LG Electronics USA ZA-P20 ZigBee Adapter User Manual

LG Electronics USA ZigBee Adapter Users Manual

Users Manual

Download: LG Electronics USA ZA-P20 ZigBee Adapter User Manual
Mirror Download [FCC.gov]LG Electronics USA ZA-P20 ZigBee Adapter User Manual
Document ID1488360
Application IDyK1Gn1BwUWzhi+PSH4qxBw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize52.18kB (652293 bits)
Date Submitted2011-06-22 00:00:00
Date Available2011-08-06 00:00:00
Creation Date2011-06-21 22:39:39
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2011-06-21 22:44:19
Document TitleUsers Manual
Document CreatorWordìš© Acrobat PDFMaker 9.0
Document Author: 박희구

Written Date
2011-03-24
Examination
Writer
Do Geun Chang
Subject
ZA-P20 RF TEST MANUAL
Doc No
Approval
Bang Jun Wan
Doc Class
Test Manual
Version
1.0
Doc Manager
ZigBee Adaptor(ZA-P20)
Subject: Test Manual
KQF-0705-1(0)
LG Electronics Inc.
A4(210X297)
2011-03-24
RF Test Manual
Ver
1.0
1 Operation Method
1. Connect DUT and Power Supply, and Turn on PC.
1) Connect Sample’ s RS232C Port and PC’ s RS232C Port with RS232 serial Cable.
2) DUT’ s Power and GND Line at Power Supply(+12V), and Turn on Switch.
2. DUT and PC serial communication setting
2.1 Hyper Terminal setting
BIT/Sec(B) : 115200
DATA BIT(D) : 8
PARITY(P) : NONE
STOP BIT(S) : 1
FLOW CONTROL : NONE
Primary Value
KQF-0705-1(0)
Change Value
LG Electronics Inc.
A4(210X297)
2011-03-24
RF Test Manual
Ver
1.0
3. TEST COMMAND
3.1 settxpowmode l p – POWER Mode Setting Command
1) Operation Method
> Command Setting Mode
2) Setting Mode
I p 0 0: Normal-mode, PA-internal
0 1: Normal-mode, PA-External
1 0: Boost-mode, PA-internal
1 1: Boost-mode, PA-External
3) Execution Scene
3.2 settxpower p – Output Power Setting Command
1) Operation Method
> Command Setting Mode
2) Power Range : +8 ~ -32
3) Execution Scene
KQF-0705-1(0)
LG Electronics Inc.
A4(210X297)
2011-03-24
RF Test Manual
Ver
1.0
3.3 setchannel c – Channel setting Command
1) Operation Method
> Command Setting Mode (Range: 0x0B ~ 0x1A )
> Channel 0x0B -> Change the 0x0B channel, Channel value must be hexadecimal.
2) Channel Table
Channel 0x0B
Channel 0x0C
Channel 0x0D
Channel 0x0E
Channel 0x0F
Channel 0x10
Channel 0x11
Channel 0x12
Channel 0x13
Channel 0x14
Channel 0x15
Channel 0x16
Channel 0x17
Channel 0x18
Channel 0x19
Channel 0x1A
2405
2410
2415
2420
2425
2430
2435
2440
2445
2450
2455
2460
2465
2470
2475
2480
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
3) Execution Scene
KQF-0705-1(0)
LG Electronics Inc.
A4(210X297)
2011-03-24
RF Test Manual
Ver
1.0
3.3 txtone – Un-modulated Singnal Command
1) Operation Method
> Command Setting Mode
> txtone
Transmitting Carrier frequency. Press 'e'xit to stop
2) txtone (Unmodulated Singnal) TEST
A. settxpowmode 0 1
B. settxpower 0
C. setchannel 0x0B (see the Channel Table)
D. txtone Command Execution
3) Execution Scene
KQF-0705-1(0)
LG Electronics Inc.
A4(210X297)
2011-03-24
RF Test Manual
Ver
1.0
3.4 txstream – Modulated signal’ s Maximum rate transmission mode
1) Operation Method
> Command Setting Mode
> txstream
'e'nd...
2) txstream(Modulated Signal) TEST
A. settxpowmode 0 1
B. settxpower 0
C. setchannel 0x0B (see the Channel Table)
D. txstream Command Execution
3) Execution Scene
KQF-0705-1(0)
LG Electronics Inc.
A4(210X297)
2011-03-24
RF Test Manual
Ver
1.0
3.5 rx – rx mode
1) Operation Method
> Command Setting Mode
> rx
Entering RX mode, press c to reset, press e to exit
2) rx TEST
A. settxpowmode 0 1
B. settxpower 0
C. setchannel 0x0B (see the Channel Table)
D. rx Command Execution
3) Execution Scene
KQF-0705-1(0)
LG Electronics Inc.
A4(210X297)
2011-03-24
RF Test Manual
Ver
1.0
4. RF TEST Method
4.1 un-modulated CW Signal Test
1) Command input for un-modulated signal test(txtone)
A. settxpowmode 0 1
B. settxpower 0
C. setchannel
0x0B (see the Channel Table)
D. txtone Command Execution
2) Execution Scene
KQF-0705-1(0)
LG Electronics Inc.
A4(210X297)
2011-03-24
RF Test Manual
Ver
1.0
4.2 Modulated Signal Test
1) Command input for TEST (txstream)
A. settxpowmode 0 1
B. settxpower 0
C. setchannel
0x0B (see the Channel Table)
D. txstream Command Execution
2) Execution Scene
KQF-0705-1(0)
LG Electronics Inc.
A4(210X297)
2011-03-24
RF Test Manual
Ver
1.0
4.3 rx Mode Setting
1) Command input for receive TEST
A. settxpowmode 0 1
B. settxpower 0
C. setchannel
D. rx
0x0B (see the Channel Table)
Command execution
2) Execution Scene
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by
manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may notcause harmful interference, and (2) this
device must accept any interference received, including interference that may
cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolledenvironment.
This equipment should be installed and operated with minimum 20 cmbetween the radiator and your
body.
KQF-0705-1(0)
LG Electronics Inc.
A4(210X297)

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : 박희구
Company                         : (주)한국인포콤
Create Date                     : 2011:06:21 22:39:39+09:00
Modify Date                     : 2011:06:21 22:44:19+09:00
Source Modified                 : D:20110324071232
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    :  Word용 Acrobat PDFMaker 9.0
Metadata Date                   : 2011:06:21 22:44:19+09:00
Format                          : application/pdf
Creator                         : 박희구
Title                           : 기술사양서
Document ID                     : uuid:f278e181-041f-4fff-b5e1-56d0823079ea
Instance ID                     : uuid:0e443b57-c89d-451d-8ff9-6e822d2bd867
Subject                         : 5
Page Layout                     : OneColumn
Page Count                      : 10
EXIF Metadata provided by EXIF.tools
FCC ID Filing: BEJ-ZA-P20

Navigation menu