Laird Connectivity RATESAVER Wireless Electric Meter Monitor User Manual Manual
LS Research, LLC Wireless Electric Meter Monitor Manual
Manual
LS RESEARCH Rate$aver IHD WIRELESS PRODUCT DEVELOPMENT RATE$AVER In Home Display Features • • • • • • • • • • • • • • • BATTERY OPERATED ! Zero Power Display Smart Energy Profile Approved1 Current Use / Rate / Tier Display Messaging / Alarm Display Graphical Cost and Usage Summary Time-of-Use Display Date / Time / Temperature Unlimited View Angle 100 mW Zigbee Radio FCC / CE / IC Certified (pending)2 Simple User Interface Internal Buzzer / Alarm Optional USB Power / PC Programming Interface Internal Magnet – Refrigerator Mount Ordering Information: Part Number RS-SE-24-01 Product Description The Rate$aver is an In-Home-Display (IHD) device capable of communicating with Smart Energy Profile compliant Energy Service Portals (ESP) within electric meters to display current energy consumption, utility rates, billing history, messages, alarms, temperature and time. The device consists of display technology requiring no power consumption to display graphical images enabling true, wireless battery operation. The device operates on 2 AA batteries and incorporates a 100 mW high performance Zigbee radio. Pending Pending 1|Page Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH WIRELESS PRODUCT DEVELOPMENT Rate$aver IHD 1) Display • 128 x 64 Pixel • Blue / White Monochrome • Zero Power / Persistent Display 2) Buttons • • • • • • Scroll Select / Enter Menu kW-h usage Messages 3) Beeper • • • • • Beep Tone #1: on button press – user option to disable Beep Tone #2: on alarm or new high priority unsolicited message – user option to disable Volume – tone #1 low, tone #2 high Frequency: tone #1 = 500 Hz; tone #2 = 2 kHz Duration o Tone #1: 100ms o Tone #2: 500ms 4) Temperature Sensor • • • Internal Temperature Sensor (Indoor Ambient Temperature Displayed) Range: same as product operating temperature range Accuracy: +/- 2 ⁰C over specified range, +/-1 ⁰C at 25 ⁰C 5) Wireless Protocol • • 2|Page Conforms to Zigbee Smart Energy Profile for In Home Display device Supports all mandatory attributes and commands plus additional ones required for the specified screens from the following clusters: o Simple Metering o Price o Message o Time o Key Establishment o Identify o Basic Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH Rate$aver IHD WIRELESS PRODUCT DEVELOPMENT 6) Supported Zigbee Cluster attributes and commands: CLUSTER Attributes (provided by RateSaver if a server cluster, required from ESP if a client cluster) Commands Accepted Basic Server ZCL version Application Version Stack Version HW Version Manufacturers Name Model Identifier Date Code Power Source Identify Time Reset to Factory Defaults Identify Server Commands Generated Identify Identify Query Identify Query Response Price Client Publish Price Message Client Display Message Cancel Message Get Current Price Get Scheduled Prices Get Last Message Message Confirmation Key Establishment Client Key Establishment Server Time Client Simple Meter Client Time Time Status Local Time Current Summation Delivered Current Tier 1 Summation Del Current Tier 2 Summation Del Current Tier 3 Summation Del Current Tier 4 Summation Del Current Tier 5 Summation Del Current Tier 6 Summation Del Summation Formatting Instantaneous Demand Unit of Measure Metering Device Type Status (Service Disconnect, Leak detect, Power Qual, Power Fail, Tamper Detect, Low Battery, Check Meter) Others TBD Manufacturer Specific Client • tbd Mandatory features 3|Page Join network, pair devices (ZDP bind and unbind), end device announce Factory defaults restore Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH WIRELESS PRODUCT DEVELOPMENT Rate$aver IHD Enable Identify Mode by user Service Discovery (Match descriptor request) 7) Enclosure • • • • • Dimensions o 100mm x 64mm x 26mm ABS Plastic Non-glare Lens Integrated Magnet for mounting Front Panel Label: customizable Mylar graphical overlay 8) Power supply • • • • Power Source o 2 AA alkaline batteries o USB connector power External Connector (for firmware upgrade) o USB Mini-B Receptacle Battery Life: 1 year with 60 second update interval Reverse Battery Protection 9) Test and Programming Interface • Firmware Updates: UART interface via mini-B USB connector. External adapter required to convert USB/RS232 to UART level signals (provided by LSR). • Test & Debug: via JTAG Interface with access points in battery compartment. Supports both DIP and ZIF connector interface cables (provided by LSR). 10) Screens • Screens included as needed for particular customers. Examples include: o Current tier, current tier rate, total consumption, total monthly bill, standard header 4|Page Tier breakdown screen: for each tier –horizontal bar graphs or numeric table Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH WIRELESS PRODUCT DEVELOPMENT Rate$aver IHD User Messaging Screen / Alarm Display – inverted colors-. Inst power screen – numeric kWatts and bar User Setup and Initialization Network ID and Channel Join Network button Celsius/Fahrenheit Time Zone o Low Power: Screen Display “Replace Battery” Screen Operation o Cycle through info screens on SCROLL button press o Poll and refresh current screen on any button press o Go to setup screen on SELECT / MENU button held for 5 seconds. o Automatically switch to message screen when new message received. • 11) Information present on all screens (header) • • • • Date / Time Display o Poll ESP no more than once per 24 hours (per SE spec) o Accuracy within +/-1minute relative to ESP (per SE spec) Battery/Power Indicator o V>= 2.0v no battery indication o 1.6v40C Physical shock (consumer level drop test) o Test per IEC 60068-2-27 (Shock) o 20g peak acceleration in three orthogonal axis o Saw tooth pulse shape, 11ms pulse width Vibration o Test per IEC 60068-2-6 (Sinusoidal Vibration) Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH WIRELESS PRODUCT DEVELOPMENT • 7|Page ESD Rate$aver IHD 5g-peak acceleration 10-150 Hz Five cycles per axis in three orthogonal axis Per CE approval limits specified in ETS 301-489 and EN 61000-4-2 testing methods Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH Rate$aver IHD WIRELESS PRODUCT DEVELOPMENT Absolute Maximum Ratings Rating Power Supply Voltage Input Voltage on any digital pin RF Input Power Storage Temperature Range Value 3.5 Max 3.6 +10 -45 to 125 Unit Vdc Vdc dBm ºC Note: Under no circumstances exceeding the maximum ratings in Table can be allowed. Such a stress may cause permanent damage to the devices Operating Conditions Characteristic Min Typ Max Unit Power Supply Voltage (Vdd) 2.1 3.5 Input Frequency 2405 2480 MHz Ambient Temperature Range 10 25 70 ºC Logic Input Low Voltage 0.7 Logic Input High Voltage 2.8 3.6 Radio Electrical Specifications At 25ºC, Vdd = 3.3V for both APEX and APEX LT unless stated otherwise. General Parameter Min RF Frequency Range 2400 RF Data Rate Microcontroller Operating Frequency Flash Memory RAM Typ Max 2483.5 250 12 128 Unit MHz kbps MHz kB kB Power Consumption Parameter Min Typ Max Unit Transmit Mode (100mW output) Receive Mode Standby Mode Boost mode is an optional higher performance radio mode that is software selectable to boost receiver sensitivity. Transmitter Parameter Nominal Output Power 8|Page Min Typ Max Unit 20 dBm Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH Rate$aver IHD WIRELESS PRODUCT DEVELOPMENT Programmable Output Power range Error Vector Magnitude 32 15 35 dB Receiver Parameter Receiver Sensitivity (1% PER) – normal mode Receiver Sensitivity (1% PER) – boost mode Saturation (Maximum Input Level) (1% PER) 802.15.4 Adjacent Channel Rejection APEX Min Typ Max Unit -92 -96 dBm -93 -97 dBm dBm 35 dB 802.15.4 Alternate Channel Rejection 802.11g Rejection (±10 MHz) 40 dB APEX 40 dB Control DC characteristics Parameter Logic Input Low Logic Input High Logic Output Low Logic Output High Output source current Output sink current Output source current Output sink current I/O pin pull-up and pull-down resistor Min Typ Max 0.2VDD 0.8VDD VDD 0.18VDD 0.82VDD VDD 30 Unit mA mA mA mA kΩ Figure 1 9|Page Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH WIRELESS PRODUCT DEVELOPMENT Rate$aver IHD Mechanical Drawing 10 | P a g e Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH WIRELESS PRODUCT DEVELOPMENT Rate$aver IHD Disclaimer LS Research, LLC believes the information in this document is correct and accurate at the time of release. However, LS Research, LLC reserves the right to make changes to this product without notice. Statements Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Interference Statement (Part 15.105 (b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. 11 | P a g e Rate$aver Datasheet (rev. 1.0) LSR -DS LS RESEARCH WIRELESS PRODUCT DEVELOPMENT Rate$aver IHD RF Exposure (OET Bulletin 65) To comply with FCC’s and IC’s RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Section 7.1.5 of RSS-GEN Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. 12 | P a g e Rate$aver Datasheet (rev. 1.0) LSR -DS
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 8.1.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2008:09:05 13:42:16-05:00 Create Date : 2008:09:05 13:42:16-05:00 Format : application/pdf Title : Microsoft Word - User Manual RS-IHD-24 v1.1 REVISED 1.doc Creator : twhite Document ID : uuid:eef315a5-62d8-4e62-b54f-fd307d6c3f66 Instance ID : uuid:c0aa6287-7961-43d0-991e-d306843bf774 Page Count : 12 Author : twhiteEXIF Metadata provided by EXIF.tools