             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 1 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS   RATE$AVER In Home Display  Features • BATTERY OPERATED ! • Zero Power Display • Smart Energy Profile Approved1 • Current Use / Rate / Tier Display • Messaging / Alarm Display • Graphical Cost and Usage Summary • Time-of-Use Display • Date / Time / Temperature • Unlimited View Angle • 100 mW Zigbee Radio • FCC / CE / IC Certified (pending)2 • Simple User Interface • Internal Buzzer / Alarm • Optional USB Power / PC Programming Interface • Internal Magnet – Refrigerator Mount                                                     1 Pending 2 Pending Product Description  The Rate$aver is an In-Home-Display (IHD) device capable of communicating with Smart Energy Profile compliant Energy Service Portals (ESP) within electric meters to display current energy consumption, utility rates, billing history, messages, alarms, temperature and time.  The device consists of display technology requiring no power consumption to display graphical images enabling true, wireless battery operation.  The device operates on 2 AA batteries and incorporates a 100 mW high performance Zigbee radio.  Ordering Information:  Part Number  RS-SE-24-01
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 2 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS    1) Display   • 128 x 64 Pixel • Blue / White Monochrome • Zero Power / Persistent Display  2) Buttons • Scroll • Select / Enter   • Menu • $ • kW-h usage • Messages  3) Beeper • Beep Tone #1: on button press – user option to disable • Beep Tone #2: on alarm or new high priority unsolicited message – user option to disable • Volume – tone #1 low, tone #2 high • Frequency: tone #1 = 500 Hz; tone #2 = 2 kHz • Duration o Tone #1: 100ms o Tone #2: 500ms 4) Temperature Sensor • Internal Temperature Sensor (Indoor Ambient Temperature Displayed) • Range: same as product operating temperature range • Accuracy: +/- 2 ⁰C over specified range, +/-1 ⁰C at 25 ⁰C  5) Wireless Protocol • Conforms to Zigbee Smart Energy Profile for In Home Display device • Supports all mandatory attributes and commands plus additional ones required for the specified screens from the following clusters: o Simple Metering o Price o Message o Time o Key Establishment o Identify o Basic
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 3 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS  6) Supported Zigbee Cluster attributes and commands: CLUSTER Attributes  (provided by RateSaver if a server cluster, required from ESP if a client cluster) Commands Accepted  Commands Generated       Basic Server  ZCL version Application Version Stack Version HW Version Manufacturers Name Model Identifier Date Code Power Source Reset to Factory Defaults  Identify Server  Identify Time  Identify Identify Query Identify Query Response Key Establishment Client    Key Establishment Server    Time Client  Time Time Status Local Time   Simple Meter Client  Current Summation Delivered Current Tier 1 Summation Del Current Tier 2 Summation Del Current Tier 3 Summation Del Current Tier 4 Summation Del Current Tier 5 Summation Del Current Tier 6 Summation Del  Summation Formatting  Instantaneous Demand  Unit of Measure Metering Device Type  Status (Service Disconnect, Leak detect, Power Qual, Power Fail, Tamper Detect, Low Battery, Check Meter)  Others TBD   Price Client    Publish Price  Get Current Price Get Scheduled Prices Message Client    Display Message Cancel Message Get Last Message Message Confirmation       Manufacturer Specific Client tbd    • Mandatory features o Join network, pair devices (ZDP bind and unbind), end device announce o Factory defaults restore
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 4 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS  o Enable Identify Mode by user o Service Discovery (Match descriptor request)  7) Enclosure • Dimensions o 100mm x 64mm x 26mm • ABS Plastic • Non-glare Lens • Integrated Magnet for mounting • Front Panel Label: customizable Mylar graphical overlay  8) Power supply • Power Source o 2 AA alkaline batteries  o USB connector power • External Connector (for firmware upgrade) o USB Mini-B Receptacle • Battery Life:  1 year with 60 second update interval • Reverse Battery Protection  9)  Test and Programming Interface • Firmware Updates: UART interface via mini-B USB connector. External adapter required to convert USB/RS232 to UART level signals (provided by LSR). • Test & Debug: via JTAG Interface with access points in battery compartment. Supports both DIP and ZIF connector interface cables (provided by LSR).  10)  Screens • Screens included as needed for particular customers.  Examples include: o Current tier, current tier rate, total consumption, total monthly bill, standard header o   o  o Tier breakdown screen: for each tier –horizontal bar graphs or numeric table
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 5 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS       o  o User Messaging Screen / Alarm Display – inverted colors-.   o Inst power screen – numeric kWatts and bar   o User Setup and Initialization  Network ID and Channel  Join Network button  Celsius/Fahrenheit  Time Zone o Low Power:  Screen Display “Replace Battery” • Screen Operation o Cycle through info screens on SCROLL button press o Poll and refresh current screen on any button press o Go to setup screen on SELECT / MENU button held for 5 seconds. o Automatically switch to message screen when new message received.  11)  Information present on all screens (header) • Date / Time Display o Poll ESP no more than once per 24 hours (per SE spec) o Accuracy within +/-1minute relative to ESP (per SE spec) • Battery/Power Indicator o V>= 2.0v no battery indication o 1.6v <V<2.0v  low battery icon- broken battery o V< 1.6v unit shut down. hollow broken battery icon, no link icon, unit off screen “Replace Battery” • Indoor temperature o ⁰C/⁰F user selectable • Wireless link indicator o Cell phone standard 4 bar antenna signal strength graphic  12)  Commissioning
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 6 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS  • user informs network owner (web login, phone call, handheld tool) provide MAC ID and mfg supplied hashed key  Utility commissions ESP to allow join for limited time • User / Installer press button/sequence to initiate join  • Device indicates to user “joined”   13)  Polling • Poll ESP for updated information needed for current screen: o Immediately on screen change or refresh button press  Indicate “updating” immediately  Draw whole new screen after new info arrives, or timeout o Every 60 seconds on the minute o Only changed portions of screen redraw  14)  Firmware upgrades • Wired Bootloader – through USB connector • Wireless Bootloader – must be implemented in ESP or parent router to the display.  Requires code to initiate the bootloader in the display and transfer the code image.  Also method to read/supply the code image file.  LSR to supply example source code and specifications.  15)  Regulatory Requirements (pending) • FCC part 15.247, 15.209 • Industry Canada RSS 210 • CE EN 300 220 1 • C-Tick • Zigbee SE Profile Certification • RoHS Compliant  16)  Environmental • Operating temperature o 10deg C to 70deg C • Storage temperature o -20deg C to 100deg C • Relative Humidity – non-condensing o <90% for T<40C, <50% T>40C • Physical shock  (consumer level drop test) o Test per IEC 60068-2-27 (Shock) o 20g peak acceleration in three orthogonal axis o Saw tooth pulse shape, 11ms pulse width • Vibration o Test per IEC 60068-2-6 (Sinusoidal Vibration)
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 7 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS  o 5g-peak acceleration o 10-150 Hz o Five cycles per axis in three orthogonal axis • ESD o Per CE approval limits specified in ETS 301-489 and EN 61000-4-2 testing methods
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 8 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS  Absolute Maximum Ratings  Rating Value Unit Power Supply Voltage Input  3.5  Vdc Voltage on any digital pin  Max 3.6  Vdc RF Input Power  +10  dBm Storage Temperature Range -45 to 125  ºC Note: Under no circumstances exceeding the maximum ratings in Table can be allowed.  Such a stress may cause permanent damage to the devices     Operating Conditions  Characteristic Min Typ Max Unit Power Supply Voltage (Vdd)  2.1    3.5  V Input Frequency  2405  2480 MHz Ambient Temperature Range 10 25 70  ºC Logic Input Low Voltage  0    0.7  V Logic Input High Voltage  2.8    3.6  V  Radio Electrical Specifications At 25ºC, Vdd = 3.3V for both APEX and APEX LT unless stated otherwise.    General  Parameter Min Typ Max Unit RF Frequency Range  2400  2483.5 MHz RF Data Rate    250  kbps Microcontroller Operating Frequency   12   MHz Flash Memory     128  kB RAM     5    kB   Power Consumption Parameter Min Typ Max Unit Transmit Mode (100mW output)      Receive Mode         Standby Mode                   Boost mode is an optional higher performance radio mode that is software selectable to boost receiver sensitivity.  Transmitter Parameter Min Typ Max Unit Nominal Output Power     20    dBm
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 9 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS  Programmable Output Power range  32   dB Error Vector Magnitude    15  35  %          Receiver Parameter Min Typ Max Unit Receiver Sensitivity (1% PER) – normal mode -92 -96   dBm Receiver Sensitivity (1% PER) – boost mode  -93  -97    dBm Saturation (Maximum Input Level) (1% PER)  0      dBm 802.15.4 Adjacent Channel Rejection         APEX 35     dB       802.15.4 Alternate Channel Rejection  40      dB 802.11g Rejection (±10 MHz)         APEX 40     dB         Control DC characteristics Parameter Min Typ Max Unit Logic Input Low  0    0.2VDD  V Logic Input High  0.8VDD    VDD  V Logic Output Low  0    0.18VDD  V Logic Output High  0.82VDD  VDD  V Output source current       4  mA Output sink current       4  mA Output source current       8  mA Output sink current       8  mA I/O pin pull-up and pull-down resistor  30  kΩ                                Figure 1
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 10 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS    Mechanical Drawing
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 11 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS     Disclaimer LS Research, LLC believes the information in this document is correct and accurate at the time of release.  However, LS Research, LLC reserves the right to make changes to this product without notice.   Statements  Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules.  Operation is subject to the following two conditions:  1.   This device may not cause harmful interference, and  2.   This device must accept any interference received,         including interference that may cause undesired operation.  Warning (Part 15.21) Changes or modifications not expressly approved by the party  responsible for compliance could void the user’s authority to  operate the equipment.  FCC Interference Statement (Part 15.105 (b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:   - Reorient or relocate the receiving antenna.   - Increase the separation between the equipment and receiver.   - Connect the equipment into an outlet on a circuit different from that        to which the receiver is connected.   - Consult the dealer or an experienced radio/TV technician for help.
             LS RESEARCH       WIRELESS PRODUCT DEVELOPMENT                                                     Rate$aver IHD 12 | Page  Rate$aver Datasheet (rev. 1.0)  LSR -DS  RF Exposure (OET Bulletin 65) To comply with FCC’s and IC’s  RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.   Section 7.1.5 of RSS-GEN Operation is subject to the following two conditions:  1) This device may not cause harmful interference, and 2) This device must accept any interference received,  including interference that may cause undesired operation.

Navigation menu