LG Electronics USA ZA-P20 ZigBee Adapter User Manual

LG Electronics USA ZigBee Adapter Users Manual

Users Manual

 Written Date 2011-03-24 Doc No  Version 1.0 Writer Do Geun Chang Examination  Approval Bang Jun Wan Doc Manager Subject ZA-P20 RF TEST MANUAL Doc Class Test Manual  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)       ZigBee Adaptor(ZA-P20)   Subject: Test Manual
 2011-03-24  RF Test Manual Ver 1.0  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)  .   1 Operation Method  1. Connect DUT and Power Supply, and Turn on PC. 1) Connect Sample’ s RS232C Port and PC’ s RS232C Port with RS232 serial Cable. 2) DUT’ s Power and GND Line at Power Supply(+12V), and Turn on Switch.  2. DUT and PC serial communication setting    2.1 Hyper Terminal setting             BIT/Sec(B) : 115200               DATA BIT(D) : 8          PARITY(P) : NONE          STOP BIT(S) : 1          FLOW CONTROL : NONE  Primary Value  Change Value
 2011-03-24  RF Test Manual Ver 1.0  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)  3. TEST COMMAND 3.1 settxpowmode l p –  POWER Mode Setting Command 1) Operation Method   > Command Setting Mode 2) Setting Mode  I p 0 0: Normal-mode, PA-internal 0 1: Normal-mode, PA-External 1 0: Boost-mode, PA-internal 1 1: Boost-mode, PA-External 3) Execution Scene   3.2 settxpower p –  Output Power Setting Command  1) Operation Method   > Command Setting Mode 2) Power Range : +8 ~ -32   3) Execution Scene
 2011-03-24  RF Test Manual Ver 1.0  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)  3.3 setchannel c –  Channel setting Command 1) Operation Method    > Command Setting Mode (Range: 0x0B ~ 0x1A )      > Channel 0x0B -> Change the 0x0B channel, Channel value must be hexadecimal.  2) Channel Table Channel 0x0B  2405 MHz Channel 0x0C  2410 MHz Channel 0x0D  2415 MHz Channel 0x0E  2420 MHz Channel 0x0F  2425 MHz Channel 0x10  2430 MHz Channel 0x11  2435 MHz Channel 0x12  2440 MHz Channel 0x13  2445 MHz Channel 0x14  2450 MHz Channel 0x15  2455 MHz Channel 0x16  2460 MHz Channel 0x17  2465 MHz Channel 0x18  2470 MHz Channel 0x19  2475 MHz Channel 0x1A  2480 MHz                3) Execution Scene
 2011-03-24  RF Test Manual Ver 1.0  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)  3.3 txtone –  Un-modulated Singnal Command 1) Operation Method   > Command Setting Mode  > txtone  Transmitting    Carrier frequency. Press 'e'xit to stop 2) txtone (Unmodulated Singnal) TEST A. settxpowmode 0 1          B. settxpower 0         C. setchannel 0x0B (see the Channel Table)  D. txtone    Command Execution  3) Execution Scene
 2011-03-24  RF Test Manual Ver 1.0  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)  3.4 txstream –  Modulated signal’ s Maximum rate transmission mode 1) Operation Method   > Command Setting Mode  > txstream    'e'nd... 2) txstream(Modulated Signal) TEST A. settxpowmode 0 1          B. settxpower 0       C. setchannel 0x0B (see the Channel Table)  D. txstream    Command Execution  3) Execution Scene
 2011-03-24  RF Test Manual Ver 1.0  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)  3.5 rx – rx mode 1) Operation Method   > Command Setting Mode  > rx  Entering RX mode, press c to reset, press e to exit 2) rx TEST A. settxpowmode 0 1          B. settxpower 0         C. setchannel 0x0B (see the Channel Table)  D. rx Command Execution  3) Execution Scene
 2011-03-24  RF Test Manual Ver 1.0  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)  4. RF TEST    Method 4.1 un-modulated CW Signal Test  1)    Command input for un-modulated signal test(txtone)   A. settxpowmode 0 1         B. settxpower 0        C. setchannel    0x0B (see the Channel Table)  D. txtone Command Execution  2) Execution Scene
 2011-03-24  RF Test Manual Ver 1.0  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)  4.2 Modulated Signal Test  1)    Command input for TEST (txstream)     A. settxpowmode 0 1          B. settxpower 0      C. setchannel    0x0B (see the Channel Table)  D. txstream Command Execution  2) Execution Scene
 2011-03-24  RF Test Manual Ver 1.0  KQF-0705-1(0)                                                        LG Electronics Inc.                                                        A4(210X297)  4.3 rx Mode Setting 1) Command input for receive TEST   A. settxpowmode 0 1          B. settxpower 0        C. setchannel    0x0B (see the Channel Table)  D. rx    Command execution  2) Execution Scene   This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may notcause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.         This equipment complies with FCC radiation exposure limits set forth for an uncontrolledenvironment.     This equipment should be installed and operated with minimum 20 cmbetween the radiator and your      body.