Leviton VRSDC Dimmers User Manual 2 of 2

Leviton Manufacturing Co., Inc. Dimmers 2 of 2

User Manual 2 of 2

Single Pole (One location) or 3-Way (Multi-location)Quiet Fan Speed ControlCat. No. VRFØ1-1L, 1.5A120VAC, 60HzINSTALLATION INSTRUCTIONSWARNINGS AND CAUTIONS:• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualiedelectrician.• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,uorescentlighting,amotororatransformer-operatedapplianceotherthanappropriateceilingfans.• Toreduceriskofreorelectricalshock,thiscontrolistobeusedwithceilingfansthatarerated120VAC,totalload1.5amperesmaximum.• Foruseonceilingpaddlefanswithsplit-capacitororshadedpolemotorsonly.Pleaserefertomanufacturer’sinstructionsorratinglabelonthemotortoconrmtype.Usewithanyothertypesofmotorsorequipmentmaycauseoverheatingand/ordamagetothemotorsorequipment.WARNINGS AND CAUTIONS:• ViziaRF+™fanspeedcontrolsarenotcompatiblewithstandard3-wayor4-wayswitches. TheymustbeusedwithcompatibleVizia+TMorViziaRF+™remotesformulti-locationcontrol.• Useonlyone(1)ViziaRF+™fanspeedcontrolinamulti-locationcircuitwithupto9coordinatingremotes(withoutLEDs) orupto4matchingremotes(withLEDs).Theremote(s)willturnthefanonatthespeedselectedatthecontrol.• Recommendedminimumwallboxdepthis2-1/2".• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.DI-000-VRF01-02AFor non-standard wiring applications, referto Wire Nut and Connector Size Chart1-#12w/1to3#14,#16or#182-#12w/1or2#16or#181-#14w/1to4#16or#182-#14w/1to3#16or#18WIRE CONNECTOR / # OF COND. COMBINATION CHART• ForSingle-PoleApplication,gotoStep4a.• For3-WayCoordinatingRemote(noLEDs)Application,gotoStep4b.• For3-WayMatchingRemote(withLEDs)Application,gotoStep4c.Fan Speed ControlFan Hot (Black)Neutral (White)Bla c k Bla c k WhiteWhite Red Green Ground   Line  120 V A C ,  60H z Insulating Label Ye llow/ Red WIRINGFANSPEEDCONTROL:ConnectwiresperWIRINGDIAGRAMasfollows:• GreenorbarecopperwireinwallboxtoGreenlead.• LineHotwallboxwiretoBlacklead.• LoadwallboxwiretoRedlead.• LineNeutralwallboxwiretoWhitelead.• Yellow/RedwireshouldhaveRedinsulationlabelafxed. NOTE:IfinsulatinglabelisnotafxedtoYellow/Redlead,useelectricaltapetocover.• ProceedtoStep5.Hot (Bla c k ) Neutral (White) Fan Speed Control Coo r dinating Remote (no LEDs ) YL/RD RD Bla c k BK WH White White  Black Yellow/Red Red Fan  Line  120 V A C ,  60H z Green  G r oun d   Green  G r oun d   (u n used ) (u n used ) Slotted/PhillipsScrewdriver ElectricalTape Pliers Pencil   Cutters  RulerToolsneededtoinstallyourFanSpeedControlChangingthecolorofyourdevice:Yourdevicemayincludecoloroptions.Tochangecoloroftheface,proceedasfollows:PushinsideattabtoreleaseLineuptabsandpress in sides one atatimetoattachMULTI-DEVICEAPPLICATIONInmulti-fanspeedcontrolinstallations,thereisnoderatingnecessary.Refertothechartformaximumloadperfanspeedcontrol.Ifinstallingfanspeedcontrolinasingledeviceapplication,proceedwiththeINSTALLING YOURFANSPEEDCONTROLsection.Ifinstallingfanspeedcontrolinamulti-deviceapplication,proceedasfollows:InstallingFanControlbyitselforwithotherdevicesBlackRedYellow/RedGreenWhiteInsulatingLabel:Thiswireisusedin3-wayinstallationsonly. For singlepole installations, do notremovethisinsulatinglabel.4312SinglePoleWiringApplication: Step4a2 1 4 BKRDYL/RDCoo r dinating Remot e  Fan Speed Control53 5BlackRedYellow/RedGreenWhite43123-WayWiringwithCoordinatingRemote (noLEDs)Application: Step4b INTRODUCTIONLeviton’sViziaRF+TMcomponentsaredesignedtocommunicatewitheachotherviaRadioFrequency(RF)toprovideremotecontrolofyourlighting.UsingRFtechnologyallowsLevitontoprovidethegreatestsignalintegritypossible.EachmoduleinLeviton’sViziaRF+TMcomponentlineisaZ-Wave®enableddevice.InaZ-Wave® network,eachdeviceisdesignedtoactasarouter.Theserouterswillre-transmittheRFsignalfromonedevicetoanotheruntiltheintendeddeviceisreached.Thisensuresthatthesignalisreceivedbyitsintendeddevicebyroutingthesignalaroundobstaclesandradiodeadspots.TheSceneCapableQuietFanSpeedControliscompatiblewithanyZ-Wave®enablednetwork,regardlessofthemanufacturerandcanalsobeusedwithotherdevicesdisplayingtheZ-Wave® logo. CAUTION:RemembertoexercisegoodcommonsensewhenusingtheTimerfeaturesofyourremote,especiallywhenschedulingunattendeddevices.Therecanbesomeunexpectedconsequencesifnotusedwithcare.Forexample,anemptycoffeepotcanberemotelyturnedon.Ifthatshouldhappen,yourcoffeepotcouldbedamagedfromoverheating.Ifanelectricheateristurnedonbyremotecontrolwhileclothingisdrapedoverit,arecouldresult.DO NOT USEtheremoteforthecontrolofhighpowerheatingappliancessuchasportableheaters.Thisdevicewillnotcontrollightingthatisusedwithelectroniclow-voltageandhighfrequencypowersupplytransformers,norhighpressuredischargelamps(HIDlighting).Thisincludesmercury-vapor,sodiumvaporandmetalhalidelamps.IMPORTANT :For3-Wayapplications,notethatoneofthescrewterminalsfromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthecommon(LineorLoad)inboththefanspeedcontrolwallboxandremotewallbox.MAXIMUMLOADPERFANSPEEDCONTROLFORMULTI-DEVICEAPPLICATIONMorethan2Devices1.5ATwoDevices1.5ASingle1.5ACat. No.VRFØ1/./&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&/./&&Preparingandconnectingwires:Pulloffpre-cutinsulationfromfanspeedcontrolleads.Makesurethattheendsofthewiresfromthewallboxarestraight (cutifnecessary).Removeinsulationfromeachwireinthewallboxasshown:INSTALLINGYOURFANSPEEDCONTROLNOTE:UsecheckboxeswhenStepsarecompleted.WARNING:TO AVOID FIRE SHOCK OR DEATH; TURN OFFPOWERat circuit breakerorfuseandtestthatpowerisoffbeforewiring! Step 1Identifyingyourwiringapplication (mostcommon):NOTE:Ifthewiringinyourwallboxdoesnotresembleanyofthesecongurations,consultaqualiedelectrician. Step 2 Step32431241533-Way1.  LineorLoad  (Seeimportant  instruction   below)2.  Neutral3. Ground4. FirstTraveler  – note color5. SecondTraveler  – note colorSingle-Pole1.  Line (Hot) 2.  Neutral   3. Ground 4. Load Strip Gage  (measurebarewirehere or use gage on backofthedimmer)5/8”(1.6cm)cut  (ifnecessary)•ThisisaZ-Wave® controller• Scenecapable• Twowaycommunication• RFreliability• ON/OFFLEDandFanSpeedlevelLED• Easeofinstallation–Nonewwiring• CompatiblewithotherZ-Wave®enableddevices FEATURESWIRINGFANSPEEDCONTROL:ConnectwiresperWIRINGDIAGRAMasfollows:NOTE:WhenusingthecoordinatingremotewithoutLEDs,thefanspeedcontrolcanbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.NOTE:Maximumwirelengthfromfanspeedcontroltoallinstalledremotescannotexceed300ft(90m).• GreenorbarecopperwireinwallboxtoGreenlead.• LineHot(common)wallboxwireidentied(tagged)whenremovingoldswitchtoBlacklead.• FirstTravelerwallboxwiretoRedlead(notewirecolor).• RemoveRedinsulatinglabelfromYellow/Redlead.• SecondTravelerwallboxwiretoYellow/Redlead(notewirecolor).Thistravelerfromthefanspeedcontrolmustgototheterminalscrewontheremotemarked"YL/RD".• LineNeutralwallboxwiretoWhitelead.WIRINGCOORDINATINGREMOTE:ConnectwiresperWIRINGDIAGRAMasfollows:NOTE:"BK"and"RD"terminalsoncoordinatingremoteareunused.Tightenbothscrews.NOTE: Maximumwirelengthfromfanspeedcontroltolastremoteis300ft(90m).• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentied(tagged)whenremovingoldswitchtoFirstTraveler(notecolorasabove).• SecondTravelerwallboxwire(notecolorasabove)toterminalscrewmarked"YL/RD".ThistravelerfromtheremotemustgototheYellow/Redfanspeedcontrollead.• RemoveWhiteinsulatinglabelfromterminalscrewmarked"WH".• LineNeutralwallboxwiretoterminalscrewmarked"WH".• ProceedtoStep5.
LIMITED5YEARWARRANTYANDEXCLUSIONSLevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLevitonManufacturingCo.,Inc.,Att:QualityAssuranceDepartment,59-25LittleNeckParkway,LittleNeck,NewYork11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.Therearenootherorimpliedwarrantiesofanykind,includingmerchantabilityandtnessforaparticularpurpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandtnessforaparticularpurpose,islimitedtoveyears.Levitonisnotliableforincidental,indirect,special,orconsequentialdamages,includingwithoutlimitation,damageto,orlossofuseof,anyequipment,lostsalesorprotsordelayorfailuretoperformthiswarrantyobligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.DI-000-VRF01-02AWIRINGFANSPEEDCONTROL (wallboxwithLoadconnection):ConnectwiresperWIRINGDIAGRAMasfollows:• GreenorbarecopperwireinwallboxtoGreenlead.• Loadwallboxwireidentied(tagged)whenremovingoldswitchtoRedlead.• FirstTravelerLineHottoBlacklead.• RemoveRedinsulatinglabelfromYellow/Redlead.• SecondTravelerwallboxwire(notecolorasabove)toYellow/Redlead.Thistraveler fromthefancontrolmustgototheterminalscrewontheremotemarked"YL/RD".• LineneutralwallboxwiretoWhitelead.• ProceedtoStep5.Foradditionalinformation,contactLeviton’sTechlineat 1-800-824-3005orvisitLeviton’swebsiteatwww.ViziaRFplus.com• FandoesnotturnONandON/OFFLEDdoesnotturnON - Circuitbreakerorfusehastripped. - Fanhasburnedout. - FanNeutralconnectionisnotwired. - Conrmthatthedeviceisbeingsuppliedfroma120V,60HzACsourceONLY. - Conrmthatunitisprogrammedproperly.Repeat“TOINSTALL”sectiontoverifythatithasbeenincludedintheZ-Wave™network.• Remotedoesnotoperatefan - Ensurethattotalwirelengthdoesnotexceed300ft. TROUBLESHOOTINGAir-GapSwitch: OntheFanSpeedControlonly,engagetheair-gapswitchbygentlypressingthetopofthePushPaduntilthebottomliftscompletelyoutoftheframeandaclickisheard(refertoFigure). Thiswillcutpowertothexture.Afterservicingiscomplete,pressthePushPadbackintoplacefornormaloperation.Cleaning:Cleanwithadampcloth. DO NOTusechemicalcleaners.NOTE:ThelocatorlightwillilluminatewhentheloadisintheOFFpositiontofacilitateaccessinthedark.NOTE:Ifusingthefanspeedcontrolina3-wayapplication,thefanwillturnONatspeedsetonfan’sFanSpeedbar.Thefanspeedcanbecontrolledfromeitherthefanspeedcontrolortheremotelocation.PushPad(Defaultsettings)TurnONfromOFFposition:Tap–FanturnsONtopresetspeed.TurnOFFfromONposition:Tap–FanturnsOFF.Fan Speed BarPressFanSpeedBarrightorlefttoincreaseordecreasefanspeedrespectively.Thereare3speeds-High,MediumorLow.INCREASE:PresstherighthalfoftheFanSpeedBartoincreasefanspeed.DECREASE:PressthelefthalfoftheFanSpeedBartodecreasefanspeed.Ifyoucontinuetohold,thefanwillreducespeedtominimumlevelandthenturnOFF.NOTE:ThefanspeedcanbechangedwhenthefanisoffusingtheFanSpeedBar.Intheeventofpoweroutageorinterruptionthefanwillresettothelastfanspeedwhenpowerisrestored.PushPadLocator LightLED Fan Speed DisplayFan Speed BarOPERATIONNOTE:Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.• Positionallwirestoprovideroominoutletwallboxfordevice.• Ensurethattheword“TOP”isfacingupondevicestrap.• Partiallyscrewinmountingscrewsinwallboxmountingholes.• Restorepoweratcircuitbreakerorfuse.• PressPushPadandfanshouldturnON.IffandoesnotturnON,presstherighthalfoftheFanSpeedBaruntilthefanturnsON. If fan still does not turn ON, refer to the TROUBLESHOOTING section.TestingyourFanSpeedControlpriortomountinginwallbox: Step5RestorePower:Restorepoweratcircuitbreakerorfuse. Installation is complete. Step 7Fan Speed ControlMatchingRemote2BKRDYL/RD53145BlackRedYellow/RedGreenWhite4312Hot (Bla c k ) Neutral (White) Fan Speed control Mat c hing Remote (with LEDs ) YL/RD WH BK  Bla c k Bla c k White White Red  Ye llow/Red  FanLine  120 V A C ,  60H z Green  G r oun d   Green  G r oun d 3-WayWiringwithMatchingRemote (w/LEDs)Application: Step4c ADVANCEDPROGRAMMINGFEATURESDenitionofAModesA) PresetONSpeed:Setstheturnonfanspeedregardlessofthepreviousspeedset(FormerlySpeedLock).DenitionofBModesB) LEDOptions:SetsthetimeperiodinsecondstheLocatorLEDandBrightnessdisplaywillstayonbeforeextinguishing.NOTES:• Thedevicewillexitprogrammingmodeafter3minutesofinactivity• PressingthePushPadatanytimeduringprogrammingwilladvancethedevicetothenextprogrammingmode.ProgramModeAToenterProgramModeA:PressandholdthePushPadandthentherighthalfoftheFANSPEEDBar(^)for5secondsuntiltheLocatorLEDandleftmostLED(LED1)beginstoblink.• TheLocatorLEDwillblinkoncepersecondtoindicateProgramModeA,PresetONSpeed.TochangethecurrentPresetONSpeedfromHIGH(LED7),MEDIUM(LED4),LOW(LED1),usetheFANSPEEDBar.Ifthisfeatureisnotdesired,pressandholdthelefthalfoftheFANSPEEDBar(v)untilnoLEDislit(defaultsetting).BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewillexitProgrammingModeA.ProgramModeBToenterProgramModeB:PressandholdthePushPadandthenthelefthalfoftheFANSPEEDBar(v) for5secondsuntiltheLocatorLEDandrightmostLED(LED7)beginstoblink.• TheLocatorLEDwillblinkoncepersecondtoindicateProgramModeB, LED OptionsMode.TochangetheLED Optionssettings,usetheFANSPEEDBartomovetheLEDtothedesiredpresetsettingaccordingtothechartbelow.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewillexitProgrammingModeB.LED Fan SpeedDisplay1      4      7LEDLED 1 (Default)LED 4LED 7LED LOCATOR TIMEOUTActiveActiveTurns off 5 seconds after useLED BRIGHTNESS DISPLAY TIMEOUTActiveTurns off 5 seconds after useTurns off 5 seconds after useGentlypresstopofPushPadNOTE:ThefanspeedcontrolmustbeinstalledinawallboxthathasaLoadconnection.ThematchingremotemustbeinstalledinawallboxwithaLineHotconnectionandaNeutralconnection.ANeutralwiretothematchingremoteneeds tobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualiedelectrician.NOTE:Maximumwirelengthfromfanspeedcontroltoallinstalledremotescannotexceed300ft(90m).WIRING MATCHING REMOTE (wallboxwithLineHotconnection):ConnectwiresperWIRINGDIAGRAMasfollows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentied(tagged)whenremovingold switchandFirstTravelertoremoteterminalscrewmarked"BK".• SecondTravelerwallboxwirefromfanspeedcontroltoremoteterminal screwmarked"YL/RD"(notewirecolor).Thistravelerfromtheremote mustgotothefancontrolYellow/Redlead.• LineNeutralwallboxtoremoteterminalscrewmarked"WH".FanSpeedControlMounting:TURNOFFPOWERATCIRCUITBREAKER OR FUSE.Installationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate. Step6NOTES:• Ifusinganon-LevitonProgrammer/Controller,refertotheProgrammer/ControllerinstructionsheetforIncludingadevice.• IfusingtheVRCPG'sInstallChecklistfeature,godirectlytoStepB.A)IfusingaLevitonZ-Wave®Programmer/Controller,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.ChooseAdvancedSettings.PressthecenterbuttontoselectSystemSetupMenu.PressthecenterbuttontoselectNetwork.B)Whilestandingclosetothemodule(approx.2-5ft),pressthecenterbuttonto<Include>deviceinthenetwork. NOTE:Onlyonedevicemaybeincludedatatime.DO NOTputmultipledevicesintotheInclusionmodeatanytime.C)WhiletheProgrammer/ControllerisintheInclusionmodeandtheLocatorLEDisONonthefanspeedcontrol,pushthepushpadtoturnONthefan.TheProgrammer/ControllerwillverifyinclusionandthelocatorLEDwillturnOFFonthefanspeedcontrol.IfthefanspeedcontrolisashingAmberwhileintheInclusionmode,theProgrammer/Controllerisstilltryingtocommunicatewiththefanspeedcontrol.Waituntilthedevicestopsashing,thenpressthepushpad. NOTE:IfthelocatorLEDonthefanspeedcontrolturnssolidRedwhileincluding,therehasbeenacommunicationerror.RefertoTroubleshootingsection.D)ThePrimaryProgrammer/ControllerwillassignanodeIDnumber(Name)forthismodule. NOTE:ThisIDnumber(Name)willbestoredinthecontrollerlibrarytobeusedforfuturereference. NOTE:Youmayeditthenameofthisdeviceatthistime. E) The fan speed control is now installed in the network.NOTE:IfafanspeedcontrolhasbeensuccessfullyIncludedinthenetworkandtheusertriestoIncludeitagainwithoutrstexcludingitfromthenetwork,themodulewillretaintherstnodeIDithadreceivedandignorethesecond.Programmer/Controller Cat.No.VRCPGMenu Button1 ON2 ON3 ON4 ONOFFOFFOFFOFFCenter ButtonIncludingSceneCapableFanSpeedControlintoZ-Wave®Network:VRCPGProgrammer/ControllerNOTE:Remotemustbeincloseproximitytofanspeedcontrolwhenincludinginnetwork.FactoryDefault:Ifyourfanspeedcontrolisnotresponding,oryouareunabletocontrolitafteryouhavetriedtoInclude/Excludeitmultipletimes,itmaybenecessarytoresetthefanspeedcontroltoitsoriginalfactorysettings.Toaccomplishthis,proceedasfollows:• Onthefanspeedcontrol,engagetheair-gapswitch(refertoOperationsection)andwait5seconds.PresspushpadbackintoframeandholdpushpaduntilthelocatorLEDturnsAmberandthenashesRed.Thefanspeedcontrolisnowreset.Oncethefanspeedcontrolisreset,itwillbenecessarytoRe-Includeittoanetworkbeforeitcanbeused.CAUTION:SETTINGADEVICETOAFACTORYDEFAULTDOESNOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSIONPROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICEFROMTHEPRIMARYCONTROLLER’SINFORMATIONTABLE.FAILURETODOSOMAYRESULTINASYSTEMTHATISSLOWTORESPOND,ORMAYFAILTORESPONDTOSOMEDEVICES.ExcludingFanSpeed ControlfromNetwork:NOTE:ItisveryimportanttoaccuratelyExcludedevicesfromthenetworkwhenmovingorremovingadevicefromaZ-Wave®network.ThisensuresthatallinformationhasbeenremovedfromyourPrimaryProgrammer/Controller’sinformationtableandisnotcountedontobeapartofthemeshnetwork.ProtectedunderU.S.PatentNumber6,388,399andpatentspending andlicensedunderU.S.PatentsNumbers5,905,442,and5,982,1032008©LevitonMfg.Co.,Inc.ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthereceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthat towhichthereceiverisconnected.• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.FCCCOMPLIANCESTATEMENTA)IfusingaLevitonZ-Wave®Programmer/Controller,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.ChooseAdvancedSettings.PressthecenterbuttontoselectSystemSetupMenu.PressthecenterbuttontoselectNetwork.B)Whilestandingclosetothefanspeedcontrol,pressthecenterbuttonto<Exclude>devicefromthenetwork.WhiletheProgrammer/ControllerisintheExclusionmodeandthelocatorLEDisONonthefanspeedcontrol,pressthepushpadonthefanspeedcontrol.TheProgrammer/ControllerwillverifyExclusionandthelocatorLEDwillturnOFFonthefanspeedcontrol. IfthefanspeedcontrolisashingAmberwhileintheExlusionmode,theProgrammer/Controllerisstilltryingtocommunicatewiththefanspeedcontrol.Waituntilthedevicestopsashing,thenpressthepushpad. Step8 Step9
FOLD SCHEME 8.5" 14" 2.3" 4.25" FINAL Fold Line DOCUMENTATIONLEVITON INSTRUCTION SHEET/MANUALSPECIFICATIONSH2D  6/20/082008Helvetica DI-000-VRF01-02ABlackN/AFinal fold size:40 Lb. o f fse t 2.3" X 4.25" Overall size:14" X 8.5"  Paper size:Part No.(This panel)Part No.(This panel)

Navigation menu