LG CNS KSCCCBR310 ATTENDED RECHARGER User Manual WIDTHBMYMPHY
LG CNS CO., LTD. ATTENDED RECHARGER WIDTHBMYMPHY
LG CNS >
Users Manual
Sistema de Recaudo Control e Información y Servicio al Usuario Proyect Maintenance and Repair Manual (Heavy) Equipment Name CB-EDR-HM-00-V1.0 Copyright ⓒ LG CNS It is forbidden to copy and distribute on certain or whole part of this content without precedent approval of LG CNS Bogota SIRCI Project Document Maintenance and Repair Manual (Heavy) CB-EDR-HM-00-V1.0 User Requirement Definition Prepared by: Attended Recharger Reviewed by: Approved by: Page i of All Bogota SIRCI Project User Requirement Definition Document History Previous Version Present Document CB-EDR-HM-00-V1.0 Date Numeral Attended Recharger Changes Type Page ii of All Bogota SIRCI Project User Requirement Definition Table Of Contents 1. ATTENDED RECHARGER STRUCTURE .................................. 1 1.1 Outline .............................................................. 1 1.2 External/Internal structure and main module ............................ 1 1.2.1 External structure ................................................... 1 1.2.2 Main module structure I .............................................. 3 1.2.3 Internal structure .................................................... 5 1.2.4 Main module structure II .............................................. 6 2. ERROR HANDLING......................................................... 7 2.1.1 Supply the power (1/2) ............................................ 7 2.1.2 Supply the power (2/2) ............................................ 8 2.1.3 USB Trouble (1/2) ................................................. 9 2.1.4 USB Trouble (2/2) ............................................... 10 2.1.5 LCD Screen Trouble (1/2) ........................................ 11 2.1.6 LCD Screen Trouble (2/2) ........................................ 12 2.1.7 Keypad Trouble (1/2) ............................................ 13 2.1.8 Keypad Trouble (2/2) ............................................ 14 2.1.9 RTC Trouble (1/2) ............................................... 15 2.1.1 RTC Trouble (2/2) ............................................... 16 3. DEVICE MAINTENANCE ................................................... 17 3.1 CPU Board .......................................................... 17 3.1.1 Outline ......................................................... 17 3.1.2 Structure ....................................................... 17 3.1.3 Spec ............................................................ 18 3.1.4 Replacement method .............................................. 22 3.1.5 Connector Spec .................................................. 25 3.2 Customer Display ................................................... 28 3.2.1 Outline ......................................................... 28 3.2.2 Structure ....................................................... 28 3.2.3 Spec ............................................................ 29 3.2.4 Replacement method .............................................. 30 3.3 Maintenance Flow chart ............................................. 31 4. ATTENDED RECHARGER INSTALLATION AND UPDATE............................ 32 4.1 Attended recharger installation ..................................... 32 4.1.1 Process ......................................................... 32 4.1.2 Device registration ............................................. 32 CB-EDR-HM-00-V1.0 Attended Recharger Page iii of All Bogota SIRCI Project User Requirement Definition 1. Attended recharger structure 1.1 Outline Attended recharger is the device that recharges passenger’s card and managed by the crews. 1.2 External/Internal structure and main module 1.2.1 External structure 132mm (W) 185mm (H) 320mm (D) [Attended Recharger] CB-EDR-HM-00-V1.0 Attended Recharger Page1of All Bogota SIRCI Project User Requirement Definition 200mm (W) 35.6mm (D) 96mm (H) 342.6mm (H) [Customer Display] CB-EDR-HM-00-V1.0 Attended Recharger Page2of All Bogota SIRCI Project User Requirement Definition Division Contents 320mm(D) x 185mm(H) x 132mm(W) Size Material PC+ABS 1.2.2 Main module structure I 132mm(W) 1) 185mm(H) 2) 3) 4) 320mm(D) Attended Recharger Name Explanation 1) Printer Print card recharging details 2) 4.3’ LCD Display attended recharger operation 3) RFID Antenna ISO14443 Type A/B, 13.56Mhz recognition and charging 4) KEYPAD Input the amount of recharge and information CB-EDR-HM-00-V1.0 Attended Recharger Page3of All Bogota SIRCI Project User Requirement Definition Division Size Material Contents 35.6mm(D) x 96mm(H1) x 342.6mm(H2) x 200mm(W) PC+ABS 200mm(W) 35.6mm(D) 1) 2) 96mm(H1) 3) 342.6mm(H2) Customer Display Name Explanation 1) The amount before charging Display the amount before charging 2) The amount of charging Display the amount of charging 3) The amount after charging Display the amount after charging CB-EDR-HM-00-V1.0 Attended Recharger Page4of All Bogota SIRCI Project User Requirement Definition 1.2.3 Internal structure Printer Module Printer & LCD Board RFID Antenna Sub Main Board KEYPAD Board CPU Board CB-EDR-HM-00-V1.0 Attended Recharger Page5of All Bogota SIRCI Project User Requirement Definition 1.2.4 Main module structure II 1) 4.3’ LCD Display attended recharger operation 2) Printer Print various finishes, accounting journals and data etc. 3) RFID Antenna RF interface that be able to read 13.56MHz RF Card Available card : ISO 14443 Type A, B 4) CPU Board Control all part of the attended recharger and transfer processed information to the main server. CPU - S3C2440(ARM9 Core) : 400MHz Memory - SDRAM : 128MByte - Nor : 8MByte - Nand : 512Myte RF module - RC531( Type A,B) 5) Sub Board Communicate with CPU Board and control I/O devices. External PORT - Ethernet : 1EA - USB 2.0 : 1EA - External 3G Modem : 1EA - RS -232 : 3EA SAM - Socket 6EA(SIM Type) Sound - SW Codec control - Speaker : 1W * 2 EA CB-EDR-HM-00-V1.0 Attended Recharger Page6of All Bogota SIRCI Project User Requirement Definition 2. Error handling 2.1.1 Supply the power (1/2) CB-EDR-HM-00-V1.0 Attended Recharger Page7of All Bogota SIRCI Project User Requirement Definition 2.1.2 Supply the power (2/2) Check DC Jack (J2) 12V Check U5 Output 5V Check U2 Output 8V Check U3 Output 5V Check U28 Output Check U1 Output 5V 3.3V Check U4 Output 3.3V CB-EDR-HM-00-V1.0 Attended Recharger Page8of All Bogota SIRCI Project User Requirement Definition 2.1.3 USB Trouble (1/2) CB-EDR-HM-00-V1.0 Attended Recharger Page9of All Bogota SIRCI Project User Requirement Definition 2.1.4 USB Trouble (2/2) Check U21 USB HOST Controller Check USB Power Pin No.1 and 5V CB-EDR-HM-00-V1.0 Attended Recharger Page10of All Bogota SIRCI Project User Requirement Definition 2.1.5 LCD Screen Trouble (1/2) CB-EDR-HM-00-V1.0 Attended Recharger Page11of All Bogota SIRCI Project User Requirement Definition 2.1.6 LCD Screen Trouble (2/2) Check LCD Data & Power Line (Sub Main B/D) Check LCD Data & Power Line (Print B/D) Check FFC Cable Check LCD Board CB-EDR-HM-00-V1.0 Attended Recharger Check LCD Page12of All Bogota SIRCI Project User Requirement Definition 2.1.7 Keypad Trouble (1/2) CB-EDR-HM-00-V1.0 Attended Recharger Page13of All Bogota SIRCI Project User Requirement Definition 2.1.8 Keypad Trouble (2/2) Check CPU Board Key Data Line & Power Line Check Key Board Key Data Line & Power Line Check KEYPAD Cable CB-EDR-HM-00-V1.0 Attended Recharger Page14of All Bogota SIRCI Project User Requirement Definition 2.1.9 RTC Trouble (1/2) CB-EDR-HM-00-V1.0 Attended Recharger Page15of All Bogota SIRCI Project User Requirement Definition 2.1.1 RTC Trouble (2/2) Check RTC Battery Check RTC IC CB-EDR-HM-00-V1.0 Attended Recharger Page16of All Bogota SIRCI Project User Requirement Definition 3. Device maintenance 3.1 CPU Board 3.1.1 Outline Control all part of the attended recharger and transfer processed information to the main server. 3.1.2 Structure Sub Main Board Printer & LCD Board RFID Antenna KEYPAD CPU Board TOP COVER CB-EDR-HM-00-V1.0 BOTTOM COVER Attended Recharger Page17of All Bogota SIRCI Project User Requirement Definition 3.1.3 Spec 1) CPU Spec ETHERNET RC531 EXT_UART USB 2.0 NAND FLASH S3C2440 NOR FLASH SDRAM CPU Board: The core board of attended recharger and drive main program so that manage all of communication and configuration modules. CPU - S3C2440(ARM9 Core) : 400MHz Memory - SDRAM : 128MByte - Nor : 8MByte - Nand : 512Myte RF module - RC531( Type A,B) EXT_UART - SB16C1054A (SYSTEMBASE) USB 2.0 - UBI9033 (UBISYS) ETHERNET CB-EDR-HM-00-V1.0 Attended Recharger Page18of All Bogota SIRCI Project User Requirement Definition - W5100 (WIZNET) 2) SUB Board Spec Spare RS -232 Debug USB2.0 C/D Ethernet Power POWER Part RS-232 AC97 Codec SIM Slot Communicate with CPU Board and control various I/O device. External PORT - Ethernet : 1EA - USB2.0 : 1EA - External 3G Modem : 1EA - RS -232 : 3EA : C/D(Customer Display) 1, Debug 1, Spare Port 1 SAM - Socket 6EA(SIM Type) CB-EDR-HM-00-V1.0 Attended Recharger Page19of All Bogota SIRCI Project User Requirement Definition Sound - SW Codec control - Speaker : 1W * 2ea Input power - DC 12V/5A, use adopter 3) Printer & LCD Board Spec Communicate with Sub Main Board and control Printer & LCD. LCD - DC 3.3V input, GPIO communication Printer - DC 12V input, RS-232 communication CB-EDR-HM-00-V1.0 Attended Recharger Page20of All Bogota SIRCI Project User Requirement Definition 4) Antenna Board Spec Connected at CPU Board RC531, recognize the card. 5) Keypad Spec Transfer input key information to CPU Board. CB-EDR-HM-00-V1.0 Attended Recharger Page21of All Bogota SIRCI Project User Requirement Definition 3.1.4 Replacement method 1) CPU board desorption ① Separate FFC Cable that associated with Keypad and 3Pin Connector the associated with antenna board. ② Loosen the fixed bolts with Sub Board and separate Sub Board. 2) Sub Board desorption ① Remove the cable the connected to Sub Board. ② Loosen fixed five bolts with Bottom Cover and separate Bottom Cover. CB-EDR-HM-00-V1.0 Attended Recharger Page22of All Bogota SIRCI Project User Requirement Definition 3) Printer & LCD Board desorption ① Remove cable that connected to Printer & LCD Board. ② Loosen fixed four bolts with TOP Cover and separate TOP Cover. 4) Antenna Board desorption ① Remove cable that connected to Antenna Board. ② Loosen fixed two bolts TOP Cover and separate TOP Cover. CB-EDR-HM-00-V1.0 Attended Recharger Page23of All Bogota SIRCI Project User Requirement Definition 5) KEYPAD desorption ① Remove cable that connected to KETPAD. ② Loosen fixed five bolts with TOP Cover and separate TOP Cover. CB-EDR-HM-00-V1.0 Attended Recharger Page24of All Bogota SIRCI Project User Requirement Definition 3.1.5 Connector Spec A. POWER Cable CON 'A CON 'B '(SUB B/D J1) '(SWITCH) B. WHITE BLACK 1A PRINTER POWER Cable CON 'A CON 'B' '(SUB B/D J23) (PRINTER B/D CN1) CB-EDR-HM-00-V1.0 WHITE BLACK Attended Recharger Page25of All Bogota SIRCI Project User Requirement Definition C. PRINTER DATA Cable CON 'A' CON 'B' (SUB B/D J9) (PRINTER B/D CN3) TX RX GND DTR DECO D. Antenna Cable CON 'A' (CPU B/D J23) CB-EDR-HM-00-V1.0 MATCH CON 'B' (ANTENNA B/D CN1) RED WHITE GND Attended Recharger Page26of All Bogota SIRCI Project E. User Requirement Definition Customer Display CON 'B' CON 'A' (CUSTOM DISPALY (SUB B/D J8) CB-EDR-HM-00-V1.0 B/D J103) VCC VCC TX GND VCC GND RX GND Attended Recharger Page27of All Bogota SIRCI Project User Requirement Definition 3.2 Customer Display 3.2.1 Outline Communicate with the attended recharger, display the amount before recharging, the amounting of recharging, the amount after recharging. 3.2.2 Structure Customer Display Stand CB-EDR-HM-00-V1.0 Attended Recharger Page28of All Bogota SIRCI Project User Requirement Definition 3.2.3 Spec 1) Customer Display Spec FND FND control Power CPU Customer Display communicate with Attended Recharger, display the amount before recharging, the amount of recharging, the amount after recharging. CPU - ATMEGA64A Power - Attended Recharger supply DC 12V Communication - RS – 232 CB-EDR-HM-00-V1.0 Attended Recharger Page29of All Bogota SIRCI Project User Requirement Definition 3.2.4 Replacement method 1) Customer Display
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 44 Producer : ePapyrus PDF-Pro 4 Free Create Date : 2012:04:02 17:46:05 Modify Date : 2012:04:02 17:46:05 Title : Microsoft Word - WIDTHBMYMPHY Creator : ePapyrus PDF-Pro 4 Free Author :EXIF Metadata provided by EXIF.tools