Lotek Wireless SRX600 Telmetry Receiver User Manual Guide to Keypad and LCD display
Lotek Wireless, Inc Telmetry Receiver Guide to Keypad and LCD display
Contents
- 1. Guide to Keypad and LCD display
- 2. Guide to SRX600 Receiver
Guide to Keypad and LCD display
1 of 20 Guide to the SRX 600 Keypad and LCD Display Revision D, #10055, March 16th, 2005 2 of 20 UNDERSTANDING THE LCD/KEYPAD LAYOUT The keypad and LCD display define the interface through which the receiver is programmed. The program is designed like a hierarchy. All aspects of the program are accessed through keys on the keypad. Keys labelled Setup, Log On, Info, Manual, Codelog and Set Delta provide access to menus (note that in most cases there are also sub-menus). Three of these keys are referred to as modes: Setup, Manual and Codelog. Through these modes, specific aspects of the receiver’s functionality can be enabled, disabled or amended. The keypad is used to enter or select operating parameters, input data and for navigate through menus and pages. Every key, except Light, has two functions. Which function is accessible depends on the state of the receiver. The LCD display is a two line display that is used to request input, either in the form of a menu selection or the entry of a numeric value. It is necessary to spread out the information, therefore the display shows what is referred to as a page, whereby a menu item can link to more than one page. Scroll through pages using the right and left arrow keys or the END/ESC key. The LCD display also provides current setting information. This information depends on whether the receiver is Online or Offline. • If the receiver is Online then the display shows current settings within brackets after the title of a page (e.g. Scan Options) and still allows a new value to be entered. • If the receiver is Offline then the display shows current settings after the title of a page, but there is no provision for a new value to be entered. STARTING THE RECEIVER After turning on the receiver the sequence of messages on the LCD screen will be similar to the following: SRX600 BOOT CODE V2.5 LOTEK WIRELESS INC. SRX600 BOOT CODE V2.5 SYSTEM STARTUP (1) ... USER: NONE (OFFLINE) MODE: SETUP The last page shows if there is a user logged onto the receiver (Online) or not (Offline) and it also displays the mode that the receiver was in (e.g. Setup). Revision D, #10055, March 16th, 2005 3 of 20 Log On ILogging on to the receiver provides the ability to change the state of the receiver. When a log on password is provided the receiver is considered Online. If no password is provided (logged off) then the receiver is Offline. The differences between Online and Offline are described below: • Offline: the receiver allows only read access, which means that most inputs are not allowed unless a log on password is provided. The only input allowed is the Reset Password function. • Online: the receiver allows full write access, which means that all functionality and input capability are available. Log on to the receiver via Log On > 1)Log On or Log On > 2)Log On via Factory Password. Wait a few seconds for the changes to be accepted and then the receiver returns to the last state that was active (e.g. scan) or the start page. The log on password is always 123456 unless it is changed via Setup > 3)Change Password. Logging on via the factory password provides the ability to log on quickly, as long as the factory password (123456) is being used. This feature is convenient for people who do not need or want to have a specific confidential password. Logging on can be done at any time during the operation if the receiver, except while using the Info key and its menu items. LOGGING OFF Logging off can be done at any time during the operation of the receiver, which means that data collection can continue while limiting access to settings via a password. Logging off means the receiver is Offline. Log off from the receiver via Log On > 2)Log Off or Log On > 3)Temporarily Log Off. Wait a few seconds for the changes to be accepted and then the receiver returns to the start page (first information shown after receiver turns on). Temporarily logging off creates a restriction, whereby logging on is only accessible from the keypad and no longer accessible from the SRX Host software, except via the Host’s Keypad Simulator. Revision D, #10055, March 16th, 2005 4 of 20 Setup mode (1): 1)115200 2)57600 3)38400 4)19200 5)9600 6)4800 7) 2400 8)1200 9) 600 SERIAL BAUD RATE 1) Serial I 2) Serial II ##: 1)BAUD RATE 2) PARITY 3) DATA BITS 4) STOP BITS 5)MODEM SERIAL 1) Baud Rate 2) Parity CONFIGURE COMM: 1) Configure 1)SERIAL I 2) SERIAL II SERIAL PARITY(1): 1)NONE 2)ODD 3)EVEN 3) Data Bits SERIAL DATA BITS(2): 1) 7 BITS 2) 8 BITS 4) Stop Bits SERIAL STOP BITS(1): 1) 1 BIT 2) 2 BITS 5) Modem MODEM 1) HAS MODEM 2) VIEW CMDS 3) INITIALIZE SETUP: 1)COMM 2)TIME 3) RESET/CHANGE PASSWORD 1) COMM COMM (CYCLE POWER OFF/ON) 1)CONFIGURE 2)FACTORY SETTINGS 1) Has Modem SERIAL I HAS MODEM (9) 7) YES 2) View CMDS 2) Factory Settings SET TO FACTORY SETTINGS: (SERIAL, 115200, 8, N, 1) 1) SERIAL I 2) SERIAL II 2) Time - see page 5 3) Reset/Change Password - see page 5 Revision D, #10055, March 16th, 2005 3) Initialize 9) NO MODEM INIT CMD1: ATZ0 NO MODEM, PLEASE SELECT IT VIA ‘SETUP/COMM’ 5 of 20 1) GMT Correction 2) Time TIME (11:24:33 17/06/04): 1)GMT CORRECTION 2)LOCAL DATE 3)LOCAL TIME 2) Local Date GMT CORRECTION (-05:00): (HH:MM) > -- LOCAL DATE (17/06/04): (DD/MM/YY)> 3) Local Time RESET PASSWORD (630387): 3) Reset/Change Password (XXXXXX)> OR LOCAL TIME (11:24:33): (24HH:MM:SS)> CHANGE PASSWORD (******): (OLD/NEW)> Revision D, #10055, March 16th, 2005 6 of 20 Manual mode 1) Code Set MANUAL: 2)SEARCH CODE SET(1): 1)LOTEK 2 2)LOTEK3 3) LOTEK4 OR CODE SET: LOTEK 2 1)CODE SET 3)SIGNAL 2) Search ... see page 7 3) Signal ... see page 8 Revision D, #10055, March 16th, 2005 7 of 20 Manual Mode > 2) Search SEARCH 148.220MHZ ID AH0=40 0) PAUSE SCAN 1) CODE SET 2)SHOW BEEP/ID/SENSOR 3)SET 4)GPS 5) INC. FREQ. 6)DEC. FREQ. 7)EN/DIS NOISE BLANK 8) INC. GAIN 1) Start SEARCH (FROM 148.516MHZ): 1)START 2)GAIN 3)MIN FREQ 4)MAX FREQ 5)FREQ STEP 6)SCAN TIME 7)NOISE THRESHOLD 2)Gain 3)Min Freq 4)Max Freq 5)Freq Step 6)Scan Time 7)Noise Threshold 0)Pause Scan 9)DEC. GAIN FOUND: I184 S121 10:54:21 148.220MHZ CODE GAIN =33 0) PAUSE SCAN 1) CODE SET 2)SHOW BEEP/ID/SENSOR 3)SET DELTA 4)GPS 5) INC. FREQ. 6)DEC. FREQ. 7)EN/DIS NOISE BLANK 8) INC. GAIN 9)DEC. GAIN GAIN (87): (00-99) > MIN FREQ (148.000MHZ): (148-152.000MHZ) > MAX FREQ (152.000MHZ): (148-152.000MHZ) > FREQ STEP (002KHZ): (001-999KHZ) > SCAN TIME (2.2S): (0.1-9.9SEC) > NOISE THRESHOLD (40): (00-99) > Revision D, #10055, March 16th, 2005 PAUSE: I999 S102 11:13:46 148.220MHZ AH0=40 0) RESUME SCAN 1) CODE SET 2)SHOW BEEP/ID/SENSOR 3)SET DELTA 4)GPS 5) INC. FREQ. 6)DEC. FREQ. 7)EN/DIS NOISE BLANK 8) INC. GAIN 9)DEC. GAIN 8 of 20 Manual Mode > 3) Signal 1)START 2)GAIN 3)ANT 4)FREQ 5)NOISE THRESHOLD 1)Start SIGNL: I999 S102 11:13:46 148.220MHZ ID AH0=40 1) CODE SET 2)SHOW BEEP/ID/SENSOR 3)SET DELTA 4)GPS 5) INC. FREQ. 6)DEC. FREQ. 7)EN/DIS NOISE BLANK 8) INC. GAIN 9)DEC. GAIN 2)Gain GAIN(87): (00-99)> SIGNAL: 3)Ant ANT(0): (AH0=0, ASP8=1-8)> RADIO FREQ(149.010MHZ): 1)Radio (148-152.000MHZ)> 4)Freq FREQ(149.010MHZ): 1)RADIO 2)ACOUSTIC 2)Acoustic ACOUSTIC FREQ(NONE): (000-999KHZ)> 5)Noise Threshold NOISE THRESHOLD(40): (00-99)> Revision D, #10055, March 16th, 2005 9 of 20 Codelog Mode 1)Config(#1) ... see page 10 CODELOG: 1)CONFIG# 2)SCAN 3)MASTER FTABLE 2)Scan ... see page 16 3) Master FTable ... see page 17 Revision D, #10055, March 16th, 2005 10 of 20 Codelog Mode > 1)Config#1 NEW CFG#(3): 1)New Cfg# (1-8)> 1)Radio ADD RADIO FERQ(#11): (148-152.000MHZ)> ADD FREQ/CH: 1)Add 1)RADIO 2)ACOUSTIC 1)Config(#1) CONFIG(#3): 1)NEW CFG# 2)SCAN SETTINGS 3)FREQ/CH 4)ANT/HYDR 5)FILTERS 6)SENSORS FREQ/CH 2)Acoustic (10): 3)Freq/CH 1)ADD 2)VIEW/MODIFY 3)VIEW/MODIFY ALL 2)View/Modify 2)View/Modify All 2)Scan Settings ... see page 11 4)Ant/Hydr ... see page 12 5)Filters ... see page 13 6)Sensors ... see page 15 Revision D, #10055, March 16th, 2005 149.891MHZ CH456 EN ID: 1)DEL 2)EN/DIS 3)ID/SEN ALL FREQ/CH(2, 4): 1)DEL 2)EN 3)DIS 4)ID 5)SEN ADD ACOUSTIC FREQ(#11) (000-999KHZ)> 11 of 20 Codelog Mode > 1)Config#1 > 2)Scan Settings 1) Code Set CODE SET(1): 1)LOTEK2 2)LOTEK3 3)LOTEK4 1) Scan Time SCAN SETTINGS: SCAN TIME(18.1S): (00.1-99.9SEC)> 2)Scan Settings 1)CODE SET 2)PARAM 3)OPTIONS 4)SITE NUMBER TOTAL SCAN TIME(47:59): 2) Param 3) Options PARAM: 1)SCAN TIME 2)TOTAL SCAN TIME SCAN OPTIONS: 1)TOA 2)CRTO 3)AGC 4)GPS 2)Total Scan Time (MM:SS)> 1) TOA TOA(2): 1)ENABLE 2) CRTO 3) AGC 4) GPS 4) Site Number SITE NUMBER(1234): (0000-9999)> Revision D, #10055, March 16th, 2005 2)DISABLE CRTO(2): DIS 1)EN/DIS 2)TIMEOUT AGC(1): 1)ENABLE 2)DISABLE GPS: DIS CLK, DIS POS 1)EN/DIS CLK 2)EN/DIS POSITION 12 of 20 Codelog Mode > 1)Config#1 > 4) Ant/Hydr 1)Use ASP8 USE ASP8 1)YES 2)NO RADIO ANT GRP(123): (1-8)> 3)Ant 4)Ant/Hydr ANT/HYDR: 1)USE ASP8 2)GAIN 3)ANT 4)HYDR 5) PRIORITY ANT: 1)RADIO ANT GRP 2)RADIO MASTER ANT RADIO MASTER ANT(9): (GRP=0 ASP8=1-8 NO=9)> HYDR GRP(567): (1-8)> 4)Hydr HYDR:1)ACOUSTIC HYDR GRP 2)ACOUSTIC MASTER HYDR ACOUSTIC MASTER HYDR(0): (GRP=0 ASP8=1-8 NO=9)> 1)ASP8 Gain 2)Gain GAIN: 1)ASP8 GAIN 2)AH0 ANT GAIN 3)RADIO MASTER GAIN 4)ACOUSTIC MASTER GAIN 2) AH0 ANT Gain 3)Radio Master Gain 4)Acoustic Master Gain 5)Priority PRIORITY: FREQ, DIS MPVIEW 1)FREQ/ANT 2)EN/DIS MASTER PREVIEW Revision D, #10055, March 16th, 2005 ASP8 GAIN (40,21,33,54,22, 36,47,18): PORT #(1-8)> AH0 ANT GAIN(33): (00-99)> RADIO AMG GAIN(40): (00-99)> ACOUSTIC (00-99)> HM3 GAIN(60): 13 of 20 Codelog Mode > 1)Config#1 > 5)Filters 1) ID Filter FILTERS: FILTER: 1)FILTER TYPE 2)SET REJECT CH/ID 3)SET ACCPET CH/ID 4)SET REJECT ID 5)SET ACCEPT ID 1) Filter Type FILTER TYPE (3): 1)NO FILTER 2)REJECT CH/ID 3)ACCEPT CH/ID 4)REJECT ID 5)ACCEPT ID 1)ID FILTER 1) Add ADD REJECT CH/ID (#33): (XXX/XXX)> REJECT CH880 ID110 (#20): ADD ACCEPT CH/ID (#21): 2) View/Del 1)DEL 5) Filters 2)PULSE FILTER 2) Set Reject CH/Id SET REJECT CH/ID (32): 1)ADD 2)VIEW/DEL 1) Add 2) View/Del 3) Set Accept CH/Id (XXX/XXX)> ACCEPT CH240 ID211 1)DEL SET ACCEPT CH/ID (20): 1)ADD 2)VIEW/DEL (#30): ADD REJECT ID 1) Add (XXX)> 4) Set Reject Id SET REJECT ID (29): 1)ADD 2)VIEW/DEL REJECT ID450 2) View/Del 1)DEL (10): 1)ADD 2)VIEW/DEL SET ACCEPT ID 5) Set Accept Id ADD ACCEPTID 1) Add (XXX)> 2) View/Del 2) Pulse Filter ... see page 14 Revision D, #10055, March 16th, 2005 (#25): ACCEPT ID211 1)DEL (#11): (#03): (#11): 14 of 20 Codelog Mode > 1)Config#1 > 5)Filters > 2)Pulse Filter 1) Echo 2) Noise Threshold 2) Pulse Filter ECHO FILTER (020MS): (000-255)> NOISE THRESHOLD (30): (00-99)> PULSE FILTER: 1)ECHO 2)NOISE THRESHOLD 3)PULSE WIDTH 4)SIGNAL STRENGTH DEV 2.0MS PULSE WIDTH (1): 1)ENABLE 2)DISABLE MIN 3) Pulse Width 18 SIGNAL S DEV (2): 1)ENABLE 2)DISABLE MAX 4) Signal Strength Dev Revision D, #10055, March 16th, 2005 15 of 20 MIN(-0006.0 Codelog Mode > 1)Config#1 > 6)Sensors 1) C 1) Class C): >-C[-6.0, 34.0]/50): 1)MIN 2)MAX 3)LEVEL SENSOR CLASS(0): (0-9)> MAX(+0034.0 C): >+ C LEVEL(050): (001-255)> MIN(+0000.0 PSI): >+ 2) psi 2) Type 6) Sensors SENSORS: 1)CLASS 2)TYPE 3)PARAM PSI[0.0, 50.0]/51): 1)MIN 2)MAX 3)LEVEL SENSOR TYPES(123): (1=C 2=PSI 3=ACT 4=EMG)> MAX(+0050.0 PSI): >+ PSI LEVEL(050): (001-255)> ACT MIN (0): 3) Param SENSOR PARAM: 1)C 2)PSI 3)ACT 4)EMG 3) ACT ([0, 1]/2): 1)MIN 2)MAX 3)LEVEL ACT ACT MAX (1): ACT LEVEL(2): (1-9)> MIN(+0000.0 EMG): >+ 4) EMG EMG ([0.0, 50.0]/51): 1)MIN 2)MAX 3)LEVEL MAX(+0050.0 EMG): >+ EMG LEVEL (001-255)> Revision D, #10055, March 16th, 2005 (051): 16 of 20 Codelog Mode > 2)Scan 1) Continue to Log Data SCAN: I243 S100 14:22:33 148.220MHZ CH800 AMG=33 0)PAUSE SCAN 2)VIEW 3)SET DELTA 4)GPS 7)EN/DIS NOISE BLANK 8)INC. GAIN 9)DEC. GAIN 0) Pause Scan PAUSE: I243 S100 14:22:33 148.220MHZ CH800 AMG=33 0)RESUME SCAN 1)FILTERS 2)VIEW 3)SET DELTA 4)GPS 5)INC. FREQ 6)DEC.FREQ 7)EN/DIS NOISE BLANK 8)INC. GAIN 9)DEC. GAIN 1)Filters ... refer to page 13 TEMP, PRESSURE (C, PSI): 1)C/F 2)PSI/M 2) View 2) Scan VIEW: 1)DISPLAY SCROLL 2) TEMP, PRESSURE UNITS DISPLAY SCROLL: 0 OF 64 DETECTION SCAN(3712 KBYTES FREE): 1)CONTINUE TO LOG DATA 2)DEL ALL DATA (PASSWORD) DELTA FREQ(001 KHZ): (001-999)> 3) Set SET DELTA : 1)FREQ 2)GAIN DELTA GAIN(02): (01-99)> 4) GPS 2)Del All Data (password) DEL ALL DATA (PASSWORD): (XXXXXX)> Revision D, #10055, March 16th, 2005 GPS(OFF) : NOT ENABLED 17 of 20 Codelog Mode > 3)Master Ftable 3) Master FTable 1)UUC Freq UUC FREQ(150.000MHZ): (148-152.000)> 2) Master F Table 148.000MHZ CH001 #1 IS IN CFG: #1,2,4 MASTER FTABLE: 1)UUC FREQ 2)VIEW MASTER FTABLE Revision D, #10055, March 16th, 2005 18 of 20 SET Delta DELTA FREQ(001 KHZ): (001-999)> SET DELTA : 1)FREQ 2)GAIN DELTA GAIN(02): (01-99)> Revision D, #10055, March 16th, 2005 19 of 20 GPS Before GPS fix ... TEST GPS: TIME + POSITION After GPS fix ... TEST GPS: 15:34:27 (GMT) -44.0627687 79.4467891 Other possible message ... TEST GPS: TIME + POSITION ANTENNA OPEN DETECTED Revision D, #10055, March 16th, 2005 20 of 20 Revision D, #10055, March 16th, 2005
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Modify Date : 2005:03:16 13:29:58Z Create Date : 2004:08:11 13:51:00Z Page Count : 20 Creation Date : 2004:08:11 13:51:00Z Mod Date : 2005:03:16 13:29:58Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : Janelle Metadata Date : 2005:03:16 13:29:58Z Creator : Janelle Title : Guide to SRX 600 Keypad and LCD Display Rev D #10055.fm Page Mode : UseNoneEXIF Metadata provided by EXIF.tools