Wiring Instructions for TI-111 Series 2 & 4 Function, FET Receivers. TI111RX.01E 1. IDENTIFY POWER CONNECTION POINT AND ISOLATE SUPPLY BEFORE YOU START The Receiver is designed to carry a maximum of 15 Amps. That is, for example,15 Amps through one output or 5 Amps each through 3 outputs. Fuse 2. Master Output. This can be configured to Continuous or Parallel operation, see overleaf for details. 3. If Receiver outputs are connected in parallel with an external switching device (wired remote) the Receiver will instantly switch off when the wired remote is operated 4. Lodar Receivers MUST have an isolation switch for safety, to allow for registering a replacement Transmitter. 5. or Disconnect Battery ! WARNING Vehicle batteries contain gasses which are flammable and explosive. Wear eye protection and do not lean over battery while disconnecting. Do not wear metal jewellery. Safety Feature. Both the Transmitter and the Receiver will “time out” after 30 minutes of inactivity. This can be altered, ask your dealer. Shown with optional Keypad POSITIVE STOP MOUNT RECEIVER CAUTION Remove fuse NEGATIVE 9000 www.lodar.com TAKE TIME TO LOCATE THE BEST POSITION If necessary, power the Receiver and move it around the vehicle until the required performance is achieved. Operate the Transmitter and observe the Receiver internal LED’s. F1 F2 F3 F4 92 00 RX & 93 00 RX have 4 core cable Mount as HIGH as possible AVOID surfaces with HEAVY VIBRATION AVOID DIRECT SPRAY from wheels In a HOT CLIMATE fit in a SHADED position Cable gland should face DOWN or BACK 92 02/4 RX & 93 02/4 RX have 7 core cable Receiver 9204RX and 9304RX shown, Waterproof to IP67, complete with 3 metres (10 ft) cables Secure using 5mm (3/16") bolts (not supplied) through the 4 mounting feet What is the MASTER Output for ? mini IN UP OUT DOWN CONNECT WIRES LEFT F1 F2 F3 F4 Transmitter Function Convention Make notes about the connections made in the boxes below RIGHT www.lodar.com 9200RX and 9300RX 9202RX and 9302RX Wire Colour Wire used for RED 12/24 Volts DC Nominal Positive Supply BLACK Negative GREEN Output Function 1 YELLOW Output Function 2 BROWN Output Function 3 Not Present Not Used BLUE Output Function 4 Not Present Not Used WHITE Output Function Master Not Present 9204RX and 9304RX It is used to operate the pump of an electro-hydraulic power pack or maybe a clutch pump. It can also be used for powering a dump valve, master valve etc. It can be configured to work continuously, that is ON when SET is pressed and OFF when STOP is pressed; or in parallel with any output, that is, it is active only a function is operated. If it is needed with certain functions only, this can easily be configured. Replace fuse Fuse ACTIVATE THE RECEIVER SUPPLY or re-connect Battery CONNECT TRANSMITTER BATTERY Batteries generally have to be disconnected when shipping. TEST Press the Transmitter RESET button to activate the system, and carefully test each function for correct operation. 92004RX.01E LED marked “SET” Component Detail LED’s marked “F1 - F2 - F3 - F4 and M” When ON indicate an output to that function Indicates system is active LED marked “FAULT” Indicates an overload is present; the System cannot be RESET until overload is removed. This LED blinks for 20 seconds when the Receiver is initially powered. A replacement Transmitter has to be registered during this 20 second period. LED marked “5V” VOLTAGE Working Range 12 Volts to 36 Volts DC Indicates power supply for control circuits is OK Limits 8 Volts minimum to 40 Volts absolute max. Connection Detail STOP and -, when connected together will cause the Receiver to power down S-, S+ Connections For Safety Solenoid etc. Part No. 9820 or 9821 RS232 connection for programming and special features Supply 12/24 V DC 40 Volts ABSOLUTE MAX Outputs sockets +, -, F1& F2 F3, F4, and Master. The Receiver is designed to handle 15 Amps, current draw in excess of this will trigger a system shut down. Lk1, when bridged causes the Master Output to be Parallel Any output can handle this maximum current. LK2, when bridged causes the Master Output to be Continuous SMA connector for External Aerial Antenna Part No. 9861, 9862, 9863 or 9869 Jumper MUST be fitted to only ONE link Standard (Internal) Antenna connection Your product is marked with this symbol. It means that used electrical and electronic products should not be mixed with general household waste. There is a separate collection system for these products. In the EEC - Please contact your National Distributor (see www.lodar.com for this information) who will inform you about the take-back of the product. You might be charged for the costs arising from the take-back and recycling. Small products might be taken back by your local collection facilities. Outside the EEC - If you wish to discard this product please contact your local authorities and ask for the correct method of disposal POWER DOWN RECEIVER BEFORE MAKING CHANGES CONTACT INFORMATION Lodar 60 Sandwell Street, Walsall, WS1 3EB. England Tel: +44 (0)1922 613633 Fax: +44 (0)1922 626991 email: sales@lodar.com www.lodar.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 2 Create Date : 2014:07:29 14:04:21Z Modify Date : 2014:07:29 14:04:21Z Producer : Corel PDF Engine Version 16.4.1.1281 Author : Martin Creator : CorelDRAW X6 Title : TI.111.01E.cdrEXIF Metadata provided by EXIF.tools