SafezoneXID-500 Instruction Guide
Ver 0.3
Safety Instructions
 The Following instructions ensure your safety and prevent any damage. Be sure to read the
following instructions and use the product correctly
① Do not install the terminal in a place affected by direct sunlight, humidity, dust or soot.
② Keep the terminal away from magnets or anything containing magnetic material such as CRT, TV sets,
computer monitors and speaker.
③ Keep the terminal away from heating products.
④ Do not put in water even though product have the IP-65 test certification.
⑤ Do not drop the terminal or subject it to heavy impact
⑥ Do not apply heavy pressure to the touch screen.
⑦ Do not disassemble, repair or reconstruct the terminal.
⑧ Do not use the terminal for any other purpose than original use.
⑨ In cases of product malfunction or problems, please contact a provider
⑩ Keep the product out of reach from people without authority
1. Port
1. Port
① LAN Port (for RJ-45)
② DIP S/W
-R232 : Connect 2-3 and 5-6 with shunt
-WIEGAND : Connect 1-2 and 4-5 with shunt
③ R485/RS232(WIEGAND) port
④ INPUT port
1) INPUT1 : can be used when using EXIT Button
2) INPUT2 : is indicating DOORSTATUS signal
3) INPUT3 : Optional Input
⑤ OUTPUT port
1) Electrical Lock connection
LOCK NO : NO connection
LOCK NC : NC connection
COM : COM connection
2) LOCK TR : for external Relay (optional)
⑥ Power Connection
USB단자
② DIP S/W
INPUT
LAN
①
OUTPUT POWER
+ -
③485/232
④
⑤
⑥
RS-485
(+)
RS-485
(-)
GND
RS-232
RXD
(WIEGAND)
RS-232
TXD
(WIEGAND)
INPUT1
GND
INPUT1
(+)
INPUT2
GND
INPUT2
(+)
INPUT3
GND
LOCK
NO
COM
LOCK
NC
LOCK
TR(+)
LOCK
TR(-)
INPUT3
(+)
1. 단말 포트
 Caution in connection of each port
1) Power
* SMPS or Adaptor : Installer should check the voltage level if it is 12V
* Since including Adaptor have FGND so that Installer should check FGND with Adaptor
2) RS232/WIEGAND Dip-switch install
* RS232 : Set as 2-3 and 5-6
* WIEGAND :
Set as 1-2 and 4-5
3) LOCK Control
* In case of emergency status like blackout or power failure, Operator can use NC or NO
2. Network Setting
2. 네트워크
 Notice for connecting LAN jack
- Should be check the connection of hook
- Prevent the substance in the RJ-45
- The following Icon indicates the network condition
 Link down, please check the cable connection
 Link up, physical connection is ok but need to check the setting such like IP.
 Link up and activation of data are OK.
3. EM / Deadbolt / Strike
(One-direction Installation)
One-direction Installation
3. EM / Deadbolt / Strike
※ Electrical Lock should have the sensor of
Hi-Box
AWG24 * 2C
the door status
※ Connection Set
- UTP cable 1 PCS,
AWG24*1C
( LOCK NC)
- Power Line 2P
Power GND-
AWG24*1C
( power+)
- Control Line 6P
(Including LOCK NC, LOCK COM,
AWG24*1C
( LOCK COM)
Door status 2 cores, Exit 2 cores)
AWG24 * 2C
( on/off signal )
AWG24 * 2C
( 문상태,문상태GND)
UTP
Power
GND
Door Lock
TPS Room
Power+
One-direction Installation
3. EM / Deadbolt / Strike
LAN
485
(+)
485
(-)
GND
232
RXD
232
TXD
INPT1
GND
INPT1
(+)
INPT2
GND
INPT2
(+)
INPT3
GND
INPT3
(+)
LOCK
NO
COM
GND
TPS
Room
LOCK
NC
(-)
(+)
Door Lock
(+)
LOCK
TR(+)
LOCK
TR(-)
전원
(+)
(+)
전원
(-)
(-)
One-direction Installation
3. EM / Deadbolt / Strike
[Operation Mode]
[Manager] > [Controller]
[Manager] > [LCM]
 LCM유형 : None
 Set to “단말기 해체 경보음”
 In/Out : Set on the specific purpose
 Set to “출입”
 DoorLock 설정 : Set on purpose of
Lock type
 Input#1(InsideOpen) : NO
 Input#2(Door Status) : Set on purpose
of the status door type
 Input#3(Lock Status) : None
3. EM / Deadbolt / Strike
One-direction check-point
 Abnormal LOCKing
1. In case of the operation of LOCK is reversed :
1) Confirm the setting of LCM as “RelayOut#1”
2) Check the wire connection it is LOCK NC or NO.
-ex) Fail safe type should be set as LOCK NC.
3) Check the wire connection between XID-500 LOCK port with the electric LOCK
2. In case of unlocking, even though tagging RF-CARD :
1) Check the adjust setting of LCM.
2) Be sure the power coming form Adaptor or Power source
3. In case of the Deadbolt Lock (when door is closed, Deadbolt is not operated)
1) Confirm the setting of LCM
2) Check the position of the magnetic on the sensor
3) Check the door-icon of XID-500
4) Be sure the power coming form Adaptor or Power source
3. EM / Deadbolt / Strike
 Abnormal Door status sensing
1. In case of the operation of the Door status is reversed :
: Check the wire connection and the setting of LCM is proper setting NC/NO
2. The door status is no changed :
1) Confirm the wire connection and the setting of LCM
2) Check the door-lock have sensor can check door status.
3) Even though above conditions have no problems, LOCK should be changed
3. Status change in more frequent
1) Check the wire connection
2) Change the Door-lock
One-direction check-point
4. EM / Deadbolt / Strike
(Bi-directional Installation)
Bi-directional Installation
4. EM / Deadbolt / Strike
※ Electrical Lock should have the sensor of
the door status
AWG24 * 2C
( Power+-)
※ Connection Setting
Hi-Box
AWG24 * 2C
( Power+-)
Outdoor XID-500
- UTP cable 1 PCS, Power Line 2P
AWG24*1C
( 전원+)
- Control Line 3P (RS-485 3 cores)
AWG24 * 3C
(RS485)
Indoor XID-500
AWG24*1C
( LOCK NC)
AWG24*1C
( LOCK COM)
- UTP cable 1 PCS, Power Line 2P
- Control Line 7P
Power-
(LOCK NC, LOCK COM,
Door status 2 cores, RS-485 3 cores)
AWG24 * 2C
( Door Status,
Door Status GND)
UTP
Power+
Power
GND
Door Lock
TPS
Room
Outdoor XID-500
Indoor XID-500
Bi-directional Installation – Outdoor XID
4. EM / Deadbolt / Strike
LAN
485
(+)
485
(-)
GND
232
RXD
232
TXD
INPT1
GND
INPT1
(+)
INPT2
GND
INPT2
(+)
INPT3
GND
INPT3
(+)
LOCK
NO
COM
LOCK
NC
LOCK
TR(+)
LOCK
TR(-)
전원
(+)
전원
(-)
Power Power
(+)
(-)
TPS
Room
Indoor XID
RS-485 Port
Bi-directional Installation – Indoor XID
4. EM / Deadbolt / Strike
LAN
485
(+)
485
(-)
GND
232
RXD
232
TXD
INPT1
GND
INPT1
(+)
INPT2
GND
INPT2
(+)
INPT3
GND
INPT3
(+)
LOCK
NO
COM
전원
GND
TPS
Room
Outdoor XID
RS-485 Port
LOCK
NC
Power
(-)
Power(+)
Door Lock
Power(+)
LOCK
TR(+)
LOCK
TR(-)
전원
(+)
Power
(+)
전원
(-)
Power
(-)
Bi-direction Installation
4. EM / Deadbolt / Strike
[운용]
 Set to “출입”
[기기관리] > [기기제어]
[기기관리] > [LCM]
 Set to “단말기 해체 경보음”
 LCM Type : None
 In/Out : Set on the direction purpose
 DoorLock 설정 : Set on purpose of
 Set to “RS485 In/Out”
 Make a role “Master/Slave”
Lock type
 Input#1(InsideOpen) : None
 Input#2(Door Status) : Set on purpose
of the status door type
 Input#3(Lock Status) : None
4. EM / Deadbolt / Strike
 Abnormal LOCK
1. You can check the following when the door lock is not operated
- Confirm the setting of RS485 IN/OUT
- Be sure the direction of XID-500 Indoor/Outdoor
※ Other notice will be same except above two conditions
Bi-direction notice
5. Dummy
5. DUMMY
※ Please RS232 port of XID-500 with other device in order to operate the dummy mode
Other Device
AWG24 * 2C
( DC 12V )
AWG24 * 3C
(RS232)
11. DUMMY
※ RS232/WIEGAND Header
- Check the shunt connection of 2-3 and 5-6
LAN
485
(+)
485
(-)
GND
232
RXD
232
TXD
INPT1
GND
INPT1
(+)
INPT2
GND
INPT2
(+)
INPT3
GND
INPT3
(+)
LOCK
NO
COM
LOCK
NC
LOCK
TR(+)
LOCK
TR(-)
전원
(+)
Power
(+)
GND
TPS
ROOM
232
TXD
232
RXD
전원
(-)
Power
(-)
Dummy Installation
11. DUMMY
[운용]
 Set to “Dummy”
[운용] > [Customize] > [Dummy설정]
 Dummy Type : RS232
 Select the type of message(Message, Card number)
 Confirm output mode
6. LCM Connection
6. LCM Connection
Hi-Box
※ RS485 port can connect with LCM
XID3.0 LCM
파랑
초록
검정
※ LCM Power should be seperated with XID-500
AWG24 * 2C
( DC 12V )
AWG24 * 2C
( DC 12V )
Join RS485 wire
UTP
UTP
AWG24 * 3C
( RS-485)
TPS
Room
Outdoor XID-500
Door Lock
AWG24 * 3C
( RS-485)
Indoor XID-500
6. LCM Connections
LAN
485
(+)
485
(-)
GND
232
RXD
232
TXD
INPT1
GND
INPT1
(+)
INPT2
GND
INPT2
(+)
INPT3
GND
INPT3
(+)
LOCK
NO
COM
LOCK
NC
LOCK
TR(+)
LOCK
TR(-)
전원
(+)
Power
(+)
TPS
Room
GND
TRXD- TRXD+
LCM RS485 port
전원
(-)
Power
(-)
Installation
6. LCM Connections
[운용]
 Set “운용모드” to “출입”
[기기관리] > [기기제어]
[기기관리] > [LCM]
 Set to “단말기 해체 경보음”
 LCM Type : XID3.0
 In/Out : Set on the direction purpose
 DoorLock 설정 : None
 Input#1(InsideOpen) : None
 Input#2(Door Status) : NO or NC
 Input#3(Lock Status) : None
7. Additional Relay
Additional Relay
 The method of additional Relay connection
The Relay capability should meet the
③①
⑤④
minimum requirements of 12V/5A
Left image is showing 2 poles and 8 pins
To operate NC1 or NO1, connect Pole1.
To operate NC2 or NO2, connect Pole2.
① 12V power for the Relay coil
② 12V Coil Gnd
⑥②
⑧ ⑦
③ Pole1
④ NO1
⑤ NC1
⑥ Pole2
⑦ NO2
⑧ NC2
XID-500 Product Specifications
Item
Card Option
Physical
Interface
XID5.0
13.56 MHz
ISO14443 A/B(MIFARE)
Size (mm)
84 X 164 X 22.8
Weight (g)
260
Communication Interface
RJ45, TCP/IP, 10/100T
RS-485
RS-232
USB (for Printer)
USB (for F/W Upgrade)
Expandable
Function
Wiegand
Output
TTL
Built-in Relay
Additional Relay Control
1 (12V External Relay)
Wireless LAN
SAM
XID-500 Product Specifications
Item
Hardware
Environment
Specification
XID5.0
CPU
536 MHz
(SAMA5D31, Cortex A5)
Memory
8 MB S-flash + 4 GB
eMMC + 256 MB RAM
LCD Display
4.3” color touch screed
Humidity
90 %
Tamper
Switch
Operating Voltage
12 VDC
Audio Output Power
1.0 W
WDT
HW(MICOM), SW
RTC Battery
Yes
Operating Temperature
-20 ~ 50 °C
Humidity
90 %
ESD
Contact : < 8 kV
Air : < 15 kV
Certification
KC, SRRC, CE
Water Proof
IP65
XID-500 Product Specifications
Item
Power
Voltage (V)
Current (mA)
Switch
Input
Relay
12
400 (Max.)
VIH (V)
12
VIL (V)
GND (Low)
Pull-up resistance (Ω)
Wiegand
Output
XID5.0
10 K
VOH (V)
VOL (V)
GND (Low)
Pull-up resistance (Ω)
4.7 K
Relay Type
Dry
Switching capacity (A)
Switching power (resistive)
Switching voltage (VDC)
2 (Max.)
60W (Max.)
220
FCC Information
This device complies with part 15 of the FCC Results. Operation is subject to the
following two conditions :
(1) This Device may not cause harmful interface, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for CLASS B digital
device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
correct the interference by one or more of the following measures:
1.1. Reorient or relocate the receiving antenna.
1.2. Increase the separation between the equipment and receiver.
1.3. Connect the equipment into an outlet on a circuit different from that to which receiver is
connected.
1.4. Consult the dealer or experienced radio/TV technician for help.
WARNING
Changes or modifications not expressly approved by the manufacturer could void the
user’s authority to operate the equipment.
IMPORTANT NOTE:
FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with a
minimum distance of 20 centimeters between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other antenna
or transmitter.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2016:06:12 03:58:24+09:00
Modify Date                     : 2017:11:22 15:14:45+09:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2017:11:22 15:14:45+09:00
Producer                        : doPDF Ver 8.1 Build 920
Format                          : application/pdf
Document ID                     : uuid:196294ae-12c0-476a-8d84-4bb2948ace0f
Instance ID                     : uuid:d98aab06-0cac-495e-abcf-bdc7569b5436
Page Count                      : 33
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RTQXID500

Navigation menu