Landis Gyr Technology EC6R1S2 Electronic Endpoint Module User Manual 12 0296 Exhibit Cover

Landis+Gyr Technology, Inc. Electronic Endpoint Module 12 0296 Exhibit Cover

Manual

Download: Landis Gyr Technology EC6R1S2 Electronic Endpoint Module User Manual 12 0296   Exhibit Cover
Mirror Download [FCC.gov]Landis Gyr Technology EC6R1S2 Electronic Endpoint Module User Manual 12 0296   Exhibit Cover
Document ID2034802
Application ID4fO4HEk7rzZwYXC6Wx64hg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize319.72kB (3996505 bits)
Date Submitted2013-08-06 00:00:00
Date Available2013-08-06 00:00:00
Creation Date2013-08-05 16:36:16
Producing SoftwareScanSoft PDF Create! 7
Document Lastmod2013-08-05 16:36:25
Document TitleMicrosoft Word - 12-0296 - Exhibit Cover.doc
Document CreatorMicrosoft Word - 12-0296 - Exhibit Cover.doc
Document Author: courtney.mcgann

Certification Exhibit
FCC ID: R7PEC6R1S2
IC: 5294A-EC6R1S2
FCC Rule Part: 15.247
IC Radio Standards Specification: RSS-210
ACS Project Number: 12-0296
Manufacturer: Landis+Gyr Technology, Inc.
Model: Gridstream RF Enhanced A3
Manual
5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598
Draft 8.5.13
Gridstream RF
Enhanced Series IV
Elster A3 Endpoint
User Guide
Publication: 98-1671 Rev AA
LANDIS+GYR CONFIDENTIAL INFORMATION
Draft 8.5.13
Limitation on Warranties and Liability
Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr.
In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost profits) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised,
knew, or should have known of the possibility of such damages.
© 2013 Landis+Gyr, Inc. All Rights Reserved
Gridstream RF Enhanced Series IV Elster A3 Endpoint User Guide
Publication: 98-1671 Rev AA
Revision History
Modification Date
08/05/2013
Landis+Gyr
6436 County Road 11
Pequot Lakes, MN 56472
Website: www.landisgyr.com
E-mail: solutionsupport.na@landisgyr.com
Technical Support: 1-888-390-5733
Revision
AA
Description
Draft
Author
Kim Utesch
© 2013 Landis+Gyr
All rights reserved.
Draft 8.5.13
Table of Contents
Chapter 1: Endpoint Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Gridstream RF Enhanced Series IV Elster A3 Endpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Endpoint Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Required Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Features and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Communicating via Meter to Endpoint Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Auto-Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Retrieving Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Demand Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Time Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Power Outage/Restoration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
ZigBee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Supporting Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Downloading Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Encrypting Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Configuration Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
FCC and Industry Canada Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
FCC Class B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
RF Exposure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Industry Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Chapter 2: Command Center Deployment/Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Deployment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Auto Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Endpoint Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Meter Manufacturer Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Import Installation File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Import Information File CSV Format requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Time Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Tracking and Deployment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Deployment Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
RF Installation Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Endpoint Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Packet Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Alarm Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Meter Configuration Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Add Meters to a Meter Configuration Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
HAN Setup Process Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
HAN: Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Provisioning HAN Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Application Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Remove HAN Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Management and Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Meter Swap Out Process using Decommission HAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
User Guide
98-1671 Rev AA
Table of Contents
Draft 8.5.13
Landis+Gyr
Commission HAN Network for Channel Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter LCD Screen for ZigBee Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Confirm HAN Radio in Meter is Communicating or HAN is set-up. . . . . . . . . . . . . . . . . . .
Get information for a specific device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Get Firmware version for the HAN radio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Confirm that a HAN device can communicate with the meter . . . . . . . . . . . . . . . . . . . . . . .
34
35
35
35
35
36
Chapter 3: Using Endpoint Testing Manager (ETM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
How To Use ETM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Access to Endpoint Test Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Setting Up Access to the Command Center Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Adding a New Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Selecting an alternate existing server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Modify an existing server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Delete an existing server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Add additional servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
After Login: Setup Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Certificate Attributes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Request MAT Certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
ETM Sign In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Using the Bar-code Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Navigating the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Configuring a New Gridstream IWR Radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Meter Shop Best Practices Use Case - Proper IWR Configuration . . . . . . . . . . . . . . . . . . . . 45
Authentication Server Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Connecting to a Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Connection Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Baud Rate Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Connecting to an Endpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Head End Radio Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Device Test Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
High Speed (115200 bps) Enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Multiple Meter Test Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Enabling Multiple Meter Test Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Editing Multiple Meter Test Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Firmware Download Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Battery End Point Firmware Download . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Module Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Optical Lockout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Reporting Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Demand Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Enabling Demand Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Demand Reset Lockout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Performing a Demand Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Command Scheduler Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Event Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Command Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
HAN Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Universal Event Log Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71
Service Limiting Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
98-1671 Rev AA
User Guide
Landis+Gyr
Draft 8.5.13
Table of Contents
Service Limiting Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Read Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Service Limiting options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Create a Service Limiting Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Send an existing Service Limiting Program to an Endpoint . . . . . . . . . . . . . . . . . . . . . . . . . 76
Groups Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Chapter 4: Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Enhanced Series IV Elster A3 Specs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
User Guide
98-1671 Rev AA
Draft 8.5.13
Draft 8.5.13
Endpoint Overview
Gridstream RF Enhanced Series IV Elster A3 Endpoint
Figure 1 - 1. Gridstream RF Enhanced Series IV Elster A3 Meter and Module
Endpoint Usage
The Gridstream RF Enhanced Series IV Elster A3 endpoint will be used for commercial and
industrial metering applications.
The Gridstream RF Enhanced Series IV Elster A3 communication module requires professional
installation by qualified personnel.
User Guide
98-1671 Rev AA
Chapter 1 - Endpoint Overview
Draft 8.5.13
Landis+Gyr
Required Software
To work with the endpoint, you need one of the following software tools:
•
Command Center version 5.7 or later.
•
RadioShop version 5.4 or later.
•
Endpoint Testing Manager version 5.7 or later.
Labels
The endpoint includes the following label.
CONTAINS FCC ID: R7PEC6R1S2 CONTAINS IC: 5294A-EC6R1S2
XXXXXXXX
MODULE MODEL: GRIDSTREAM RF ENHANCED A3
SERIES IV
Figure 1 - 2. Label Identification
1. LAN ID, includes programmed module part number (printed and barcoded)

NOTE: The LAN ID is a unique identifier for each endpoint. It always displays in hex. Landis+Gyr
provides the LAN address. You cannot change the LAN ID of a radio.
2. Product ID (printed and bar-coded)
3. FCC ID:R7PEC6R1S2
4. IC ID: 5294A-EC6R1S2
Features and Functions
Using the Elster A3 Meter with the Gridstream RF Enhanced Communication Module, you can:
•
Integrate the endpoint into all forms, classes and voltages of the Elster A3 meter.
•
Communicate via serial connection between the endpoint and the meter through the meter's
provided interface.
•
Support all levels of meter passwords.
•
Download radio firmware.
Communicating via Meter to Endpoint Connection
The serial connection is a 26-pin header that contains:
•
Full duplex serial connection. The baud rate is 9600, 8 bits, 1 stop bit, no hardware handshaking.
•
Power fail indication signal from the meter that tells the endpoint to disconnect from
drawing power from the meter.
•
DC power line which supplies power to the module from the meter.
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
•
Chapter 1 - Endpoint Overview
Signal pass through between meter and Elster option board.
Auto-Registration
Endpoint firmware version 7.59 or later and module Device Control Word (DCW) 7.55 or later is
required for auto-registration. After the meter/endpoint is installed in the field it will automatically
register with the Head End System. No special tools are needed during installation as the normal
Utility meter swap process can be utilized.
The meter automatically sends in the registration information containing items on how the meter/
communication module is configured so the host can properly interpret the incoming data. Some of
the items contained in this are as follows:
•
Default Gridstream RF Collector destination
•
Reporting interval for Register Data
•
Reporting interval for Interval Data
•
Meter's AMR-level security password
•
Time Synchronization parameters
•
GMT offset
•
Periodic Register Data reporting
•
Periodic LP Data reporting
•
Meter configuration information
Once this information has been sent the meter/communication module starts collecting and sending
based on the default configuration loaded during manufacturing.
Retrieving Data
The communication module performs data retrieval from the meter on request (ORR) or
autonomously (periodically reported).
Availability of the following features depends on meter configuration. On Request Reads (ORR)
available with this communication module are:
•
Register Data (Standard Table 23) which includes consumption, demand and TOU values.
•
Load Profile or Interval Data (Standard Table 64).
•
Revenue Integrity Services which includes instantaneous measurements related to line
voltage, current and phase angle.
Availability of the following features depends on meter configuration. Options for periodically
reported data with this module include:
User Guide
•
Register Data & Status Flags (Standard Tables 23 & 3) which includes consumption,
demand, TOU values and meter status.
•
Load Profile or Interval Data & Status Flags (Standard Tables 64 & 3) which includes
interval data and meter status.
98-1671 Rev AA
Chapter 1 - Endpoint Overview
Draft 8.5.13
Landis+Gyr
Demand Reset
When Command Center delivers a Demand Reset command, the communication module passes the
command to the meter, which performs the Demand Reset on the meter. The meter/communication
module then passes the previous demand data captured by the meter (Standard Table 25) to
Command Center for processing.
Time Synchronization
Time syncronization is the process of keeping the meter time synchronized with the Gridstream RF
network time within a configurable limit. The communication module automatically keeps its time
synchronized with the Gridstream RF network via periodic background process. The communication
module reads the meter date/clock table (Standard Table 52) periodically, determined by its
configuration. If the time drift between the meter and communication module exceeds the
configured threshold, it sends a time synchronization alert message to Command Center. Command
Center schedules a time change event for the meter and sends it to the communication module. The
time of the change is determined such that the meter’s data integrity is maintained. At the scheduled
time, the communication module executes the standard procedure to change date/time on the meter.
Power Outage/Restoration
When an outage occurs, the meter uses an early power failure signal to alert the communication
module to disconnect from the meter's power immediately. The communication module saves
critical module data to non-volatile memory and creates and sends a power outage message. This
message includes the following information:
•
LAN ID
•
Outage time
•
Reboot count.
The communication module sends the message, then assists with routing other packets until the
back-up energy source can no longer keep the radio alive. The time that this energy source is
available varies with several factors, including amount of data packets being routed, environmental
conditions and age of meter/communication module. Generally, a hold-up time of ~120 seconds is
typical.
At restoration, the communication module first acquires network connectivity. With network
communications restored, the communication module sends a power restoration message that
includes details such as:
•
LAN ID
•
Outage time
•
Restoration time
•
Reboot count.
The communications module stores a history of up to the last five power outage and restoration
event pairs. Command Centercan request this data.
10
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 1 - Endpoint Overview
ZigBee
Support for HAN devices is provided via the ZigBee module, which is certified to Smart Energy
Profile 1.1.
Supporting Passwords
The meter/communication module supports passwords provided by the utility. See publication 981055 Gridstream 2-way Endpoint Testing Manager User Guide for information regarding loading
password into module.
Downloading Firmware
Communications module firmware can be upgraded via Command Center or ETM.
Encrypting Data
The Gridstream RF Network currently supports use of one encryption key per network. If you enable
the Gridstream RF Enhanced with encryption, Command Center must have a matching encryption
key.
Configuration Tables
The Gridstream RF Endpoint Configuration structure passes the data to configure the endpoint. It is
used for both C&I and Residential applications.
This table is currently 55 bytes long. It contains information necessary to configure several services
on the endpoint, such as firmware reads, autonomous data return configuration.
The endpoint receives the packet, and using the data, configures its own operation. The host
maintains a record of the endpoint’s configuration.
User Guide
Item
Other
Packet Contents
Identifies which elements in this packet are set. Elements that are not set are
ignored. There still must be a place in the packet for it, though.
Config Byte 1
Not Used
Config Byte 2
Not Used
Config Byte 3
Not Used
Config Byte 4
Not Used
Config Byte 5
Not Used
Reporting Interval LP
In Minutes.
Pump Period Register
In Minutes.
Pump Period RIS
In minutes. The period for the RIS/Vector/Voltage data pump.
Pump Period Status
In minutes. The period for the Device Status (SO3, typically) data pump
98-1671 Rev AA
11
Chapter 1 - Endpoint Overview
12
Draft 8.5.13
Landis+Gyr
Item
Other
Pump Period Snap Read
Snap Reads will be delivered at a pseudo-random time, which will occur in
the first X hours of each day. X is the value that is provided here. It will default
to 2. The process is: this value, which is in hours, will be converted to
minutes. The LAN ID will be mod-ed with this minute value, and the result will
be the minute of the day that the self read is transmitted.
User ID
2 byte User ID used while running ANSI Logon Service
Logon User
10 byte User Name that is used while running the ANSI Logon Service
Security Password
The full 20 bytes are required.
Sustained Outage
Duration
Defines the number of seconds after which an outage will be classified as
sustained. If less than this amount, the outage is momentary. A value of zero
will cause all outages to be considered "sustained".
Max Meter Time Drift
The number of seconds that the meter clock can drift from the radio clock,
after which an alarm is triggered.
Meter Time Read Period
The number of seconds that the meter clock can drift from the radio clock,
after which an alarm is triggered.
GMT Offset
The GMT Offset in 15 minute increments. Signed.
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 1 - Endpoint Overview
Theory of Operation
The Gridstream RF Elster A3 module is an electric endpoint with 900MHz Gridstream and ZigBee
communications on a single PCB. This product will be integrated into the Elster A3 C&I meter. The
following figure shows the high-level block diagram of the module. Each functional block is
described in the following sections.
DC-DC
Converter
Constant
Current
(LT1618EMS)
11V ч Vin ч 14V
100 mA max
UART
Elster A3
Meter
Interface
3.6V
4.5V
(3.9V when
temp>65°C)
Supercap
5F
1.8V to 4.5V
DC-DC BuckBoost
Regulator
(LTC3530EMS)
LDO
(LP3985IM5-3.3)
LDO
(LP3985IM5-3.3)
3.3V
DVCC
3.3V
RFVCC
/PFAIL
UART
14.7456 MHz
Data Flash
4MB
SPI
Supervisor
+ Watchdog
/RESET
Filter
32.1 MHz TCXO
900MHz FEM
PA+LNA+RF
switch
RX
Renesas
R5F3650TDFB
SPI
GPIO
Semtech
Transceiver
SX1232
TX
Filter
RF connector
10dB Pad
SiGe SE2435L
768K Flash
47K RAM
GPIO
JTAG
SAW
GPIO
UART
ZB ANT 1
24 MHz
JTAG
Ember
EM357
192K Flash
12K RAM
GPIO
DiīerenƟal Tx
DiīerenƟal Rx
2.4GHz FEM
PA+LNA+RF
switch
Filter
SiGe SE2432L
Filter
RF connector
ZB ANT 2
Figure 1 - 3. Block Diagram
FCC and Industry Canada Compliance
FCC Class B
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the Instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reUser Guide
98-1671 Rev AA
13
Chapter 1 - Endpoint Overview
Draft 8.5.13
Landis+Gyr
ception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Consult Landis+Gyr or an experienced radio technician for help
WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr
could void the user’s authority to operate the equipment.
RF Exposure
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20 cm
between the radiator and your body. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
Industry Canada
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a
type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner
avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par
Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des
autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une
communication satisfaisante.
This radio transmitter (5294A-EC6R1S2) has been approved by Industry Canada to operate with the
antenna types listed below, with the maximum permissible gain and required antenna impedance for
each antenna type indicated. Antenna types not included in this list, having a gain greater than the
maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio (5294A-EC6R1S2) a été approuvé par Industrie Canada pour fonctionner
avec les types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance
requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain
est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
Approved Antenna: Elster P/N 1B12150H01, +1dBi Gain, 50 ohms
14
98-1671 Rev AA
User Guide
Draft 8.5.13
Command Center
Deployment/Configuration
Deployment
Auto Registration
Landis+Gyr RF radio is Plug & Play; meters equipped with Landis+Gyr endpoints arrive from the
factory in operational mode, ready to be installed at a service location. Along with the meters, a
Meter Manufacturer File is provided to the utility. This file contains meter number/serial number
combinations; the file must be uploaded into Command Center prior to installation of endpoints in
the field.
A meter installer installs the endpoint at the service location.
Once installed, the endpoint will begin the following auto-registration process:
1. The endpoint listens for RF traffic and evaluates its neighbors, searching for the best possible
path to the collector. The best path is the one with the fewest hops to the Collector and through
an endpoint with the highest Receive Signal Strength Indicator (RSSI) (RSSI is the receive
signal strength from the node. It is a rough indicator of how strong the signal is from the radio).
2. Having identified the best path, the endpoint will transmit the following two packets:
•
RF Registration Packet: The RF Registration Packet identifies for the Collector the return
path to the endpoint. This is achieved by each intermediary endpoint adding its LAN address
to the endpoint’s RF Registration Packet as it travels to the Collector. Once the RF
Registration Packet is received, the endpoint will transition to Discovered in Command
Center. The RF Registration will continue to be sent until the SetWAN command is received
from Command Center.
•
Init Push: The Init Push packet contains configuration information about the meter, that
allows Command Center to understand the configuration of the meter. The Init Push is
transmitted until the SetWAN command is received from Command Center.
3. Once the RF Registration Packet and Init Push are received, Command Center will validate the
configuration and, if validated, begin accepting readings from the endpoint. The endpoint will
remain in Discovered status until the SetWAN command is received by the endpoint.
4. The SetWAN command is issued to the endpoint when Command Center receives latitude and
longitude information AND the endpoint’s closest neighbor has a WAN address. The SetWAN
command provides the endpoint with its WAN address. The WAN address is the radio’s physical
location (Latitude and Longitude) expressed in degree, minutes and seconds. The SetWAN
command achieves two way communication with the endpoint. The SetWAN tells the endpoint
that we have received your configuration information and it is OK to stop sending it in.
User Guide
98-1671 Rev AA
15
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration

Landis+Gyr
NOTE: If Installation Data is received before an Init Push has been received, the installation record
will be stored awaiting the Init Push from the device.
Endpoint Status
Endpoints will move from one status to another during the deployment process. The following are
various endpoint statuses:
•
Installed. Endpoints in the Installed status have been deployed in the field, but Command
Center has not received the RF Registration packet.
•
Discovered. Endpoints in the Discovered status have transmitted an RF Registration Packet.
The RF Registration Packet identifies for the Collector the return path to the endpoint. This
is achieved by each intermediary endpoint adding its LAN address to the endpoint’s RF
Registration Packet as it travels to the Collector.
•
Normal. Endpoints in the Normal status have transmitted an Init Push packet containing
configuration information AND have acknowledged a SetWAN command from Command
Center. The SetWAN command provides the endpoint with its WAN address. The WAN
address is the radio’s physical location (Latitude and Longitude) expressed in degree,
minutes and seconds.
•
Lost. Endpoints in the Lost status have reported an outage event. When the endpoint loses
power, it will transmit a “Power Outage Event” to Command Center. Once power has been
restored, the endpoint transmits a “Power Restore Event”. The endpoint will then transition
back to Normal status.
•
Configure. Endpoints in the Configure status are endpoints that have been recently added to
a new configuration group and have not yet confirmed the receipt of configuration
commands.
•
Failed. Endpoints and/or meters in the Failed status have failed a re-configuration attempt or
have failed a work flow process. Work flow processing will determine if configuration
changes such as time zone updates, reconfiguring of endpoints, meter change programs have
been successful. Endpoints must be manually removed from the Failed status, generally by
attempting the work process again.
•
Archive. Endpoints in Archive status are no longer in use within the Mesh System, for
example, damaged endpoints. Endpoints must be manually entered into Archive status.
•
Inventory. Endpoints in Inventory status have not yet been deployed in the field. These may
be recently purchased meters or meters that have been removed from the field and are
awaiting redeployment.
Meter Manufacturer Data
The Meter Manufacturer Data screen allows the user to import an XML or CSV file supplied by the
meter manufacturer so the utility does not have to key in meters and endpoints by hand.
1. Click Operations > Import > Meter Manufacturer Data to display the Import Meter
Manufacturer Data screen.
16
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 2 - Command Center Deployment/Configuration
Figure 2 - 1. Import Meter Manufacturer Data
2. Click the Browse button to navigate to, and select, a file that was sent by the meter
manufacturer.
3. Click the Save button to import the file into the database.
The Meter Manufacturer Data Import (Upload Complete) window will appear displaying the Error
Summary (if applicable) and Successful Entries.
Figure 2 - 2. Upload Complete Window

NOTE: Any entries under Error Summary will be red text. The usual reason for an entry under Errors
is that the endpoint already exists in the system. If file parsing errors or other file-related errors
occur, contact the meter manufacturer that supplied the file.
4. Successful entries will be added to inventory and will be displayed on the dashboard as
Inventory status.
Import Installation File
Meter deployment details can be imported by use of an Installation File provided by the installer.
Following is the procedure for importing the installation file.
1. Click Operations > Import > Import Installation File to display the Import Installation File
screen.
User Guide
98-1671 Rev AA
17
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
Landis+Gyr
Figure 2 - 3. Import Installation File Screen
2. Enter the Path to the file.
...or...
3. Click the Browse button to navigate to, and select, a file containing the endpoint information.
4. Click OK to upload the file. The information imported via the Installation File:
Table 2 - 1. Installation File Fields
Data
Format
Format/Description
User ID*
AlphaNum (30)
Login assigned by the utility for the installer. Utility may
elect to use “1” for System usage.
Installation Date*
Date
MM/DD/YYYY
12/26/2009
Actual date the meter was installed. This date is used in
various Command Center reports to track deployment
statistics.
Installation Time*
Time HHMM AM/PM
11:12 AM
Actual time the meter was installed. This date is used in
various Command Center Reports to track deployment
statistics.
Change Out meter
number
AlphaNum (20)
The meter being replaced with a new meter. Meter change
out information is displayed in the notes section of the
endpoint information screen.
Change Out meter
kWh
AlphaNum (20)
The kWh reading on the meter being replaced Meter
change out kWh information is displayed in the notes
section of the endpoint information screen. Variable
Character.
Installed Meter
Number*
AlphaNum (20)
Meter number of the new meter being installed. This meter
must exist in Command Center prior to importing the
Import Installation File. Must parse to Decimal format.
Installed Endpoint
Serial Number*
Decimal (9)
The serial number of the new meter being installed. Note:
Endpoint serial numbers must be converted from Hex to
Decimal.
Installed Meter kWh
Decimal (9)
Initial reading of the new meter.
Service Latitude
Decimal (12,8)
GPS latitude.
Service Longitude
Decimal (12,8)
GPS longitude.
Service Location
AlphaNum (100)
Meter service location.
* Indicates a required field.
18
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 2 - Command Center Deployment/Configuration
Table 2 - 1. Installation File Fields (Continued)
Data
Format
Format/Description
Service Time Zone
See formatting
below.
The service time zone may be entered to specify the
correct time zone for the service location.
* Indicates a required field.
Import Information File CSV Format requirements
CAUTION: Required fields are UserID, Installed Date, InstalledTime, InstalledMeterNo, and
InstalledEndpointSN. If these fields are not populated, the file will not be processed. Service
Location is required if the Latitude and Longitude fields are populated. Command Center will
ignore the latitude and longitude values if Service Location is not provided.
The Import Installation File window provides a CSV template link. Click this link to view the format
requirements for the file. This template can be saved to a network location or local machine and
provided to the installer.
The Installation file must be of the following format:
•
The first line must be a header.
•
A comma is required to separate each item even if no data exists.
•
A Service location is required if the service latitude and longitude are provided.
Time Zone
In order to report reading time correctly, the endpoint must be programmed with the appropriate time
zone; this is achieved by sending commands to the endpoint that indicates the time zone in which the
endpoint is installed and whether Daylight Savings Time (DST) is observed in the given time zone.
The Installation File should include the endpoint time zone. Clicking the Time Zone List link will
open a document that displays a list of valid time zone designations by country.
Figure 2 - 4. Time Zones
User Guide
98-1671 Rev AA
19
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
Landis+Gyr
Tracking and Deployment
Deployment Status
Deployment Status enables users to monitor the find process when endpoints are being deployed on
a system.
1. Click Network > Deployment Status to display the Deployment Status Report screen.
Figure 2 - 5. RF Deployment Status Screen
2. Choose the Selection Criteria:
A. All
...or...
B. Collector. Select the desired collector from the drop-down menu.
3. Select a Date Range:
A. Start Date. Click the calendar icon, and then click on the desired start date.
B. End Date. Click the calendar icon and then click the desired end date.
4. Click the OK button to display the RF Deployment Status Report.
Figure 2 - 6. RF Deployment Status Report
The RF Deployment Status Report displays a graph representing 14 days of installation statistics and
a chart. Time periods longer than 14 days may be selected, but will not be presented on the graph due
20
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 2 - Command Center Deployment/Configuration
to space limitations. By clicking on a specific date, each endpoint registering that day displays
installation, registered, normal and reading status for this date. Information on the report is updated
as the information is received by Command Center on a rolling seven day basis. Installation
information is populated from the RF Installation File Import process. Registered and Normal status
updates are based on receipt of the two registration requests from the endpoints. Readings are based
on the first reading received from the endpoint. Average deployment time is based on the time it
takes to go from installed to normal.
5. Click on the Date link to display the Gridstream Meters Deployed By Day report.
Figure 2 - 7. RF Meters Deployed by Day
RF Installation Status
The RF Installation Status Report is intended to be used by utilities during mass deployment. It can
be used as an installation tool to determine how many meters have been installed over a specified
time frame and of those meters how many have been discovered, how many have moved to normal
status, how many are sending readings, and how many have sent readings in the past 24 hours.
Following is the procedure for viewing the RF Installation Status report:
1. From Command Center, select Network > RF Installation Status. The RF Installation Status
window will open.
Figure 2 - 8. RF Installation Status
2. Selection Criteria. Select All to view results for all collectors in the system
...or...
Select the desired collector from the drop down box to view results for only that collector.
3. Date Range. Enter a Start Date and End Date. Select the Calendar icon to view a calendar and
make date selections if needed.
4. Click OK. The RF Installation Status report will be displayed, shown in Figure 2 - 9.
User Guide
98-1671 Rev AA
21
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
Landis+Gyr
Figure 2 - 9. RF Installation Status Report
The following information is displayed in the report:
•
Day. This number will increment for each day the used has selected to display.
•
Date. This will display the dates selected in generation of the report. Click the date link to
view a list of all meters deployed on the selected date.
•
Daily Installed. This will display the number of endpoints installed for that particular day.
The daily installed data is imported into Command Center via the Installation File.
•
Discovered. Of the total number of meters installed on the summary date, the total number
of those that have transitioned into a Discovered state and the percentage
(Discovered meters/Installed meters).
•
Normal. Of the number of meters installed on the summary date, the total of those meters
that have transitioned to a normal state at that point in time and the percentage (Normal
meters/Installed meters).
•
Readings. Of the total number of meters installed on that day, the number of those meters
that have sent in a billable reading packet, and the percentage (meters that have sent a
billable reading packet/total meters installed on that day).
•
Readings past 24 Hours. Of the meters that were installed on that day, the total number of
meters that sent in a billable readings packet in the last 24 hours (from the point the report
was generated) and the percentage (meters that sent in a billable readings packet in the last
24 hours/total meters installed on that day).
•
Cumulative installed. The total number of meters that have been installed up to that date.
•
Normal. The total cumulative number of meters that have transitioned to Normal status up
to that date.
The color-coded bar graph displays the following deployment information:
22
•
Cumulative number of meters installed for each date (Grey).
•
Current number of meters that have transitioned to Normal status (Green).
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 2 - Command Center Deployment/Configuration
•
Number of installed meters that have sent in a billable reading in the last 24 hours (Blue).
Endpoint Configuration
Packet Definitions
Creating a packet definition is necessary to reconfigure the packet payload of an endpoint. Packet
definitions can contain several different user-configurable data elements.

NOTE: RF endpoints allow a user to return up to 6 registers. However, the more registers returned,
the greater the strain on the network.
1. Click Setup > Packet Definitions > RF Residential
The Packet Definitions screen will be displayed.
Figure 2 - 10. Packet Definitions Screen
2. In the Packet Definitions screen (above) click the New button to display the Packet Definition
window.
User Guide
98-1671 Rev AA
23
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
Landis+Gyr
Figure 2 - 11. The Packet Definition Window
3. Enter a name in the Packet Name field. The name should be unique to the organization.
4. Click the Edit Description link to enter any desired notes for the packet definition. If any notes
were entered, click the OK button to save them.
5. Select a Packet Type from the drop-down.
•
On Demand. Used for RF Endpoints.
•
Daily Packet Type. Used for PLC Endpoints
6. Select the Meter Type from the drop-down.
7. Select the desired data options from the Available Data Options window on the left side of the
screen.
To view a description of each available data option, click once on the data element. A
description of the data element will be displayed in the yellow shaded box in the lower-center
area of the screen.

NOTE: The available data options vary depending on the type of endpoint.
8. Click the right pointing arrow to move the data option to the Selected Data window.
As you select data options, monitor the Packet Capacity gauge on the right of the screen. Each
selection will add to the percentage total. If your selections exceed 100 percent, a message will
be displayed when you click the Save button indicating that packet capacity must be 100% or
less and can contain six or fewer data items. You can remove selections from the Selected Data
window by clicking to highlight the selection and then click the left pointing arrow to remove
the selection.
9. After selecting all of the desired data options, click the Save button to save the new packet
definition.
24
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 2 - Command Center Deployment/Configuration
Alarm Definitions
Alarm Definitions determine what type of response the given Events will trigger, including
Dashboard Alerts and Email Alerts. Alarm Definitions must be created prior to Meter Configuration
Groups in order to be programmed to a module.
1. Click Setup > Alarm Definitions and select the appropriate endpoint type to display the Alarm
Definitions screen.
Figure 2 - 12. Alarm Definitions screen
2. Click the New button to display the Alarm Definition screen.
Figure 2 - 13. Alarm Definition screen
3. Enter an Alarm Definition name in the Name field.
4. Choose the desired setting for each event. See below for setting descriptions.
Available Settings
Result
Disabled
Log Only
Advisory
Alarm
Logged in module



Available via request




Event is:
Included in next

Transmitted immediately

Flagged on Dashboard

Included in E-mail Alerts


NOTE: The default Alarm Definition settings represent the recommendation of Landis+Gyr.
5. Click the Save button.
An Alarm Definition can only be edited if it is not already part of an existing Configuration Group.
User Guide
98-1671 Rev AA
25
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
Landis+Gyr
Meter Configuration Groups
A Configuration Group is a type of Command Addressing Group. A meter can be a member of only
one configuration group. All members of a configuration group must be assigned the same
configuration settings. Configuration groups are used to drive group-based reconfigurations for
multiple endpoints.
Each endpoint type is manufactured with a default configuration group.
The data transmitted by an RF module, how frequently the data is sent, and how the module
responds to conditions in the field, is dictated by the endpoint’s Configuration Group.
An RF Endpoint configuration consists of the following:

•
Packet Definitions that are built for various data elements to be captured by the endpoint.
•
Alarm Definitions that establish the priority associated with events that occur in the RF
endpoints.
•
RF Network Settings that establish the outage wait and time synchronization settings.
•
A schedule that includes the commands and packet definitions, along with time settings and
frequency settings associated with data transmission, that are stored in the endpoint.
NOTE: During the Auto-registration process, the module transmits an Init Push packet which
indicates its configuration. This enables Command Center to associate the endpoint with the
appropriate configuration group. If the configuration transmitted does not match an existing
configuration in Command Center, a new configuration group may be auto-generated to which the
endpoint will be assigned. For this process to occur, the Auto Generate Meter Configuration Groups
setting must be enabled in System Settings.
1. Click Setup > Groups > Meter Configuration Groups and select the endpoint type.
The Configuration Group screen will be displayed.
Figure 2 - 14. Configuration Groups Window
If you wish to view the details of an existing configuration group, perform the following steps.
A. In the Configuration Group window click the View Meters icon for the Configuration
Group you want to view to display the Group Summary window.
26
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 2 - Command Center Deployment/Configuration
Figure 2 - 15. Group Summary Window
The group membership list window displays the following categories:
•
Status. Status is the current status of the meter.
•
Total Meters. Displays the total number of meters in each status.
B. Click any of the meter number links to view the Endpoint Properties window for the
selected meter.
2. In the Configuration Groups window click the New button to display the Configuration Group
Properties window.
Figure 2 - 16. Configuration Group Properties Window
3. Enter a Group Name. The name must be unique within the organization.
4. Enter any desired Group Notes.
5. To set up Scheduled Commands use the following steps:
A. Select the desired packet definition from the Command drop-down.
B. Select the Time at which the reading will be taken from the meter. Adjust the time by
clicking on either the hours, minutes, or AM/PM and then using the up or down arrow.
C. Select the Frequency with which the reading will be taken from the meter.
If either Every n minutes or Every n hours is selected, an additional field, N, will be
displayed.
Figure 2 - 17. Frequency Interval
User Guide
98-1671 Rev AA
27
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
•
Landis+Gyr
Select the desired interval from the Frequency drop-down.
D. Click the Schedule Command icon to add the command to the Scheduled Commands list.
Figure 2 - 18. Scheduled Commands
E. (Gridstream endpoints only) Select the Delayed check-box for a command.
6. Repeat step 5 for any additional commands.
7. Select the Endpoint Transmit Interval from the drop-down. This setting determines how often
the endpoint will transfer its readings to Command Center.
8. Select the appropriate RF Network Settings from the drop-down.
Outage Wait Value*
LG RF Commercial
Configuration A
LG AU Residential
Network
Configuration A
RF Residential
Configuration A
Hunt RFS Gas
Configuration
Hunt RFS S4
Configuration A
Default RF Collector
Configuration
Parameter
Hunt RFS Residential
Configuration A
Table 2 - 2. RF Network Settings Parameters
30
Tamper Threshold**
10
30
10
Time Synchronization
(X, Y)†
1,1
20, 60
20, 60
20, 60
20, 360
20, 60
20, 1
*Outage Wait Value
The length of time (in seconds) that an endpoint will wait during a power
outage situation before sending an outage notification to Command Center.
**Tamper Threshold
The number of reverse pulses of -kWh an endpoint must see within an
interval before triggering a "Tamper Alert".
†Time Synchronization
The number of seconds that the meter time may drift before an automated
time synchronization must be performed (X), or an alert must be generated and sent to Command Center (Y).
9. Select an RF Alarm Definition from the drop-down.
10. Click the Save button to save the new configuration group.
Add Meters to a Meter Configuration Group
Adding meters to a configuration group initiates the configuration process.
1. Click Setup > Groups > Meter Configuration Groups and select the endpoint type.
The Configuration Group screen will be displayed.
28
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 2 - Command Center Deployment/Configuration
Figure 2 - 19. Configuration Group Window
2. Click the Add Meters icon for the Configuration Group to which you want to add meters in
order to display the Add Meters to Group window.
Figure 2 - 20. Add Meters to Group Window
3. Click the Meter(s) radio button and enter individual meter numbers separated by spaces,
commas, or semi-colons.
...or...
4. Click the Meter File radio button and then the Browse button to browse for a .csv file
containing all the necessary meter numbers.
5. Click the Add button and then the Exit button to save the additions.
After clicking the Add button, the user will receive feedback on how many meter numbers were
successfully and/or unsuccessfully added. The reason for an unsuccessful message is that the
meter number does not exist.

NOTE: If a meter is already in a configuration group, the meter will be removed from the original and
added to the new configuration group.
HAN Setup Process Overview
Pre-requisite:
•
User Guide
Meters must be ZigBee-enabled and in Normal status before any of the following HAN
functionality commands are usable.
98-1671 Rev AA
29
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
Landis+Gyr
1. Send the HAN: Initialization command to the ZigBee-enabled meter, if not already completed
during 5.6 (or later) Gridstream System Release upgrade.
2. Provision HAN Devices
3. Provisioned devices can utilize the following HAN applications:
A. Usage/Metering Information.
B. Text Messaging.
C. Load Control.
D. Pricing/Rate Information.
4. Remove HAN Devices from Home Area Network:
A. HAN: Delete Device.
B. HAN: Clear Devices.
C. Decommission HAN.
5. Management & Troubleshooting:
A. Meter Swap out process using Decommission HAN.
B. Commission HAN Network for Channel Control.
C. Meter LCD Screen for ZigBee Alerts.
D. Confirm HAN Radio in Meter is Communicating or HAN is set-up.
E. Get information for a specific device.
F. Get FW version for the HAN radio.
G. Confirm that a HAN device can communicate with the meter.
HAN: Initialization
The HAN: Initialization command provides the meter with key information that the Home Area
Network will need to properly communicate metering information to HAN devices. This process
allows the module firmware to flexibly adjust its meter information collection process to work with
any meter or meter program.

NOTE: The HAN: Initialization command is new to Gridstream with System Release 5.6, and
required to be sent to all existing or new Home Area Networks.
Please see publication 98-1188: HAN Initialization and Firmware Transition Guide for more
details on the HAN Initialization process. This document includes the full process, as well as
expected results or potential issues. It is expected that users will leverage this document in parallel to
this user guide.

NOTE: If a HAN command is sent to a meter before the HAN: Initialization command has been
successfully sent to a meter, the HAN command will fail and the HAN: Initialization command will be
sent to the meter in its place. Once the initialization process is complete, the original HAN
command, which was failed, will need to be retried by the user or 3rd party system.
Under the Manage Tab on the Endpoint Information Window, select the HAN: Initialization
command from the drop-down menu and press Send. This will cause the meter to change from a
30
98-1671 Rev AA
User Guide
Landis+Gyr
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
status of Normal to a status of Configure. This status change indicates that the HAN initialization
process is underway. Once the meter status changes from Configure to Normal the HAN
initialization process is complete.
Figure 2 - 21. HAN: Initialization
Provisioning HAN Devices
Provisioning a HAN device (such as a display, smart thermostat, or direct load control unit) securely
joins a specific ZigBee-enabled HAN device with a specific meter so that they can communicate
across their meter's Home Area Network.
When the first HAN device for a meter is provisioned, a Home Area Network is automatically
commissioned. This involves Gridstream assigning a Channel (from a list of preferred channels) and
HAN ID. If there is a need to specifically assign the Channel and or the HAN ID, use the HAN:
Commission Network Command, as described under the Management and Troubleshooting section
below.

NOTE: Up to 5 devices may be provisioned to a single Non-Enhanced meter and up to 10 devices,
8 of which may be DRLC devices, for a single Enhanced Meter.
A device can be provisioned in two ways from Command Center: either 1) HAN Tab or 2) Manage
Tab on the Endpoint Information Window:
1. On the Endpoint Information Window, select the HAN tab.
Click the New button to display the new device fields shown below.
User Guide
98-1671 Rev AA
31
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
Landis+Gyr
Figure 2 - 22. HAN Tab
...or...
2. On the Endpoint Information Window, select the Manage Tab.
Figure 2 - 23. Manage Tab
A. Enter the MAC Address. (Listed either on the HAN device or HAN device packaging.)

NOTE: A Media Access Control address (MAC address) is a unique identifier assigned to most
network adapters or network interface cards (NICs) by the manufacturer for identification.
B. Enter the Install Code. (Listed either on the HAN device or HAN device packaging)
C. Click the Send button. This will notify the Meter to open a Join Window for the specified
HAN device.

NOTE: The window of time during which the customer may complete registration is determined by
the user configuration setting in the Organization Information screen and must be set to a value of
between 1 to 30 days.
3. The HAN or Manage Tab will be updated with a device status of Provision Request, which
indicates that the Meter has opened a Join Window for the specified device. The MAC Address
and Install Code for the specified device will be shown in the updated window as well.
Figure 2 - 24. MAC Address
4. Once initial contact with the specified device has been made, the device status will update to
Find Pending.

32
NOTE: You may need to click the Refresh icon periodically to determine if the device has entered
the Find Pending status.
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 2 - Command Center Deployment/Configuration
5. When the device is in the Find Pending status, the customer (end device user in premise) may
need to complete registration by joining or accepting the HAN network; if needed, this is often
accomplished simply by pressing a button on the device. This is not always necessary because
some HAN devices have completely automated this process, requiring no user interaction. This
process can vary by HAN device; please consult the device user's guide or manual for details.
6. Once the device joins the HAN network, the Status will change to Normal and the Device Type
field will be populated. The HAN Device is now joined and ready for use.
Application Summary
For provisioned HAN devices, the following functionality/communication may be possible,
depending on what is supported by that device. Gridstream's support of these applications is further
detailed in the Command Center User Manual, as well as the Integration Suite SDK.
•

Usage Information: Once provisioned, HAN devices can receive usage information, such
as kWh and kW, as values are updated by the meter.
NOTE: The usage information available to the HAN devices from the meter will depend on the type
of meter, as well as the Smart Energy version of the HAN device.
•
Text Messaging: Character-based text messages can be sent to in-home displays from either
Command Center or via Integration Suite.
•
Load Control: Direct load control commands such as thermostat temperature adjustments
and load-based duty cycling can be sent via Integration Suite.
•
Pricing Information: Energy rate information for both flat or Time-of-Use structured
pricing can be sent via Integration Suite.
Remove HAN Devices
Removing (de-provisioning) a HAN device from the Home Area Network can be accomplished in
three ways:

User Guide
•
If the user wishes to remove a single HAN device and leave the HAN Network
Commissioned, use the HAN: Delete Device command under the Manage Tab on the
Endpoint Information Screen.
•
If the user wishes to remove ALL HAN devices but leave the HAN Network Commissioned,
use the HAN: Clear Devices command under the Manage Tab on the Endpoint
Information Screen.
•
If a user wishes to remove a single or all HAN devices and decommission the Home Area
Network, use the HAN: Decommission Network command under the Manage Tab on the
Endpoint Information Screen and click Send.
NOTE: If a HAN Network has been decommissioned, when the HAN Network is re-commissioned it
will setup new trust center encryption keys and will reassign a random Channel and HAN ID if not
specifically assigned through the HAN: Commission Network command. It will be necessary to reprovision any HAN devices since this will be a new unique HAN Network.
98-1671 Rev AA
33
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
Landis+Gyr
Management and Troubleshooting
Meter Swap Out Process using Decommission HAN
For management and troubleshooting of the HAN Network and associated HAN devices, the
following commands can be used: Commission Network, Get Network Info, Get Device Info, Get
Firmware, and Ping.

NOTE: If a meter needs to be swapped out, the HAN must be decommissioned, or at very least, all
the HAN devices must be removed. Removing these devices will allow them to be re-provisioned
on the replacement meter.
Commission HAN Network for Channel Control
The HAN: Commission Network command is used to commission a HAN network with a specific
Channel and HAN ID. This command can be used to troubleshoot scenarios in which there may be
channel interference or spotty communication with a HAN device.

NOTE: A HAN Network will be automatically commissioned by provisioning a HAN device to a
meter if no HAN network is present. The automatic process will randomly assign the Channel from a
list of preferred channels as well as the HAN ID. See the section "Provisioning HAN Devices" for
details on adding/provisioning a HAN device to a meter.
1. On the Endpoint Information Window, select the Manage tab. Select HAN: Commission
Network from the Issue Commands drop-down menu. The user will need to select the
Channel and HAN ID.
Figure 2 - 25. Commission HAN Network
2. For Channel, choose Auto Select which will randomly select a SEP preferred channel
...or...
3. Select a specific channel 11-25.
HAN ID field will display the selected HAN ID.
34
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 2 - Command Center Deployment/Configuration
4. Click Send.
Meter LCD Screen for ZigBee Alerts

NOTE: After installation, the meter display will flash Z/B under the following conditions:
No network commissioned: The ZigBee module will request the time from the Gridstream radio
every 30 seconds after power up and every 15 minutes once it has received the time from the radio.
HAN Network is commissioned: When HAN is present, regardless of any devices present, the
ZigBee module will read the meter data every 30 seconds in anticipation of HAN devices needing
that information.
Confirm HAN Radio in Meter is Communicating or HAN is set-up
To confirm the existence of a HAN Network or to gather details on the HAN Network, issue the
HAN: Get Network Info command.
It will return the Channel and HAN ID.
Figure 2 - 26. HAN Network Info
Get information for a specific device
To confirm device details issue the HAN: Get Device Info command. It will return the MAC
Address, the Installation Code, and Device Type i.e: In Premise Display, Programmable Controllable
Thermostat.
Figure 2 - 27. HAN Device Info
Get Firmware version for the HAN radio
To confirm which firmware the HAN module in the meter is using issue the HAN: Get Firmware
command. This will return the ZigBee Firmware version number which will allow the user to figure
out if the meter is running the proper ZigBee Firmware.
User Guide
98-1671 Rev AA
35
Draft 8.5.13
Chapter 2 - Command Center Deployment/Configuration
Landis+Gyr
Figure 2 - 28. HAN Firmware Info
Confirm that a HAN device can communicate with the meter
To confirm if Command Center can communicate with a HAN device or whether a HAN device is
still in communication with its meter, issue the HAN: Ping command. The Ping HAN Device Status
will be returned notifying the user that the Ping Command was issued. To verify that the device was
Pinged, check the history on the Manage Tab as the response from the device will be logged in the
device history.
Figure 2 - 29. HAN Ping Device
36
98-1671 Rev AA
User Guide
Draft 8.5.13
Using Endpoint Testing
Manager (ETM)
How To Use ETM
Endpoint Testing Manager (ETM) software provides the user with the ability to verify accurate
module-to-meter, meter-to-module, module-to-network, and network-to-module communications.
This chapter provides detailed instructions for navigating the software.
Access to Endpoint Test Manager
With the release of Command Center 5.0, ETM users must be authenticated into Command Center
prior to accessing the ETM application and communicating with devices in the network. The
designated Security Administrator for the utility is responsible for configuring the connection to the
Command Center server, and for providing log in credentials (including user names and passwords)
for those who will require access to the software.
Setting Up Access to the Command Center Server
Before launching the ETM software, a link to the Command Center server must be created. Follow
the steps below to create the link to the Command Center server.
•
Launch ETM software. The ETM Sign in screen will open. On an initial launch of ETM, the
ETM user must be authenticated with the Command Center server. The Command Center
server connection places an authentication token on the user’s computer. This token is valid
for a time specified by the Command Center Administrator. On succeeding launches, the
Server Name field may display Offline, and may display Offline during future logins. Users
may login to ETM without Command Center server connection, as long as their
authentication token is valid.
Figure 3 - 1. Endpoint Testing Manager - Sign In
User Guide
98-1671 Rev AA
37
Draft 8.5.13
Chapter 3 - Using Endpoint Testing Manager (ETM)
•
Landis+Gyr
If this launch of ETM is not connected to a server, click the Select a new server link. The
Server List will appear.
Figure 3 - 2. Server List
•
Click the name of the desired server in the Server column to highlight it.
•
Click Select. The Server List window will close and the selected server will be displayed on
the ETM log in screen.
Adding a New Server
Click Add on the Server List. The New Server window will open.
Figure 3 - 3. Endpoint Testing Manager - New Server
•
Server Nickname: Enter a user-defined name for this server.
•
Server Location: Enter the physical location of the server.
•
Server FQDN: Enter the fully qualified domain name for the server. (see example in the
New Server display).
•
Make this my default Authentication Server. Enable this setting to connect to this server
each time this instance of ETM starts.
•
Click Submit to add the new server.
Selecting an alternate existing server
An ETM instance may have multiple servers associated to it. When ETM is first started, the server
that has been selected by default will be displayed on the log in screen. The user may choose a
different server, if necessary.
38
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 3 - Using Endpoint Testing Manager (ETM)
Following is the procedure for selecting an alternate server:
From the ETM log-in screen, select the Select a new server link. The Server List window will
appear.
•
Click the name of the desired server in the Server column.
•
Click Select. The Server List window will close and if ETM can connect to that server, the
selected server will be displayed on the ETM login screen.
Modify an existing server
If it is necessary to make modifications to an existing server, this task may be performed in the
Server List window, shown previously in Figure 3 - 2.
From the ETM log-in screen, click the Select a new server link. In the Server List window, click the
name of the server to be modified.
•
Select the Modify button. The New Server window will open.
•
Make desired changes.
•
Click Save to apply changes.
•
Click Close to close the Server List window and return to the ETM login screen.
Delete an existing server
If it is necessary to delete an existing server, this task may be performed in the Server List window.
In the Server List window, click the name of the server to be deleted.
•
Select the Delete button. The selected server will be removed from the Server List.
•
Click Close to close the Server List window and return to the ETM login screen.
Add additional servers
If it is necessary to add additional servers, this task may be performed in the Server List window.
In the Server List window, click the Add button. The New Server window will open.
User Guide
•
Server Nickname: Enter a user-defined name for this server.
•
Server Location: Enter the physical location of the server.
•
Server FQDN: Enter the fully qualified domain name for the server. (see example in the
New Server display)
•
Make this my default Authentication Server. Enable this setting to connect to this server
each time this instance of ETM starts.
•
Click Submit to add the new server.
•
Click Close to close the Server List window and return to the ETM login screen.
98-1671 Rev AA
39
Draft 8.5.13
Chapter 3 - Using Endpoint Testing Manager (ETM)
Landis+Gyr
After Login: Setup Cautions

NOTE: When ETM is first launched, view the Connection tab. Click the checkboxes for both
Display Scrolling Status and Enable Test Reports, and then click Save Settings. Until changed,
these settings will remain the default each time the ETM application opens.
CAUTION: Upon launch, ETM will attempt connection to the computer’s first available serial
port. If an Integrated WAN Radio (IWR) is not connected to that serial port, ETM will time out.
After ETM times out, click the Connection tab to select the serial port connected to the IWR.
Certificate Attributes
The current status of the Mobile Admin Tool (MAT) Certificate can be viewed in the Security
display.
Figure 3 - 4. Security Menu Options
From the menu options, select Security > MAT Certificate Attributes.
The Token Attributes displays the current status of the MAT Certificate received from
Command Center.
Figure 3 - 5. Token Attributes
40
•
NetWork ID. The Network ID is the utility’s unique Network Identifier. (For endpoints with
v6.x firmware, this parameter cannot be changed in ETM)
•
Token Sequence Number. The Certificate Sequence number uniquely identifies the
certificate issued for the MAT session.
•
Lan Address Block. The LAN Address Block displays the set of LAN Addresses that the
MAT has been provided to use to communicate with endpoints. LAN Address block consists
of 16 addresses, and are provided each time a certificate is requested from Command Center.
•
Token Expiration Time Stamp. Indicates the date and time that the MAT certificate will
expire. The default value is 1440 minutes (one day) and is established in Command Center
Organization Information settings.
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 3 - Using Endpoint Testing Manager (ETM)
•
Keep Alive. This value specifies the amount of time that a session between a MAT and an
endpoint can be inactive before the endpoint closes the session. The default value is 15
minutes.
•
User Priority. The user priority field allows a user of a higher or equal priority to preempt
an existing MAT Certificate. Users with a lower priority cannot gain access if a higher
priority is engaged with the endpoint device. This also provides a method for the system to
lockout a rogue user if a problem is detected on the endpoint.
•
Signature Expiration Time Stamp. This indicates the signature expiration for the MAT
Certificate. It is set to three times the MAT Certificate expiration interval by default. This
allows the MAT user to attempt to access an endpoint using the certificate and get a response
back from the MAT rather than no response for a reasonable period of time before the
certificate expires. A signed certificate is only required when endpoints are in ECC mode.
Request MAT Certificate
In the event that a MAT Certificate is reaching its expiration time, a new MAT Certificate may be
requested from Command Center by selecting the MAT Certificate option from the Security submenu.
From the Menu options, select Security > Request MAT Certificate. The Log-in window will
open.
Figure 3 - 6. ETM Login screen

User Guide
•
User Name: Enter utility-provided user name.
•
Password: Enter utility-provided password.
•
Server Name: The Server name field will display the server to which ETM will connect by
default.
•
Click OK. If the user is successfully authenticated by Command Center, and the user has the
proper privileges (Access and Certificate Authorization), Command Center will issue a
MAT Certificate consistent with the level of security that the utility is using.
NOTE: If a user’s session is nearing expiration, the user may also log out of ETM and log back in to
get a new Certificate. If the ETM either has no Certificate, or the current MAT Certificate expiration
is less than 50% of the original time interval, the MAT requests a new MAT Certificate.
98-1671 Rev AA
41
Draft 8.5.13
Chapter 3 - Using Endpoint Testing Manager (ETM)
Landis+Gyr
ETM Sign In
The ETM user and the ETM tool must 1) be known to and 2) authenticated by Command Center. The
user must have been provided privileges and user credentials in order to access the ETM software. If
the user has not been provided with credentials, the user must contact the utility-designated Security
Administrator.
The process of authenticating with Command Center provides the user with a Mobile Admin Tool
(MAT) Certificate. The MAT Certificate confirms and certifies ETM’s identity to the endpoints.
CAUTION: ETM login has two modes: one with and one without server access (off-line). In
off-line environments, ETM users must go on-line and successfully authenticate themselves
to Command Center once every seven days.
Below is the procedure for logging into ETM:
Launch ETM. The Login to ETM screen will open.
Figure 3 - 7. Endpoint Test Manager - Sign In
•
User Name: Enter utility provided your User Name.
•
Password: Enter utility provided password
•
Server Name: The Server name field will display the server to which ETM will connect by
default. If needed, click the Select a new server link to connect to a different server, as
described above.
•
Click OK. If the user is properly authenticated by Command Center and the user has the
proper privileges (Access and Certificate Authorization), Command Center will issue a
MAT Certificate consistent with the level of security the utility is using.
If the user name and/or password is not authenticated, a warning dialog box will appear. The
user may attempt to log in a total of five times with incorrect credentials before being locked out
of the system. The Security Administrator will need to clear the locked out status via Command
Center.
42
98-1671 Rev AA
User Guide
Landis+Gyr
Draft 8.5.13
Chapter 3 - Using Endpoint Testing Manager (ETM)
Figure 3 - 8. Login Validation
Even though the user may have certificate privileges, this message indicates that certificate server is
not properly set up. (Possible reasons include: the server might be down or the signing utility might
not be set up). If the user clicks OK, ETM will launch and they will be able to communicate to
meters that are not in ECC mode.
Figure 3 - 9. Login Validation
The authentication process provides the user with the required MAT Certificate. The length of time
that the MAT certificate is valid is configured by the utility in the Organization Information settings,
with the default being 1440 minutes.
CAUTION: If a MAT Certificate is nearing expiration, the user may log out of ETM and log
back in to get a new Certificate. If the ETM instance either has no Certificate, or the current
MAT Certificate expiration is less than 50% of the original time interval, the MAT requests a
new MAT Certificate.
Using the Bar-code Scanner
Please read the following information before using the barcode scanner to scan meter information.
WARNING: The bar-code scanner contains a laser light. Do not stare directly into the beam.

NOTE: Ensure that the bar-code scanner beam covers the length of the bar-code.
The figure below illustrates the proper method for scanning a bar-code.
User Guide
98-1671 Rev AA
43
Draft 8.5.13
Chapter 3 - Using Endpoint Testing Manager (ETM)
Landis+Gyr
Figure 3 - 10. Using the Bar-code Scanner
Navigating the Software
ETM is an easy-to-use software application that allows you to perform specific configuration,
verification, and testing procedures. The application is comprised of an upper menu bar, the tabs
listed below, and a Security Status line at the bottom of the display that describes the server
connection and displays the connected endpoint’s security status.
•
Connection
•
Head End Radio
•
Device Test
•
Firmware Download
•
Module
•
Reporting
•
Command Scheduler
•
HAN (ONLY appears when a compatible endpoint is connected)
•
Universal Event Log
•
Service Limiting (ONLY appears when a compatible endpoint is connected)
•
Groups
•
RF Gas/Water (ONLY appears when the appropriate key is added to the Settings.XML file)
•
Collector (ONLY appears when ETM is connected to a Collector)
Use the upper menu bar for exiting ETM, File > Exit, or to display or request Security details (as
specified in the following section).
Table 3 - 1. Upper Menu Bar Security Details
Field
Description
MAT Certificate Attributes
Displays details about the Mobile Admin Tool certificate received from
Command Center.
Request MAT Certificate
Sends a request to Command Center for a Mobile Admin Tool
Certificate. Login permissions will vary access to this feature.
ETM can also be configured to display an Activity Log at the bottom of each screen that allows the
user to view communication activities between the tool and the endpoint.
Configuring a New Gridstream IWR Radio
These parameters can be set via the Head End Radio tab. To configure a new Gridstream IWR
radio:
1. Connect the IWR to the PC
44
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 3 - Using Endpoint Testing Manager (ETM)
2. Select the Head End Radio tab
3. Click the Modify button
4. Change the radio's Network ID to match the utility-specified Network ID (for endpoints with
firmware version v6.x and higher, this parameter is managed by Command Center and cannot be
changed by ETM)
5. Disable the router bit
6. Disable the timekeeper bit
7. Enable the head-end bit
8. Enable the operational bit
9. Set the baud rate to 38400
10. Enter the Latitude and Longitude in the LPP Address field
11. Click Apply to save changes.

NOTE: If only the CRC and baud rate are to be changed, a new Gridstream IWR can be configured
using ETM’s Head-end management. Command Center is used to manage the CRC for endpoints
with firmware v6.x and higher.
Meter Shop Best Practices Use Case - Proper IWR Configuration
This procedure describes proper configuration for IWR radios being used by any technician where
the radio is on a production network.
Do not:
•
Set up your IWR as a router. This will only slow down process actions as the IWR will be
busy routing packets unnecessarily. On a production network this will interfere with the
local mesh when the radio is turned off.
•
Set up your IWR as a head-end. This will cause significant problems with the production
mesh network.
•
Set up your IWR set as a timekeeper. This is will pass the time of your computer to other
network devices.
Using RadioShop, confirm the following settings.

User Guide
NOTE: For information on RadioShop see RadioShop® Getting Started Guide, Landis+Gyr
publication 98-1054.
•
Control Byte 1 - 69 is correct for a mobile IWR. The best way to change Control byte 1 is by
setting WAN address under configure. As you change from a Mobile IWR to Fixed IWR
CB1 changes from 69 > 49.
•
Control byte 2 should be HEX 48.
•
Control byte 3 should be HEX 50.
CAUTION: Control byte 3 is important. It prevents your radio from advertising a path to the
Collector and from trying to register with Command Center every time it is powered on or
reset.
98-1671 Rev AA
45
Draft 8.5.13
Chapter 3 - Using Endpoint Testing Manager (ETM)

Landis+Gyr
•
Control byte 4 should be HEX 69.
•
Control Byte 4 with RF Filter enabled and wide mode enabled should be HEX 29.
•
Control Byte 4 with RF Filter disabled and wide mode enabled should be HEX 28.
•
Max LAN Nodes could be set to 28 or 86 depending on your environment. If you are on a
deployed Normal meter network, 28 would be the best setting. If you are working in a
LARGE meter shop environment handling meter returns, sample testing, and First Article
Testing Max LAN Nodes value 56 (hex 86) would be best.
NOTE: Series IV radios appear in Command Center by default.
Authentication Server Connection
If the current instance of ETM is not connected to the Authentication Server, ETM will display
Work Offline in the status bar.
Figure 3 - 11. Login Validation
Connecting to a Collector
On the Connection tab, click the Collector Settings button to add a Collector. The Collector List
dialog box will appear.
Figure 3 - 12. Collector List Dialog
1. When adding a Collector to the Collector List, click the Add button. The Collector dialog will
appear.
Figure 3 - 13. Collector Dialog
2. Type a unique name into the Collector Name field.
46
98-1671 Rev AA
User Guide
Draft 8.5.13
Landis+Gyr
Chapter 3 - Using Endpoint Testing Manager (ETM)
3. Type the Collector IP address into the IP Address field with the numbers between the periods.
4. Click the OK button to add the Collector.
The added Collector will appear in the Host: drop down box, located on the Connection tab.
5. To connect to the Collector, click Use Collector from the drop-down box.
6. In the Host: drop down box, highlight the name of the Collector you would like to connect to.
7. Click Connect.
When the connection is successful, the Collector tab will appear in the tab group, ETM will
navigate to the Device Test tab, and your radio will be set to field mode.
Use the Disconnect button on the Connection tab to break communications with the Collector
and return to standard head-end radio communications using the COM port.
Connection Tab
The Connection tab allows the user to view and change the connection information for the radio or
Collector connected to the meter being tested. The table below describes the fields on the
Connection tab.
Table 3 - 2. Connection Tab
Field
Description
Connection Settings

 - Use
COM1 - at  dropdown arrow
This button allows the user to Connect or Disconnect, contains a drop
down menu that allow the user to choose a COM port or Collector to
interface with your radio, and contains another drop down menu (Figure
3 - 14.) to select connection speed for the COM port. The available baud
rates are:
9,600
19,200
38,400 (default)
115,200 (for Series IV IWRs)
RadioShop can identify the COM port and baud rate of the radio you are
using.

 - Use
Collector drop-down arrow choose Host drop-down arrow
This button provides for Connect or Disconnect, selecting the Collector
to connect with, and uses a drop-down menu to list collectors available
to host the connected module. When ETM is connected to a Collector, a
tab labeled “Collector” appears.
Host
Allows testing meters in the field by displaying available collectors in the
drop down box.
Collector Settings 

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 81
XMP Toolkit                     : 3.1-701
Producer                        : ScanSoft PDF Create! 7
Creator Tool                    : Microsoft Word - 12-0296 - Exhibit Cover.doc
Create Date                     : 2013:08:05 16:36:16-04:00
Modify Date                     : 2013:08:05 16:36:25-04:00
Title                           : Microsoft Word - 12-0296 - Exhibit Cover.doc
Creator                         : courtney.mcgann
Author                          : courtney.mcgann
EXIF Metadata provided by EXIF.tools
FCC ID Filing: R7PEC6R1S2

Navigation menu