Light Speed Vision 16200A Camera User Manual

Light Speed Vision (Beijing) Co.,Ltd. Camera

User manual

Download: Light Speed Vision 16200A Camera User Manual
Mirror Download [FCC.gov]Light Speed Vision 16200A Camera User Manual
Document ID3112104
Application IDerBKeXKJFxZ+9Wnd4IzvFQ==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize146.76kB (1834462 bits)
Date Submitted2016-08-25 00:00:00
Date Available2016-08-25 00:00:00
Creation Date2016-08-24 18:12:15
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2016-08-24 18:12:15
Document TitleMicrosoft Word - QHY16200A英文说明书
Document CreatorPScript5.dll Version 5.2
Document Author: Administrator

4+<$8VHU0DQXDO
QHY16200A User Manual V1.0
QHY16200A is the QHYCCD "A" series cooled astronomy camera. The camera comes with the
following items. Please check if each items is here.
Camera Body
12V Cigar Lighter Cable
1.8 meter BELKIN USB Cable
1.0 meter 12V power cable with lock
Cable for Ground
Silicon gel tube and Silicon gel 
USB HUB BYPASS Board (Red board)
Water proof plastic box 
2inch To M54/0.75 T-ring
Screw drivers for M2 and M3 Hexagon screw
QHYOAG-M
Some Screws for filters
The camera comes with a factory testing report also.
The camera has no 12V AC adapter by default. Some dealers may add an adapter into it. Some are
not. 

This camera can be widely used
TouchSkyAnyWhere

Ca
amera "First
Liight" .
When you gett the came
era . You ca
an try the first
light off the came
era. Please
e following this step:
1. Download
t QHY16
the
6200A system driver, ascom drriver and EZCAP_QT
T software from
QHY16200A web
w page http://www
w.qhyccd.co
om/IC1620
00A.html
2. If you have not insta
alled ASCO
OM Platform
m before, you
y need install it. Yo
ou can dow
wnload the
lasttest ASCOM platform
m from http://www.asccom-standards.org/in
ndex.htm
3. Run the syystem drivver install package.
It will install QHY1620
00A system
m driver, an
n ethernet
drivver and a FTDI
RS23
32 driver (T
This is a co
ombo drive
er package for both Q
QHY16200A
A and
IC16200A. Th
he Etherne
et driver is no
n use since the QHY16200A has no thiss port. but it is useful for
IC16200A)
4. Connect your
12V adapter with
h the 1.0 meter
12V power cab
ble with locck. You may be wonder
to know
if you
u can connect the 12V
V adapter's DC plugiin directly to
t camera without us
sing the
1.0m
meter 12V
V cable with
h lock. The
e answer iss no. The DC
D socket on QHY16
6200A requ
uires a DC
soccket paired with it. Other DC plu
ugin maybe
e not working on it. There is ttwo 12V so
ocket on
cam
mera. You can conne
ect any one
e. These tw
wo DC soc
cket is conn
nect in parralle in the
e camera.
5. Push the Power
buttton to "ON" Position. You will see
s the fan is running
g.
6. Loose the
e USB lock. And conn
nect the US
SB cable
7. If everything are welll, you will hear the shutter soun
nd and the
e color whe
eel start rottating. The
OLE
ED screen become blue.
8. You can confirm
all system
drivers are ok by openiing the harrdware manager:
QHY16200A system
driver
Two
o Serial Po
ort on came
era (Port number
ma
ay be vario
ous)
on Camera
USB HUB

Now
w you can install the EZCAP_Q
QT software
e . And run
n it.
1. Select
Men
nu->Camerra->Conne
ect
2. The
T camera
a will be sh
hown in the
e select lisst. Click Bu
utton OK. Then the left tool box
x will be
exp
pand.
3.C
Click Previe
ew Button. Camera will
w capture one previe
ew frame. During th
he exposurre the OLE
ED
will off to prevvent the light leaking. (In curre
ent firmwarre version, the OLED
D will not sh
how the texxt,
justt a whole blue
color)
4.Y
You can clicck menu->Camera se
etup->temp
p control. Select the
e Auto Con
ntrol and se
et a target
tem
mperature. Here we se
et it to -15C
C. Please pay
p attention the maxx cooling ccapability of
o QHY16200A
is about
40C below
amb
binet. It me
eans in 25C
C environm
mentyou can
c get ma
ax -15C on sensor an
nd in
20C
C environm
ment you can get -20C. You must
consid
der some spare
range for it .
5. You
Y can wa
ait the temperature fa
alling down
n. Since QHY16200A
A sensor iss not small. The
tem
mperature changed
iss not so fasst. You nee
ed to be pa
atient to wa
ait more tim
me for it.
6. You
Y can click menu->
>Camera setup->Col
or Wheel Control
to set
s the CF
FW position
n. Check if the
CFW
W working well.

Notte1: The 12
2V power is
i necessary for the camera.
If you
y do nott power it , the camerra will not work
and
d the USB device can
n not be found. 
Usiing ASCOM and MA
AXIMDL
1. In
n Camera Control. Click
"Setup
p Camera" Button
9KRKIZ'9)5
53OTZNK)GSKXG3UJKR2OYZGT
TJIROIQ'J
J\GTIKJ
3.Select "QHY
YCCD-Cam
mera-Capture) in the ascom camera list and click Prroperties button to se
etup.

/T)
)GSKXGROYZYKRKIZ
'

5. In
n Camera Control-Ca
amera1 click "Setup Filter" Buttton
)NU
UUYK'9)5
53OTZNK,ORZKXUXIU
UTZXURROTMI
IGSKXGSUJ
JKRROYZ

)ROIQ'J\GTIK
KJ([ZZUTGTJYKRKIZ7.?))*,
,ORZKX=NKKRGTJIROIQ6XUVKXZOKYZUYKZ[V
9KZ[
[VZNKLORZKX]NKKRVGXXGSKZKXY

)ROIQ)UTTKIZZZUIUTTKIZHUZNIGS
SKXGGTJLORZKX]NKKR
Ty
ypical QHY162
00A Da
ark/Flat//Calibra
ated Ima
ages w
with Grade2
sensor
This is a typiical Dark Frame
at 300sec
exposure, -1
15C, gain=
=0. Part off the image. 1:1 zoo
om
Stre
etch to bacckground le
evel

Stre
etch to Maxx Range
A tyypical 10se
ec 4*4binning Dark Frame
with all the reg
gion of the image. The vertical blank
band
ding
on the
t right off the image
e is the ove
erscan are
ea. The ov
verscan arrea is impo
ortant for ov
verscan
calibration.We
e recomme
end you reserve this area. You can also see
s two strrip which is
s a little
brig
ghter than the
t image area.Whicch is the "O
Optic Black
k" Area.
The
e difference
e of "Optic Black" Are
ea and "Ovverscan" Area
is that the "Opticc Black" are
ea has a metal
shie
eld on it an
nd it does not
n sensitivve to light, But thermal current still exist. . The "Ove
erscan" are
ea is
a viirtual area and it reprresent the bias .

Abo
out defectt columns
s
You
u may see one or mo
ore vertical columns. The first pixel
of the vertical co
olumn is a bright
dot. Normallyy speaking
g such colu
umn is not a defect column. Th
his is due tto one pixe
el with high
therrmal curren
nt. Becau
use the KA
AF frame tra
ansfer sensor is tranfferring the electron on
o pixel. Alll the
pixe
els after this high the
ermal pixel on the sam
me column
n is getting thermal cu
urrent whe
en transfere
ed
thro
ough this pixel.
Thiss pixel can
n be removved by darkk frame calibration. So
S that you
u need not do more th
hings than it.
You
u may see one or mo
ore black columns wh
hich is not full sensitivvity to the light or it is
s dim to lig
ght.
Thiss is the deffect colum
mn and it ca
an not be re
emoved by
y dark fram
me calibration. The KAF16200
sen
nsor has tw
wo grade. grade1
and
d grade2. From
the specification of the da
atasheet, th
he grade 2

allo
ows some defect
colu
umns. For more
inform
mation on this please
e check KA
AF16200 datasheet.
You
can
n use the "d
defect tools" in some
e image pro
ocess softw
ware to rem
move such
h defect columns.
A Typical
"deffect" colum
mns caused
d by a hot pixel.
Whic
ch is tightlyy and it is not a really defect colu
umn.
It will
w be gone
e after darkk frame callibration.
A Typical
defe
ect column
n with low CTE
or zerro CTE. Th
his is a deffect column
n. You hav
ve to use th
he
som
me defect tools
to rem
move it. 

Use the build-in Color filter wheel
Install filters
QHY16200A has build-in five position 2inch/50mm color wheel. Please following the steps to
install them.
1. Open the camera front case. There is four M3 screws and eight M2 hexagon screws for the front
case. You can use the screw driver supplied with the camera to open it. Among the eight M2 screw
there is one shorter than all the others. Please remeber the position of this screw.
2. You will see the filter disk after remove the front case. The current disk design is suitable for both
50mm unmounted filters and the 2inch mounted filter. You can use the screw set come with the
QHY16200A to fix the filter on the disk. Please pay attention the maximum height of the filter
(excludes the 2inch thread) is 7.0mm. Please make sure the filter plus the screw does not touch
the front case and also does not touch the optic position detector board.
3. After installed the filters. You can power the camrea and connect USB to verify the colorwheel
running well. Then put the front case back.
Control filter wheel in software
In EZCAP. You can control the filter wheel rotate by select menu->camera setup->colorwheel
control
Select a number and the colorwheel will run to this position. If the number is the current position of
the colorwheel the camera will ignore of it.
In ASCOM.
Please refer to chapter " Using ASCOM and MAXIMDL" above.

Use OAG-M
QHYOAG-M and a M54 adapter come with the QHY16200A. By six M3 screws you can install
them .
The prism of the OAG may have a protect film on front surface. Please remove it before using.
You can use QHY5L-II-M as the guider. Please pay attention that you may remove the front part of
QHY5L-II-M to get the back focus short enough for this combination of OAG-M and QHY16200M. If
you are using other guider. We are not gurantte the back focus is suitable for them due to the very
short back focus of the QHY16200A.
The thinkness of QHYOAG-M is 10mm and the M53 adatper is 3mm. So the totally back focus
addon is 13mm. The QHY16200A back focus is 33.5mm. So the total back focus with
QHYOAG-M is 46.5mm. 

Us
se the On-Cam
mera Serrial Porrt
QHY16200A has two on
n-Camera Serical Po
ort. It conn
nect to the internal USB hub via
a FTDI USB to
Serrial Port co
onvertor. Th
he Serical Port has standard
RS232 level (+-10V) . You can connect
to the
RS2
232 to the mount or focuser.
Pllease note
e it is not TT
TL (+5V) voltage
leve
el so you can
c not use
e it
for EQMOD directly.
EQ
QMOD is TT
TL level. You can use the leve
el converto
or if you wa
ant use thiss
portt to EQMO
OD.
Afte
er you insta
alled the syystem drivver of came
era, the serical port driver
is insstalled toge
ether. Plea
ase
che
eck the CO
OM port num
mber and set
s it in the
e applicatio
on software
e .
The
e serial porrt cable is the
t optiona
al Accesso
orie for QHY16200A. QHYCCD
D is making some typ
pes
of th
he serical port with different
so
ocket type. Please contact QHY
YCCD for m
more inform
mations. 
The
e PIN defin
nition of th
he 3PIN so
ocket
Please check the relatio
on position to the "red
d" dot of th
his socket.

Other Port and Socket
In QHY16200A there is two USB HOST Port. Which is connect in the on-camera hub. You can use
this port to connect the guider or anyother USB device. The USB port can output 500mA current
each.
On top of the camera this is a "CCD Clean" Port. Normally this port is in-factory using propose.
Normally you do need to open it.
On the side of the camera there is a "Silicon gel socket". It can be used to dry the CCD chamber.
See the topic of "Drying CCD Chamber" for it.
QHY16200A has the "Trig-In" and "Trig-Out" Socket. Trig-in is the trigger input socket and allow
you send a pulse to the camera and the camera will begin to exposure. The Trig-Out socket can
output a signal to indicate the exposuring period of the camera. This two port is isolated by 
RSWRFRXSOHUUHOD\
. If you need to use this two port please contact QHYCCD for details.
USB Bypass Board
QHY "A" series camera includes a build-in USBHUB and it can expand two USB Host and two
RS232 via a USB->Serial Port convertor. In some condition it may not work , for example, the
QHY16200A is under another USBHUB and sometimes it has conflict that cause the problems. You
can replace the HUB board with this Bypass Board by openning the case of the camera. 
Here is a step by step guide of how to replace this board.
http://note.youdao.com/groupshare/?token=D1C38D9FEEDD41D2A8C7D33F9EB74294&gid=723
4866

Afte
er you insta
alled the bypass boa
ard. The ca
amera's two
o USB hosst port and two RS23
32 port will be
no function.
GND Socket
Kee
ep the cam
mera grounded with other
device
e is very im
mportant fo
or get the ssystem stable and sa
afe.
The
e QHY1620
00A has a GND sockket for this propose. This
socke
et is connecct to intern
nal "GND" of
the camera. The
T "GND"" is just the
e "-" of the 12V input. There is cable
come
es with the
e camera and
you
u can inserrt this cable
e in the GN
ND socket and conne
ect anotherr side of the cable to other device's
GND that you
u want to ke
eep them grounded.
For examp
ple, the mo
ount's meta
al case, the computter's
mettal case etc. If you do
oes not understand this please consult th
he electric e
engineer. 
Don't connec
ct this cab
ble to AC power boa
ard directly, it will b
bring the risk
of electric
sh
hock .

The on-camera OLED display
The on-camera OLED display is used to display some informations. This OLED is driven directly by
the applicaton software. In different software it may display different informations. In current
applications this OLED is not actived.
FAQs
1.What's the back focus of this QHY16200A
The backfocus is 33.5mm. When connect with QHYOAG-M and M54 adapter it is
33.5mm+13mm=46.5mm
Camera Maintenance
Drying the CCD Chamber
The CCD sensor is located in a CCD chamber. This chamber is airpoor and connect to the socket
of the silicon gel tube on one side of the QHY16200A case. If there is moisture and cause the CCD
sensor glass get dew. You can connect the silicon gel tube on the socket to dry it.

Please put the effective silicon gel into the silicon gel tube. Make sure this is a cotton inside to
prevent the silicon gel get into the CCD chamber. 
Avoid CCD chamber optic window get dew
If the envrioment humidity very high, the optic window of the ccd chamber may get dew. The
QHY16200A has the build-in heat board on this optic window to heat the optic window to avoid it. In
most conditions it can take effection.
If the optic window still get dew please try the following method.
1.Avoid the CCD Camera face down to ground. The cold air is heavy than warm air, if you put the
camera facing down to the ground, the cold air is easy to get the optic window and cause it very
cold and get dew.
2.Increase the temperature of the CCD sensor. You can increase the CCD sensor temperature a
little to prevent the optic window get dew.
3.Check if the heat board working. If the heat board not working, the optic window is easy to get
dew. Normally the heat board can get about 65-70C in +25C enviroment . If it is not so warm, it
maybe the problem of the heat board damaged. Need to contact QHYCCD to replace one heat
board.
Clean the CCD Sensor
Normally you can use the flat frame to calibrate the dust shadow on the image. QHYCCD
does not recommand you open the ccd chamber to clean it. It may bring more dust if you
can not control the enviroment dust. It also may bring the scratch when cleanning CCD
sensor or cause some cable damaged during assembly the camera.
QHYCCD has the factory clean service. It is USD100 per time and it does not includes the
ship cost. 

If you really want
to clean it . Ple
ease follo
owing this step. 
You
u need pre
epare the tools by yourself
to
o open the
e camera.
Rem
move all th
he screws on
o front of the camerra case and remove the front ca
ase

?U[
[]ORRYKKZZ]UYIXK]
]YZULO^ZN
NKLORZKX]N
NKKRIGYKZNKSOJJRKRG_KXULLZNKIGSK
KXG[TYIXK]
ZNK
KS
?U[
[]ORRYKKZZNKVU]KX6)(HUG
GXJ8KSU
U\KZNKZ]UYIXK]U
ULZNKVU]
]KX6)(HU
UGXJ

8KS
SU\KZNKZNXKKIGH
HRKIGXKL[RR_
6RKGYK[YKGLORSZUVXXUZKIZZNKIIJINGS
SHKXUVZOI
I]OTJU]
:NK
K))*ING
GSHKXOYIUTTKIZOTM
M]OZNZNK
KYOROIUTMK
KRZ[HKYU
UIQKZH_GX[HHKXVOOVRK8KSU
U\K
ZNK
KZ]UYIXK]
]LUXZNKYOROIUTMK
KRYUIQKZ

Rem
move the fo
our screw for the ccd
d chamber.. There is totally eight screws fo
or the ccd chamber.
Only
rem
move the fo
our screws pointed byy the red arraow
in th
his picture..
Now
w the ccd chamber
iss removed . The CC
CD sensor can be cle
ean here.

:NK
K))*YKT
TYUXNGYZN
NK'8IUGZOTM6RKGYKIRKGTOZZIGXKL[RR_
_H_[YOTMZNKRKTYV
VGVKXUX
GTU
UZNKXVXULLKYYOUTGRZZUURYROQKZNK*298
8YKTYUXIRKGTZUURY
Notice
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC ID: 2AJFC-16200A
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipmentDŽ
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for
help.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Administrator
Create Date                     : 2016:08:24 18:12:15+08:00
Modify Date                     : 2016:08:24 18:12:15+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Metadata Date                   : 2016:08:24 18:11:07+08:00
Format                          : application/pdf
Title                           : Microsoft Word - QHY16200A英文说明书
Creator                         : Administrator
Document ID                     : uuid:dc99132a-82cc-4ed9-a75f-a7eb8395740b
Instance ID                     : uuid:c81fcfec-7546-4d95-89c6-08050c2c8748
Page Count                      : 25
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AJFC-16200A

Navigation menu