Lee Technology Korea LT2009A TOPVIEW PAGER User Manual LT2009A Manual
Lee Technology Korea Co., Ltd. TOPVIEW PAGER LT2009A Manual
USERS MANUAL
Top-View Paging System User Manual (Manual Ver. 1.00) LEE TECHNOLOGY KOREA CO., LTD. email sales@leetek.org website www.leetekorea.com KOREA HEADQUARTER US OFFICE 3 FL. #499-2, Sang3-dong, 6040 Unity Drive Suite L, Wonmi-gu, Pucheon-city, Norcross, GA30071, U.S.A rd Kyunggi-do, Korea tel +82-32-324-9838 tel +1-678-218-0990 fax +82-32-324-9840 fax +1-678-218-0991 LEE Technology Korea Co., Ltd. Top View Paging System User Manual 1. EQUIPMENT SETUP 1) Charger Setup Charger Base (1 per 15 pagers) W/ Power Supply DC12V 2.5A (1) Remove contents of box and be sure you have all the necessary hardware: Pagers, Chargers, power supplies and etc. (2) You may wish to keep the holders flat on a table or mount them perpendicular to a wall. Plug the power supply into a standard wall outlet and plug the other end into either hole on the side of the Charger Base. If using more than 15 Pagers connect the Chargers together as shown using the power supply and jumper wires. 2) Pager Charging ※ CHARGE YOUR PAGERS FOR 8 HOURS PRIOR TO USE (1) Insert your Top‐View Pagers into the slot of the Charger. (2) The red light should come in front of each Pager indicating that it is charged properly. Be sure all red lights with Pagers come on when a Pager is inserted into the slot. (3) If no light comes on, check your wires and be sure the Chargers are plugged in using the included power supply. (4) If some lights come on and others do not, be sure the jumper wires are installed properly (each side alternates jumpers). Please refer to Charger Hookup above. LEE Technology Korea Co., Ltd. Top View Paging System User Manual ※ The software of the products might be changed without the notice. 2. Top View Pager (For SEEKER Transmitter) 1) SPEC 12 Digits Display Rechargeable Battery Included 2 Button Switch (Up/Down) * The “Down” switch is not currently available. 5 LEDs Vibe and LED Flashing Alert Maximum 10 Number Can Be Stored. 2) PAGER SETUP (1) Insert your pager into the slot of its charger base. (2) The red LED on the top lights up and it indicates the pager is charged properly. (3) Whenever you remove a charged pager from its slot, red light will blink with the initial message, SEEKER COMMUNICATION, for 10 seconds. (4) “READY” is displayed on LCD. 3) POWER ON/OFF Press switch (Up) more than 3 seconds. 4) PAGE The corresponding table number is displayed with the alert for 2 minutes. When paged. Press the button to stop alert. After pressing the button, the message displays for 15 sec. The alert time is alternative, pager displays “PAGED” LEE Technology Korea Co., Ltd. Top View Paging System User Manual 5) MESSAGE (1) CAPCODE 1 9090 – Message alert time for 8 sec (Vibe 1sec/LED ALL ON 1sec) 9091 – Message alert time for 15 sec (Vibe 1sec/LED ALL ON 1sec) 9092 – Message alert time for 30 sec (Vibe 1sec/LED ALL ON 1sec) 9093 – Message alert time for 60 sec (Vibe 1sec/LED ALL ON 1sec) 9292 – VIBE ONLY 9393 – OUT OF RANGE OFF 9494 – OUT OF RANGE ON 9595 – LED/BEEP 9696 – LED/VIBE 9797 – LED 9898 – LED/BEEP/VIBE 99 – SLEEP MODE 8181 – F1, F2, F3, F4 → Message displays with the standard Alert. 8182 – F1, F2, F3, F4 → Message displays with the “Option Vibe” alert. “Option Vibe” F1 → Vibration Only for 11 seconds F2 → Vibration Only for 3 times F3 → Vibration Only for 4 times F4 → Vibration Only for 6 times (2) CAPCODE 2 1) A (F1), B (F2), C (F3), D (F4), 11, 22, 33, 44 – 8 CANNED MESSAGE are available in PC Software. 2) 99 – STOP MODE 3) Other Messages • Top LED continually blinks, unless the user checks the message. • To enter the message delete mode, press the switch for more than 2 sec. • To select the mode, DELETE/ALL DELETE/STANDBY, press the switch for 2 sec. • Selected message can be deleted by pressing the switch for 2 sec. LEE Technology Korea Co., Ltd. Top View Paging System User Manual (3) CAPCODE 3 1) Out of Range Mode – Out of Range Message is displayed on LCD with LED Flash. (4) CAPCODE 4 1) Available in sending a message to all group pagers. 2) Canned Messages can be sent to all group pagers by press 110 and F1 key, and then a pre‐defined message for the F1 is sent to all group pagers, or press [110 + Enter → 11 + Enter], and then a pre‐defined message for the 11 is sent to all group pagers. ※ The sample product is set with the Option of “8182” (Option Vibe) ※ If you would like to change the option vibe mode to the standard alert, and then press “911 ‐ ENTER – 8181 – ENTER” LEE Technology Korea Co., Ltd. Top View Paging System User Manual 3. Top View Pager (For 4 Light Paging System) 1) To Turn pager ON ◈ Press the button at the side of pager for more than 3 seconds, and then it will be turned on with a flashing on LEDs. 2) To stop the alert ◈ Press the button shortly at the side of pager to stop the alert. 3) Page Alert ◈ When the pager is alerted, vibrating lasts for 11 seconds and corresponding LED will keep flashing until the user presses the side button. 4) Program‐mining page alert mode Alert Type Description 9393 Turn out of range OFF 9494 Turn out of range ON 5) To send a distinctive individual message ◈ With this feature, you have the option of receiving the different messages as described below; ① Return Pager: Press pager no. and “F1” button on the PS‐3500 transmitter, then a LED at the “Return pager” will be vibrating for 11 seconds continuously and flashing until pressing the side button. ② Baby hungry: Press pager no. and “F2” button on the PS‐3500 transmitter, then a LED at the “Baby hungry” will be vibrating 3 times for 11seconds and flashing until pressing the side button. ③ Child fine: Press pager no. and “F3” button on the PS‐3500 transmitter, then a LED at the “Child fine” will be vibrating 4 times for 11 seconds and flashing until pressing the side button. ④ Please come: Press pager no. and “F4” button on the PS‐3500 transmitter, then a LED at the “Please come” will be vibrating 6 times for 11 seconds and flashing until pressing the side button. LEE Technology Korea Co., Ltd. NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT. THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS : (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. LEE Technology Korea Co., Ltd.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:01:20 14:03:39+09:00 Create Date : 2009:01:20 14:03:39+09:00 Format : application/pdf Title : Microsoft Word - LT2009A_Manual.doc Creator : Kim2 Document ID : uuid:d664816e-d9c2-48a4-a2c9-3fd7d7c9ba79 Instance ID : uuid:521eb279-2632-46a9-a35f-57d1634a4d5b Page Count : 7 Author : Kim2EXIF Metadata provided by EXIF.tools