Laird Connectivity RATESAVER Wireless Electric Meter Monitor User Manual Manual

LS Research, LLC Wireless Electric Meter Monitor Manual

Manual

Download: Laird Connectivity RATESAVER Wireless Electric Meter Monitor User Manual Manual
Mirror Download [FCC.gov]Laird Connectivity RATESAVER Wireless Electric Meter Monitor User Manual Manual
Document ID996997
Application IDffjiHGbQjd38FTDmUrkf0g==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize18.59kB (232389 bits)
Date Submitted2008-09-08 00:00:00
Date Available2008-09-08 00:00:00
Creation Date2008-09-05 13:42:16
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2008-09-05 13:42:16
Document TitleMicrosoft Word - User Manual RS-IHD-24 v1.1 REVISED 1.doc
Document CreatorPScript5.dll Version 5.2
Document Author: twhite

LS RESEARCH
Rate$aver IHD
WIRELESS PRODUCT DEVELOPMENT
RATE$AVER
In Home Display
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
BATTERY OPERATED !
Zero Power Display
Smart Energy Profile Approved1
Current Use / Rate / Tier Display
Messaging / Alarm Display
Graphical Cost and Usage
Summary
Time-of-Use Display
Date / Time / Temperature
Unlimited View Angle
100 mW Zigbee Radio
FCC / CE / IC Certified
(pending)2
Simple User Interface
Internal Buzzer / Alarm
Optional USB Power / PC
Programming Interface
Internal Magnet – Refrigerator
Mount
Ordering Information:
Part Number
RS-SE-24-01
Product Description
The Rate$aver is an In-Home-Display (IHD) device capable of communicating with Smart
Energy Profile compliant Energy Service Portals (ESP) within electric meters to display
current energy consumption, utility rates, billing history, messages, alarms, temperature
and time. The device consists of display technology requiring no power consumption to
display graphical images enabling true, wireless battery operation. The device operates
on 2 AA batteries and incorporates a 100 mW high performance Zigbee radio.
Pending
Pending
1|Page
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
WIRELESS PRODUCT DEVELOPMENT
Rate$aver IHD
1) Display
• 128 x 64 Pixel
• Blue / White Monochrome
• Zero Power / Persistent Display
2) Buttons
•
•
•
•
•
•
Scroll
Select / Enter
Menu
kW-h usage
Messages
3) Beeper
•
•
•
•
•
Beep Tone #1: on button press – user option to disable
Beep Tone #2: on alarm or new high priority unsolicited message – user
option to disable
Volume – tone #1 low, tone #2 high
Frequency: tone #1 = 500 Hz; tone #2 = 2 kHz
Duration
o Tone #1: 100ms
o Tone #2: 500ms
4) Temperature Sensor
•
•
•
Internal Temperature Sensor (Indoor Ambient Temperature Displayed)
Range: same as product operating temperature range
Accuracy: +/- 2 ⁰C over specified range, +/-1 ⁰C at 25 ⁰C
5) Wireless Protocol
•
•
2|Page
Conforms to Zigbee Smart Energy Profile for In Home Display device
Supports all mandatory attributes and commands plus additional ones
required for the specified screens from the following clusters:
o Simple Metering
o Price
o Message
o Time
o Key Establishment
o Identify
o Basic
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
Rate$aver IHD
WIRELESS PRODUCT DEVELOPMENT
6) Supported Zigbee Cluster attributes and commands:
CLUSTER
Attributes
(provided by RateSaver if a
server cluster, required from ESP
if a client cluster)
Commands Accepted
Basic Server
ZCL version
Application Version
Stack Version
HW Version
Manufacturers Name
Model Identifier
Date Code
Power Source
Identify Time
Reset to Factory
Defaults
Identify Server
Commands Generated
Identify
Identify Query
Identify Query Response
Price Client
Publish Price
Message Client
Display Message
Cancel Message
Get Current Price
Get Scheduled Prices
Get Last Message
Message Confirmation
Key Establishment
Client
Key Establishment
Server
Time Client
Simple Meter Client
Time
Time Status
Local Time
Current Summation Delivered
Current Tier 1 Summation Del
Current Tier 2 Summation Del
Current Tier 3 Summation Del
Current Tier 4 Summation Del
Current Tier 5 Summation Del
Current Tier 6 Summation Del
Summation Formatting
Instantaneous Demand
Unit of Measure
Metering Device Type
Status (Service Disconnect,
Leak detect, Power Qual,
Power Fail, Tamper Detect, Low
Battery, Check Meter)
Others TBD
Manufacturer
Specific Client
•
tbd
Mandatory features
3|Page
Join network, pair devices (ZDP bind and unbind), end device
announce
Factory defaults restore
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
WIRELESS PRODUCT DEVELOPMENT
Rate$aver IHD
Enable Identify Mode by user
Service Discovery (Match descriptor request)
7) Enclosure
•
•
•
•
•
Dimensions
o 100mm x 64mm x 26mm
ABS Plastic
Non-glare Lens
Integrated Magnet for mounting
Front Panel Label: customizable Mylar graphical overlay
8) Power supply
•
•
•
•
Power Source
o 2 AA alkaline batteries
o USB connector power
External Connector (for firmware upgrade)
o USB Mini-B Receptacle
Battery Life: 1 year with 60 second update interval
Reverse Battery Protection
9) Test and Programming Interface
• Firmware Updates: UART interface via mini-B USB connector. External
adapter required to convert USB/RS232 to UART level signals
(provided by LSR).
• Test & Debug: via JTAG Interface with access points in battery
compartment. Supports both DIP and ZIF connector interface
cables (provided by LSR).
10) Screens
•
Screens included as needed for particular customers. Examples include:
o Current tier, current tier rate, total consumption, total monthly bill,
standard header
4|Page
Tier breakdown screen: for each tier –horizontal bar graphs or
numeric table
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
WIRELESS PRODUCT DEVELOPMENT
Rate$aver IHD
ƒ
ƒ
User Messaging Screen / Alarm Display – inverted colors-.
ƒ
Inst power screen – numeric kWatts and bar
ƒ
User Setup and Initialization
ƒ Network ID and Channel
ƒ Join Network button
ƒ Celsius/Fahrenheit
ƒ Time Zone
o Low Power: Screen Display “Replace Battery”
Screen Operation
o Cycle through info screens on SCROLL button press
o Poll and refresh current screen on any button press
o Go to setup screen on SELECT / MENU button held for 5 seconds.
o Automatically switch to message screen when new message
received.
•
11) Information present on all screens (header)
•
•
•
•
Date / Time Display
o Poll ESP no more than once per 24 hours (per SE spec)
o Accuracy within +/-1minute relative to ESP (per SE spec)
Battery/Power Indicator
o V>= 2.0v no battery indication
o 1.6v 40C
Physical shock (consumer level drop test)
o Test per IEC 60068-2-27 (Shock)
o 20g peak acceleration in three orthogonal axis
o Saw tooth pulse shape, 11ms pulse width
Vibration
o Test per IEC 60068-2-6 (Sinusoidal Vibration)
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
WIRELESS PRODUCT DEVELOPMENT
•
7|Page
ESD
Rate$aver IHD
5g-peak acceleration
10-150 Hz
Five cycles per axis in three orthogonal axis
Per CE approval limits specified in ETS 301-489 and EN 61000-4-2
testing methods
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
Rate$aver IHD
WIRELESS PRODUCT DEVELOPMENT
Absolute Maximum Ratings
Rating
Power Supply Voltage Input
Voltage on any digital pin
RF Input Power
Storage Temperature Range
Value
3.5
Max 3.6
+10
-45 to 125
Unit
Vdc
Vdc
dBm
ºC
Note: Under no circumstances exceeding the maximum ratings in Table can be allowed. Such
a stress may cause permanent damage to the devices
Operating Conditions
Characteristic
Min Typ Max Unit
Power Supply Voltage (Vdd)
2.1
3.5
Input Frequency
2405
2480 MHz
Ambient Temperature Range 10
25
70
ºC
Logic Input Low Voltage
0.7
Logic Input High Voltage
2.8
3.6
Radio Electrical Specifications
At 25ºC, Vdd = 3.3V for both APEX and APEX LT unless stated otherwise.
General
Parameter
Min
RF Frequency Range
2400
RF Data Rate
Microcontroller Operating Frequency
Flash Memory
RAM
Typ Max
2483.5
250
12
128
Unit
MHz
kbps
MHz
kB
kB
Power Consumption
Parameter
Min Typ Max Unit
Transmit Mode (100mW output)
Receive Mode
Standby Mode
Boost mode is an optional higher performance radio mode that is software selectable to boost
receiver sensitivity.
Transmitter
Parameter
Nominal Output Power
8|Page
Min Typ Max Unit
20
dBm
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
Rate$aver IHD
WIRELESS PRODUCT DEVELOPMENT
Programmable Output Power range
Error Vector Magnitude
32
15
35
dB
Receiver
Parameter
Receiver Sensitivity (1% PER) – normal mode
Receiver Sensitivity (1% PER) – boost mode
Saturation (Maximum Input Level) (1% PER)
802.15.4 Adjacent Channel Rejection
APEX
Min Typ Max Unit
-92 -96
dBm
-93 -97
dBm
dBm
35
dB
802.15.4 Alternate Channel Rejection
802.11g Rejection (±10 MHz)
40
dB
APEX 40
dB
Control DC characteristics
Parameter
Logic Input Low
Logic Input High
Logic Output Low
Logic Output High
Output source current
Output sink current
Output source current
Output sink current
I/O pin pull-up and pull-down resistor
Min
Typ Max
0.2VDD
0.8VDD
VDD
0.18VDD
0.82VDD
VDD
30
Unit
mA
mA
mA
mA
kΩ
Figure 1
9|Page
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
WIRELESS PRODUCT DEVELOPMENT
Rate$aver IHD
Mechanical Drawing
10 | P a g e
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
WIRELESS PRODUCT DEVELOPMENT
Rate$aver IHD
Disclaimer
LS Research, LLC believes the information in this document is correct and
accurate at the time of release. However, LS Research, LLC reserves the right
to make changes to this product without notice.
Statements
Compliance Statement (Part 15.19)
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received,
including interference that may cause undesired operation.
Warning (Part 15.21)
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment.
FCC Interference Statement (Part 15.105 (b))
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
11 | P a g e
Rate$aver Datasheet (rev. 1.0)
LSR -DS
LS RESEARCH
WIRELESS PRODUCT DEVELOPMENT
Rate$aver IHD
RF Exposure (OET Bulletin 65)
To comply with FCC’s and IC’s RF exposure limits for general population /
uncontrolled exposure, the antenna(s) used for this transmitter must be
installed to provide a separation distance of at least 20 cm from all persons
and must not be co-located or operating in conjunction with any other
antenna or transmitter.
Section 7.1.5 of RSS-GEN
Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received,
including interference that may cause undesired operation.
12 | P a g e
Rate$aver Datasheet (rev. 1.0)
LSR -DS

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2008:09:05 13:42:16-05:00
Create Date                     : 2008:09:05 13:42:16-05:00
Format                          : application/pdf
Title                           : Microsoft Word - User Manual   RS-IHD-24 v1.1 REVISED 1.doc
Creator                         : twhite
Document ID                     : uuid:eef315a5-62d8-4e62-b54f-fd307d6c3f66
Instance ID                     : uuid:c0aa6287-7961-43d0-991e-d306843bf774
Page Count                      : 12
Author                          : twhite
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TFB-RATESAVER