Leviton VRSDC Dimmers User Manual 3

Leviton Manufacturing Co., Inc. Dimmers 3

User Manual 3

PRELIMINARYWARNINGS AND CAUTIONS:• ON/OFFLEDforremoteloadstatus.• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.• Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician.• Recommendedminimumwallboxdepthis2-1/2".WARNINGS AND CAUTIONS:• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.•Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).• Usethisdeviceonlywithcopperorcoppercladwire.4-Zone Controller with Switch - Single Pole (One Location)Cat.No.VRCZ4-MR,120/240VAC,50/60HzIncandescent-1800W–MagneticLow-Voltage-1800VA(1440W)ElectronicLow-Voltage-1800W–Fluorescent-1800VA–Supplemental-1/2HPINSTALLATION INSTRUCTIONSDI-000-VRCZS-00A-X0 Tools needed to install your deviceSlotted/PhillipsScrewdriver ElectricalTape Pliers Pencil   Cutters  RulerONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFONOFFWARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER atcircuitbreakerorfuseandtestthatpowerisoffbeforewiring! Step 1 Step 35/8" (1.6 cm) Strip Gage (measure bare wire here)Cut (if necessary)WIRING DEVICE:Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHotwallboxwiretoterminalscrewmarked"BK".• LineNeutralwallboxwiretoterminalscrewmarked"WH".• Loadwallboxwiretoterminalscrewmarked"RD".Wiring Application:Hot (Black)Neutral (White)Line120VAC, 60HzBKWHGreenGround4-Zone Controller w/ SwitchLoadRDWH Step 424131.Line(Hot)2.Neutral3.Ground4.LoadIdentifying your wiring application (most common):NOTE:Ifthewiringinyourwallboxdoesnotresemblethisconguration,consultaqualiedelectrician. Step 2 INTRODUCTIONLeviton’sViziaRF+TMcomponentsaredesignedtocommunicatewitheachotherviaRadioFrequency(RF)toprovideremotecontrolofyourlighting.UsingRFtechnologyallowsLevitontoprovidethegreatestsignalintegritypossible.EachmoduleinLeviton’sViziaRF+TMcomponentlineisaZ-Wave®enableddevice.InaZ-Wave®network,eachdeviceisdesignedtoactasarouter.Theserouterswillre-transmittheRFsignalfromonedevicetoanotheruntiltheintendeddeviceisreached.Thisensuresthatthesignalisreceivedbyitsintendeddevicebyroutingthesignalaroundobstaclesandradiodeadspots.This4-ZoneControllerismeanttocontrolspecialzoneenabledZ-Wave®products.TocontrolgroupsofdevicesthataremixedordonotsupportzonecommandclassusetheLeviton4-ZoneController(VRCS4).Settingupthisdevicerequiresspecicadvancedcontrollerfunctionalities,yourcontrollermustbeabletoassociatedevicetogroupsandmustbeabletocontrolthezonecontrollercongurationcommandssuchastheadvancedProgrammingRemote(VRCPG).• SwitchON/OFF• ZoneCapable• ThisisaZ-Wave®Controller• Zonecontrolwithouttravelerwires• Cancall4zones• Cancontrolasingleload• ON/OFFLED• Twowaycommunication• RFreliability• Easeofinstallation–Nonewwiring• CompatiblewithotherZ-Wave®enableddevices FEATURES NOTES:• Ifusinganon-LevitonProgrammer/Remote,refertotheProgrammer/Remoteinstructionsheet.• 4-ZonecontrollersincudedintoaZ-Wave®networkmustbeupdatedafteryouhaveincludedallotherdevices.• IfusingtheVRCPGInstallChecklistfeature,gotostepC.A) IfusingaLevitonZ-Wave®Programmer/Remote,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.Pressthecenterbuttonto<IncludeNode>.B) IfusingVRCPGProgrammer/Remote,youwillbepromptedtoplace4-Zonecontrollerintoprogrammingmode.C) ToaccessProgrammode,pressandholdbuttons1and3(refer to figure).Wait5secondsuntiltheLEDturnsAmber.ReleasethebuttonsandtheLEDwillblinkAmber.YouarenowinProgrammingmode.NOTE:IftheLEDonthe4-ZonecontrollerturnssolidRedwhileincluding,therehasbeenacommunicationerror.D) Whilestandingclosetothe4-Zonecontroller(approximately1ft.),pressthecenterbuttonontheProgrammer/Remoteto<Include>deviceinthenetwork.NOTE:Onlyonedevicemaybeincludedatanytime.E) ThePrimaryProgrammer/RemotewillassignaHomeIDandNodeIDforthisdevice.NOTE:ThisinformationwillbestoredintheProgrammer/Remotetobeusedforfuturereference.NOTE:Youmaynameoredityourdeviceatthistime.F)The 4-Zone controller is now installed in the network. If using VRCPG you will be prompted to include switch, otherwise, please proceed to Step G to include switch. Step 8 Including 4-Zone Controller with Switch into Z-Wave® Network:Changing the color of your device:Your4-Zonecontrollerwithswitchincludesthreecoloroptions.ThecontrollershipswiththeWhiteframeattached.Tochangecolorofframe,proceedasfollows:Line up tabs and press in side to attachPush in side at tab to releaseAfterframeisremoved,removeexistingpushbuttonsandreplacethemwithdesiredcolorchangepushbuttons.TochangetheDIM/BRIGHTbutton,beforemountingframe,pressoutDIM/BRIGHTbutton(bottom)frombackofframeandpressinfromfrontofframenewDIM/BRIGHTbutton.TomakeIRcapable,replacewithaDIM/BRIGHTbuttonthathastheIRwindow.INSTALLING YOUR 4-ZONE CONTROLLER W/ SWITCHNOTE:UsecheckboxeswhenStepsarecompleted.Preparing and connecting wires:This4-Zonecontrollerwithswitchcanbewiredusingsidewireterminalscrewsorthroughbackwireopenings.Chooseappropriatewirestrippingspecicationsaccordingly.• Positionallwirestoprovideroominoutletwallboxfordevice.• Ensurethattheword“TOP”isfacingupondevicestrap.• Partiallyscrewinmountingscrewsinwallboxmountingholes.NOTE:Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.• Restorepoweratcircuitbreakerorfuse.• LEDshouldturnON.• Togglebutton1ON/OFFtotestlocalloadoperation.If LED or LOAD does not turn ON, refer to the TROUBLESHOOTING section.Testing your device prior to mounting in wall box: Step 5• Makesurethattheendsofthewiresfromthewallboxarestraight (cut if necessary).Back Wire (either hole may be used) Backwireopeningsaccept#14-12AWGsolid wire copper only.Side Wire Connection Sidewireterminalsaccept#14-12AWGsolid wire copper only.BlInstallationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate.Device Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE. Step 6Restore Power:Restorepoweratcircuitbreakerorfuse. Installation is complete. Step 7 Step 3 cont'd Step 2 cont'd
PRELIMINARYDI-000-VRCZ4-00A-X0©2009LevitonMfg.Co.,Inc.LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties  of  any kind, including merchantability  and fitness for a  particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and tness for a particular purpose, is limited to ve years. Leviton is not liable for  incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.Including 4-Zone Controller with Switch into Z-Wave® Network: Step 8 cont'd  Step 9 Excluding 4-Zone Controller with Switch from Z-Wave® Network:For additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at www.ViziaRFplus.comProtectedunderU.S.PatentNumber6,388,399andpatentspendingandlicensedunderU.S.PatentsNumbers5,905,442,and5,982,103 TROUBLESHOOTINGLoad Device/Switch:• LightsFlickering - Lamphasabadconnection.- Wiresnotsecuredrmlyunderterminalscrewsofswitch.• LightdoesnotturnON - Circuitbreakerorfusehastripped. - Lampisburnedout. - LampNeutralconnectionisnotwired.Controller/Zone:• LocatorLEDoncontrollerdoesnotturnON - Circuitbreakerorfusehastripped. - If4-ZonecontrollerispoweredupandLEDdoesnotturnON, checkwiring.• ZoneControllerdoesnotoperatelights -Checkassociation. -Ensurethatcontrollerwasproperlyupdated.- Re-programyourzone,andensureeachlightisinthecorrectON/OFFstate.• LEDturnssolidRed -Checkassociation. -Ensurethateachdeviceinthenetworkiswithin70ft.(21m)of anotherdevice.Programmer/Remote Cat. No. VRCPGNOTE:Programmer/Remotemustbeincloseproximityto4-Zonecontrollerwhenincludinginthenetwork.Excluding 4-Zone controller:A) IfusingaLevitonZ-Wave®Programmer/Remote,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.Scrolldownto<ExcludeNode>andpressthecenterbutton.B) IfusingVRCPGProgrammer/Remote,youwillbepromptedtoplace4-Zonecontrollerintoprogrammingmode.C) Toaccessprogrammode,pressandholdbuttons1and3(refer to figure).Wait5secondsuntiltheLEDturnsAmber.ReleasethebuttonsandtheLEDwillblinkAmber.Youarenowreadytoexclude.NOTE:IftheLEDonthe4-ZonecontrollerturnssolidRedwhileexcluding,therehasbeenacommunicationerror.D) Whilestandingclosetothe4-Zonecontroller(approximately1ft.),pressthecenterbuttonontheProgrammer/Remoteto<Exclude>devicefromthenetwork.Factory Default:Ifyour4-Zonecontrollerwithswitchisnotresponding,oryouareunabletocontrolitafteryouhavetriedtoInclude/Excludeitmultipletimes,itmaybenecessarytoresetthe4-Zonecontrollerwithswitchtoitsoriginalfactorysettings.Toaccomplishthis,proceedasfollows:• Onthe4-Zonecontrollerwithswitch(refer to figure),pressandholdbuttons1and3.Waitapproximately10secondsuntiltheLEDturnsAmberandthenturnssolidRed.AllowLED'stoblinkredtwice,releasethebuttons.The4-Zonecontrollerwithswitchisnowreset.Oncethecontrollerisreset,itwillbenecessarytoRe-Includeittoanetworkbeforeitcanbeused.CAUTION:SETTINGADEVICETOAFACTORYDEFAULTDOESNOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSIONPROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICEFROMTHEPRIMARYCONTROLLER’SINFORMATIONTABLE.FAILURETODOSOMAYRESULTINSYSTEMTHATISSLOWTORESPOND,ORMAYFAILTORESPONDTOSOMEDEVICES.Zone Application:Push Button (Default settings)Turn ON from OFF position:Press–Zoneisactivated,ZoneLEDturnsON.LEDwillblinkuntilZoneisreached.Turn OFF from ON position:Press–TurnsalllightsinZoneOFF,ZoneLEDturnsOFF.DIM/BRIGHT:PressleftsideofDim/Brightbutton–LightsinlastactivatedZonewilldim.PressrightsideofDim/Brightbutton–LightsinlastactivatedZonewillbrighten.NOTE:ControllerwillonlyDim/Brightdeviceslocatedwithindirectradiofrequencyrange.NOTE:LEDwillbelitonlywhenalllightsinzonehavereachedtheirpresetlevel.Ifthereisamanualchangetoanylightinthezone,theLEDwillturnOFFindicatingthatyouarenolongerinthatzone. OPERATIONLEDPush ButtonDim/Bright ButtonG)Including local Switch: • RemaininAdvancedSettings. • PressCenterbuttontoselect<IncludeNode>. • Theremotewillpromptyoutoputthedeviceinprogrammingmode. • PutVRCZ4intoprogrammingmodefortheSwitchbypressingbuttons2and4. • Waitapproximately5seconduntilbutton1LEDturnsAmber. • ReleaseButtons2and4andbutton1LEDwillblinkAmber. • WhilestandingclosetotheVRCZ4(approximately1ft.)pressthecenterbuttonontheProgrammer/Remoteto<Include>deviceinthenetwork. • ThePrimaryProgrammer/RemotewillassignaHomeIDandNodeIDtoyournewswitch. • Youmaynameoreditthedeviceatthistime.NOTE:Bydefault,switchwillbecontrolledbyButton1onyourzonecontroller.H) Afteralldevicesareincludedintothenetwork,thecontrollermustbeupdated.Toupdatecontrollerproceedasfollows: • Ifusinganon-LevitonProgrammer/Remote,refertotheProgrammer/Remoteinstructionsheetforupdatingcontroller. • IfusingLevitonZ-Wave®Programmer/Remote,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.PressthecenterbuttontoselectUpdate"cntrl".Selectthecontrollertoupdate.PresscenterButtontobeginupdate.Updatewillstartautomatically.Standwithin(1ft)ofcontrollerwhileupdatingNetworktopology. • WaituntiltheVRCPGProgrammer/Remoteconrmscompletion.Updateisdone.NOTE:Ifthe4-ZonecontrollerwithswitchhasbeensuccessfullyIncludedinthenetworkandtheusertriestoIncludeitagainwithoutrstexcludingitfromthenetwork,thenodeIDwillremainthesame.Cat. No. VRCPG1 ON2 ON3 ON4 ONOFFOFFOFFOFFMenu ButtonCenter ButtonZone Programming:NOTE: AlldevicesassociatedtothebuttonsmustsupportZ-Wave®zonecommand.Ifadeviceinthegroupdoesnotsupportthezonecommanditwillnotbecontrolled.•Pressandholddesiredzonebuttonon4-ZoneControlleruntilLEDblinksGreen.•AdjustanyloadsassociatedtothatbuttonbyturningON/OFForDim/Brightentheload.•Pressbuttonagainon4-ZoneControllerandtheLEDwillstopblinking.•Thezonehasnowbeenset. Step 11ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttofollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperationofthedevice.ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthereceiver.• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.• Consultthedealeroranexperiencedradio/tvtechnicianforhelp. FCC COMPLIANCE STATEMENTAnychangesormodicationsnotexpresslyapprovedbyLevitonManufacturingCo.,Inc.,couldvoidtheuser'sauthoritytooperatetheequipment. FCC CAUTIONAfter inclusion process, you must associate Vizia RF light switches, to button on the controllers. Refer to the Primary Programmer/Remote instruction sheet for complete details.NOTE:Thissteprequiresacontrollerthatcancreateassociationliststospecicgroups1-4.NOTE:One(1)Z-Wave®lightswitchcanbeassociatedtomultiplecontrollers(uptove(5)controllersmaximum).NOTE:Ifusinganon-LevitonProgrammer/Remote,refertotheProgrammer/RemoteinstructionsheetforassociatingaViziaRF+lightswitch.NOTE:YourLocalswitchwillbeassociatedbydefaulttobutton1.Device Association: Step 10Excluding Load Control:A) IfusingaLevitonZ-Wave®Programmer/Remote,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.Scrolldownto<ExcludeNode>andpressthecenterbutton.B) IfusingVRCPGProgrammer/Remote,youwillbepromptedtoplaceLocalRelaySwitchintoprogrammingmode.C) ToExclude,pressandholdbuttons2and4(refer to figure).Wait5secondsuntiltheLEDturnsAmber.ReleasethebuttonsandtheLEDwillblinkAmber.Youarenowreadytoexclude.NOTE:IftheLEDontheLoadcontrolturnssolidRedwhileexcluding,therehasbeenacommunicationerror.D) WhilestandingclosetotheLoadcontroller(approximately1ft.),pressthecenterbuttonontheProgrammer/Remoteto<Exclude>devicefromthenetwork.
ARTWORK PRINT SPECIFICATIONSFOLD SCHEME / BINDERY DIAGRAMPART NUMBER REV DESCRIPTIONLine Screen:Angle:Resolution:Offset FlexoOtherBody Material:BinderyThickness:TrimPerfect BindDie cut Saddle StitchDrillFoldThe information in this document is the exclusive PROPRIETARY property of LEVITON MANUFACTURING COMPANY,  INC. It is disclosed with the understanding that acceptance or review by the recipient constitues an undertaking by the recipient. (1) to hold this information in strict confidence, and (2) not to disclose, duplicate, copy, modify or use the information for any pupose other than that for which disclosed.© 2009 Leviton Mfg. Co., Inc.Unpublished, All Rights ReservedPlantApprovals:ARN: Pilot Rev:ECO Number:Artwork Release Date:Artwork Print Specification Sheet Rev A04.epsPMCQAArtist:Notes:OtherCust OtherS & AMktg EngFOR LEVITON USE ONLYSPECIFICATIONS :PROCESS :MANUAL INTERIORS / BINDERY / FOLD SCHEME :COMMENTS :For manuals - designates cover specificationsDimensions:Material:Thickness:Finish::SpotCMYK1:4:3:2:Color(s):over1:4:3:2:Fonts:SpotCMYK1:4:3:2:Color(s):over1:4:3:2:Fonts:Fold LineDie Cut Punch/Drill HoleGlueKiss Cut CellophaneFold LinePerforateDie CutDie Line Key:DCH anche  lac  Heletic anstruction sheet

Navigation menu