Users Manual
SafezoneXID-500 Instruction Guide Ver 0.3 Safety Instructions The Following instructions ensure your safety and prevent any damage. Be sure to read the following instructions and use the product correctly ① Do not install the terminal in a place affected by direct sunlight, humidity, dust or soot. ② Keep the terminal away from magnets or anything containing magnetic material such as CRT, TV sets, computer monitors and speaker. ③ Keep the terminal away from heating products. ④ Do not put in water even though product have the IP-65 test certification. ⑤ Do not drop the terminal or subject it to heavy impact ⑥ Do not apply heavy pressure to the touch screen. ⑦ Do not disassemble, repair or reconstruct the terminal. ⑧ Do not use the terminal for any other purpose than original use. ⑨ In cases of product malfunction or problems, please contact a provider ⑩ Keep the product out of reach from people without authority 1. Port 1. Port ① LAN Port (for RJ-45) ② DIP S/W -R232 : Connect 2-3 and 5-6 with shunt -WIEGAND : Connect 1-2 and 4-5 with shunt ③ R485/RS232(WIEGAND) port ④ INPUT port 1) INPUT1 : can be used when using EXIT Button 2) INPUT2 : is indicating DOORSTATUS signal 3) INPUT3 : Optional Input ⑤ OUTPUT port 1) Electrical Lock connection LOCK NO : NO connection LOCK NC : NC connection COM : COM connection 2) LOCK TR : for external Relay (optional) ⑥ Power Connection USB단자 ② DIP S/W INPUT LAN ① OUTPUT POWER + - ③485/232 ④ ⑤ ⑥ RS-485 (+) RS-485 (-) GND RS-232 RXD (WIEGAND) RS-232 TXD (WIEGAND) INPUT1 GND INPUT1 (+) INPUT2 GND INPUT2 (+) INPUT3 GND LOCK NO COM LOCK NC LOCK TR(+) LOCK TR(-) INPUT3 (+) 1. 단말 포트 Caution in connection of each port 1) Power * SMPS or Adaptor : Installer should check the voltage level if it is 12V * Since including Adaptor have FGND so that Installer should check FGND with Adaptor 2) RS232/WIEGAND Dip-switch install * RS232 : Set as 2-3 and 5-6 * WIEGAND : Set as 1-2 and 4-5 3) LOCK Control * In case of emergency status like blackout or power failure, Operator can use NC or NO 2. Network Setting 2. 네트워크 Notice for connecting LAN jack - Should be check the connection of hook - Prevent the substance in the RJ-45 - The following Icon indicates the network condition Link down, please check the cable connection Link up, physical connection is ok but need to check the setting such like IP. Link up and activation of data are OK. 3. EM / Deadbolt / Strike (One-direction Installation) One-direction Installation 3. EM / Deadbolt / Strike ※ Electrical Lock should have the sensor of Hi-Box AWG24 * 2C the door status ※ Connection Set - UTP cable 1 PCS, AWG24*1C ( LOCK NC) - Power Line 2P Power GND- AWG24*1C ( power+) - Control Line 6P (Including LOCK NC, LOCK COM, AWG24*1C ( LOCK COM) Door status 2 cores, Exit 2 cores) AWG24 * 2C ( on/off signal ) AWG24 * 2C ( 문상태,문상태GND) UTP Power GND Door Lock TPS Room Power+ One-direction Installation 3. EM / Deadbolt / Strike LAN 485 (+) 485 (-) GND 232 RXD 232 TXD INPT1 GND INPT1 (+) INPT2 GND INPT2 (+) INPT3 GND INPT3 (+) LOCK NO COM GND TPS Room LOCK NC (-) (+) Door Lock (+) LOCK TR(+) LOCK TR(-) 전원 (+) (+) 전원 (-) (-) One-direction Installation 3. EM / Deadbolt / Strike [Operation Mode] [Manager] > [Controller] [Manager] > [LCM] LCM유형 : None Set to “단말기 해체 경보음” In/Out : Set on the specific purpose Set to “출입” DoorLock 설정 : Set on purpose of Lock type Input#1(InsideOpen) : NO Input#2(Door Status) : Set on purpose of the status door type Input#3(Lock Status) : None 3. EM / Deadbolt / Strike One-direction check-point Abnormal LOCKing 1. In case of the operation of LOCK is reversed : 1) Confirm the setting of LCM as “RelayOut#1” 2) Check the wire connection it is LOCK NC or NO. -ex) Fail safe type should be set as LOCK NC. 3) Check the wire connection between XID-500 LOCK port with the electric LOCK 2. In case of unlocking, even though tagging RF-CARD : 1) Check the adjust setting of LCM. 2) Be sure the power coming form Adaptor or Power source 3. In case of the Deadbolt Lock (when door is closed, Deadbolt is not operated) 1) Confirm the setting of LCM 2) Check the position of the magnetic on the sensor 3) Check the door-icon of XID-500 4) Be sure the power coming form Adaptor or Power source 3. EM / Deadbolt / Strike Abnormal Door status sensing 1. In case of the operation of the Door status is reversed : : Check the wire connection and the setting of LCM is proper setting NC/NO 2. The door status is no changed : 1) Confirm the wire connection and the setting of LCM 2) Check the door-lock have sensor can check door status. 3) Even though above conditions have no problems, LOCK should be changed 3. Status change in more frequent 1) Check the wire connection 2) Change the Door-lock One-direction check-point 4. EM / Deadbolt / Strike (Bi-directional Installation) Bi-directional Installation 4. EM / Deadbolt / Strike ※ Electrical Lock should have the sensor of the door status AWG24 * 2C ( Power+-) ※ Connection Setting Hi-Box AWG24 * 2C ( Power+-) Outdoor XID-500 - UTP cable 1 PCS, Power Line 2P AWG24*1C ( 전원+) - Control Line 3P (RS-485 3 cores) AWG24 * 3C (RS485) Indoor XID-500 AWG24*1C ( LOCK NC) AWG24*1C ( LOCK COM) - UTP cable 1 PCS, Power Line 2P - Control Line 7P Power- (LOCK NC, LOCK COM, Door status 2 cores, RS-485 3 cores) AWG24 * 2C ( Door Status, Door Status GND) UTP Power+ Power GND Door Lock TPS Room Outdoor XID-500 Indoor XID-500 Bi-directional Installation – Outdoor XID 4. EM / Deadbolt / Strike LAN 485 (+) 485 (-) GND 232 RXD 232 TXD INPT1 GND INPT1 (+) INPT2 GND INPT2 (+) INPT3 GND INPT3 (+) LOCK NO COM LOCK NC LOCK TR(+) LOCK TR(-) 전원 (+) 전원 (-) Power Power (+) (-) TPS Room Indoor XID RS-485 Port Bi-directional Installation – Indoor XID 4. EM / Deadbolt / Strike LAN 485 (+) 485 (-) GND 232 RXD 232 TXD INPT1 GND INPT1 (+) INPT2 GND INPT2 (+) INPT3 GND INPT3 (+) LOCK NO COM 전원 GND TPS Room Outdoor XID RS-485 Port LOCK NC Power (-) Power(+) Door Lock Power(+) LOCK TR(+) LOCK TR(-) 전원 (+) Power (+) 전원 (-) Power (-) Bi-direction Installation 4. EM / Deadbolt / Strike [운용] Set to “출입” [기기관리] > [기기제어] [기기관리] > [LCM] Set to “단말기 해체 경보음” LCM Type : None In/Out : Set on the direction purpose DoorLock 설정 : Set on purpose of Set to “RS485 In/Out” Make a role “Master/Slave” Lock type Input#1(InsideOpen) : None Input#2(Door Status) : Set on purpose of the status door type Input#3(Lock Status) : None 4. EM / Deadbolt / Strike Abnormal LOCK 1. You can check the following when the door lock is not operated - Confirm the setting of RS485 IN/OUT - Be sure the direction of XID-500 Indoor/Outdoor ※ Other notice will be same except above two conditions Bi-direction notice 5. Dummy 5. DUMMY ※ Please RS232 port of XID-500 with other device in order to operate the dummy mode Other Device AWG24 * 2C ( DC 12V ) AWG24 * 3C (RS232) 11. DUMMY ※ RS232/WIEGAND Header - Check the shunt connection of 2-3 and 5-6 LAN 485 (+) 485 (-) GND 232 RXD 232 TXD INPT1 GND INPT1 (+) INPT2 GND INPT2 (+) INPT3 GND INPT3 (+) LOCK NO COM LOCK NC LOCK TR(+) LOCK TR(-) 전원 (+) Power (+) GND TPS ROOM 232 TXD 232 RXD 전원 (-) Power (-) Dummy Installation 11. DUMMY [운용] Set to “Dummy” [운용] > [Customize] > [Dummy설정] Dummy Type : RS232 Select the type of message(Message, Card number) Confirm output mode 6. LCM Connection 6. LCM Connection Hi-Box ※ RS485 port can connect with LCM XID3.0 LCM 파랑 초록 검정 ※ LCM Power should be seperated with XID-500 AWG24 * 2C ( DC 12V ) AWG24 * 2C ( DC 12V ) Join RS485 wire UTP UTP AWG24 * 3C ( RS-485) TPS Room Outdoor XID-500 Door Lock AWG24 * 3C ( RS-485) Indoor XID-500 6. LCM Connections LAN 485 (+) 485 (-) GND 232 RXD 232 TXD INPT1 GND INPT1 (+) INPT2 GND INPT2 (+) INPT3 GND INPT3 (+) LOCK NO COM LOCK NC LOCK TR(+) LOCK TR(-) 전원 (+) Power (+) TPS Room GND TRXD- TRXD+ LCM RS485 port 전원 (-) Power (-) Installation 6. LCM Connections [운용] Set “운용모드” to “출입” [기기관리] > [기기제어] [기기관리] > [LCM] Set to “단말기 해체 경보음” LCM Type : XID3.0 In/Out : Set on the direction purpose DoorLock 설정 : None Input#1(InsideOpen) : None Input#2(Door Status) : NO or NC Input#3(Lock Status) : None 7. Additional Relay Additional Relay The method of additional Relay connection The Relay capability should meet the ③① ⑤④ minimum requirements of 12V/5A Left image is showing 2 poles and 8 pins To operate NC1 or NO1, connect Pole1. To operate NC2 or NO2, connect Pole2. ① 12V power for the Relay coil ② 12V Coil Gnd ⑥② ⑧ ⑦ ③ Pole1 ④ NO1 ⑤ NC1 ⑥ Pole2 ⑦ NO2 ⑧ NC2 XID-500 Product Specifications Item Card Option Physical Interface XID5.0 13.56 MHz ISO14443 A/B(MIFARE) Size (mm) 84 X 164 X 22.8 Weight (g) 260 Communication Interface RJ45, TCP/IP, 10/100T RS-485 RS-232 USB (for Printer) USB (for F/W Upgrade) Expandable Function Wiegand Output TTL Built-in Relay Additional Relay Control 1 (12V External Relay) Wireless LAN SAM XID-500 Product Specifications Item Hardware Environment Specification XID5.0 CPU 536 MHz (SAMA5D31, Cortex A5) Memory 8 MB S-flash + 4 GB eMMC + 256 MB RAM LCD Display 4.3” color touch screed Humidity 90 % Tamper Switch Operating Voltage 12 VDC Audio Output Power 1.0 W WDT HW(MICOM), SW RTC Battery Yes Operating Temperature -20 ~ 50 °C Humidity 90 % ESD Contact : < 8 kV Air : < 15 kV Certification KC, SRRC, CE Water Proof IP65 XID-500 Product Specifications Item Power Voltage (V) Current (mA) Switch Input Relay 12 400 (Max.) VIH (V) 12 VIL (V) GND (Low) Pull-up resistance (Ω) Wiegand Output XID5.0 10 K VOH (V) VOL (V) GND (Low) Pull-up resistance (Ω) 4.7 K Relay Type Dry Switching capacity (A) Switching power (resistive) Switching voltage (VDC) 2 (Max.) 60W (Max.) 220 FCC Information This device complies with part 15 of the FCC Results. Operation is subject to the following two conditions : (1) This Device may not cause harmful interface, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures: 1.1. Reorient or relocate the receiving antenna. 1.2. Increase the separation between the equipment and receiver. 1.3. Connect the equipment into an outlet on a circuit different from that to which receiver is connected. 1.4. Consult the dealer or experienced radio/TV technician for help. WARNING Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2016:06:12 03:58:24+09:00 Modify Date : 2017:11:22 15:14:45+09:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2017:11:22 15:14:45+09:00 Producer : doPDF Ver 8.1 Build 920 Format : application/pdf Document ID : uuid:196294ae-12c0-476a-8d84-4bb2948ace0f Instance ID : uuid:d98aab06-0cac-495e-abcf-bdc7569b5436 Page Count : 33EXIF Metadata provided by EXIF.tools