the vicinity. • If radio wave interference occurs from HR-51 and HR-UC51 against premise radio stations for identifying mobile objects, stop the electric wave generation, contact the following address and consult to take necessary measures (i.e. setting a partition) to avoid interference. • If radio wave interference occur from HR-51 and HR-UC51 against specified low power radio stations for identifying mobile objects or other problems occur, contact the following address. Contact address: KEYENCE CORPORATION, tel.:06-6379-1151 2.4 2.4 FH FH : This represents wireless equipment using 2.4GHz band. : This represents the modulation method of FH-SS. : This represents the assumed interference distance (≤ 10m) : This represents the whole band is used and the equipment range for identifying mobile objects is unavoidable. Safety Regulations and Standards ■ FDA regulations HR-51 Series complies with FDA laser product regulation and is classified as class 2 laser product. Applicable regulation: 21 CFR Part 1040.10, 1040.11 The classification is based on IEC60825-1 following the Laser Notice No. 50 from FDA (CDRH). ■ FCC regulations HR-51 Series complies with the following FCC regulations. Applicable regulation : FCC Part 15 Subpart B, Class B digital devices FCC Part 15 Subpart C FCC ID : RF40945A (HR-51) RF40945B (HR-UC51) FCC WARNING Changes or modifications not expressly apprvoed by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTICE The HR-51 and the HR-UC51 have been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The HR-51 and the HR-UC51 generate, use and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the HR-51 and the HR-UC51 do cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. The HR-UC51 complied with FCC radiation exposure limits set forth for uncontrolled equipment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. The HR-UC51 has very low levels of RF energy that it deemed to comply without maximum permissive exposure evaluation (MPE). But it is desirable that it should be installed and operated with at least 20cm and more between the radiator and person’s body (excluding extremities: hands, wrists, feet and legs). The HR-51 complies with FCC radiation exposure limits set forth for uncontrolled equipment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. The HR-51 has very low levels of RF energy that it is deemed to comply without testing of specific absorption ratio (SAR). ■ CE Marking HR-51 Series complies with the requirements of R&TTE Directive. Applicable standards : ETSI EN300 328 ETSI EN301 489-1 ETSI EN301 489-17 EN60950-1 EN60825-1, Laser Class2 Overvoltage category : I (HR-51) II (HR-UC51) Pollution degree ■ EU Countries where HR-51 Series can be used HR-51 Series can be used in the following EU countries. c Austria c Belgium c Cyprus c Denmark c Estonia c Finland c Germany c Greece c Hungary c Italy c Latvia c Lithuania c Malta c Holland c Portuguese c Slovenia c Spain c Sweden c Poland c Bulgaria c Romania c Czech c France c Ireland c Luxemburg c Slovakia c United Kingdom Maintenance Clean the following parts of HR-51 and HR-UC51 periodically. • HR-51 Clean the transmitter/receiver and recharge terminal. Recharge terminal Transmitter/receiver • HR-UC51 Clean the recharge terminal. Recharge terminal ■ How to clean Transmitter/receiver : Wipe it lightly with an eyeglass cloth or a soft cloth moistened with a plastic cleaner. Recharge terminal : Wipe it lightly with a soft cloth moistened with alcohol. MEMO 1 Overview Overview This chapter explains the package contents list, part names and functions, and basic operations. 1-1 Checking the Package Contents. . . . . . . 1-2 1-2 Part Names and Functions . . . . . . . . . . . 1-5 1-3 Basic operations . . . . . . . . . . . . . . . . . . . 1-8 1-1 1-1 Checking the Package Contents HR-51 comes with the following items. Check that all of the items are included. Hand-held Laser Barcode Reader HR-51 Overview ■ Main unit: 1 Model Communication interface HR-51 Bluetooth interface • HR-51 • Laser warning seal Japanese/English German French Chinese • Strap ■ User’s manual: 1 Wireless Hand-held Barcode Reader HR-51 Series User’s Manual Read this manual before use in order to achieve maximum performance. Keep this manual in a safe place after reading so that you can use it at any time. 1-2 1-1 Checking the Package Contents Communication unit HR-UC51 (Dedicated use for HR-51) ■ Main unit: 1 Model Communication interface HR-UC51 Bluetooth interface Overview • HR-UC51 • BD address barcode label ■ Cables • RS-232C cable ■ AC adaptor: 1 • USB Cable ■ Operating instructions: 1 1-3 1-1 Checking the Package Contents Options ■ Stand OP-87027 • OP-87027: Use this stand when placing HR-51 on a table top Overview ■ Stand OP-87026 • OP-87026 : Use this stand when using HR-51 in detection mode, etc. ■ AC adaptor • OP-84372: AC100 to 240V applicable (Same as the supplied accessory for HR-UC51) 1-4 1-2 Part Names and Functions This section explains the part names and functions HR-51 Overview HR-51 Operation status LED: page 1-7) Transmitter/receiver: Emits laser beams and receives the reflected light. Trigger switch: Used when reading barcodes. Recharge terminal 1-5 1-2 Part Names and Functions HR-UC51 HR-UC51: front Operation status LED: page 1-7) Overview Reader search button: Checks the connection of HR-51 is established. The paired HR-51 sounds a buzzer. Recharge terminal back bottom Power terminal USB port RS-232C port BD address barcode 1-6 1-2 Part Names and Functions Operation status LED ■ HR-51 LED color Green Orange Blue • When reading the Setup barcode that cannot be set • When recharging • When read data cannot be transmitted Overview Red LED light-up timing • When fully charged • When recognizing barcode in program mode • When the remaining battery level is low • When the connection with HR-UC51 is established • When the transmission of read data is complete • When scanning the Setup barcode ■ HR-UC51 LED number ➀ ➁ ➂ LED color Red Green LED light-up timing When the power is turned on When data transmission is complete Red When data transmission is impossible Blue Lights up: When the connection with HR-UC51 is established Blinks: When the connection is not yet established 1-7 1-3 Basic operations This section explains the basic operations of the barcode reader. Reading a barcode Overview Point the transmitter/receiver toward the barcode and press the trigger switch about 50 mm away from the barcode. • When the barcode is read, the operation status LED (green) lights up and the buzzer sounds. (You can make the setting for the operation status LED and the buzzer not to operate.) • The read barcode data is sent to the connected computer or other equipment. ■ Notes for reading Adjust the reading direction and reading timing so the laser beam can be emitted from the one end to the other end of barcode to scan correctly. • Correct scanning • Wrong scanning You cannot specify which barcode to read 1-8 Connections 2-1 Connecting HR-51 to HR-UC51 . . . . . . . . 2-2 2-2 Connecting HR-UC51 . . . . . . . . . . . . . . . . 2-4 2-3 Recharging HR-51 . . . . . . . . . . . . . . . . . . 2-7 2-4 Checking the connected pairs . . . . . . . . 2-9 2-5 Wireless communication environment. . . 2-10 2-1 Connections This chapter explains the connection methods for HR-51 Series. 2-1 Connecting HR-51 to HR-UC51 HR-51 and the communication unit HR-UC51 communicate in pairs. Before operation, be sure to establish the connection (pairing) between HR-51 and the communication unit HRUC51. Note • HR-51 operates in fully-charged condition. • The communication unit HR-UC51 operates with the power ON. Procedure Connections When the connection (pairing) is not established, the following operations or conditions result. • After the barcode is read, the operation status LED of HR-51 lights red once and the Note buzzer sounds. • LED ➂ of HR-UC51 blinks blue. Perform the following operations in this condition. • Note that even if you use more than 2 units of HR-51, communication is possible only between connection-established HR-51 and the communication unit HR-UC51. 1 Press the “Trigger switch” to emit the laser beams. 2 Select the communication interface. (As a default setting, RS-232C interface has been selected.) 3 Read the BD address barcode attached to the communication unit or supplied BD address barcode. 50mm 2-2 2-1 Connecting HR-51 to HR-UC51 When the connection (pairing) is established, the following conditions result. • After the barcode is read, the operation status LED of HR-51 lights blue once and the buzzer sounds. • LED ➂ of HR-UC51 lights blue. CAUTION If you change the communication interface, turn OFF and ON once and read the BD address again. Otherwise, the unit may not operate normally (i.e. connection failure, transmission failure). Notes when the wireless connection is established between HR-51 and HR-UC51 Connections ■ For reading the barcode You cannot read the barcode in the establishment process with HR-UC51. ■ When multiple HR-51 and HR-UC 51 are connected • Only connected pairs can communicate. • If multiple HR-51 read the same address bar code of HR-UC51, only the first connection-established HR-51 can communicate with HR-UC51. If you wish to change pairs of HR-51 and HR-UC51, perform the same operation as described at “Changing pairs of HR-51 and HR-UC51” below. ■ Changing pairs of HR-51 and HR-UC51 If you change HR-51 in use to another HR-51, perform the following operations. Procedure 1 Cancel the connection of connection-established HR-51 in either way of the following. • Cut connection by reading the Connection-cut barcode. • Cut connection by pressing and holding the trigger key. • Cut connection automatically during wireless communication. 2 Read the BD address of HR-UC51 using another HR-51. Note If you restart HR-UC51, the connection of HR-UC51 will become unestablished. Make sure to establish 1 to 1 connection between HR-51 and HR-UC51. 2-3 2-2 Connecting HR-UC51 After cables are connected, connect the communication unit to equipment with the connection method according to the communication interface. Connecting to a computer using the USB interface Connect to the USB port of the computer. Compliant OS: Windows Vista/XP/2000/98 HR-UC51 Connections To computer USB port (A type) CAUTION Be sure to use the supplied AC adaptor or optional AC adaptor. Using other power sources may damage the unit. ■ Notes when using the computer • Do not read a barcode while pressing down a key. Do not enter a key while receiving data. • Set the input mode to “half-width alphanumeric characters”. • You can select keyboard specifications. Installing the USB driver When HR-UC51 is first connected to a Windows 98 PC, the USB driver installation screen appears. Install the driver according to the on-screen instructions. (Windows Vista, XP and 2000 do not require this operation.) Note Connect the barcode reader after the startup of the computer. If it is connected with the power OFF, start the computer. Procedure 1 The “Add New Hardware Wizard” screen appears and the message “This window searches for new drivers for: USB human interface device” is displayed. Click “Next”. 2-4 2-2 Connecting HR-UC51 2 The message “What do you want Windows to do?” is displayed. Then select “Search for the best driver for your device (Recommended)” and click “Next”. 3 Click on the “Next” button. “USB human interface device” is displayed and the message “Windows driver file search for the device” appears. Click “Next”. Note The CD-ROM (Windows) may be required depending on the computer environment. 4 Windows begins installing the driver. When installation is complete, the message “Win- 2 dows has finished installing the software that your new hardware device requires.” appears. Click “Finish”. The barcode reader can directly connect to the serial port (RS-232C D-sub9 pin connector) of a DOSV computer. HR-UC51 To computer RS-232C (D-sub9 pin) CAUTION Be sure to use the supplied AC adaptor or optional AC adaptor. Using other power sources may damage the unit. ■ HR-UC51 connector pin 54321 9876 D-sub9 pin (female) #4-40 screw Note Pin number Symbol Description FG Frame Ground Signal direction – SD (TXD) Sends Data Output RD (RXD) Receives Data Input DR (DSR) Data set ready Input SG Signal Ground – – Do not connect. – CS (CTS) Can Send Input RS (RTS) Requests to send data Output DR (DSR) and ER (DTR) functions cannot be used. 2-5 Connections Connecting to a computer using the RS-232C interface 2-2 Connecting HR-UC51 ■ Communication settings The default settings for HR-UC51 are as follows. The setting values can be changed. Make sure that the settings for HR-UC51 and the connected computer are the same. • Baud rate : 9600bit/s • Data length : 7 bit • Parity : Even • Stop bit : 1 bit • Communication protocol : Non-procedure ■ Connecting to DV-90 Series To connect to DV-90 Series, the conversion connecter is necessary as below. Connections Conversion Connecter HR-UC51 DV90 RS-232C (D-sub9 pin) Use the following conversion connector. • Manufacturer : ELECOM Inc. • Product name : Serial Reverse Adaptor • Model : AD-R9 • Be sure to use the supplied AC adaptor or optional AC adaptor. Using other CAUTION power sources may result in fire, electric shock or product malfunctions. • Power is supplied from the AC adaptor. Power is not supplied from the D-sub connector. 2-6 2-3 Recharging HR-51 Use the dedicated communication unit HR-UC51 to recharge HR-51. Note There is no remaining battery at the time of shipment. Be sure to charge the battery when using this product for the first time. ■ Recharge method 1 Connect the supplied AC adaptor or optional AC adaptor to the communication unit HR- 2 UC51 and confirm the power is ON. not misaligned with that of HR-51. As soon as recharging starts, the operation status LED of HR-51 lights red. Recharging is complete when the operation status LED of HR-51 lights green. Note Clean the recharge terminals of HR-51 and HR-UC51 periodically ( Dirt will interfere with recharging. page 7). 2-7 Connections 2 Set HR-51 to the communication unit HR-UC51 so the recharge terminal of HR-UC51 is 2-3 Recharging HR-51 HR-51 rechargeable battery If the battery level of HR-51 becomes low, the operation status LED lights orange. Pay attention to the operation status LED while operating and recharge the battery whenever necessary. ■ Continuous use time The following chart shows approximate continuous use time in each case after recharging HR-51 is complete. Conditions Reading 1 time/5 sec. Approximate continuous use time 15 hours Connections Keeping the connection *1 16 hours Wireless not connected 250 hours *1 The battery is consumed even when not in use as HR-51 and HR-UC51 always communicates wirelessly. • It is recommended that HR-51 is set on HR-UC51 when not in use. • The above continuous use time is approximate and may become shorter depending Note on the period of use. • If the continuous use time becomes extremely short, replace the battery. Consult your nearest dealer. ■ Recharge time The following chart shows approximate recharge time from battery level 0 to fully-charged level. Recharge method 2-8 Recharge time When power is supplied from the AC adaptor Approx. 3 hours When power is supplied from the USB bus power Approx. 6 hours 2-4 Checking the connected pairs Checking the connection pairs may be necessary in the environment that multiple HR-51 and the communication unit HR-UC51 are used. For example, when you are not sure which communication unit is connection-established with HR-51, use this function. ■ How to check the connected pairs Press the “Reader search button” of the communication unit HR-UC51 while the connection between HR-51 and HR-UC51 has been established. Connections Reader search button The paired HR-51 sounds a buzzer. 2-9 2-5 Wireless communication environment Bluetooth Version 1.2 is used for the wireless communication between HR-51 and the communication unit HR-UC51. Use in the following environment. ■ Communication distance and surrounding environment HR-51 and the communication unit HR-UC51 can communicate wirelessly within the range of approx. 10 m. However, the wireless communication is interrupted if obstacles such as concrete and a metal exist. Use in environments with no obstacles. Obstacle Connections Read “Cautions for wireless communication”. ( page 4) ■ Operations when the wireless communication is interrupted If the communication is cut, the following operations result. • The operation status LED of HR-51 lights red once and the buzzer sounds. • The operation status LED ➂ of communication unit HR-UC51 blinks. When wireless communication becomes available, the setting is automatically restored according to the setting contents of automatic reconnecting operation. If connection fails within the automatic reconnecting operation period, make connection again using either of the methods below. • Read “Connection-ON barcode”. • Read the readable barcode when “Automatic connection after reading the barcode” is “Enable”. • When “Connection on/cut by pressing down the trigger key” is “Enable”, press down the trigger key for the set time for “Trigger key pressing-down time: Connection ON”. • Read the BD address of HR-UC51. Note 2-10 If the BD address of UR-UC51 has not been registered on HR-51, read the BD address of HR-UC51 before connection. Appendix A-1 Specifications . . . . . . . . . . . . . . . . . . . . . . A-2 A-1 Appendix A-2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . A-5 A-1 Specifications HR-51 Series General specifications Model HR-51 Interface Bluetooth communication type Light source Visible red semiconductor laser (Wavelength: 650 nm) Maximum output Class Reading distance Reading width PCS 100 scans per second Appendix Code39, ITF, NW-7, JAN/EAN/UPC (add-on support), Code128, GS1-128 (EAN-128), GS1 DataBar, Code93, Industrial 2of5 Supported codes Drop impact 1.5m Ambient temperature –5 to +40°C Storage ambient temperature –20 to +60°C Ambient light 5 to 95%RH, No condensation Storage ambient humidity 5 to 95%RH, No condensation Protection structure No dust or corrosive gas present IP42 Approx. 118 g Weight Model A-2 Sunlight: 50000 lx or less, fluorescent lamp: 3000 lx or less Ambient humidity Operating atmosphere Built-in battery 0.127mm 0.45 or more Scan rate Wireless communication part See the characteristic range for reading (20 to 500 mm) See the characteristic range for reading Minimum resolution Environment resistance 1mW or less CLASS 2 (IEC60825-1) HR-51 Wireless standard Bluetooth Ver1.2 Wireless frequency 2402MHz to 2480MHz Communication output CLASS 2 (max. 2.5 m) Communication distance Scope 10m Lithium ion battery, continuous use time: 16 hours A-1 Specifications HR-UC51 General specifications (Communication unit dedicated for HR-51) Model Wired communication part Wireless communication part HR-UC51 Communication standard Connector shape USB (B type) D-sub9 pin (female) Bluetooth Ver2.0 Wireless frequency 2402MHz to 2480MHz Communication output CLASS 2 (max. 2.5 m) Communication distance Scope 10m Recharge time Constant-current and constant-voltage system AC adaptor: approx. 3 hours USB bus power: approx. 6 hours Ambient temperature –5 to +40°C Storage ambient temperature –20 to +60°C Ambient humidity 25 to 85% RH, No freeze or condensation Storage ambient humidity 20 to 90% RH, No freeze or condensation Operating atmosphere Dimensions Weight AC adaptor specifications Appendix Environment resistance RS-232C compliant Wireless standard Recharge system Recharge part USB Ver2.0 (HID class) compliant No dust or corrosive gas present 78×100×185mm Approx. 230 g (excluding cables) See OP-84372 specifications. A-3 A-1 Specifications ■ Interface specifications USB interface USB version USB-HID Fullspeed Compliant OS Windows Vista/XP/2000/98 Format of sent data Same as data sent from keyboard RS-232C interface Synchronization method Appendix A-4 Start-stop synchronization Transmission code ASCII code Baud rate 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600bit/s Data length 7/8 bit Parity check None/Even/Odd Stop bit length 1/2 bit Flow control Non A-2 Dimensions ■ HR-51 (Unit: mm) 56 112.8 29 25 132 Appendix ■ HR-UC51 (Unit: mm) 60 70 83 50 100 185 A-5 A-2 Dimensions ■ Supplied cables • RS-232C cable (Unit: mm) 1500 D-SUB9PIN FEMALE • USB cable 1500 Appendix USB-B connector USB-A connector ■ AC adaptor • OP-84372 (supplied with HR-UC51) (Unit: mm) 47 27 1800 72 1800 A-6 A-2 Dimensions ■ Stand OP-87027 • OP-87027 (Unit: mm) 71 44.5 75 85 Appendix A-7 A-2 Dimensions ■ Stand OP-87026 • OP-87026 (Unit: mm) 64 72 64 Appendix 134 295 170 106 146 A-8 Warranty Warranty period One-year warranty is provided for this product after it is delivered to the designated place. Warranty scope (1) If failure occurs under KEYENCE responsibility during the above warranty period, free repair service is provided. However, the following cases are excluded from the warranty scope. ➀ Malfunctions caused by improper conditions, environments, handling and operations other than those described in the operating instructions, user’s manual and separately provided specifications. ➁ Malfunctions caused by user’s device or design contents of software except for KEYENCE products. ➂ Malfunctions caused by modification or service done by other parties than KEYENCE. ➃ Malfunctions that could have been prevented if the consumable parts described in the operating instructions or user’s manual had been properly maintained and replaced. ➄ Malfunctions that were not foreseeable with the technology at the time of shipment. ➅ Malfunctions caused by other external factors irrelevant to KEYENCE (i.e., fire, earthquake, flood, etc.) The limit of warranty period is as described above (1). KEYENCE will not responsible for secondary damages (device damage, opportunity loss, lost earnings, etc.) and any other damages on user’s side resulted from malfunctions of KEYENCE products. Applicable scope of product KEYENCE products are designed and manufactured as general-purpose products for general industrial use. The following uses are not intended and are out of applicable scope. However, if a user consults KEYENCE beforehand, confirms the product specifications under the userfs responsibility, approves the rating and performance, and then take necessary safety measures, the use is applicable. Even in this case, the warranty scope is the same as described above. ➀ For use with facilities where death or serious property damage are possible, such as nuclear power generation, aircraft, railway, ship, vehicles, medical equipment, etc. ➁ For use with public facilities such as electricity, gas, water, etc. ➂ For use outdoors and in similar conditions and environments KEYENCE CORPORATION OF AMERICA 50 Tice Blvd., Woodcliff Lake, NJ 07677 PHONE: 1-201-930-0100 Copyright (c) 2009 KEYENCE CORPORATION. All rights reserved. Printed in Japan
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-702 GTS PDFX Conformance : PDF/X-1a:2001 GTS PDFX Version : PDF/X-1:2001 Trapped : False Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:03:27 15:02:10+08:00 Create Date : 2009:03:12 10:55:40+09:00 Metadata Date : 2009:03:27 15:02:10+08:00 Format : application/pdf Title : HR-51 Series_E.book Creator : hamada-ma Document ID : uuid:d6e976e9-f8ce-4709-b83d-ddd0622b1e62 Instance ID : uuid:ce21e5ae-0150-4c70-93c1-ca17fe5f8d2c Has XFA : No Page Count : 38 Author : hamada-maEXIF Metadata provided by EXIF.tools